HomeMy WebLinkAboutItem 06 Approval of Utility Extension/Lift Station Agreement for 4 Locos Taco Restaurant – 101 West Silver Star Road�` ' Ocoee ilorldo AGENDA ITEM COVER SHEET Meeting Date: September 17, 2019 Item #: Contact Name: Michael Rumer Contact Number: Ext. 1018 Reviewed By: Department Director: Craig Shadri City Manager: Robert Fr Subject: 4 Locos Taco Restaurant (101 W. Silver Star.Rd) Utility Extension / Lift Station Agreement District #2 Rosemary Wilsen Background Summary: The City desires to support the development/redevelopment of properties in the downtown area. One of the ways the City supports development is by assisting with upgrades to the water and sewer systems. The City currently has the opportunity to partner with VMG Construction Inc. (4 Locos Development) to extend central sewer and upgrade the waterline along North Cumberland Avenue, per the attached "North Cumberland Lift Station #69 Construction Project" Plans. The project's improvements will directly support the "Initial Phase" of the North Cumberland Service Area Diagram (attached) and provide future sewer extension opportunities to the "Extended Phase" shown in the diagram. The partnership will consist of VMG constructing the water and sewer improvements with the City reimbursing VMG an amount of $222,500.00 ($210,000 for sewer and $11,500 for water) and providing a capital connection credit of two (2) ERUs (Equivalent Residential Unit) Sewer for the development. The City recently approved a similar partnership with Top Gun on August 6, 2019, where the City will reimburse the developer $215,170.87 for comparable lift station and force main improvements. Staff will be preparing and seeking commission approval for a fair share partnering program for any future development for the service area depicted in the diagram. The program will be similar to the Southwest Utilities Installation Program already in existence and will include seeking input and comments from stakeholders in the area. Staff/City Attorney will work with VMG Construction to prepare a "Letter of Understanding" formalizing the partnership conditions between the parties. Issue: Should the Honorable Mayor and City Commission approve VMG Construction, Inc. (4 Locos Development) constructing sanitary sewer and water improvements per the "North Cumberland Lift Station #69 Construction Project" for North Cumberland Avenue north of Silver Star Road? 1 Recommendations: Motion for Mayor and City Commission to conditionally approve VMG Construction, Inc. constructing sanitary sewer and water improvement per the North Cumberland Lift Station #69 Construction Project in the total amount of $222,500 and credit two (2) Equivalent Residential Units of Sewer for the 4 Locos Development; and authorize Mayor and Staff to execute a Staff/City Attorney acceptable "Letter of Understanding" with VMG Construction, Inc. Attachments: 1. North Cumberland Service Area Diagram 2. North Cumberland Lift Station #69 Construction Project Plans Financial Impact: The estimated total cost to the City for the project is $239,925 based on the $222,500 construction contribution, $1,500 for FDEP permitting, $2,500 for construction material testing, $2,000 for electrical service from Duke Energy and a 5.0% contingency. The fiscal impact of the Capital Connection Fees for sewer ($7,317.84 per ERU) is $14,636. Funding for the construction will come from Fund 408-535-00-6302 and Capital Fees will come from 401-535-10- 6302. Type of Item: (please marls with an 'Y) ❑ Public Hearing For Clerk's Dept Use: ❑ Ordinance First Reading i( Consent Agenda ❑ Ordinance Second Reading b Public Hearing ❑ Resolution ❑ Regular Agenda ® Commission Approval ❑ Discussion & Direction ❑ Original Document/Contract Attached for Execution by City Clerk ❑ Original Document/Contract Held by Department for Execution Reviewed by City Attorney Reviewed by Finance Dept. Reviewed by 2 Vicinity Map Sheet Index 1. Cover (Cl) 2. Summary of Quantities {SQ1} 3. General Notes {GNI} 4. General Notes {GN2} 5. Key Sheet (K1) 6. Plan Sheet {P1} 7. Plan Sheet {P2} 8. Plan Sheet {P3} 9. Station Details {SDI} 10. Station Details {SD2} 11. Station Details {SD3} 12. Station Details {SD4} 13. Station Details {SD5} 14. Station Details {SD6} 15. General Details {GD1} 16. General Details {GD2} 17. General Details {GD3} 18. General Details {GD4} North Cumberland Lift Station #69 Construction Rusty Johnson Mayor Larry Brinson, Sr. District 1 Commissioner Rosemary Wilsen District 2 Commissioner Richard Firstner District 3 Commissioner George Oliver, III District 4 Commissioner Robert Frank City Manager Craig Shadrix Assistant City Manager Date: July 2019 UTILITIES DEPARTMENT r� • e 1800 A. D. Mims Rd. Ocoee, FI. 34761 (407)905-3159 Chades K. Smith, P.E. LIC. NO: 39632 SCALE: N.T.S. DATE: July 2019 Item No: Description Units Contract Quantity Pl P2 P3 1 Mobilization/Demobilization and General Requirements Lump Sum 1.00 1.00 2 Maintenance of Traffic Lump Sum 1.00 1.00 3 Survey (Horizontal and Vertical Controls &As-Bullts) Lump Sum 1.00 1.00 4 Sanitary Sewer Lift Station Lump Sum 1.00 1.00 5 5' Diameter Receiving Manhole with Liner Lump Sum 1.00 1.00 6 8" Blind Flange (Cap) Each 1.00 1 1.00 7 4" PVC Force Main plus Fittings Linear Feet 900.00 464.00 436.00 8 4"x20" Tapping Saddle with Tapping Valve Each 1.00 1.00 9 4" Plug Valve Each 1.00 1.00 10 6" Sanitary Single Sewer Service Lateral Each 1.00 1.00 11 6" Sanitary Double Wye Sewer Service Lateral Each 1.00 1.00 12 8" PVC Gravity Sewer Main Linear Feet 67.00 16.00 51.00 13 2" Water Main Connection to 8'Water Main Connection including all Fittings Each 1.00 1.00 14 2" Blowoff Each 1.00 1.00 15 1" Single Service Each 4.00 4.00 16 2" PE Water Main Linear Feet 213.00 21100 17 Clearing, Grubbing, and Grading Lump Sum 1.00 1.00 18 Embankment (Clean Import Fill) Cubic Yards 20.00 20.00 19 Unsuitable Material (Removal and Disposal) Cubic Yards 45.00 45.00 20 Remove and Replace FDOTType "D" Curb for Sidewalk Ramp (2' Wide) Linear Feet 26.00 26.00 21 Solid Sodding (Bahia) Square Yards 1,214.00 1214.00 22 Remove and Replace 4" Thick Concrete Sidewalk Square Yards 339.00 339.00 23 Remove and Replace Miami Gutter (2' wide) Linear Feet 10.00 - 10.00 24 Remove and Replace Pavement Square Yards 5.00 5.00 25 6" Thick Concrete Lift Station Approach Square Yards 13.00 13.00 TY OF OCOEE I PROJECT: UTILITIES DEPARTMENT SHEET: 1800 A. D. Mims Rd. Ocoee, FI. 34761 (407)905-3159 North Cumberland Lift Station #69 Construction Project Summary of Quantities 2 of 18 I Charles P.E. N0.39632 GENERAL NOTES: approved by the City. f. Twenty (20) Terminals for Float Connections (Single Phase Only) PART 1- Application of Standards: 1. The City of Ocoee Minor Lift Station Standards are provided for use by the City or other parties where said lift station shall serve at least 3 parcels and be dedicated to and maintained by the City of Ocoee Utilities Department, 2. A minimum of 40' x 40' easement shall be provided for the Lift Station and access to the Lift Station. The Lift Station site shall include an easement for the receiving manhole and for future connections to the receiving manhole. 3. The use of the minor lift station shall be limited in scope, with a request for use in writing and must be approved in writing by the City. Approval shall be at the City's sole discretion, but shall be based on flows to the station not exceeding 40 ERU's and ability of applicable other to have sewer conveyance access to the station. If the minor lift station exceeds flows of 40 ERU's, the City has authority to upgrade station at the expense of the Contractor or Developer. 4, The City owns these plans and details. Any usage and/or modification of plans are prohibited unless written permission is expressly granted by the City. No mechanical or electrical modification/alteration shall be accepted unless otherwise specified by the City. 5. User of these details/specifications shall hold the City and its agents harmless for any use of these details/specifications. Any discrepancies or conflicts found by authorized user of the plans shall be submitted to the City in writing before usage. 6. These details are available from the City in CAD format where designer may elect to overlay hydraulic discharge system conditions (curve) over "performance curve" graph to determine system operating conditions. Designer should select best Impeller and cross -out reference to other impeller. Due to the dynamic of the City's sanitary sewer transmission system, the City may require the system to be modeled using the City's hydraulic model, 7. The use of the minor station shall also be consistent with all provisions and requirements of these standard and City of Ocoee Engineering Standards Manual. Any discrepancy between the standards and the manual shall be resolved in the more stringent requirement as determined by the City. Part2-General Notes 1. The complete Lift Station shall be a Pre -Fab Lift Station with a minimum diameter of 60 inches (5 feet), including valve vault and two FLYGT MP -3102 Pumps at 6 H.P. for the station (unless otherwise required by the City). 2. Wet well and valve vault, including aluminum hatches and aluminum covers, shall be of reinforced polyester fiberglass material meeting or exceeding H-20 loading requirements, and must include identification of ASTM certification and serial tracking number on structure. Structure, including wall, top and floor thickness, and float concrete ballast must be designed and certified by a Florida Licensed Professional Engineer. 3. Wet well hatch shall also be equipped with an integrated Halliday hatch entry protection system. 4. Wet well hatch shall open such that if a worker is backing away from the control panel, s/he will not be able to step directly into the wet well, but instead will back into the hatch panel itself. 5. Pump shall be capable of passing 2" solids. 6. Valve vault hatch shall be sized to permit easy removal of check valve spindle with minimum clearances as shown for 6" diameter pipe. 7. Valve vault shall have sealed P -Trap type floor drain to connect to and sloping to wet well. 8. All location where pipe coupling requires non -rigid coupling shall be of a flexible type SCALE: N.T.S. DATE: July 2019 9. Pressure gauges shall be stainless steel with stainless steel diaphragms and 4.5" diameter dial; oil filled and shall be calibrated in psi with a range of 0 to 100 psi. Gauge shall also include stainless steel petcock valve. 10. Wet well cables shall be located on same side as control panel. 11. Lift Station site shall be graded to assure storm water conveyance away and/or around station's wet well and valve vault. 12. All exposed metal and/or fittings within the lift station shall be 316th stainless steel. 13. Upon completion of station, before final acceptance, a contractor shall schedule a startup of the station. A factory representative of the station shall be present to verify mechanical and electrical operation. In addition, station operation shall be verified, including pumping rates and operating pressures. 14. Shop drawings for pumps, piping, valves fittings, wetwell, covers, manholes, and electrical equipment are required to be submitted to and approved by the Utilities Department prior to construction. 15. The minor lift station shall include 4' receiving manhole and a by-pass pumping appurtenance including ball valves to accommodate by-pass pumping. By-pass pumping shall be configured to accommodate easy access and staging Part 3 -Electrical Notes: A. General 1. For all Duplex Pump Stations a 240 volt, 3 phase, 4 -wire service is required. 2. Control panel shall be powder coated stainless steel duplex panel and assembled by a TUV (UL508 Certified) manufacturing facility. 3. Enclosure shall be NEMA 4X, Min 30". high, 30" wide and 10" deep S.S. with pad -lockable draw latches. 4. The enclosure shall have external mounting feet to allow for wall mounting. All hardware shall be stainless steel. , 5. A heat sensor thermostat shall be attached to the top end of the motor winding and shall be connected in series with the magnetic contactor coil in the control panel to stop motor if winding temperature exceeds 140 C., but shall automatically reset when winding temperature returns to normal. 6, The following components shall be mounted through the enclosure with watertight seal a. one (1) Alarm Beacon (Light) B, one (1) Alarm Horn c. one (1) Generator Receptacle w/ weatherproof Pyle National IRE -4100 cover d. one (1) Alarm Silence Pushbutton 7. The back panel shall be fabricated from 0.125, 5052-h32 marine alloy aluminum. All components shall be mounted by machined stainless steel screws. 8. The following components shall be mounted to back panel: a. Two (two) Square D size "0" Motor Contactors b. One (1) Voltage/Phase Monitor (three phase) MPE-001-240-118 or equal for interchangeability c. One (1) Control Transformer (480 Volts only) d. One (1) Silence Relay e. One (1) Duplex Alternator, MPE-008-120-13Sp or equal for interchangeability PROJECT: CITY E UTILITIES DEPARTMENT SHEET: 1800 A. D. Mims Rd. Ocoee, FI. 34761 (407) 905-3159 g. Six (6) Terminals for Motor Connections h. Three (3) Grounding Lugs I. A 24 volt power supply for the RTU and Floats. 9. The inner -door shall be fabricated from 0.080, 5052-H32 marine alloy aluminum and have continuous aluminum piano hinge. 10, The following components shall be mounted through the inner door. a. One (1) Square D Main Circuit Breaker L, One (1) Square D Emergency Circuit Breaker c. One (1) Mechanical Interlock for Emergency and Main Breaker d. Two (2) Short Circuit Protectors e. One (1) Square D breaker panel mounted Control Circuit Breaker f. Two (2) Square D H -O -A (hand -off -auto) Selector Switch with extra contact for SCADA Alarm Point g. Two (2) Pump Run Pilot Lights h. One (1) Power on Pilot Light I, Two (2) Burlington ETM 710-0002 3" or equal Elapse Time Meters (Non-Resettable) j, One (1) GFI Duplex Convenience Outlet k. Four (4) Float Status Lights with a High Lag Lead and Off Indicator Lights for Floats I.. Sci-Text 1062 Unit 11. Voltage reference to 230V and 240V shall be interchangeable. 12. The use of transformers on the incoming power supply to step up.or down voltage is prohibited. 13. ASci-Text SCADA Controller wired to a Thermal Strip for 10 Alarm Points B. Component Specifications 14. All circuit breakers shall be molded thermal magnetic. 15. The mechanical interlock shall prevent the normal and emergency main breakers from being energized at the same time. 16. The emergency generator receptacle shall be supplied in accordance with FDEP standards. The generator receptacle shall be a Pyle National Model JRE4100 with a 45 degree housing. 17. All motor short circuit protection devices must provide for under -voltage release and class 10 overload protection on all three phases. Visible trip indication, test, and reset capability must be provided for without opening the door. 18. Open frame, across the line, contactors shall be rated per IEC standards and properly sized per the motor requirements. Contactors shall provide for safe touch power and control terminals. 19. Lightning Arrestor shall meet or exceed the requirements of ANSI/IEE std. C62.21-1984 section 8.6.1 and 8.7.3 shall be supplied by electrician and mounted on the bottom side of the switch disconnect ahead of the pump control panel. 20. A phase monitor shall be supplied for three (3) phase service. 21. A green pilot light shall be supplied fon each motor. The pilot light shall illuminate each North Cumberland Lift Station #69 Construction Project GN1 General Notes 3 of 18 Chades K, Smith, P.E. lis "I zoav time the motor is called to run. 22. Each pump shall have an Elapse Time Meter to record the accumulated run time. The ETM shall be 2" diameter non-resettable, six digit, totally encapsulated unit. 23. A red pilot light shall be supplied for control power. The pilot light shall illuminate when the control power is available inside the control panel. 24. Relays shall be ice cube plug in type. Relay contacts shall be rated at 10 amps minimum, DPDT. 25. Twenty (20) terminals shall be supplied for field connections. The terminals shall be rated 20 amps minimum. 26. Each motors over -temperature contact shall be connected to the terminal strip and shall open a contact to de -energize the appropriate motor upon a high temperature within the motor, 27. A 15 AMP ground GLI duplex receptacle shall be supplied and mounted on the inner -door. 28. Ground lugs shall be supplied and appropriately sized for each motor and for service entrance. 29. Nameplates for the inner -door and back panel shall be of a graphic design, specifically' depicting the intent for each device. C. Alarm Monitor/Remote Terminal Unit (RTU) 30. The Alarm Monitor/Remote Terminal Unit shall be a Sci-Text 1062. 31. The RTU shall be accessible on the interior door. 32. RTU shall monitor commercial power, generator run (if applicable), phase balance, station voltage, wet well water level, pump 91, 42 and 13 status (stop, run, fail), pump HOA position status (Hand, Off, Automatic) and all floats'status 33. Phase and Voltage monitoring of the RTU shall be protected by three fast blow fuses. 34. The floats within the wet well will act as a primary control. The RTU shall be the secondary fail override for the station, 35. RTU shall include a seven -hour battery backup. 36. Contractor shall procure the service of the RTU supplier for initial on-site RTU programming and calibration, including set points. 37. Alarms through the RTU will include (low, lag, and high) Float, HOA (on/off), Low Voltage Circuit (24V Circuit), Power Failure and Generator Run (if applicable). 38, The alarm system will be capable of operating, monitoring and sending alarm notifications for power failure, and high float alarm in the event of a total power failure to the lift station. Provisions will also be made for the alarm light and audible alarm to be functional during a total power failure. D. Miscellaneous 39. All wiring on the back -panel shall be contained within the wiring duct. 40. All wiring between the inner -door and the back -panel shall be contained within a plastic spiral wrap. 41. Each wire shall have a wire number at each end to correspond to the as built drawing for field troubleshooting. 42. Provide and install four (4) roto -floats, direct acting float switches, Four sensors shall be for pump operation and the fifth for high level alarm. SCALE: N.T.S. DATE: July 2019 43. The installer of the lift station shall coordinate with and establish power supply from the power company. 44. Install Seal Off in conduit at control panel as prevention from any sewer gases entering. E. Fasteners and Appurtenances 45. All fasteners, lifting cables, float cable bracket, hinges, and appurtenances shall be made of AISI 3045S. 46, A 304SS slide/latch assembly shall be provided for holding the doors open on the wet well and valve box, 47. Slide rails shall be made of Sch. 40 AISI 304 SS. 48. Pump lifting cables and bales shall be made of AISI 304 SS UTILITIES DEPARTMENT SHEET: 1800 A. D. Mims Rd. Ocoee, FI. 34761 (407)905-3159 North Cumberland Lift Station #69 Construction Project GN2 General Notes 4 of Charles K. Smith, P.E. I_IC_ NO 39632 h1T SCALE: N.T.S. DATE: July 2019 a = \ °I��u001111D111t PROJECT: CITY OF OCOEE UTILITIES DEPARTMENT SHEET: 1800 A. D. Mims Rd. Ocoee, FI. 34761 (407)905-3159 V O wo C'S ' i 'St Legend • Proposed Force Main Proposed Water Main Sanitary Sewer Sanitary Sewer Cap Receiving Manhole Sanitary Clean Out Tapping Sleeve with Tapping Valve and Plug Valve Resilient Gate Valve Blowoff Single Service Existing Force Main Existing Water Main SHEET North Cumberland Lift Station #69 Construction Project K1 Key Sheet 9 of 18 Charles K. Smith, P.E. ,.r 11n -¢ova N Construct 20'x24' Concrete Pad (See Sheet SD5, Detail UT308b (Under Lift Station Pay Item) Control Panel Minor Lift Station (See Sheets 9-14 Construct 16LF 8" PVC Gravity Sewer Main 6' Lined Receiving Manhole Top Elevation = 123.00 S. Invert = 115.78. N. Invert= 115.68 SCALE: 1"=20' DESIGNED BY: Milen W. & TJean T. DATE: July 2019 "- -truct 5Wide 6" Thick Nay with 3' Flairs PROJECT: CITY OF OCOEE UTILITIES DEPARTMENT SHEET: 1800 A. D. Mims Rd. Ocoee, FI. 34761 (407) 905-3159 SHEET North Cumberland Lift Station #69 Construction Project P 1 Plan Sheet 6 of 18 CHARLES K. SMITH, P.E. 1 11 vn zaa" Install Single Service Construct 8.5 LF 4" PVC FM Construct 35 LF 4" PVC FM Install 2" Blowoff Install Single Service Construct 55 LF 6" PVC Double Wye Service Lateral (See Sheet GD2) SCALE: 1"=30' DESIGNED BY: Milan W. & TJean T. DATE: July 2019 3' Off Property Line Gravity Sewer Main @ 0.3% slope (Cap 2' from the Property Line) EL: 116.90 PROJECT CITY OF OCOEE UTILITIES DEPARTMENT SHEET: 1800 A. D. Mims Rd. Ocoee, FI. 34761 (407)905-3159 8" Water Main (Installed by Others) with 2" Gate Valve (North) 3. m lest) lust A GD2) EE lust A GD2) the City ontal ain shall be replaced by the Contractor Locations of existing meter boxes may be different as shown. Contractor shall locate meter location and place curb stop near existing meter. North Cumberland Lift Station #69 Construction Project PG) Plan Sheet 7 of 18 CHARLES K. SMITH, P.E. shall hand dig ffic signal pale F N AI th C ,GINEER :S K. SMITH. P.E. 6" Thick Concrete Slab Around Wetwell 2-3 (2") Field Installed Knockouts For Electrical Conduit Connection Detail to be Provided By Contractor to the City of Ocoee EAS INFLUENT PIPE INVERT EJ HIGH LEVEL ALARM EH LAG PUMP ON EG LEAD PUMP ON EF WET WELL INVERT EB SCALE: N.T.S. DATE: July 2019 4" Green Vent with Bronze Bug Screen DS Steel Bracket Emergency Bypass Connector see detail this sheet. DT Station Isolation Fiberglass Valve Box For Grading See Grading Plug Valve 40" x 30" x 24" Deep with Hate Sheet. Match into Existing O • A O Grade Reducer (If DT is -Integrated Lifting Hooks Pressure Gage Restrain Joints From larger than DK) Vault Through 45° Fittings - ' A Reducer Quick Connect -Plug Pressure Gauge (If DT is larger Valve than DK) Existing Grade Plug Valve sized to DK Single Spherical Flexible Tracing Wire fq Coupler sized to DK r U.ion M Fiberglass Valve Box 9�1 Check Valve sized to DK 40" x 30" x 24" Deepwith HatchDT PVC Discharge Fiberglass Invert, Slope to Drain Force Main gi Be -Sized By Engineer 6" Thick Concrete SlabPump Leads Plu Valve sized to DK Around Wet Well 9 Incidental to the Lit StationPipe Rack No Greater -Single Spherical Flexible Coupler sized to DK Fiberglass Wetwell Than 5' Separation 'Stainless Steel Lifting Cable Check Valve sized to DK 18"Min around Wet -Aluminum Access Hatch Schedule 80 PVC sized to DK - Wellwith Lockable Cover Slide //'Gas Vent 24 Volt Flloat Liquid dLevel Controls (Tyule 40 304 B.S. 1p.) I - / w with Box and Cover S with Nut or mp Discharge Sealing Flange x 6" Integral Fiberglass Invert Concrete Collar with #4 Rebar Around Base 6" Thick Gravel Minimum MINOR LIFT STATION SECTION VIEW N.T.S. Owee UT302b z KV \ as wom- rru'�������(((1(IIIII/i������'��'°�'�°��� Flanged Cam Quick Connect 1 Coupling with Connector and Lockable Cap with 1"Tap and Ball/Plug Valve (Brass/Stainless Steel) 24" x 18" x 6" thick Concrete Slab Around Valve and Stand Pipe CITY OF OCOEE I PROJECT: UTILITIES DEPARTMENT SHEET: 1800 A. D. Mims Rd. Ocoee, FI. 34761 (407) 905-3159 Length SECTION A -A EMERGENCY BYPASS CONNECTOR North Cumberland Lift Station #69 Construction Project Station Details LIFT STATION PLAN VIEW N.T.S. 00-9a UT391b SD1 9 of 18 Charles K. Smith, P.E. LIC. NO: 39632 PUMP DATA Dimensions Descriptions DB 5' PUMP NO: DK 2" Pump Discharge Pipe Diameter DR 1 MANUFACTURER: FLYGT ; MODEL: MP 3102 HT 3 ; IMP: 263 ; DIA: 155mm ; DT - MM, SPEED: 3455 RPM; DISCHARGE SIZE: 2" IN; VOLTAGE: 230V EA 108.0'- HZ: 60 ;PHASE: 3 ; HP: 6 EB 108.3' Wetwell Invert EE MIN SOLID SIZE: IN; CURVE: MP3102HT3-263. Pumps Off EF 110.3 2 MANUFACTURER: FLYGT ; MODEL: MP 3102 HT 3 ; IMP: 263 ; DIA: 155mm 112.3 MM, SPEED: 3455 RPM; DISCHARGE SIZE: 2" IN; VOLTAGE: 230V , Top of Structure EJ HZ: 60 ;PHASE: 3 ; HP: 6 , Data Table Notes: A. All structural components, including but not limited to the above items, must be certified by a Florida Licensed Engineer. B. Wetwell diameters sized greater than 6' (72") shall be subject to approval by the City. C. Data not provided by the City In this detail shall be provided by the Engineer. MIN SOLID SIZE: IN; CURVE: MP3102HT3-263. PUMPS OPERATING CONDITIONS RUNNING PUMP: PUMP 1 90 gpm 78.8 ;TDH 25 ; %EFF. PUMP 1 & 2 gpm ; TDH ; %EFF, Pump Data Table Notes: A. Engineer to provide impeller selection which shall be subject to approval by the City. ' Ocoee UT303b SCALE: N.T.S. DATE: July 2019 lllllouulllll,l;; : aA�IIII�ni��1110111� CITY OF OCOEEI PROJECT: UTILITIES DEPARTMENT SHEET: 1800 A. D. Mims Rd. Ocoee, FI. 34761 (407) 905-3159 Ocoee LMOO WETWELL, PIPING, AND FLOATS DATA Dimensions Descriptions DB 5' Wetwell Diameter (shall be minimum of 5'[60"j) DK 2" Pump Discharge Pipe Diameter DR 4" Quick Connect Diameter DS 4" Bypass Pumping Pipe Diameter DT - 4" Station Discharge Pipe Diameter Elevations Descriptions EA 108.0'- Seasonal High Water Table EB 108.3' Wetwell Invert EE 109.5 Pumps Off EF 110.3 Lead Pump On EG 110.8 Lag Pump On EH 112.3 High Level Alarm EI 123.5' Top of Structure EJ 115.6' Influent Pipe Invert Data Table Notes: A. All structural components, including but not limited to the above items, must be certified by a Florida Licensed Engineer. B. Wetwell diameters sized greater than 6' (72") shall be subject to approval by the City. C. Data not provided by the City In this detail shall be provided by the Engineer. North Cumberland Lift Station #69 Construction Project Station Details t.9CIq:81 SD2 10 of 1 8 I Char IC. 9a 2E Meter Base with By -Pass 3" Galvanized Pipe_ (SCH 80) 1 1/2" Stainless r Steel Mounting Bracket Surge Protection Incoming Power Encase In Concrete NOTES Stainless Steel Service Rated Non -Fusible II --------I 2 - 10' Copper Clad 25 OHM Max. Ground Rods, Min. T Apart Galvanized Pipe Cap (Typ) Nipples (Typ) Seal Off (Typ) 2" Motor Conductor Conduit Sch 80 PVC 2" Control Conduit Conduit SCH 80 PVC 2 Coats of Bituminous Asphaltic Paint 4" Above Grade All The Way Down (Typ) - 1. Drawing Is shown for 240 volt power supply. 2. Power supply incoming and to the station shall be underground on the Ilk station site and shall be three (3) phase from a three phase source only. 3. An Remote Telemetry Unit and telephone service is required to service the station. 4. Float controls shall be provided with continuous cable, the length from Float location to control cabinet. No splices shall be allowed or accepted. 5. Pipe support and brackets shall be cut evenly, ground smooth, and coated with approved corroslon treatment. 6. All conduit and piping shall be properly sealed. SCALE: N.T.S. DATE: July 2019 240V CONTROL PANEL INSTALLATION DETAIL N.T.S.. Ocoee UT3ubb _= ((lll(Ilii�'r�' Light Electrical Feed Grounding Wires 6" Fiberglass Fiberglass Strap Pole to Concrete Using S.S. Anchors Existing Ground 10' x 5/8" Copper Grounding Rod Extend Grounding Wiring, Bare #4 Solid J Copper to Station's Grounding10' x 5/8" Copper Grounding Rod T" PVC Sch. 40— Electrical Conduit NOTES: Quality Lighting 64G7 64G1, 700unv SAM (RPTA-190-DT13) Electrical Panel Support W for Lighting Eye 1. All electrical service(s) shall be per latest national electrical code. 2. Wall, slab and control box are for general representation. Contract shall refer to the specific detail(s) for direction and requirements for construction and/or installation. 3. Pole to be 14' in height for finished slab grade and shall meet current hurricane rating for the applicable location of proposed station. 4. Provide continuous ground from light to grounding rod back to existing grounding at panel. 5. Actual light location to be specified on plans. LIFT STATION LIGHTING DETAIL N.T.S. Ocoee UT309 CITY OF OCOEE PROJECT: UTILITIES DEPARTMENT SHEET: 1800 A. D. Mims Rd. Ocoee, FI. 34761 (407)905-3159 no 1 North Cumberland Lift Station #69 Construction Project Station Details " Dia. Holes (Typ) 24" CABLE AND MOTOR CABLE NOTES: 1. (4)1g" Diameter Hooks (middle) 2. (2) 1" Diameter Hooks (each end) 3. Hooks to be evenly spaced. CABLE AND MOTOR CABLE RACK DETAIL N.T.S. Owee UT312 4 SHEET ENGINEER SD3 11 Df 18 Charles K. Smith, P.E. LIC. NO: 39632 1 ASB 0 SCALE: N.T.S. DATE: July 2019 Cellular Antenna Fn� Lei - NOTES: 1. This detail is for minor lift stations and lift stations sized up to 20 H.P. n Outer box size shall be a minimum of 30" x 42" x 12" (W -H -D) or as INDICATION LIGHT 0 cm) 3. SCADA control shall be SCI -Text 1062 Control system with an approved r M --m'-1 cellar modem including service provider. SWITCH 4. I�IRE ■ EMERGENCY CIRCUIT BREAKER Notes and final configuration/layouts shall be approved by the City. 5. The outer door of the panel shall Include three (3) stainless steel latches EARTH GROUND SCI- L--- __J GENERATOR RECEPTACLE equal. TEXT MCB Install Square "D" surge. arrestor on the main power disconnect. 7. RTU MECHANICALLY MOTOR STARTER NB INTERLOCKED RCB RECEPTACLE CIRCUIT BREAKER RTU m TTS DOOR* LOW OFF LEADLAG HIGH LATCH 0 0 0 0 0 PI P2 GFDR I,I II OA H0 19 ■ PADLOCK BRACKET AV NB GRDGRD I__ MCB__ D M ® - 0 In YRTU m m. ®o o m w TERMINAL STRIP ® MS1 MS2 OL OL 12V -DC TTS RTU BATTERY L_J GRID M 123 w Tu Back Panel Enclosed Layout Enclosure Inner Door Layout - NOTES: 1. This detail is for minor lift stations and lift stations sized up to 20 H.P. 2. Outer box size shall be a minimum of 30" x 42" x 12" (W -H -D) or as INDICATION LIGHT specifically directed by the City. 3. SCADA control shall be SCI -Text 1062 Control system with an approved AIR VENT cellar modem including service provider. SWITCH 4. The panel graphic provided are for visual purposes in reference to General EMERGENCY CIRCUIT BREAKER Notes and final configuration/layouts shall be approved by the City. 5. The outer door of the panel shall Include three (3) stainless steel latches EARTH GROUND and stainless steel door handle as manufactured by Hoffman or approved GENERATOR RECEPTACLE equal. 6. Install Square "D" surge. arrestor on the main power disconnect. 7. Outside of panel box shall be powder coated stainless steel. q 3 WON == It Illluoulllln,,: 240V SCADA CONTROL PANEL N.T.S. Owse UT3061, PROJECT: CITY OF OCOEE UTILITIES DEPARTMENT SHEET: 1800A. D. Mims -Rd. Ocoee, FI. 34761 (407)905-3159 North Cumberland Lift Station #69 Construction Project Station Details COMPONENT LEGEND O.es UT367 AB ALARM BELL AL ALARM LIGHT ASB ALARM SILENCE BUTTON ATS ALTERNATOR TEST SWITCH AV AIR VENT CCB CONTROL CIRCUIT BREAKER ECB EMERGENCY CIRCUIT BREAKER GFDR GROUND FAULT DUPLEX RECEPTACLE GND EARTH GROUND GR GENERATOR RECEPTACLE HOA HAND -OFF -AUTO SELECTOR SWITCH MCB MAIN CIRCUIT BREAKER MS MOTOR STARTER NB NEUTRAL BLOCK RCB RECEPTACLE CIRCUIT BREAKER RTU REMOTE TELEMETRY UNIT TTS THERMAL TERMINAL STRIP North Cumberland Lift Station #69 Construction Project Station Details SHEET ENGINEER SD4 12 of 18 Charles K. Smith, P.E. LIC. NO: 39632 Vent Cap with - Concrete Collar Lift Station Valve Utility Easement Property Line R -O -W 5' (MIN) Concrete Electrical Panel: Pump Electrical Leads shall be Continuous to the Control Panel Station Slab Shall be 8" Thick and at a Minimum of 1' Beyond the Outside Diameter of the of the Wetwell and Vault 1" P.E. Water Service which shall including RPZ Pole Mounted Backflow Device with Lockable Faucet Emergency Bypass NOTES: 1. This detail is for general lift station site configuration and requirements. 2. Contractor shall refer to plan sheet(s) for specific lift station site layout and construction details. 3. Receiving manhole shall be located outside of right-of-way and station access, unless approved, and shall be within 25' of emergency bypass. Lift station shall be located as far away from the right-of-way as practical. 4. Receiving manhole shall be 6' In diameter and continuously coated with approved spray liner covering wall, top ring and Invert's bench. . 5-. For manhole specifications, refer to Detail UT104 Large & Receiving Manhole - Ring and Double Cover. 6. Finished grade of station's slab shall be sloped no greater than 0.5%, falling away from both vault and station tops. Refer to grading sheets) for finished grades of the station's slab. UNSECURED LIFT STATION GENERAL SITE PLAN _ N.T.S. 0... UT398b ^3 a` 4 PROJECT: SCALE: CITY OF OCOEE- N.T.S. UTILITIES DEPARTMENT ^_ MIN O SHEET: DATE: 1800 A. D. Mims Rd. July 2019 �����illl/Illiirb% \\nl\ IIIIIII Ocoee, Fl. 34761 (407)905-3159 hole in each corner boarder text -ty of / \ A/'O^ X 1.5"text worl Lift Station (# X In Case of Emergency Please Call 1.25" text Utilities Department 407-948-2013 4n7-5(19-27.51 1.75" text NOTES: 1. Sign must be attached to the outside of the gate by zip tie. 2. Sign must be reflective. 3. Lift Station number to be assigned by the City of Ocoee. 4. No duplicate numbers shall be used. 5. Aluminum panel shall be 5052, H38-060 Alduine Pretreated LIFT STATION SIGN DETAIL Ocoee U1314 North Cumberland Lift Station #69 Construction Project Station Details SHEET SD5 13 of 18 Charles K. Smith, P.E. LIC. NO: 39632 SCALE: N.T.S. DATE: . July 2019 q' SS U -Bolt z"x3x5 S.S. Tubing - (Pipe Rack) Double Locking Nuts, with Finder Washer a"X7"X7" S.S. Plate 2 - z" S.S. Wedge Anchors Anchor Detail 3"x5" S.S. mounting tubing, welded all the way around Strap Detail 11 to fit flat on wetwell wall. Rack to be mounted with 2 S.S. wedge anchors, two (2) per end, epoxy coated and cemented. Install 3" X 5" - 316 S.S. Tubing, Pipe Support Rack Protective Liner Adjustable Overlappinc 2 Feet. Anchoring Detail _..gyp Detail NOTE: S.S. pipe supportshall be equally spaced no greater than five (5) feet in separation, and no greater than three (3) feet from pump flange adaptor and top 90' fitting. S.S. PIPE SUPPORT RACK DETAIL N.T.S. owee UT311 PROJECT: CITY OF OCOEE UTILITIES DEPARTMENT SHEET: 1800 A. D. Mims Rd. Ocoee, FI. 34761 (407)905-3159 Receiving Manhole NOTES Influent Pipe Wet To Station y + Well 1. Influent pipe from receiving manhole to and including drop connection shall be HDPE pipe, continuously welded with the option of one (1) flanged connection. Flanged connection shall be a minimum of three feet from outside of wetwell wall. 2. Wall penetration is schematic only. 3. Drop Connection diameter shall be equal to influent pipe diameter. LIFT STATION DROP CONNECTION DETAIL N.T.S. Ocoee UT313 North Cumberland Lift Station #69 Construction Project Station Details Influent drop, for Bottom Elevation see Station Dimension Table SHEET SD6 14 of 18 I ChaLIG. 9E 2E See Manhole _ nnection Detail Outside of Invert Bench _ /,50102 Manhole Precast Manhole � —��— Inside of Wall (Typ) a 1 Manhole '•y S. S. Band Pre -Molded Plasti Grout with Hydraulic Resilient Connector a _ Joint Sealer with All Joining Cement Around Pipe Surfaces to be Protective Wrapper and Bituminous Coat ail (Wrapper to be Pre -Primed Exposed Surfaces PVC or Removed) ��_ D.I.P Flow Invert to be smoothly Monolithic sloped in the direction of a: S. S. Pipe flow with channel Wall Joint Section - "0.' �a;'�' Clamp Base matching diameter Invert Section Pipe Connection for Pipes Less Than 24" Section - Manhole Ring and Mortar in Ring Cover See Note 8 for Setting Cover Adjust final cover grade with 2 to 4 courses of Cone Transition brick See Note 4 Bituminous (Coal Tar) Coating Both Inside and Outside of Walls Invert Bench to three quarters height of pipe gently sloped (12 to 1) and bituminous coated 6" Min. y Rock Bedding 9" Thick tLj Extending 9" Beyond 8" Min. Float Tab —f Manhole Section NOTES 1. This detail is for pre -cast standard and receiving sanitary sewer manholes, 2. Sewer main sizes connecting to the manhole shall range from 6" to 24" in diameter and not less than 2" from floor of bottom casting. All other sizes shall require separate design and approval. 3. All manholes where any Invert Into the manhole exceeds 18" shall require a drop connection (See detail UT102). 4. Manhole cone/ring and cover shall be eccentric configured. Cone transition shall range from 18" to 36 Concentric configuration shall require written approval by the City. 5. Receiving, forcemain connected and drop manhole shall be continuously lined with an approved liner on the City of Ocoee's Approved Materials List at a minimum of 90 mil thickness. 6. Bottom casting shall be monolithic with first riser. 7. Riser between top cone and bottom casting shall be no shorter in height than 60". 8. Manhole cover to be set 1/4" above and matching slope pavement and should be set at plan grade unpaved areas. 9. All seams from structure joints, pipe connections and ring shall be WrapidSealed. N.T.S. Manhole PVC Tee See Connection f Influent to Section Above for Manhole Tie -In Details (Typ) .+d. Drop Connection Pipe Invert Bench "a (See Note 2) .A Concrete Pipe Encasement Influent to Spring Line of Pipe to Top of Manhole O Bottom Slab and 6" Around Pipe PVC 90 Fitting Drop Invert Standard Drop Section NOTES: 1. For manhole covers, see UT103 Standard Manhole Ring and Cover Detail and UT104 Large & Receiving Manhole Ring and Double Cover Detail. 2. Drop pipe and fittings shall be of equal size and material to the influent sewer line. 3. The drop connection provided above is limited to pipe size less than 24". Alternative design must be approved by City for pipe sizes equal or greater than 24" In diameter. 4. An outside drop connection is required for all influent lines 18" or more above the manhole inverts. 5. Bottom elevation of drop shall be 0.1' above effluent invert. SANITARY SEWER CONNECTION DETAIL N.T.S. Ocoee UT102 PROJECT: £�-CITY OF OCOEE SCALE: 0 - N.T.S.- _ UTILITIES DEPARTMENT SHEET: ��\ DATE: �u///��/�//�p\„ 1800 A. D. Mims Rd. l/lir��,• \ p\\\\ ��\\\\\ Ocoee, FI. 34761 July 2019 ll(llllll�ululllllm(:' nnlllll��u1111111111 (407) 905-3159 VARIES Cover 32 1/2" Flush Ring Section USF 1307 -CR Ring Manhole lining (where required) Flush Structure Casting 23 3/4" Top Half of Cover USF -E 35 3/4" 221/2" Bottom Half of Cover USF 667 -CR Cover 34 1/2" 36" 42" Ring Section USF 667 Ring -Red Brick or .1 Precast Concrete Risers Manhole lining (where required) NOTES: 1. Use Ring and Double Cover as depicted on this sheet for large (6' or greater) and receiving manhole applications. Refer to UT103 for Standard Manhole Ring and Cover Detail for typical manholes. 2. For structures with top elevation at surface, use "Flush Structure Casting", USF 1307 -CR Ring. 3. Brick shall be solid red (clay) brick meeting AASHTO M114 -Grade MW. 4. Manhole lid shall be Lettered with "City of Ocoee" (top), Sewer (center) and. Florida (bottom). 5. Manhole lids shall have two (2) non-pentrating pick holes. 6. Where manhole lining (coating) is required, coating shall extend to ring sealing and coating ring's mortar bed. LARGE & RECEIVING MANHOLE RING AND COVER DETAIL N.T.S. Ocoec OT104 North Cumberland Lift Station #69 Construction Project GD1 Station Details 15 of 18 Charles K. Smith, P.E. LIC. NO: 39632 Varies Varies Lot Line Wye With Branch Sewer Main Size Varies Bond—,45° Bend\ A - Clean-out (See Note 1) Double Plan View Finished Grade Property Line Pipes/Mains Separation Requirement Table Potable Reclaimed Sanitary Sewer Storm Sewer Horiz. Vert. Horiz.. Vert. Horiz. Vert. Horiz. Vert. Potable separation requirements shall apply between newly proposed utility lines and 3' - 12" 6' 12" 3' 12" Reclaimed 3' 12" I 3' 12" 3' 12" Sanitary Sewer 6' 12" 3' 12" reclaimed water for separation requirements. 3' 12" Storm Sewer 3' 12" 3' 12" 3' 12" 6. Where minimum vertical separation from potable water cannot be achieved, the Slope To Terminal Depth /-Slope 1.g"/o Minimum (Typ.) NOTES: 1. The table represents the minimum separation requirements as described in Rotate 300 (Typ.) Spring Line F.D.E.P. rules of the Florida Administrative Code 62-555.314 (F.A.C.). These (See Note 3) separation requirements shall apply between newly proposed utility lines and existing or proposed utility lines. - Sewer Main 2. For the purpose of this table, reclaimed water shall mean unrestricted public access reuse water as defined by F.A.C. 17-610. Other types of reclaimed I water, not treated to public contact levels, shall be considered raw sewage, and Private Single Lateral Double Lateral - Private the separation list for sanitary sewer shall apply. 3. Alternative water, such as storm water used for irrigation, shall be considered To Home Right of Way To Home reclaimed water for separation requirements. 4. Pipe separation distance -provided above shall mean the horizontal and/or Section View vertical distance measured for the outside dimension of each pipe/main. 5. Concrete encased pipes/mains shall use the separation of D.I.P. 6. Where minimum vertical separation from potable water cannot be achieved, the use of one full length (20') of D.I.P. centered at the crossing shall be NOTES: _ permissible. . 7. All utilities shall be installed with 36" of cover over the top of pipe. Cover shall 1. Clean-out (shown hatched) shall be Installed by the builder in be measured with current or future grading to ensure the 36" coverage. accordance with standard plumbing code. 8. No potable water pipe may pass through a sanitary sewer structure. 2. Locate clean -outs as close to the property line as possible. Penetration through storm sewer must be approved by the City and is subject to 3. Invert of service lateral shall not enter sewer main below spring line. special conditions and materials. 4. The minimum terminal depth as required for house service is 3'. 5. Service Laterals shall be a minimum of 6" for non-residential scenarios. - In residential areas, service laterals shall be a minimum of 4" to the right-of-way and then 6" to the sewer main. T.S. Pipes/Mains Separation Requirement Table N.T.S. Ocoee UT013 PROJECT: SCALE: ipa -- ` CITY OF O C O E E N.T.S. � _ X UTILITIES DEPARTMENT �Q \ SHEET: DATE %/ ///% ' p\� �\Uu' 1800'A. D. Mims Rd. : "rU= 1 Ocoee, FI. 34761 July 2019 - �IIIIIII�IIIII(III/�����9' �P"'t\nu llll���ll'1111�� 905-3159 24" #4 bar with 2" r concrete cover #„ D / 24" Valve I.D. Marke)h C�tylipPEN /—(See — Collar See note 5 See nootf e 4) Finished Actuating Nut for Valve Adjustable cast iron valve box Valve box shall rest on Adjustment Ring bedding rock, not on :i'___�valve or pipe, and shall — Valve be centered on � operating nut. 6" FDOT#57 NOTES: 1. PVC extensions shall not be used on valve box. 2. The actuating nut for valves shall be no deeper than 24" from ultimate finished grade. 3. Where valve nut is more than 36" below grade, valve assembly shall include center spacing guide or extension as approved by the City. 4. Valve collar shall be 24" x 24" x 6" and concrete for collar shall be fc' of 3,000 psi minimum @ 28 days for non -pavement areas. 5. Valve Marker shall be a 2" CD2B-U Bronze Marker or approved equal and shall include main type, size, material, turns to open or close valve, and direction of rotation. Valve Box and Cover Detail N.T.S. ocoeeuraos North Cumberland Lift Station #69 64 Construction Project GD19 Station Details 15 of Is Charles K. Smith, P.E. Finished Restraint Pipe and End Cap Tapped End Cap 2" Brass Couplingw NOTES Valve Box and Cover (See UT009) 2" Blue Polyethylene Pipe Cross Section Corporation Stop & Fittings (normally AWWA Type open) CC Threads To #10 THHN Crushed stone 6" thick Tracing Wire, extending 2" beyond box Color to Match Service 30 I1to 45' v( 1 1. All pipes and fittings shall be schedule 40 brass or equivalent with threaded (NPT) joints except where denoted otherwise. 2. All pipe and fittings shall be In accordance with City Standards for the applicable service provided. 3. Pipe restraints shall be in accordance with City Standard Details UT004 for PVC/HDPE Pipe or UT005 for Ductile Iron Pipe. N.T.S. —Double Strap Water Main Stainless Steel Saddle Tapping Section NOTES: PVC/HDPE Restraint Table Minimum Length (FT) to be Restrained on each side of Fitting(s) Brass Corporation Pipe Size 4" 6" 8" 10" 1 12" 16" 20" Stop (1" Min.) 18 24 3238 44 55 74 45' Bend #10 THHN Tracing U -Branch Brass Horn 31 22 1/2" Bend 10 10 10 10 10 11 Wire to Match Use (1" x 3/4" x 3/4") 90' Angled 10 10 10 10 10 10 10 In Color Installed Upright Curb Stops at 167 Curb Stop - Ends of Horn published by DIPRA, with the following assumptions: Z (See Note 3) Double Meter Box W w (traffic rated) Coll Excess Double Meter 2" Brass Coupling Service Polyethylene Tracing Wire in Box Box and Water Tubing Meter (By City) Single Meter Double Meter Configuration Box and Water Meter (By City) 1 Service View with Single Meter Corporation Stop & Fittings (normally AWWA Type open) CC Threads To #10 THHN Crushed stone 6" thick Tracing Wire, extending 2" beyond box Color to Match Service 30 I1to 45' v( 1 1. All pipes and fittings shall be schedule 40 brass or equivalent with threaded (NPT) joints except where denoted otherwise. 2. All pipe and fittings shall be In accordance with City Standards for the applicable service provided. 3. Pipe restraints shall be in accordance with City Standard Details UT004 for PVC/HDPE Pipe or UT005 for Ductile Iron Pipe. N.T.S. —Double Strap Water Main Stainless Steel Saddle Tapping Section NOTES: PVC/HDPE Restraint Table Minimum Length (FT) to be Restrained on each side of Fitting(s) Fittings Pipe Size 4" 6" 8" 10" 1 12" 16" 20" 90° Bend 18 24 3238 44 55 74 45' Bend 10 10 13 16 18 23 31 22 1/2" Bend 10 10 10 10 10 11 15 11 1/4° Bend 10 10 10 10 10 10 10 Plug or Branch of Tee 30 47 64 81 98 133 167 NOTES: 1. The restraint values as Indicated by the "Restraint Table" are minimum Service, Polyethylene values. Design engineer shall be responsible for confirming field conditions, Tubing, 1" min. and make adjustments accordingly. 2. All fittings shall have restrained joints unless otherwise indicated. 3. No restraints required if continuous pipe length to fitting is greater than (407) 905-3159 value provided in "Restraint Table" above. 4. Where two or more fittings are laid in-line, use greatest restraint length for 5. coverage. For in-line valves and through run of tees: outside limits of restrained joints from other fittings need not be restrained unless otherwise indicated. 6. Lengths shown in the table have been calculated In accordance with the procedures outlined in "Thrust Restraint Design for Ductile Iron Pipe" as published by DIPRA, with the following assumptions: 1. All fittings shall be brass with compression -pack joint type connections. 2. No service line shall extend or terminate under a driveway. 3. Meter end of service shall terminate with curb stop (90°) for single service and dual horn and curb stops (90')for dual services. 4. Meter end of service shall terminate 3' past meter location where service shall, unless directed otherwise, extend 3' above finished grade tied to a 2" x 4" x 4' stake. If directed, service connection shall be buried and located with an 2" x 4" x 4' painted marker. Stake or marker shall Indicate lots) to be served. 5. Concrete curb shall be marked (stamped or saw -cut) with "W" locating service. 6. Service connection to the main shall use approved saddle, and tapping of main shall be by a method where a solid coupon is removed. 7. Services installed under finished or existing pavement shall be directionally drilled. 8. Upon approval, direct tap (no saddle) may be used on Ductile Iron Pipe. ' 9. Service color shall be blue for potable water and purple (magenta) for reclaimed water. Utility (Water &.Reclaim) Service Connection Detail N.T.S. Cccee UT206 SCALE: s =_`_"� CITY OF OCOEE. PROJECT: N.T.S. UTILITIES DEPARTMENT DATE: DATE:rrq/�/ 1800 A. D. Mims Rd. Ocoee, FL 34761 SHEET: July 2019 (407) 905-3159 Working Pressure: 150 PSI Soil Designation: SM (Silty Sand, Sand -Silt Mix.) Laying Conditions: 5 7. For pipe sizes not included' in the Restraint Table or pipe material not adhering to given conditions, design engineer shall determine and specify pipe lengths which shall be approved by the City. PVC/HDPE Restraint Table N.T.S. 0... UT104 SHEET North Cumberland Lift Station #69. Construction Project GD3 Station Details 17 of 18 Charles K. Smith, P.E. n, Kin, gQA19 Crown trench In — unimproved areas (3" min.) Clean Rock Bedding (See Notes 2 and 6) Varies on *a I Pioe- I *a *a See Note 3 Existing 12" (typ ) Undisturbed Earth NOTES: 1. Pipe bedding material and trench backfill shall be select common (clean) fill compacted to 95% (98% in roadway) of the maximum density as per AASHTO T-180. 2. Contractor shall install crushed rock (or equivalent bedding material) where pipe bedding does not provide solid support (yielding or plastic). Depth of material shall be a minimum of 6", or as needed, to provide non -yielding support for the pipe. All unsuitable material shall be removed from pipe bedding unless special provisions are approved by the City. 3. Excavated trench width at pipe haunch shall be sufficient in size for haunch compaction, but shall be no greater than 15" on each side of pipe for pipes less than 24" In diameter (24" for pipes 24" In diameter or greater.) 4. Water shall not be permitted in trench line during construction. 5. Pipe line shall be installed with bell fitting facing upgrade. 6. Gravity sewer shall have a 6" minimum rock bed. N.T.S. E 1 Cross Section g Grade imum Transverse Section NOTES: 1. All pipe shall Include the Installation of #10 THEN copper tracing wire capable of detection by cable locating equipment. 2. Tracing wire shall be buried directly above the transverse centerline of the pipe. 3. End(s) of the locating wire shall be such that wire can be accessed by locating equipment assessing the wire in a valve vault or blow -off box. Wire is required to extend 12" minimum above finished grade. 4. - Unless approved by the City, early warning tape indicating the type of pipe shall be required. 5. All directional drill pipe shall have locating wire attached to the top of pipe and shall remain on the lop of the pipe during installation. 6. All service lines shall have locating wire placed on the pipe as described in City of Ocoee detail UT206 "Utility Service Connection" 7. All wire splices shall be completed with twist -on type wire nuts with gel or grease filled moisture seal. 8. All tracing wire installation shall be tested and verified for continuity by the contractor prior to final acceptance Pipe Locating Wire Detail N.T.S.Ocoee UT010 � PROJECT: SCALE:'I---_-� CITY OF OCOEE N.T.S. UTILITIES DEPARTMENT \ \ - SHEET: DATE: •q//��%�/�/////���////��/ /� \���\\p�1600 A. D. Mims. Rd. IIIIII����illll��lll�in��o. : a\\\\ ���11''11�\\� Ocoee, Fl. 34761 July 2019 (407) 905-3159 3 Wire Df Pipe. Drill hole in Valve 3" t q" from top Provide one continuous loop o: tracing wire with 24" of excess and coil excess tracing wire In valve box #10 THHN Solid NOTES: 1. All pipe shall be installed with # 10 THEN solid copper tracing wire. Tracing wire must be installed directly above the pipe In a continuous circuit. 2. Tracing wire shall cover all main, pipe, branches (including fire hydrants) and service connections. 3. Tracing wire shall extend a minimum of 12" above grade at required - intervals and/or valve lids. 4. Tracing wire shall be coiled and placed in a valve box and shall be easily accessible. 5. At dead ends of mains, pipe, and/or service, the tracing wire shall be placed in a properly identified cast Iron valve box (Valve Box and Cover. Detail UT009). Tracing Wire Location Detail N.T.S. Ocoee UTOi2 North Cumberland Lift Station #69 Construction Project GDStation Details 12 of 1R ENGINEER Charles K. Smith, P.E.