HomeMy WebLinkAboutItem 03 Approval of the Large Scale Final Site Plan (FSP) for Lake Lilly Apartments 0.ket,
• 1r
ocoee
florlda
AGENDA ITEM COVER SHEET
Meeting Date: November 2, 2021
Item # .3
Reviewed By:
Contact Name: Michael Rumer Department Director:
Contact Number: 407-554-7083 City Manager:
Subject: Lake Lilly Apartments
Large Scale Final Site Plan
Project# LS-2021-004
Commission District#3 — Richard Firstner
Background Summary:
Heller Brothers Groves currently owns several parcels within the City and has entitlements on these properties
based on past purchase agreements for right-of-way in lieu of eminent domain, vesting certificates, and an
approved PSP/FSP for West End Professional Park. More specifically, the West End Professional Park is located
on the south side of Old Winter Garden Road (FKA Professional Parkway) and is entitled to a Light Industrial
subdivision development with a zoning and land use of Light Industrial (I-1). Due to the proximity of the property
to Target Areas within the Community Redevelopment Agency (CRA), the City desires to foster a better-built
environment that will be beneficial to the City, CRA, and adjacent properties. In lieu of building out to its potential
as a light industrial development, the City has been negotiating on the future development program with Heller
Brothers Groves.
The City of Ocoee and Heller Brothers Groves executed a Development Agreement on October 6, 2020, which
permitted multi-family residential as a permitted use in a mixed-use development.
The surrounding Future Land Use Designation and Zoning are as follows:
DIRECTION: FUTURE LAND USE/JURISDICTION EXISTING LAND USE/ZONING
North Commercial/Industrial I City of Ocoee Retail/Office
East Light Industrial/City of Ocoee Vacant Industrial Lots
South Turnpike Florida Turnpike
West Commercial/Light Industrial Urgent Care/City Pond
Discussion:
The Lake Lilly Apartments development is proposing 410 luxury multi-family residential dwellings units on
approximately 16.56 acres. The development will consist of six (6) phases as reflected in sheet C010 as follows:
• Phase 1: 30 units (Townhome Buildings 1 and 2)
• Phase 2: 45 units (43 units in Building 1 and 2 units in Carriage 1) as well as clubhouse and other
amenities
• Phases 3, 4 & 5: 191 units (Buildings 2, 3, and 4)
• Phase 6: 144 units (139 unifs in Building 5 and 4 units in Carriages 2 and 3)
Buildings 1 through 5 will be four(4) stories, and the townhome-style buildings and carriage buildings will be three
(3) stories. The proposed development will provide 721 parking spaces, of which 12 spaces are proposed to be
provided beneath the carriage units, and 20 spaces are proposed to be provided underneath the townhome units.
Furthermore, the development consists of a mixture of bedroom counts as follows: 82% one (1) and two (2)
bedroom units, 10% three (3) bedroom units, and the remaining will be studio units.
The project will have two (2) access points. The main access/entrance will be off of Old Winter Garden Road,
and the second access point will be off of Professional Center Blvd. Utilities will be extended to the site from the
north. Stormwater will be held in an existing permitted Master Stormwater pond.
Issue:
Should the Honorable Mayor and City Commission approve the Final Site Plan for the proposed Lake Lilly
Apartments located at 2802 Old Winter Garden Road?
Development Review Committee Recommendation:
The Development Review Committee (DRC) has reviewed the Large-Scale Final Site Plan for consistency with
adopted Engineering Design. The existing SJRWMD Drainage Permit is still valid for this development. The Utility
Department is still reviewing for separation requirements for water and sewer lines, but no adjustments to the
plans will be required.
Staff Recommendation:
Based on the analysis provided in this staff report and the recommendations of the DRC, Staff recommends that
the Honorable Mayor and City Commission approve the Large-Scale Final Site Plan for the Lake Lilly Apartments.
Attachments:
Location Map
Zoning Map
Aerial
Large Scale Final Site Plan for Lake Lilly Apartments
Renderings
Financial Impact:
None
Type of Item: (please mark with an "x")
Public Hearing Fier Clerk's Dept Use:
Ordinance First Reading Consent Agenda
Ordinance Second Reading Public Hearing
Resolution Regular Agenda
X Commission Approval
Discussion&Direction
Original Document/Contract Attached for Execution by City Clerk
Original Document/Contract Held by Department for Execution
Reviewed by City Attorney N/A
Reviewed by Finance Dept. N/A
Reviewed by () N/A
2
LAKE LILLY - FINAL SUBDIVISION PLAN
LOCATION MAP
�o
G
• '- of N,aine Street
E
L
-, V O U /
/
gyp. LAKE BENNET C
�c oC
Il � '
— Q -
c I W C I • .vim J �o
U
111W___I ri.
a .. ...k
..,.••11
r
MIRIP
- _ _ _ / UNNAMED AK
Ulf AMED CANAL
r.,44-(4,-: .. ���� o
law . �
fit IIIIIIIII IIIIIIIII LAKE LILLY
0 --t
I
J •MAIM:•ulevard
co
L' 7ifFiE���v
LAKE PEARL
_
SIN POuleva a� o a
- rd . DriVe7 III it i -llllllfll_
I l flTfil f11
, = = o
0 0 4 itid I I r
'.0'�r
l;f e. ,41M' r y 3 LAKE BONNE'
Lake Lilly - Final Subdivision Plan
Aerial Map
,�"'�, . d- -' ,.,. _ �d'1^ ._ . _nfr.,�, •. w..,;,..-- -r '°fir},. "'..
% I .'- i; ,• 0. ,'. •-. ..-- ' . lra...: ' T.; 11, : . - - - 4.v.* . .a* — fir . -- -. ... ..,*‘,...: - ..L., ,4. ": , /I.
f r A
,.,.,•,,...,..,,•.,.,...-,,?';.-'A.i,‘....,,.:-. -...„,k:^.::::?,l.1_4..t1.,4.,.N,IIO,e,.-..,.. • ' '.'..•-. . ,.,.-.
.fi.4:44 t,.
7 7
''‘ vr.
_L'4iil,7d:'.,,,4,.._.21
4404-
rr
S''r'.:,.I -11-.m 7.4-::.' ' -.-
111 r 'i, ' .• 7 : _ * \j Fn1t : 1w t +
.:::::'4'•.,...:,-.'
y,�,, i 5
Y
... -
I: - f," '
h. �. ,
!!1C
`-. 4'f 14X
,. 3 4k. :' ,,a:a �,
.r 4 ..!
•
,. _.. # ,
, i .„;,_ 00: r ;, .,..,
•
, . t, - ,p
i kk0
F
., Y 0 150 300 600
����M1����• .. � �'`: r r, —{- f N i === iimmo Feet
Lake Lilly - Final Subdivision Plan
Surrounding Zoning Map
0 41+‘
Ocoee
Honda
Development Services ,< —
Department
U k.P -
0 210 420 840 INY
MilIFeet I I
•.t
i, o
Created: July 2021
- C-2 11111limi-
3)1
QSubject Property1 _ .,
Zoning Classification: '_
General Agricultural (A-1) r
Suburban (A-2)
1
Single-Family Dwelling (R-1AAA) ---- l ..
Single-Family Dwelling (R-1AA) IF
or' (-
Single-Family Dwelling (R-1A) _ >•. odd_ TUr rAMEDCANAL
ak
Single-Family Dwelling (R-1) = - - np��o
One- &Two-Family Dwelling (R-2) : •
IIIIII Multiple-Family Dwelling (R-3) =:s:_:.e _,
= LAKE LILLY
Mobile Home Subdivision (RT-1) = '==
= Professional Offices & Services (P-S) 14:s
•1111111 Migniii
Restricted Manufacturing � ♦� • 7)
���
&Warehousing (1-1) �� 'Irk. , . I.
General Industrial (1-2) '��'�� •�511�11% ii LAKE PEARL �1
II
KS Commercial (PUD) P 42 ■�� 1p, ij-- ill.
Mg Low Density(PUD) KaYiii«y j• s V, 1• �,
ing Medium Density (PUD) �11��� �14111�, Mil ��
NM High Density (PUD) P 11111.0 ■ii iitlliliiil1 �g ile 1w
11111 Public Use(PUD) Ull1111111111111iIIa h01m 7 Bij�liArllill
//i Unclassified ::... = I + 1 /%1 IrraMMEIM
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;31;29.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;31;53.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;31;66.15(11(
KA
TAK
YAdetoNsA
NALP
LORTNOCNOISORE
C006
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;32;1:.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;32;33.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;32;46.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;32;59.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;33;13.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;33;26.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;33;3:.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;33;54.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;33;67.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;34;21.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;34;35.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;34;49.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;34;63.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;35;18.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;35;32.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;35;46.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;35;5:.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;36;14.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;36;28.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;36;42.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;36;57.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;37;12.15(11(
NALP
GNISAHPYTILITU
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;37;26.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;37;39.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;37;54.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;37;68.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;38;22.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;38;36.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;38;4:.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;38;67.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;39;21.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;39;36.15(11(
SLIATEDETIS
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;39;4:.15(11(
5
2
#!.
9
2
HFOFSBM!OPUFT;
TJEFXBML!OPUFT;
3#!Njo/-4#!Nby/
qq
jj
ss
uu
TT
zz
uu
jj
mm
jj
uu
VV
sPttbsH
/uwbQ
zujmjuV
3qjsuT
q
n
b
S
q
n
b3(.1#!Efufdubcmf!Xbsojoht
2
S332;
1
qnbS
/
3
1
DS.G
1
Sbnq
3(.1#!Efufdubcmf!Xbsojoht/
7!Njo/Tjefxbml1
5(.7#!Njo/
QMBO!WJFX
7(.1#
JTPNFUSJD!WJFX
S
/
y
#$5!Cbst-!29#!Mpoh)Uxp!Qfs!Hvbse*
#
b
1
1
.
.N
(
(
3
6
Tjefxbml!Dvsc)Xifsf!Ofdfttbsz*
23#)²*
DPODSFUF!CVNQFS!HVBSE
#!Ipmft
5/ybN#7
4
q
Tjefxbmln
bTjefxbml!Dvsc
S>3#Dbtu!PsSvccfe
S-/ojN#6
Qjudi!Pqujpobm
#!Ps
9
6
q
n
Tjefxbml
b
S
3(.1#!Efufdubcmf!Xbsojoht
32;2
S
qnb
Sbnq
6!Njo/
5!Njo/
DS.F
Tjefxbml
9#!Njo/-
:#!Nby/
QMBO!WJFX
TJEFXBML!DVSC!SBNQT!DS.F!'!DS.G
JTPNFUSJD!WJFX
S
#
5#!Njo/-6#!Nby/
1
.
(
3
3(.1#!Efufdubcmf!Xbsojoht
3#!Njo/-5#!Nby/
+/ojN#7
3
/euT#8
2
+/ojN#7
3
S/euT#8
2
#
5
4
+
2(.3#
+/ojN#7
S
#
35
/euT#8
2
4
+
#!Fyq/!Kpjou5
#7
32
22(.3#
Dvsc!Boe!Hvuufs
S
31(!S!Ps!Bt!Tipxo!Po!Qmbot
#
5
5
#7
4
2
+
2(.3#
2(.21#
D
4(.7#
D
5
#7
C
2
6(.1#
C Wbmmfz!Hvuufs
2(.21#
TFDUJPO!DD
3
#8
4(.1#2
TFDUJPO!CC
QMBO
S
#
4
TFDUJPO!BB
2(.21#
9#
S
7#
#
2(.7#
3
S
B
S
B#
4
5#
4
#7
3
#89#
S#1.(2
27#
#
3
#12.(2
Gvuvsf!Dvsc!Boe
Hvuufs!Dpotusvdujpo
#3.(2
#7
#1.(2
+/ojN#7
3
/euT#8
2
+S
#
5
4
2(.7#
S
#
43(.1#
UZQF!G
9#
7#S
#
3
#7#7
#1.(2
SLIATED
EGANIARDDNAETIS
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;39;64.15(11(
foufst!b!3(.1#!xbmm*
Sfdpnnfoefe!Nbyjnvn!Qjqf!Tj{f;3(.1#!Xbmm!.!29#!Qjqf
4(.2#!Xbmm!.!35#!Qjqf!)29#!xifsf!bo!29#!qjqf
4(.1#!Xbmm!.!35#!Qjqf
Sfdpnnfoefe!Nbyjnvn!Qjqf!Tj{f;5(.7#!Xbmm!.!47#!Qjqf
#7
#7#2.(4
9#
utbdfsQ#9
#2.(4#9 XXG
Q.J.D
9#6#6#7#
GSBNF!'!HSBUFFzfcpmu$5!Cbst!A!23#!Dus/
JO!NPSUBSCsjdlTff!Joefy!536.112
GSBNF!'!HSBUF XXG
JO!NPSUBSFzfcpmu
Tff!Joefy!536.112
Fzfcpmu)Tff!Ubcmf!4*
$5!Cbst!A!23#!Dus/Tff!Joefy!536.112Ipsj{/!Xbmm!Sfjog/
23#
$5!Cbst!A!23#!Dust/$5!Cbst!A!23#!Dust/)Tipsu!Cbst*
NBY/!TQBDJOH
CBST
D.J.QQsfdbtu
##
D.J.QQsfdbtu
33
D.J.QQsfdbtu
22
7#
23#6
7
NBY/!TQBDJOH
CBST
9#
7#Dfoufs!Pg!Cpy
Tub/0Pggtfu!Mpdbujpo
9#7#
9#7#
1/31
BSFB
1/311/311/351/48
BSFB
)jo/³0gu/*
/mD#3)jo/³0gu/*
3(.1#4(.1#
3(.1#4(.1#
4(.1#
utbdfsQ
/mD#3
UZQF!F
5(.5#!D.J.Q5(.1#!Qsfdbtu
#7.(5
#7#7
4#!Dm/Q.J.D5(.5#!D.J.Q
5(.1#!Qsfdbtu
4(.5#!D.J.Q4#!Dm/
4(.1#!Qsfdbtu
#7.(5
#9
#9
4(.5#!D.J.Q
4(.1#!QsfdbtuB7
B23
D7/6
C6/6
9#
7#
9#7#
9#7#
TDIFEVMF
B23
#3
#7
*/ybN(62)utbdfsQ
TDIFEVMF
tfjsbWiuqfEmmbX#9
Q.J.D
#7
*/ybN(62)
utbdfsQ
utbdfsQ#7.(6
1(.6(
XBMM
1(.8/6(
utbdfsQ#2.(5
EFQUI 8/6(.21(21(.26(
Q.J.D#12.(6
Q.J.D
tfjsbWiuqfEmmbX#9
Q.J.D#6.(5
XBMM
1(.26(
EFQUI
NOTES:
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;3:;19.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;3:;34.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;3:;48.15(11(
Ejhjubmmz!tjhofe!cz!Bcevm!BmlbeszEbuf;!3132/19/21!23;3:;63.15(11(
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
OCOEE, FLORIDA
mv
4406.21
08-11-2021
RENDERING
Ejhjubmmz!tjhofe!cz!Dibsmft!M!Dibsmbo;B121:C41111128188:CGB7911141:21EO;!DO>Dibsmft!M!Dibsmbo;B121:C41111128188:CGB7911141:21-PV>Dibsmbo!Cspdl!Bttpdjbuft-!PV>JefoUsvtu-!PV>FDB-!P>V/T/!Hpwfsonfou-!D>V
TEbuf;!3132/19/22!26;54;34.15(11(
LAKE LILLY APARTMENTS
4406A2.00
CONCEPTUAL
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
FSP Submittal 08-11-2021
1
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
ONE
OCOEE, FLORIDA
NW
4406.21
08-11-2021
LAKE LILLY APARTMENTS
4406A2.11
BUILDING TYPE
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
TYPICAL STUCCO NOTES
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".AESTHETIC JOINTS WHERE JOINTS
SHOWN ON ELEVATION EXCEED THE
B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" INC) CONTROL JOINTS SHALL BE INSTALLED AT FLOOR LINES.D) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL JOINTS, DO NOT
CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT REQUIREMENTS OF ASTM C-1063. AS SUCH STUCCO CONTRACTOR HASOPTION OF ONLY CUTTING JOINTS REQUIRED TO COMPLY WITH ASTMC-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDAREAS.METAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERASTM
C-1063.CONTROL JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THE
FOLLOWING REQUIREMENTS:
2.3.
1.
3
5
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMCONDITIONS.PROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER RODDOORS.
(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /
SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIOR
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR EDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.ALL
ATTACHMENT AND PENETRATION THROUGH THE EXTERIORCLADDING SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERINTRUSION.EXTERIOR WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL
DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELALUMINUM.ALL ROOF TO WALL TERMINATIONS MUST HAVE SADDLE FLASHING ATROOF PARAPET TERMINATION
8.9.
10.11.12.13.14.
3
TYPICAL ELEVATION NOTES
1
" PER FOOT.
14
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
4
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDSTONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHERALL
EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED OF SEALANT.ALL BUILDING MOUNTED
EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTEROF MOUNTING AND WATERPROOFING TO ARCHITECT FOR APPROVAL. PLINTH
BARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE BARRIER.REFER TO KEYED NOTES.EXTERIOR FINISH IS APPLIED AND PAINTED.
IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR SHALL SUBMIT METHODBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYFROM UNIT FOR DRAINAGE AT ALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
SLOPE AWAY FROM BUILDING.
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR AND
4.
2.3.
1.
7.
5.6.
2
2
ELEVATION KEY NOTES
7
STONE VENEER SYSTEMSTANDING SEAM METAL ROOFING
6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESANODIZED ALUMINUM FIBER CEMENT ACCESSORIESLIGHT FIXTUREALUMINUM GUARDRAILSPREFABRICATED
ALUMINUM AWNINGGLAZINGGUTTER SYSTEM
123456789
6
1011
8
1
2
3
5
2
7
9
9
1
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
ONE
OCOEE, FLORIDA
NW
4406.21
08-11-2021
LAKE LILLY APARTMENTS
4406A2.12
BUILDING TYPE
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
2
TYPICAL STUCCO NOTES
AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE C) CONTROL JOINTS SHALL BE INSTALLED AT FLOOR LINES.JOINTS, DO NOT CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT AESTHETIC JOINTS
WHERE JOINTS SHOWN ON ELEVATION EXCEED THEOPTION OF ONLY CUTTING JOINTS REQUIRED TO COMPLY WITH ASTMC-1063.
B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" IND) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL REQUIREMENTS OF ASTM C-1063. AS SUCH STUCCO CONTRACTOR HAS
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AAREAS.ASTM C-1063.
MIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDMETAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERCONTROL JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THEFOLLOWING
REQUIREMENTS:
2.3.
1.
1
9
6
8
4
CONDITIONS.
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMPROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER ROD(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /DOORS.
1
SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIORALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORCLADDING SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERINTRUSION.ALUMINUM.ALL
ROOF TO WALL TERMINATIONS MUST HAVE SADDLE FLASHING AT
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR EDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.EXTERIOR
WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELROOF PARAPET TERMINATION
8.9.
10.11.12.13.14.
7
TYPICAL ELEVATION NOTES
3
5
" PER FOOT.
1
4
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,STONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHERALL EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST
BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED OF SEALANT.ALL BUILDING MOUNTED EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTER
CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDBARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE
BARRIER.REFER TO KEYED NOTES.EXTERIOR FINISH IS APPLIED AND PAINTED. IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR SHALL SUBMIT METHODOF MOUNTING AND WATERPROOFING
TO ARCHITECT FOR APPROVAL. PLINTHBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
FROM UNIT FOR DRAINAGE AT
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR ANDSLOPE AWAY FROM BUILDING.
2.3.4.
1.
7.
5.6.
2
1
ELEVATION KEY NOTES
STONE VENEER SYSTEM6" REVEAL FIBER CEMENT LAP SIDINGANODIZED ALUMINUM FIBER CEMENT ACCESSORIESALUMINUM GUARDRAILSGLAZINGSTANDING SEAM METAL ROOFINGGUTTER SYSTEM
FIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESLIGHT FIXTUREPREFABRICATED ALUMINUM AWNING
123456789
1011
9
8
6
1
7
3
43
5
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
TWO
OCOEE, FLORIDA
NW
4406.21
08-11-2021
LAKE LILLY APARTMENTS
4406A2.21
BUILDING TYPE
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
8
TYPICAL STUCCO NOTES
AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" INC) CONTROL JOINTS SHALL BE INSTALLED AT FLOOR LINES.D) METAL LATH
SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL JOINTS, DO NOT CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT AESTHETIC JOINTS WHERE JOINTS SHOWN ON ELEVATION EXCEED THEREQUIREMENTS OF ASTM
C-1063. AS SUCH STUCCO CONTRACTOR HASOPTION OF ONLY CUTTING JOINTS REQUIRED TO COMPLY WITH ASTMC-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDAREAS.METAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERASTM
C-1063.CONTROL JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THE
FOLLOWING REQUIREMENTS:
2.3.
1.
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
3
5
CONDITIONS.
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMPROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER ROD(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /DOORS.
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIOREDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE
SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.ALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORCLADDING SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERINTRUSION.EXTERIOR
WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELALUMINUM.ALL ROOF TO WALL TERMINATIONS MUST HAVE SADDLE FLASHING ATROOF PARAPET TERMINATION
8.9.
10.11.12.13.14.
TYPICAL ELEVATION NOTES
8
" PER FOOT.
14
6
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDSTONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHERALL
EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED OF SEALANT.ALL BUILDING MOUNTED
EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTEROF MOUNTING AND WATERPROOFING TO ARCHITECT FOR APPROVAL. PLINTH
BARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE BARRIER.REFER TO KEYED NOTES.EXTERIOR FINISH IS APPLIED AND PAINTED.
IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR SHALL SUBMIT METHODBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYFROM UNIT FOR DRAINAGE AT ALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
SLOPE AWAY FROM BUILDING.
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR AND
2.3.4.
1.
7.
5.6.
8
2
2
ELEVATION KEY NOTES
STONE VENEER SYSTEM6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESANODIZED ALUMINUM FIBER CEMENT ACCESSORIESLIGHT FIXTUREALUMINUM GUARDRAILSPREFABRICA
TED ALUMINUM AWNINGGLAZINGSTANDING SEAM METAL ROOFINGGUTTER SYSTEM
7
123456789
1011
1
3
5
7
9
9
21
1
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
TWO
OCOEE, FLORIDA
NW
4406.21
08-11-2021
LAKE LILLY APARTMENTS
4406A2.22
BUILDING TYPE
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
2
9
TYPICAL STUCCO NOTES
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".C) CONTROL JOINTS SHALL BE
INSTALLED AT FLOOR LINES.JOINTS, DO NOT CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT AESTHETIC JOINTS WHERE JOINTS SHOWN ON ELEVATION EXCEED THEOPTION OF ONLY CUTTING JOINTS REQUIRED
TO COMPLY WITH ASTMC-1063.
B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" IND) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL REQUIREMENTS OF ASTM C-1063. AS SUCH STUCCO CONTRACTOR HAS
AREAS.ASTM C-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDMETAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERCONTROL
JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THEFOLLOWING REQUIREMENTS:
2.3.
1.
6
8
8
4
3
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
5
1
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMCONDITIONS.PROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER RODDOORS.
(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /
SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIORALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORALUMINUM.ALL ROOF TO WALL TERMINATIONS MUST HAVE SADDLE FLASHING AT
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR EDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.CLADDING
SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERINTRUSION.EXTERIOR WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELROOF PARAPET TERMINATION
8.9.
710.11.12.13.14.
8
TYPICAL ELEVATION NOTES
" PER FOOT.
14
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,STONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHER
CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDBARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE
BARRIER.REFER TO KEYED NOTES.ALL EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED
OF SEALANT.ALL BUILDING MOUNTED EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTEREXTERIOR FINISH IS APPLIED AND PAINTED. IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR
SHALL SUBMIT METHODOF MOUNTING AND WATERPROOFING TO ARCHITECT FOR APPROVAL. PLINTHBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
FROM UNIT FOR DRAINAGE AT
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR ANDSLOPE AWAY FROM BUILDING.
2.3.4.
1.
7.
5.6.
3
5
2
ELEVATION KEY NOTES
STONE VENEER SYSTEMANODIZED ALUMINUM FIBER CEMENT ACCESSORIESALUMINUM GUARDRAILSSTANDING SEAM METAL ROOFING
6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESLIGHT FIXTUREPREFABRICATED ALUMINUM AWNINGGLAZINGGUTTER SYSTEM
123456789
1011
1
7
9
43
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
TWO
OCOEE, FLORIDA
NW
4406.21
08-11-2021
LAKE LILLY APARTMENTS
4406A2.23
BUILDING TYPE
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
TYPICAL STUCCO NOTES
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".AESTHETIC JOINTS WHERE JOINTS
SHOWN ON ELEVATION EXCEED THE
B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" INC) CONTROL JOINTS SHALL BE INSTALLED AT FLOOR LINES.D) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL JOINTS, DO NOT
CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT REQUIREMENTS OF ASTM C-1063. AS SUCH STUCCO CONTRACTOR HASOPTION OF ONLY CUTTING JOINTS REQUIRED TO COMPLY WITH ASTMC-1063.
7
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDAREAS.METAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERASTM
C-1063.CONTROL JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THEFOLLOWING REQUIREMENTS:
2.3.
1.
9
6
8
3
2
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMCONDITIONS.PROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER RODDOORS.
(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /
SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIOR
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR EDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.ALL
ATTACHMENT AND PENETRATION THROUGH THE EXTERIORCLADDING SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERINTRUSION.EXTERIOR WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL
DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELALUMINUM.ALL ROOF TO WALL TERMINATIONS MUST HAVE SADDLE FLASHING ATROOF PARAPET TERMINATION
8.9.
10.11.12.13.14.
5
TYPICAL ELEVATION NOTES
" PER FOOT.
14
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDSTONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHERALL
EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED OF SEALANT.ALL BUILDING MOUNTED
EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTEROF MOUNTING AND WATERPROOFING TO ARCHITECT FOR APPROVAL. PLINTH
BARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE BARRIER.REFER TO KEYED NOTES.EXTERIOR FINISH IS APPLIED AND PAINTED.
IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR SHALL SUBMIT METHODBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYFROM UNIT FOR DRAINAGE AT ALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR ANDSLOPE AWAY FROM BUILDING.
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
4.
2.3.
1.
5.7.
6.
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
9
ELEVATION KEY NOTES
STONE VENEER SYSTEMSTANDING SEAM METAL ROOFING
6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESANODIZED ALUMINUM FIBER CEMENT ACCESSORIESLIGHT FIXTUREALUMINUM GUARDRAILSPREFABRICATED
ALUMINUM AWNINGGLAZINGGUTTER SYSTEM
123456789
1011
2
3
3
5
8
8
15
1
2
7
7
9
7
6
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
OCOEE, FLORIDA
THREE RMR
4406.21
08-11-2021
LAKE LILLY APARTMENTS
4406A2.31
BUILDING TYPE
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
TYPICAL STUCCO NOTES
AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" INC) CONTROL JOINTS SHALL BE INSTALLED AT FLOOR LINES.D) METAL LATH
SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL JOINTS, DO NOT CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT AESTHETIC JOINTS WHERE JOINTS SHOWN ON ELEVATION EXCEED THEREQUIREMENTS OF ASTM
C-1063. AS SUCH STUCCO CONTRACTOR HASOPTION OF ONLY CUTTING JOINTS REQUIRED TO COMPLY WITH ASTMC-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDAREAS.METAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERASTM
C-1063.CONTROL JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THE
FOLLOWING REQUIREMENTS:
2.
3.
1.
1
9
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
2
3
CONDITIONS.
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMPROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER ROD(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /DOORS.
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIOREDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE
SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.ALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORCLADDING SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERINTRUSION.EXTERIOR
WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELALUMINUM.ALL ROOF TO WALL TERMINATIONS MUST HAVE SADDLE FLASHING ATROOF PARAPET TERMINATION
8.9.
10.11.12.13.14.
5
1
7
TYPICAL ELEVATION NOTES
9
" PER FOOT.
1
4
3
5
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDSTONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHERALL
EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED OF SEALANT.ALL BUILDING MOUNTED
EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTEROF MOUNTING AND WATERPROOFING TO ARCHITECT FOR APPROVAL. PLINTH
BARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE BARRIER.REFER TO KEYED NOTES.EXTERIOR FINISH IS APPLIED AND PAINTED.
IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR SHALL SUBMIT METHODBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
FROM UNIT FOR DRAINAGE AT SLOPE AWAY FROM BUILDING.
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR AND
2.3.4.
1.
7.
5.6.
2
7
8
6
ELEVATION KEY NOTES
STONE VENEER SYSTEM6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESANODIZED ALUMINUM FIBER CEMENT ACCESSORIESLIGHT FIXTUREALUMINUM GUARDRAILSPREFABRICA
TED ALUMINUM AWNINGGLAZINGSTANDING SEAM METAL ROOFINGGUTTER SYSTEM
123456789
1011
21
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
OCOEE, FLORIDA
THREE RMR
4406.21
08-11-2021
LAKE LILLY APARTMENTS
4406A2.32
BUILDING TYPE
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
TYPICAL STUCCO NOTES
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".AESTHETIC JOINTS WHERE JOINTS
SHOWN ON ELEVATION EXCEED THE
B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" INC) CONTROL JOINTS SHALL BE INSTALLED AT FLOOR LINES.D) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL JOINTS, DO NOT
CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT REQUIREMENTS OF ASTM C-1063. AS SUCH STUCCO CONTRACTOR HASOPTION OF ONLY CUTTING JOINTS REQUIRED TO COMPLY WITH ASTMC-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDAREAS.METAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERASTM
C-1063.CONTROL JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THE
FOLLOWING REQUIREMENTS:
2.3.
1.
43'-5 5/8"TRUSS.BRG41'-6 3/4"TRUSS.BRG32'-5 5/8"T.O. PLYWD.30'-8 7/8"TRUSS.BRG21'-7 3/4"T.O. PLYWD.19'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMCONDITIONS.PROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER RODDOORS.
(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /
SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIOR
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR EDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.ALL
ATTACHMENT AND PENETRATION THROUGH THE EXTERIORCLADDING SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERINTRUSION.EXTERIOR WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL
DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELALUMINUM.ALL ROOF TO WALL TERMINATIONS MUST HAVE SADDLE FLASHING ATROOF PARAPET TERMINATION
8.9.
10.11.12.13.14.
2
TYPICAL ELEVATION NOTES
1
" PER FOOT.
14
9
8
4
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDSTONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHERALL
EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED OF SEALANT.ALL BUILDING MOUNTED
EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTEROF MOUNTING AND WATERPROOFING TO ARCHITECT FOR APPROVAL. PLINTH
BARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE BARRIER.REFER TO KEYED NOTES.EXTERIOR FINISH IS APPLIED AND PAINTED.
IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR SHALL SUBMIT METHODBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYFROM UNIT FOR DRAINAGE AT ALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR ANDSLOPE AWAY FROM BUILDING.
6
4.
2.3.
1.
7.
5.6.
3
2
5
7
1
ELEVATION KEY NOTES
STONE VENEER SYSTEMSTANDING SEAM METAL ROOFING
6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESANODIZED ALUMINUM FIBER CEMENT ACCESSORIESLIGHT FIXTUREALUMINUM GUARDRAILSPREFABRICATED
ALUMINUM AWNINGGLAZINGGUTTER SYSTEM
123456789
1011
9
8
4
6
3
5
7
43
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
OCOEE, FLORIDA
FOUR
RMR
4406.21
08-11-2021
LAKE LILLY APARTMENTS
4406A2.41
BUILDING TYPE
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
TYPICAL STUCCO NOTES
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".C) CONTROL JOINTS SHALL BE
INSTALLED AT FLOOR LINES.JOINTS, DO NOT CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT AESTHETIC JOINTS WHERE JOINTS SHOWN ON ELEVATION EXCEED THEOPTION OF ONLY CUTTING JOINTS REQUIRED
TO COMPLY WITH ASTMC-1063.
B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" IND) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL REQUIREMENTS OF ASTM C-1063. AS SUCH STUCCO CONTRACTOR HAS
AREAS.ASTM C-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDMETAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERCONTROL
JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THEFOLLOWING REQUIREMENTS:
2.3.
1.
1
9
3
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMCONDITIONS.PROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER RODDOORS.
(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /
SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIORALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORALUMINUM.ALL ROOF TO WALL TERMINATIONS MUST HAVE SADDLE FLASHING AT
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR EDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.CLADDING
SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERINTRUSION.EXTERIOR WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELROOF PARAPET TERMINATION
8.9.
10.11.12.13.14.
5
7
TYPICAL ELEVATION NOTES
" PER FOOT.
14
8
STONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHER
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDBARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH
ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE BARRIER.REFER TO KEYED NOTES.ALL EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS
THROUGH EXTERIOR SKIN SHALL BE SET IN BED OF SEALANT.ALL BUILDING MOUNTED EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTEREXTERIOR FINISH IS APPLIED AND PAINTED. IF SEQUENCING OF CONSTRUCTIONREQUIRES
MOUNTING PRIOR TO THIS, CONTRACTOR SHALL SUBMIT METHODOF MOUNTING AND WATERPROOFING TO ARCHITECT FOR APPROVAL. PLINTHBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES
INCLUDING CULTURED STONE.
6ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
FROM UNIT FOR DRAINAGE AT
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR ANDSLOPE AWAY FROM BUILDING.
2.3.4.
1.
5.7.
6.
7
2
2
9
5
ELEVATION KEY NOTES
STONE VENEER SYSTEMANODIZED ALUMINUM FIBER CEMENT ACCESSORIESALUMINUM GUARDRAILSSTANDING SEAM METAL ROOFING
6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESLIGHT FIXTUREPREFABRICATED ALUMINUM AWNINGGLAZINGGUTTER SYSTEM
123456789
1011
3
1
21
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
OCOEE, FLORIDA
FOUR
RMR
4406.21
08-11-2021
LAKE LILLY APARTMENTS
4406A2.42
BUILDING TYPE
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
2
TYPICAL STUCCO NOTES
AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE C) CONTROL JOINTS SHALL BE INSTALLED AT FLOOR LINES.JOINTS, DO NOT CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT AESTHETIC JOINTS
WHERE JOINTS SHOWN ON ELEVATION EXCEED THEOPTION OF ONLY CUTTING JOINTS REQUIRED TO COMPLY WITH ASTMC-1063.
B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" IND) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL REQUIREMENTS OF ASTM C-1063. AS SUCH STUCCO CONTRACTOR HAS
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AAREAS.ASTM C-1063.
MIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDMETAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERCONTROL JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THEFOLLOWING
REQUIREMENTS:
2.3.
1.
1
9
8
4
6
3
CONDITIONS.
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMPROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER ROD(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /DOORS.
SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIORALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORCLADDING SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERINTRUSION.ALUMINUM.ALL
ROOF TO WALL TERMINATIONS MUST HAVE SADDLE FLASHING AT
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR EDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.EXTERIOR
WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELROOF PARAPET TERMINATION
5
8.9.
10.11.12.13.14.
7
TYPICAL ELEVATION NOTES
" PER FOOT.
1
4
2
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,STONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHERALL EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST
BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED OF SEALANT.ALL BUILDING MOUNTED EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTER
CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDBARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE
BARRIER.REFER TO KEYED NOTES.EXTERIOR FINISH IS APPLIED AND PAINTED. IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR SHALL SUBMIT METHODOF MOUNTING AND WATERPROOFING
TO ARCHITECT FOR APPROVAL. PLINTHBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
FROM UNIT FOR DRAINAGE AT
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR ANDSLOPE AWAY FROM BUILDING.
2.3.4.
1.
7.
5.6.
1
9
8
4
6
ELEVATION KEY NOTES
STONE VENEER SYSTEM6" REVEAL FIBER CEMENT LAP SIDINGANODIZED ALUMINUM FIBER CEMENT ACCESSORIESALUMINUM GUARDRAILSGLAZINGSTANDING SEAM METAL ROOFINGGUTTER SYSTEM
FIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESLIGHT FIXTUREPREFABRICATED ALUMINUM AWNING
3
123456789
1011
5
7
43
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
FIVE
OCOEE, FLORIDA
NW
4406.21
08-11-2021
LAKE LILLY APARTMENTS
4406A2.51
BUILDING TYPE
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
44'-5 5/8"TRUSS.BRG42'-6 3/4"TRUSS.BRG33'-5 5/8"T.O. PLYWD.31'-8 7/8"TRUSS.BRG22'-7 3/4"T.O. PLYWD.20'-11"TRUSS.BRG11'-9 7/8"T.O. PLYWD.10'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
44'-5 5/8"TRUSS.BRG42'-6 3/4"TRUSS.BRG33'-5 5/8"T.O. PLYWD.31'-8 7/8"TRUSS.BRG22'-7 3/4"T.O. PLYWD.20'-11"TRUSS.BRG11'-9 7/8"T.O. PLYWD.10'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
4
TYPICAL STUCCO NOTES
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".JOINTS, DO NOT CUT PAPER.
LATH IS NOT REQUIRED TO BE CUT AT AESTHETIC JOINTS WHERE JOINTS SHOWN ON ELEVATION EXCEED THE
B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" INC) CONTROL JOINTS SHALL BE INSTALLED AT FLOOR LINES.D) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL REQUIREMENTS OF
ASTM C-1063. AS SUCH STUCCO CONTRACTOR HASOPTION OF ONLY CUTTING JOINTS REQUIRED TO COMPLY WITH ASTMC-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDAREAS.METAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERASTM
C-1063.CONTROL JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THEFOLLOWING REQUIREMENTS:
2.3.
1.
1
1
2
9
9
3
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMCONDITIONS.PROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER RODDOORS.
(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /
SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIORALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORALUMINUM.ALL ROOF TO WALL TERMINATIONS MUST HAVE SADDLE FLASHING AT
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR EDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.CLADDING
SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERINTRUSION.EXTERIOR WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELROOF PARAPET TERMINATION
8.
9.
10.11.12.13.14.
5
3
TYPICAL ELEVATION NOTES
7
5
4
" PER FOOT.
14
2
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDSTONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHERALL
EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED OF SEALANT.ALL BUILDING MOUNTED
EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTEROF MOUNTING AND WATERPROOFING TO ARCHITECT FOR APPROVAL. PLINTH
BARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE BARRIER.REFER TO KEYED NOTES.EXTERIOR FINISH IS APPLIED AND PAINTED.
IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR SHALL SUBMIT METHODBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.ALL
UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
FROM UNIT FOR DRAINAGE AT
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR ANDSLOPE AWAY FROM BUILDING.
2.3.4.
1.
6
5.7.
6.
8
ELEVATION KEY NOTES
STONE VENEER SYSTEMANODIZED ALUMINUM FIBER CEMENT ACCESSORIESALUMINUM GUARDRAILSSTANDING SEAM METAL ROOFING
6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESLIGHT FIXTUREPREFABRICATED ALUMINUM AWNINGGLAZINGGUTTER SYSTEM
123456789
1011
1
2
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
FIVE
OCOEE, FLORIDA
NW
4406.21
08-11-2021
LAKE LILLY APARTMENTS
4406A2.52
BUILDING TYPE
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
44'-5 5/8"TRUSS.BRG42'-6 3/4"TRUSS.BRG33'-5 5/8"T.O. PLYWD.31'-8 7/8"TRUSS.BRG22'-7 3/4"T.O. PLYWD.20'-11"TRUSS.BRG11'-9 7/8"T.O. PLYWD.10'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
44'-5 5/8"TRUSS.BRG42'-6 3/4"TRUSS.BRG33'-5 5/8"T.O. PLYWD.31'-8 7/8"TRUSS.BRG22'-7 3/4"T.O. PLYWD.20'-11"TRUSS.BRG11'-9 7/8"T.O. PLYWD.10'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
2
TYPICAL STUCCO NOTES
3
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".C) CONTROL JOINTS SHALL BE
INSTALLED AT FLOOR LINES.JOINTS, DO NOT CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT AESTHETIC JOINTS WHERE JOINTS SHOWN ON ELEVATION EXCEED THEOPTION OF ONLY CUTTING JOINTS REQUIRED
TO COMPLY WITH ASTMC-1063.
B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" IND) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL REQUIREMENTS OF ASTM C-1063. AS SUCH STUCCO CONTRACTOR HAS
2
AREAS.ASTM C-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDMETAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERCONTROL
JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THEFOLLOWING REQUIREMENTS:
5
2.3.
1.
4
6
6
8
8
4
1
3
5
7
9
7
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMCONDITIONS.PROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER RODDOORS.
(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /
SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIORALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORCLADDING SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERALUMINUM.ALL ROOF TO
WALL TERMINATIONS MUST HAVE SADDLE FLASHING AT
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR EDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.INTRUSION.E
XTERIOR WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELROOF PARAPET TERMINATION
9
8.9.
10.11.12.13.14.
1
TYPICAL ELEVATION NOTES
" PER FOOT.
14
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,STONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHER
CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDBARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE
BARRIER.REFER TO KEYED NOTES.ALL EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED
OF SEALANT.ALL BUILDING MOUNTED EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTEREXTERIOR FINISH IS APPLIED AND PAINTED. IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR
SHALL SUBMIT METHODOF MOUNTING AND WATERPROOFING TO ARCHITECT FOR APPROVAL. PLINTHBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
FROM UNIT FOR DRAINAGE AT
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR ANDSLOPE AWAY FROM BUILDING.
2.3.4.
1.
7.
5.6.
ELEVATION KEY NOTES
STONE VENEER SYSTEMANODIZED ALUMINUM FIBER CEMENT ACCESSORIESALUMINUM GUARDRAILSSTANDING SEAM METAL ROOFING
6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESLIGHT FIXTUREPREFABRICATED ALUMINUM AWNINGGLAZINGGUTTER SYSTEM
123456789
1011
43
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
FIVE
OCOEE, FLORIDA
NW
4406.21
08-11-2021
LAKE LILLY APARTMENTS
4406A2.53
BUILDING TYPE
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
44'-5 5/8"TRUSS.BRG42'-6 3/4"TRUSS.BRG33'-5 5/8"T.O. PLYWD.31'-8 7/8"TRUSS.BRG22'-7 3/4"T.O. PLYWD.20'-11"TRUSS.BRG11'-9 7/8"T.O. PLYWD.10'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
TYPICAL STUCCO NOTES
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".AESTHETIC JOINTS WHERE JOINTS
SHOWN ON ELEVATION EXCEED THE
B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" INC) CONTROL JOINTS SHALL BE INSTALLED AT FLOOR LINES.D) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL JOINTS, DO NOT
CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT REQUIREMENTS OF ASTM C-1063. AS SUCH STUCCO CONTRACTOR HASOPTION OF ONLY CUTTING JOINTS REQUIRED TO COMPLY WITH ASTMC-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDAREAS.METAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERASTM
C-1063.CONTROL JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THEFOLLOWING REQUIREMENTS:
2.3.
1.
3
44'-5 5/8"TRUSS.BRG42'-6 3/4"TRUSS.BRG33'-5 5/8"T.O. PLYWD.31'-8 7/8"TRUSS.BRG22'-7 3/4"T.O. PLYWD.20'-11"TRUSS.BRG11'-9 7/8"T.O. PLYWD.10'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
3
2
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMCONDITIONS.PROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER RODDOORS.
(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /
SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIORALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORALUMINUM.ALL ROOF TO WALL TERMINATIONS MUST HAVE SADDLE FLASHING AT
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR EDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.CLADDING
SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERINTRUSION.EXTERIOR WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELROOF PARAPET TERMINATION
8.
9.
10.11.12.13.14.
2
9
7
TYPICAL ELEVATION NOTES
8
6
" PER FOOT.
14
9
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDSTONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHERALL
EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED OF SEALANT.ALL BUILDING MOUNTED
EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTEROF MOUNTING AND WATERPROOFING TO ARCHITECT FOR APPROVAL. PLINTH
BARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE BARRIER.REFER TO KEYED NOTES.EXTERIOR FINISH IS APPLIED AND PAINTED.
IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR SHALL SUBMIT METHODBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYFROM UNIT FOR DRAINAGE AT ALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR ANDSLOPE AWAY FROM BUILDING.
2.3.4.
1.
5.7.
6.
4
8
6
ELEVATION KEY NOTES
STONE VENEER SYSTEMSTANDING SEAM METAL ROOFING
6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESANODIZED ALUMINUM FIBER CEMENT ACCESSORIESLIGHT FIXTUREALUMINUM GUARDRAILSPREFABRICATED
ALUMINUM AWNINGGLAZINGGUTTER SYSTEM
123456789
1011
1
5
6
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
FIVE
OCOEE, FLORIDA
NW
4406.21
08-11-2021
LAKE LILLY APARTMENTS
4406A2.54
BUILDING TYPE
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
44'-5 5/8"TRUSS.BRG42'-6 3/4"TRUSS.BRG33'-5 5/8"T.O. PLYWD.31'-8 7/8"TRUSS.BRG22'-7 3/4"T.O. PLYWD.20'-11"TRUSS.BRG11'-9 7/8"T.O. PLYWD.10'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
TYPICAL STUCCO NOTES
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".C) CONTROL JOINTS SHALL BE
INSTALLED AT FLOOR LINES.JOINTS, DO NOT CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT AESTHETIC JOINTS WHERE JOINTS SHOWN ON ELEVATION EXCEED THEOPTION OF ONLY CUTTING JOINTS REQUIRED
TO COMPLY WITH ASTMC-1063.
B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" IND) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL REQUIREMENTS OF ASTM C-1063. AS SUCH STUCCO CONTRACTOR HAS
AREAS.ASTM C-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDMETAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERCONTROL
JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THEFOLLOWING REQUIREMENTS:
2.3.
1.
1
5
3
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMCONDITIONS.PROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER RODDOORS.
(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /
SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIORALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORCLADDING SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERALUMINUM.ALL ROOF TO
WALL TERMINATIONS MUST HAVE SADDLE FLASHING AT
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR EDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.INTRUSION.E
XTERIOR WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELROOF PARAPET TERMINATION
8.9.
10.11.12.13.14.
2
7
TYPICAL ELEVATION NOTES
9
" PER FOOT.
14
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,STONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHER
CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDBARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE
BARRIER.REFER TO KEYED NOTES.ALL EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED
OF SEALANT.ALL BUILDING MOUNTED EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTEREXTERIOR FINISH IS APPLIED AND PAINTED. IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR
SHALL SUBMIT METHODOF MOUNTING AND WATERPROOFING TO ARCHITECT FOR APPROVAL. PLINTHBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
FROM UNIT FOR DRAINAGE AT
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR ANDSLOPE AWAY FROM BUILDING.
2.3.4.
1.
7.
5.6.
ELEVATION KEY NOTES
STONE VENEER SYSTEMANODIZED ALUMINUM FIBER CEMENT ACCESSORIESALUMINUM GUARDRAILSSTANDING SEAM METAL ROOFING
6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESLIGHT FIXTUREPREFABRICATED ALUMINUM AWNINGGLAZINGGUTTER SYSTEM
123456789
1011
7
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
OCOEE, FLORIDA
RMR
4406.21
BUILDING
CARRIAGE
08-11-2021
LAKE LILLY APARTMENTS
4406A2.61
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
31'-6 7/8"TRUSS.BRG22'-5 3/4"T.O. PLYWD.20'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
2
TYPICAL STUCCO NOTES
31'-6 7/8"TRUSS.BRG22'-5 3/4"T.O. PLYWD.20'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".C) CONTROL JOINTS SHALL BE
INSTALLED AT FLOOR LINES.JOINTS, DO NOT CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT AESTHETIC JOINTS WHERE JOINTS SHOWN ON ELEVATION EXCEED THEOPTION OF ONLY CUTTING JOINTS REQUIRED
TO COMPLY WITH ASTMC-1063.
B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" IND) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL REQUIREMENTS OF ASTM C-1063. AS SUCH STUCCO CONTRACTOR HAS
AREAS.ASTM C-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDMETAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERCONTROL
JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THEFOLLOWING REQUIREMENTS:
2.3.
1.
1
4
3
1
5
3
9
2
7
5
4
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMCONDITIONS.PROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER ROD(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /DOORS.
SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIORALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORCLADDING SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERALUMINUM.ALL ROOF TO
WALL TERMINATIONS MUST HAVE SADDLE FLASHING AT
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR EDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.INTRUSION.E
XTERIOR WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELROOF PARAPET TERMINATION
7
8.9.
10.11.12.13.14.
9
3
1
TYPICAL ELEVATION NOTES
" PER FOOT.
14
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,STONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHERALL EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST
BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED OF SEALANT.ALL BUILDING MOUNTED EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTER
CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDBARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE
BARRIER.REFER TO KEYED NOTES.EXTERIOR FINISH IS APPLIED AND PAINTED. IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR SHALL SUBMIT METHODOF MOUNTING AND WATERPROOFING
TO ARCHITECT FOR APPROVAL. PLINTHBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
FROM UNIT FOR DRAINAGE AT
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR ANDSLOPE AWAY FROM BUILDING.
2.3.4.
1.
7.
5.6.
31'-6 7/8"TRUSS.BRG22'-5 3/4"T.O. PLYWD.20'-11"TRUSS.BRG10'-9 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
3
ELEVATION KEY NOTES
STONE VENEER SYSTEMANODIZED ALUMINUM FIBER CEMENT ACCESSORIESALUMINUM GUARDRAILSGLAZINGSTANDING SEAM METAL ROOFINGGUTTER SYSTEM
6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESLIGHT FIXTUREPREFABRICATED ALUMINUM AWNING
9
123456789
1011
1
8
6
5
1
2
2
3
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
OCOEE, FLORIDA
RMR
4406.21
BUILDING
08-11-2021
LAKE LILLY APARTMENTS
TOWNHOME
4406A2.71
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
30'-0 7/8"TRUSS.BRG20'-11 3/4"T.O. PLYWD.19'-7"TRUSS.BRG10'-5 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB30'-0 7/8"TRUSS.BRG20'-11 3/4"T.O. PLYWD.19'-7"TRUSS.BRG10'-5 7/8"T.O. PLYWD.9'-1
1/8"TRUSS.BRG0'-0"T.O. SLAB
3
ELEVATION KEY NOTES
STONE VENEER SYSTEMANODIZED ALUMINUM FIBER CEMENT ACCESSORIESALUMINUM GUARDRAILSGLAZINGSTANDING SEAM METAL ROOFINGGUTTER SYSTEM
6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESLIGHT FIXTUREPREFABRICATED ALUMINUM AWNING
123456789
1011
1
TYPICAL STUCCO NOTES
5
AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" INC) CONTROL JOINTS SHALL BE INSTALLED AT FLOOR LINES.D) METAL LATH
SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL JOINTS, DO NOT CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT AESTHETIC JOINTS WHERE JOINTS SHOWN ON ELEVATION EXCEED THEREQUIREMENTS OF ASTM
C-1063. AS SUCH STUCCO CONTRACTOR HASOPTION OF ONLY CUTTING JOINTS REQUIRED TO COMPLY WITH ASTMC-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDAREAS.METAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERASTM
C-1063.CONTROL JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THE
FOLLOWING REQUIREMENTS:
2
2.
3.
1.
11
3
2
11
5
9
10
CONDITIONS.
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMPROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER ROD(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /DOORS.
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIOREDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE
SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.ALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORCLADDING SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERINTRUSION.EXTERIOR
WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELALUMINUM.ALL ROOF TO WALL TERMINATIONS MUST HAVE SADDLE FLASHING ATROOF PARAPET TERMINATION
8.9.
10.11.12.13.14.
1
7
8
TYPICAL ELEVATION NOTES
9
" PER FOOT.
6
1
4
8
6
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDSTONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHERALL
EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED OF SEALANT.ALL BUILDING MOUNTED
EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTEROF MOUNTING AND WATERPROOFING TO ARCHITECT FOR APPROVAL. PLINTH
BARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE BARRIER.REFER TO KEYED NOTES.EXTERIOR FINISH IS APPLIED AND PAINTED.
IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR SHALL SUBMIT METHODBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYFROM UNIT FOR DRAINAGE AT ALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
SLOPE AWAY FROM BUILDING.
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR AND
2.3.4.
1.
7.
5.6.
7
30'-0 7/8"TRUSS.BRG20'-11 3/4"T.O. PLYWD.19'-7"TRUSS.BRG10'-5 7/8"T.O. PLYWD.9'-1 1/8"TRUSS.BRG0'-0"T.O. SLAB
9
8
7
6
2
3
5
3 21
3
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
CBA
OCOEE, FLORIDA
RMR
4406.21
08-11-2021
CLUBHOUSE
LAKE LILLY APARTMENTS
4406A2.81
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
TYPICAL STUCCO NOTES
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE AREAS NOT MORE THAN 144 SQ. FT.B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" IN EITHER DIRECTION OR A LENGTH
TO WIDTH RATIO OF 2-1/2" TO 1".C) CONTROL JOINTS SHALL BE INSTALLED AT FLOOR LINES.D) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL JOINTS, DO NOT CUT PAPER. LATH IS NOT REQUIRED
TO BE CUT AT AESTHETIC JOINTS WHERE JOINTS SHOWN ON ELEVATION EXCEED THEREQUIREMENTS OF ASTM C-1063. AS SUCH STUCCO CONTRACTOR HASOPTION OF ONLY CUTTING JOINTS REQUIRED TO COMPLY WITH
ASTMC-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDAREAS.METAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERASTM
C-1063.CONTROL JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THEFOLLOWING REQUIREMENTS:
2.3.
1.
20'-0"TRUSS BRG.16'-0"WIN.HD.HT.12'-0"TRUSS BRG.8'-0"WIN.HD.HT.20'-0"TRUSS BRG.16'-0"WIN.HD.HT.12'-0"TRUSS BRG.20'-0"TRUSS BRG.16'-0"WIN.HD.HT.12'-0"TRUSS BRG.8'-0"WIN.HD.HT.20'-0"TRUSS
BRG.16'-0"WIN.HD.HT.12'-0"TRUSS BRG.8'-0"WIN.HD.HT.
18'-0"WIN.HD.HT.14'-0"WIN.HD.HT.10'-0"WIN.HD.HT.0'-0"FIN.FLR.18'-0"WIN.HD.HT.14'-0"TRUSS BRG.10'-0"WIN.HD.HT.0'-0"FIN.FLR.18'-0"WIN.HD.HT.14'-0"TRUSS BRG.10'-0"WIN.HD.HT.0'-0"FIN.FLR.18'-0"WIN.HD.HT.
14'-0"TRUSS BRG.10'-0"WIN.HD.HT.0'-0"FIN.FLR.
33
55
CONDITIONS.
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMPROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER ROD(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /DOORS.
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIOREDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE
SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.ALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORCLADDING SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERINTRUSION.EXTERIOR
WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELALUMINUM.ALL ROOF TO WALL TERMINATIONS MUST HAVE SADDLE FLASHING ATROOF PARAPET TERMINATION
8.
9.
10.11.12.13.14.
9
1
1
9
TYPICAL ELEVATION NOTES
2
8
" PER FOOT.
1 14
8
2
9
1
2
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,STONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHERALL EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST
BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED OF SEALANT.ALL BUILDING MOUNTED EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTER
CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDBARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE
BARRIER.REFER TO KEYED NOTES.EXTERIOR FINISH IS APPLIED AND PAINTED. IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR SHALL SUBMIT METHODOF MOUNTING AND WATERPROOFING
TO ARCHITECT FOR APPROVAL. PLINTHBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYFROM UNIT FOR DRAINAGE AT ALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR ANDSLOPE AWAY FROM BUILDING.
9
2.3.4.
1.
5.7.
4 6.
9
6
2
8
22
1
4
6
4
8
ELEVATION KEY NOTES
STONE VENEER SYSTEM6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESANODIZED ALUMINUM FIBER CEMENT ACCESSORIESLIGHT FIXTUREALUMINUM GUARDRAILSPREFABRICA
TED ALUMINUM AWNINGGLAZINGSTANDING SEAM METAL ROOFINGGUTTER SYSTEM
123456789
1011
3
3
4321
5
2
5
9
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
CBA
OCOEE, FLORIDA
NW
ANNEX
4406.21
BUILDING
08-11-2021
LAKE LILLY APARTMENTS
4406A2.91
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
10'-0"TRS BRG
10'-0"TRS BRG
16'-0"T.O. PARAPET13'-0"TO PARAPET8'-0"HD HGT0'-0"
16'-0"T.O. PARAPET13'-0"TO PARAPET8'-0"HD HGT0'-0"
10'-0"TRS BRG
10'-0"TRS BRG
3
8
16'-0"T.O. PARAPET13'-0"TO PARAPET8'-0"HD HGT0'-0"
16'-0"T.O. PARAPET13'-0"TO PARAPET8'-0"HD HGT0'-0"
TYPICAL STUCCO NOTES
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".C) CONTROL JOINTS SHALL BE
INSTALLED AT FLOOR LINES.JOINTS, DO NOT CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT AESTHETIC JOINTS WHERE JOINTS SHOWN ON ELEVATION EXCEED THEOPTION OF ONLY CUTTING JOINTS REQUIRED
TO COMPLY WITH ASTMC-1063.
B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" IND) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL REQUIREMENTS OF ASTM C-1063. AS SUCH STUCCO CONTRACTOR HAS
5
5
9
AREAS.ASTM C-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDMETAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERCONTROL
JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THEFOLLOWING REQUIREMENTS:
2.3.
1.
3
3
8
9
5
1
9
••••••••
6
••••••••
1
3
6
1
1
9
5
9
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMCONDITIONS.PROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER RODDOORS.
(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /
SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIORALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORCLADDING SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERALUMINUM.ALL ROOF TO
WALL TERMINATIONS MUST HAVE SADDLE FLASHING AT
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR EDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.INTRUSION.E
XTERIOR WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELROOF PARAPET TERMINATION
8.9.
9
10.11.12.13.14.
4321
TYPICAL ELEVATION NOTES
" PER FOOT.
14
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,STONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHER
CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDBARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE
BARRIER.REFER TO KEYED NOTES.ALL EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED
OF SEALANT.ALL BUILDING MOUNTED EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTEREXTERIOR FINISH IS APPLIED AND PAINTED. IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR
SHALL SUBMIT METHODOF MOUNTING AND WATERPROOFING TO ARCHITECT FOR APPROVAL. PLINTHBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
FROM UNIT FOR DRAINAGE AT
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR ANDSLOPE AWAY FROM BUILDING.
2.3.4.
1.
7.
5.6.
ELEVATION KEY NOTES
STONE VENEER SYSTEMANODIZED ALUMINUM FIBER CEMENT ACCESSORIESALUMINUM GUARDRAILSSTANDING SEAM METAL ROOFING
6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESLIGHT FIXTUREPREFABRICATED ALUMINUM AWNINGGLAZINGGUTTER SYSTEM
123456789
1011
charlan, brock & associates, inc. hereby reserves its common law copyright and other property rights in these plans, ideas, and designs. these ideas, designs, and plans are not to be
reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party, without first obtaining the express written permission from c.b.a., inc.
written dimensions shall have precedence over scale dimensions.
Charlan Brock & Associates, AAC000798
Charles L. Charlan, Architect, AR8219
PH. 407.345.9931
OCOEE, FL 32761
2940 MAGUIRE ROAD, SUITE 500
FORE PROPERTY COMPANY
planners
FL
••
-
CBA
OCOEE, FLORIDA
MV
4406.21
BUILDING
ANCILLARY 08-11-2021
LAKE LILLY APARTMENTS
4406A2.92
associates
architects
407 660 8900 f: 407 875 9948
maitland florida 32751-7208www . cbaarchitects . com
1770 fennell street
date:job no:drawn by:reviewed by:file:issue history:
CITY OF OCCOEE, FLORIDA
EXTERIOR ELEVATIONS
FSP Submittal 08-11-2021
13'-3 1/8"TO PARAPET9'-1 1/8"TRS BRG0'-0"
13'-3 1/8"TO PARAPET9'-1 1/8"TRS BRG0'-0"
13'-3 1/8"TO PARAPET9'-1 1/8"TRS BRG6'-8"HD HGT0'-0"
TYPICAL STUCCO NOTES
A) CONTROL JOINTS TO BE INSTALLED IN WALLS TO DELINEATE AREAS NOT MORE THAN 144 SQ. FT. EITHER DIRECTION OR A LENGTH TO WIDTH RATIO OF 2-1/2" TO 1".C) CONTROL JOINTS SHALL BE
INSTALLED AT FLOOR LINES.JOINTS, DO NOT CUT PAPER. LATH IS NOT REQUIRED TO BE CUT AT AESTHETIC JOINTS WHERE JOINTS SHOWN ON ELEVATION EXCEED THEOPTION OF ONLY CUTTING JOINTS REQUIRED
TO COMPLY WITH ASTMC-1063.
B) DISTANCE BETWEEN CONTROL JOINTS SHALL NOT EXCEED 18'-0" IND) METAL LATH SHALL BE DIS-CONTINUOUS (CUT) AT CONTROL REQUIREMENTS OF ASTM C-1063. AS SUCH STUCCO CONTRACTOR HAS
5
AREAS.ASTM C-1063.
WEEP SCREED SHALL BE APPLIED AT FOUNDATION. PLACE LINE AT AMIN. OF 4" ABOVE FINISHED GRADE AND MIN. OF 2" ABOVE PAVEDMETAL LATH TO BE INSTALLED OVER 60 MINUTE BUILDING PAPER PERCONTROL
JOINTS TO BE INSTALLED PER ASTM C-1063 INCLUDING THEFOLLOWING REQUIREMENTS:
2.3.
1.
2
6
321
PROVIDE URETHANE SEALANT AT ALL SIDING, PANEL AND TRIMCONDITIONS.PROVIDE URETHANE SEALANT W/ BOND BREAKER OR BACKER RODDOORS.
(TO PREVENT 3-SIDED ADHESION) AT PERIMETER OF WINDOWS /
SUBSTRATES, SUCH AS BALCONY CEILINGS, BALCONY EXTERIORALL ATTACHMENT AND PENETRATION THROUGH THE EXTERIORCLADDING SYSTEM MUST BE SEALED AGAINST POTENTIAL WATERALUMINUM.ALL ROOF TO
WALL TERMINATIONS MUST HAVE SADDLE FLASHING AT
PROVIDE SEALANT JOINTS AT INTERFACE BETWEEN DISSIMILAR EDGES, EXTERIOR WALL TO SOFFIT AND CEILING CONDITIONS ECT.PROVIDE POSITIVE SLOPE 1:2 AT TOP OF METAL FLASHINGS AT TRIMBANDS, TYPICAL.INTRUSION.E
XTERIOR WALLS TO BE PAINTED PRIOR TO INSTALLATION OFDOWNSPOUTS. ALL DOWNSPOUTS TO BE 6" ROUND BAKED ENAMELROOF PARAPET TERMINATION
9'-4"0'-0"
8.9.
10.11.12.13.14.
9'-4"0'-0"
9'-4"0'-0"
9'-4"0'-0"
1
2
TYPICAL ELEVATION NOTES
" PER FOOT.
14
TYPICAL EXTERIOR CLADDING - CEMENTITIOUS LAPPED SIDING,STONE VENEER OVER STRUCTURAL SHEATHING WITH FLUID APPLIED WEATHER
CEMENTITIOUS PANEL, PANELIZED FIBER CEMENT SYSTEM AND CULTUREDBARRIER. STONE VENEER TO BE INSTALLED OVER STUCCO BASE WITH METALLATH ON DRAIN MAT ON SECOND LATER OF WEATHER RESISTIVE
BARRIER.REFER TO KEYED NOTES.ALL EXTERIOR WOOD TRIM TO BE 5/4" HARDI TRIMALL PENETRATIONS MUST BE PROPERLY FLASHED AND/OR SEALED.ATTACHMENTS THROUGH EXTERIOR SKIN SHALL BE SET IN BED
OF SEALANT.ALL BUILDING MOUNTED EQUIPMENT, PANELS, ETC. SHALL BE MOUNTED AFTEREXTERIOR FINISH IS APPLIED AND PAINTED. IF SEQUENCING OF CONSTRUCTIONREQUIRES MOUNTING PRIOR TO THIS, CONTRACTOR
SHALL SUBMIT METHODOF MOUNTING AND WATERPROOFING TO ARCHITECT FOR APPROVAL. PLINTHBLOCKING REQUIRED AT ALL PENETRATIONS AND SURFACE MOUNTEDFIXTURES INCLUDING CULTURED STONE.
ALL UNIT BALCONIES TO HAVE STRUCTURAL FLOOR SYSTEM SLOPED AWAYALL EXTERIOR BALCONY RAILS TO BE PREFINISHED
FROM UNIT FOR DRAINAGE AT
ALL FINISH GRADE SHALL BE MINIMUM 8" BELOW FINISH FLOOR ANDSLOPE AWAY FROM BUILDING.
2.3.4.
1.
7.
5.6.
7654
ELEVATION KEY NOTES
STONE VENEER SYSTEMANODIZED ALUMINUM FIBER CEMENT ACCESSORIESALUMINUM GUARDRAILSSTANDING SEAM METAL ROOFING
6" REVEAL FIBER CEMENT LAP SIDINGFIBER CEMENT PANELSPANELIZED FIBER CEMENT SYSTEM - WOOD SERIESLIGHT FIXTUREPREFABRICATED ALUMINUM AWNINGGLAZINGGUTTER SYSTEM
123456789
1011