Loading...
HomeMy WebLinkAboutItem 25 Approval of 429 Business Center Phase II West Large Scale Final Site Plan and Development AgreementMeeting Date: December 5, 2023 Item #: 25 Contact Name: Anoch Whitfield Department Director: Michael Rumer Contact Number: Ext. 1016 City Manager: Robert Frank Background Summary: The property is located on the west side of the canal and east side of Pine Street, beginning approximately 462 feet north of Palm Drive. It is within Commission District 3, the SR 429 Overlay District Business Center Character Area and the Wekiva Study Area. The property contains three (3) parcels, totaling approximately 5.58 acres, which were approved for a Small -Scale Comprehensive Plan Future Land Use Map Amendment to Light Industrial and associated Rezoning to 1-1 on May 17, 2022. The table below lists the future land use designations, zoning classifications, and existing land uses of the surrounding parcels, Direction Future Land Use Zoning Classification Existing Land Use North Low Density Residential R-1A Residential South Low Density Residential & High Density Residential R-1A & County A-2 Residential East Conservation & Light Industrial 1-1 Vacant West Low Density Residential A-2 & R-1 A Residential On September 20, 2022, the City approved the Large -Scale Preliminary Site Plan for the 429 Business Center Phase II - West Development, which consists of a 70,720 SF light industrial and flex warehouse development contained in a single building. This 429 Business Center Phase II - West Development is part of a larger development, which includes 429 Business Center Phase II East, located on the east side of the canal and west side of Ocoee Apopka Road. In terms of traffic and access, the site plan shows two (2) driveway access points off of Pine Street. However, per the conditions of approval for the Small Scale Comprehensive Plan Future Land Use Map Amendment and Rezoning, industrial and commercial traffic and vehicles will not be allowed to utilize Pine Street until such time that Pine Street is designed and improved to support non-residential traffic. Mechanisms will be required to be put in place to limit or avoid cut -through traffic once Pine Street is improved. Instead, the development of this site will be dependent upon and utilize the future east -west road located along the north property City of • •-- - 1 N. Bluford ' • re_ Florida 34761 • - (4 ' i1 • i-- • t Page 537 of 593 boundary and extending to Ocoee Apopka Road. This new roadway will be designed and constructed to City standards and will be dedicated to the City. It is consistent with the transportation vision for the Business Character District and will connect this project to the Phase 11 East project. Stormwater will be provided on -site at the rear of the property adjacent to the canal, and water and sewer utility services will be provided by the City. Approval of this final site plan is in conjunction with a Development Agreement. Issue: Should the City Commission approve the Large -Scale Final Site Plan for the 429 Business Center Phase 11 West Development located at 701, 707, and 711 Pine Street, assigned parcel ID numbers 18-22-28-0000-00- 005, 18-22-28-0000-00-106 and 18-22-28-0000-00-105? Recommendations: Staff recommends that the City Commission approve the Large -Scale Final Site Plan for the 429 Business Center Phase 11 West Development located at 701, 707, and 711 Pine Street, assigned parcel ID numbers 18-22-28-0000- 00-005, 18-22-28-0000-00-106 and 18-22-28-0000-00-105. Attachments: 1. Location Map 2. Aerial 429 Center West 3. West Zoning Map 4. Civil Plans 5. Landscape Plans 6. Building Elevations 7. 429 Business Center Ph 11 West DevAgreement(1537881492.4) Financial Impacts: None Type of Item: Consent City of Ocoee - 1 N. Bluford Avenue - Ocoee, Florida 34761 Phone: (407) 905-3100 - www.ocoee.org Page 538 of 593 429 Business Center Phase II East & West Cn 0 Location Map West ■ East Page 539 of 593 Page 540 of 593 429 Business Center Phase II West Surrounding Zoning Map Development Services Department 0 90 180 360 Feet Created: September 2022 MSubject P roperty Zoning Classification: General Agricultural (A-1) Suburban (A-2) Single -Family Dwelling (R-1AAA) Single -Family Dwelling (R-1AA) Single -Family Dwelling (R-1A) Single -Family Dwelling (R-1) One- & Two -Family Dwelling (R-2) No Multiple -Family Dwelling (R-3) Mobile Home Subdivision (RT-1) Professional Offices & Services (P-S) Neighborhood Shopping (C-1 ) Community Commercial (C-2) ININGeneral Commercial (C-3) Restricted Manufacturing "& Warehousing (1-1) General Industrial (I-2) Commercial (PUD) Low Density (PUD) Medium Density (PUD) High Density (PUD) Public Use (PUD) VAV Unclassified Page 541 of 593 DEVELOPER: TSG DEVELOPMENT, INC. MR. J. WILSON McDOWELL 250 S. ORANGE AVENUE SUITE 700 ORLANDO, FL 32801 TEL: 407-930-1801 E—MAIL: WILSON.MCDOWELLOJLL.COM SURVEYOR: BENCHMARK SURVEYING & MAPPING, INC. 3110 RED FOX RUN KISSIMMEE, FL 34746 TEL: 407.654.6183 ATTN: BILLY JOE JENKINS, JR. P.S.M. EMAIL: JOEOBENCHMARKSURVEYINGANDMAPPING.COM ARCHITECT: C4 ARCHITECTURE CLARK STRANAHAN 135 W CENTRAL BLVD, SUITE 340 ORLANDO, FL 32801 TEL: 407-221-7864 E—MAIL: CSTRANAHANOC4ARCHITECTURE.COM ENGINEER: KLIMA WEEKS CIVIL ENGINEERING, INC. SELBY G. WEEKS, P.E., LEED AP 385 DOUGLAS AVE., STE. 2100 ALTAMONTE SPRINGS, FL 32714 TEL: 407.478.8750 FAX: 407.478.8749 E—MAIL: SWEEKS@KLIMAWEEKS.COM LANDSCAPE ARCHITECT: BONNET DESIGN GROUP, LLC TODD W. BONNET, RLA 400 S. ORLANDO AVENUE, SUITE 201 MAITLAND, FL 32751 TEL: 407-622-1588 E—MAIL: TODD@BONNETTDESIGNGROUP.COM I 4) GEOTECHNICAL ENGINEER: ARDAMAN & ASSOCIATES, INC. 8008 S. ORANGE AVENUE ORLANDO, FL 32809 TEL: 407-855-3860 FAX: 407-859-8121 ATTN: CHUCK CUNNINGHAM, P.E. E—MAIL: CCUNNINGHAM®ARDAMAN.COM TRAFFIC ENGINEER: TRAFFIC PLANNING AND DESIGN, INC. TURGUT DERVISH, P.E., PRESIDENT 535 VERSAILLES DRIVE MAITLAND, FL. 32751 TEL: 407-628-9955 E—MAIL: TURGUT®TPDTRAFFIC.COM Li WATER/SEWER RECLAIM: z CITY OF OCOEE 1800 A. D. MIMS ROAD OCOEE, FL 34761 TEL: 407-905-3159 FAX: 407-877-5899 ATTN: JAMIE CROTEAU UTILITIES DIRECTOR FIRE & RESCUE DEPARTMENT: CITY OF OCOEE 563 S. BLUFORD AVE. OCOEE, FL 34761 TEL: 407-905-3140 FAX: 407-905-3129 ATTN: JOHN MILLER FIRE CHIEF CITY OF OCOEE 0 PLANNING ZONING AND DEVELOPMENT DEPT. 1 N. BLUFORD AVENUE OCOEE, FL 34761 TEL: 407-905-3157 FAX: 407-905-3158 ATTN: MICHAEL RUMER DEVELOPMENT SERVICES DIRECTOR ST. JOHN'S RIVER WATER MANAGEMENT DISTRICT 601 S. LAKE DESTINY ROAD, SUITE 200 MAITLAND, FL 32751 TEL: 407-659-4800 LARGE SCALE FINAL SITE PLAN AUGUST 2023 18-22-28-0000-oo-105 18-22-28-0000-oo-ioI6 r-8-22-28-000O-00-005 SHEET INDEX: C000 COVER SHEET Si BOUNDARY & TOPOGRAPHIC SURVEY C100 SITE PLAN C200 EROSION CONTROL & DEMOLITION PLAN C300 GEOMETRY, STRIPING & SIGNAGE PLAN C400 GRADING & DRAINAGE PLAN 0 C500 UTILITY PLAN C501 UTILITY PLAN AND PROFILE 0 C502 MASTER UTILITY PLAN C600 SITE DETAILS C6o1 EROSION CONTROL & DEMOLITION DETAILS C700 DRAINAGE DETAILS 0 C800 WATER & SANITARY DETAILS C801 WATER & SANITARY DETAILS C802 WATER & SANITARY DETAILS C803 LIFT STATION DETAILS Pe 701, 707, 711 PINE STREET OCOEE, FL 34761 D[UNIN wilm0 w m • a W9 NORTH 1 /2 OF SOUTHWEST 1 /4 OF NORTHEAST 1 /4 OF NORTHWEST 1 /4 AND SOUTH 1 /2 OF NORTHWEST 1 /4 OF NORTHEAST 1 /4 OF NORTHWEST 1 /4 OF SECTION 18-22-28, ORANGE COUNTY, FLORIDA (LESS WEST 448 FEET OF SOUTH 100 FEET OF NORTH 1 /2 OF SOUTHWEST 1 /4 OF NORTHEAST 1 /4 OF NORTHWEST 1 /4 OF SECTION 18-22-28, AND LESS THE LAND LYING EAST OF CENTER LINE OF THE DITCH SURVEY LINE DESCRIBED AS FOLLOWS: COMMENCE ON EAST LINE OF NORTHWEST 1 /4 OF SECTION AT A POINT 343.60 FEET NORTH OF THE SOUTHEAST CORNER THEREOF AND RUN SOUTH 89002'48" WEST 55.17 FEET; THENCE RUN NORTH 51 °44'12" WEST 996.47 FEET; THENCE RUN NORTH 0°57'42" WEST 298.7 FEET; THENCE RUN NORTH 0°30'18" EAST 290.02 FEET; THENCE RUN NORTH 0046'42" WEST 255.38 FEET; THENCE RUN NORTH 07°33'18" EAST 318.92 FEET; THENCE RUN NORTH 04°59"18" EAST 149.98 FEET; THENCE RUN NORTH 13°21'18" EAST 152.42 FEET; THENCE RUN NORTH 02°18'42" WEST 150.80 FEET TO THE NORTH LINE OF SAID SECTION 18.) ALSO LESS THE SOUTH 2O.00 FEET OF THE WEST 449.00 FEET OF THE ABOVE DESCRIBED PARCEL. ALSO LESS THAT PORTION CONVEYED TO THE CITY OF OCOEE BY SPECIAL WARRANTY DEED RECORDED IN INSTRUMENT NUMBER #20200486135, PUBLIC RECORDS OF ORANGE COUNTY, FLORIDA. mein me �: o ZONING: 1-1 L101 LANDSCAPE PLAN EXISTING USE: SINGLE FAMILY RESIDENCES L102 LANDSCAPE NOTES & DETAILS PROPOSED USE: WAREHOUSE 1 L201 IRRIGATION PLAN FUTURE LAND USE: (LI) LIGHT INDUSTRIAL L202 IRRIGATION NOTES AND DETAILS A103 ARCHITECTURAL SITE PLAN AND DUMPSTER DETAILS A4o1 BUILDING boo ELEVATIONS CHARACTER AND INTENDED USE: E201 SITE LIGHTING PHOTOMETRICS THE PROPOSED CONSTRUCTION CONSISTS OF A 71,008 SF SINGLE STORY WAREHOUSE BUILDING, PARKING LOT, E202 PHOTOMETRIC CUTSHEETS ASSOCIATED WATER, SEWER AND STORMWATER. E203 PHOTOMETRIC CUTSHEETS E204 PHOTOMETRIC CUTSHEETS FLOOD ZONE: VICINITY & EXISTING ZONING MAP N.T.S. 701, 707, 711 PINE STREET, OCOEE SUBJECT PROPERTY LIES WITHIN ZONE X, AN AREA DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN, AND ZONE AE, AND AREA WHERE BASE FLOOD ELEVATIONS ARE DETERMINED (114') ACCORDING TO THE NATIONAL FLOOD INSURANCE PROGRAM, FLOOD INSURANCE RATE MAP NUMBER 12095CO210H, DATED SEPTEMBER 24, 2021. NO. REVISION BY DATE 1 AGENCY COMMENTS JD / DB 03.20.23 2 SJRWMD PAC JD / DB 04.21.23 CITY COMMENTS JD / DB o6.26.23 CITY COMMENTS JD / DB 07.27.23 LA - Filename : C000—00VR—WEST-21TSGD001.dwg Plot Date : Aug. 01, 2023 9:46am Page 542 of 593 W z LEGEND: LIGHT -DUTY ASPHALT PAVEMENT (REFER TO DETAIL, SHEET C600) 4" CONCRETE WALK (REFER TO DETAIL, SHEET C600) 0 6" CONCRETE WALK (REFER TO DETAIL, SHEET C600) CONCRETE PAVEMENT (REFER TO DETAIL, SHEET C600) HEAVY DUTY ASPHALT PAVEMENT (REFER TO DETAIL, SHEET C600) CONCRETE DUMPSTER PAD PAVEMENT (REFER TO DETAIL, SHEET C600) GRAPHIC SCALE 30 0 15 30 60 GENERAL NOTES IN FEET ) } " 1, CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANIES PRIOR TO ANY CONSTRUCTION ACTIVITY FOR DIG PERMITS, ELECTRICAL PERMITS OR OTHER PERMITS I AS APPLICABLE. CONTRACTOR IS ALSO TO COORDINATE FULLY WITH UTILITY COMPANIES ON EXACT LOCATION OF UNDERGROUND UTILITIES AND ANY UTILITY (............ N ADJUSTMENT REQUIRED. UTILITY COMPANIES SHALL BE NOTIFIED A MINIMUM OF THREE WORKING DAYS PRIOR TO EXCAVATION. I 2. THE LOCATION OF EXISTING UTILITIES SHOWN ON THESE PLANS WERE DEPICTED FROM ACTUAL FIELD MEASUREMENTS AND/OR DERIVED FROM RECORD DRAWINGS. IT IS THE CONTRACTORS RESPONSIBILITY TO CONFIRM THE LOCATION OF EXISTING UTILITIES TO DETERMINE IF THERE ARE ANY CONFLICTS WITH THE PROPOSED CONSTRUCTION AND TO COORDINATE WITH THE UTILITY OWNERS TO RESOLVE THESE CONFLICTS. 3. THE SUBSURFACE INFORMATION FOR THIS PROJECT WAS OBTAINED FOR DESIGN PURPOSES AND MAY NOT BE AN ADEQUATE REPRESENTATION OF ACTUAL CONDITIONS FOR PROJECT CONSTRUCTION. INFORMATION SHOWN, INCLUDING WATER LEVELS, REPRESENTS EXISTING CONDITIONS AT THE SPECIFIC BORING 1O LOCATIONS AT THE TIME THE BORINGS WERE MADE. Q PROPOSED 4. ANY DIFFERING SITE CONDITIONS FROM THAT WHICH IS REPRESENTED HEREON, WHETHER ABOVE, ON OR BELOW THE SURFACE OF THE GROUND, SHALL BE POND BROUGHT TO THE IMMEDIATE ATTENTION OF THE ENGINEER, IN WRITING, WITHIN 48 HOURS OF DISCOVERY. NO CLAIM FOR EXPENSES INCURRED BY THE - CONTRACTOR DUE TO SUCH DIFFERING CONDITIONS WILL BE ALLOWED IF HE OR SHE FAILS TO PROVIDE THE WRITTEN NOTIFICATION. o 5. ALL MATERIALS, INSTALLATION AND TESTING SHALL BE IN ACCORDANCE WITH THE CITY OF OCOEE AND FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD ..........� SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. WHERE THE SPECIFICATIONS CONFLICT THE MORE STRINGENT SPECIFICATION SHALL I APPLY, AS 20.00. DETERMINED BY THE ENGINEER -OF -RECORD OR THE CITY ENGINEER. I FEMA FLOODPLAIN LINE I 6. THE CONTRACTOR SHALL PROVIDE ALL SHEETING, SNORING AND BRACING REQUIRED TO PROTECT ADJACENT STRUCTURES AND UTILITIES OR MINIMIZE TRENCH WIDTH AS REQUIRED. SHEETING AND SHORING SHALL BE DESIGNED BY A STATE OF FLORIDA PROFESSIONAL ENGINEER RETAINED BY THE CONTRACTOR. 7. THE CONTRACTOR SHALL ENSURE THAT ALL REQUIRED CONSTRUCTION PERMITS HAVE BEEN OBTAINED PRIOR TO COMMENCING WORK. 8. ALL DEBRIS AND WASTE MATERIALS GENERATED BY DEMOLITION OR SUBSEQUENT CONSTRUCTION ACTIVITIES SHALL BE DISPOSED ED OFF -SITE IN A LEGAL ' I MANNER AT AN APPROVED DISPOSAL FACILITY. THE CONTRACTOR SHALL OBTAIN ANY AND ALL PERMITS REQUIRED FOR DEMOLITION, CONSTRUCTION WORK AND HAULING WASTE MATERIAL. ALL ASSOCIATED COSTS AND PERMIT FEES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. .. a i - " 1 0.00 2 ACCESSIBLE __-_- 2 -- 9. ANY PUBLIC LAND CORNER, WITHIN THE LIMITS OF CONSTRUCTION, IS TO BE PROTECTED. IF A CORNER MONUMENT IS IN DANGER OF BEING ALTERED AND 1 N -N- PARKING SPACES AND HAS NOT YET BEEN PROPERLY REFERENCED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER WITHOUT DELAY. 5' ACCESS AISLE 10. COORDINATE VALUES ARE BASED ON A LOCAL GRID ESTABLISHED BY THE SURVEY. a 11. ALL REFERENCES TO PROPOSED CONSTRUCTION INDICATES CONSTRUCTION INCLUDED IN THIS CONTRACT. BUILDING 600 12. ALL PIPING TO HAVE A MINIMUM OF THREE (3) FEET COVER UNLESS OTHERWISE NOTED ON PLANS. 2...00 _ I � 13. THE CONTRACTOR SHALL FURNISH, ERECT AND MAINTAIN ALL NECESSARY STRIPING, TRAFFIC CONTROL AND SAFETY DEVICES IN ACCORDANCE WITH THE u 71,008 SF m CD MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, LATEST EDITION, AND THE LATEST FLORIDA DEPARTMENT OF TRANSPORTATION FY 2021-22 STANDARD � X z PLANS. m - - l _ I ........ �" "�, u, I � 14. MAINTENANCE OF TRAFFIC. ACCESS FOR LOCAL TRAFFIC SHALL BE MAINTAINED. IF, DURING CONSTRUCTION, ACCESS FOR LOCAL TRAFFIC IS CHANGED, THE N DUMPSTER ENCLOSURE m �, 10.......... , o - CONTRACTOR SHALL NOTIFY THE APPROPRIATE JURISDICTIONAL AGENCY A MINIMUM OF THREE (3) WORKING DAYS IN ADVANCE. MAINTENANCE OF TRAFFIC ®„ (REFER TO ARCHITECTURAL ® SHALL BE IN ACCORDANCE WITH INDEX NO. 102 OF THE FLORIDA DEPARTMENT OF TRANSPORTATION FY 2022-23 STANDARD PLANS. Q „ . PLANS FOR DETAILS 15. REFER TO FDOT ROADWAY AND TRAFFIC DESIGN STANDARDS FOR THE FOLLOWING: . b (2) ACCESSIBLE ) (FY 2022-23 ) 'PARKING SPACES AND � '-� I A. TYPE >,C„ INLET (INDEX No. 425-052) W B. TYPE V INLET INDEX No. 425-041 �.. 5 ACCESS AISLE � �; ( ) �-+ C. MITERED END SECTION (INDEX No. 430-021) D. CONCRETE BOX CULVERT WINGWALLS AND HEADWALLS INDEX No. 400-289 400-291 400-292 N E. CURB RAMP (INDEX No, 522-002) ' F. CURB TRANSITION (INDEX No. 520-001) CD W G. CONCRETE BUMPER GUARD (WHEEL STOP) (INDEX No. 520-001) .. H. CROSSWALK, STOP BAR (INDEX No. 711-001) AERIAL FIRE TRUCK MODEL ... � ,.---- � -- � I � I. PAVEMENT ARROWS (INDEX No. 711-001) W I z. J. STRUCTURE BOTTOMS TYPE "J" AND "P" (INDEX No. 425-010) =D , " K. SUPPLEMENTARY DETAILS FOR MANHOLES AND INLETS (INDEX No. 425-001) a . .. L. CONCRETE SIDEWALK (INDEX No. 522-001) . - - - M. TYPE "D" CURB (INDEX No. 520-001) >-4. D N. O. TYPE „F„ B & GUTTER (INDEX No. 520-001) „ r, VALLEY GUTTER (INDEX No 520-001) (ALL NUMBERS REFERENCED ARE PER FDOT STANDARD PLAN INDEX) 4.4I �� �. ( 16. AS -BUILT DRAWINGS, SIGNED AND SEALED BY A LAND SURVEYOR REGISTERED IN THE STATE OF FLORIDA, SHALL BE PROVIDED PER THE PROJECT o IO SPECIFICATIONS AND CITY OF OCOEE REQUIREMENTS, AND SHALL BE SUBMITTED TO THE CITY IN ACCORDANCE WITH SECTION 3.01.05 OF THE ENGINEERING P DRAINAGE T STANDARDS MANUAL IN THE FOLLOWING FORMATS: H _ EASE'MEN� IL N- ; O.R. 901, PG. 209 A. 1 PDF COPY ...... B. CAD COPY DRAWN IN STATE PLANE COORDINATES 6..... AS -BUILT DRAWINGS MUST ALSO COMPLY WITH FDOT AND SJRWMD REQUIREMENTS. � O I 7. ALL SIGNAGE FOR THE PROJECT HALL COMPLY WITH THE ADOPTED CITY OF OCOEE IGNAGE REGULATIONS. ,E.......... � \ J�,J 1 C S C C S I 18. THE MOST STRINGENT STANDARDS BETWEEN THE CITY STANDARDS AND THE STANDARDS ET FORTH IN THESE GENERAL NOTES SHOULD B FOLLOWED. I a \ S S E C S S S E ll.l...... �. f 19. ALL FINISHED FLOOR ELEVATIONS WILL EXCEED THE 100-YEAR FLOOD PLAIN BY A MINIMUM OF ONE FOOT (1'). 20. FINISHED FLOOR ELEVATION WILL EXCEED THE 100-YEAR FLOODPLAIN BY A MINIMUM OF TWO FEET (2'). Z�3\ FUTURE LAND USE REQUIRED: OFFICE: 1 SPACE PER 300 SF Po t INDUSTRIAL: 1 SPACE PER 1,000 SF* * CITY OF OCOEE DOES NOT HAVE A SPECIFIC PARKING STANDARD FOR NON -MANUFACTURING WAREHOUSE, TOTAL BUILDING AREA: 71,008 SF SOILS THEREFORE, [(1 SPACE/300 SF x 3,600 SF) + (1 SPACE/1,000 SF x 67,408 SF)] = 79 SPACES POMELLO FINE SAND REQUIRED PARKING: 79 SPACES SMYRNA-SMYRNA, WET. FINE SAND WABASSO FINE SAND PROVIDED PARKING: PROPOSED REGULAR PARKING SPACES: 71 PROPOSED ACCESSIBLE PARKING SPACES: 4 TOTAL PROPOSED PARKING SPACES: 75* .� PROPERTY INFORMATION: PARCEL IDs: 18-22-28-0000-00-105 18-22-28-0000-00-106 18-22-28-0000-00-005 ADDRESS: 701, 707, 711 PINE STREET, OCOEE, FL 34761 EXISTING USE: SINGLE FAMILY RESIDENCES PROPOSED USE: WAREHOUSE CHARACTER AND INTENDED USE THE PROPOSED CONSTRUCTION CONSISTS OF A 71,008 SF SINGLE STORY WAREHOUSE BUILDING, PARKING LOT, ASSOCIATED WATER, SEWER AND STORMWATER. BUILDING SETBACKS VAR®(IDENTIFICATION) FRONT (WEST) - SIDE (NORTH) - SIDE (SOUTH) - REAR (EAST) - LANDSCAPE BUFFERS YARN (IDENTIFICATION FRONT (EAST) SIDE (NORTH) SIDE (SOUTH) REAR (WEST) BUILDING SETBACKS REQUIRED PROVIDED 35' 86' 15, 15, 20' 46' 10' 19 6' LANDSCAPE BUFFERS REQUIRED PROVIDED 15' 15' 10' 15' 8' 1 1 ' 0' 7 3' • TOTAL PROJECT AREA: 256,932 5.90 100.0 EXISTING IMPERVIOUS: 7,618 OA 7 3.0 EXISTING OPEN SPACE: 249,314 5.72 97.0 PROPOSED IMPERVIOUS: 178,840 4A 1 69.6 0 PROPOSED OPEN SPACE: 78,092 1.79 30.4 2 PROPOSED ISR = 0.70 MAXIMUM IMPERVIOUS SURFACE PERMITTED: 70% 1 PROPOSED IMPERVIOUS SURFACE PERCENTAGE IS BASED ON THE SITE AREA PRIOR TO RIGHT-OF-WAY DEDICATIONS. 2 6,823 SF (0.16 AC) OF PERVIOUS AREA IS WITHIN THE FUTURE RIGHT-OF-WAY. BUILDING INFORMATION PROPOSED BUILDING: WAREHOUSE, 71,008 SF FBC CONSTRUCTION TYPE: II-B MAX PERMITTED BUILDING HEIGHT: INDUSTRIAL: TWO-STORY PROPOSED BLDG. HEIGHT: ONE-STORY, 45'-0" MAXIMUM BUILDING COVERAGE PERMITTED: 30% BUILDING COVERAGE: 28%* *PROPOSED BUILDING COVERAGE IS BASED ON THE SITE AREA PRIOR TO RIGHT-OF-WAY DEDICATIONS. FEMA FLOOD DATA SUBJECT PROPERTY LIES WITHIN ZONE X, AN AREA DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN, AND ZONE AE, AN AREA WHERE BASE FLOOD ELEVATIONS ARE DETERMINED (114') ACCORDING TO THE NATIONAL FLOOD INSURANCE PROGRAM, FLOOD INSURANCE RATE MAP NUMBER 12095CO210H, DATED SEPTEMBER 24, 2021. Cnz ac UA z U z 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Selby G. Weeks 56991 9 as 9 revision description date Al 0 0 0 0 AGENCY COMMENTS o3.> 6.23 SJRWMD PAC o4.2i.23 CITY COMMENTS o6.26.23 CITY COMMENTS O ].2 ].23 drawn by: JD checked by: SGW date: 08/05/2022 plot scale: AS SHOWN project number: N/A file name:C100-SITE-WEST-21TSGDoo1.DWG * THIS SITE IS PROVIDING RIGHT-OF-WAY AND A CONNECTING SIDEWALK TO THE MULTI -USE TRAIL IN OCOEE-APOPKA RD, WHICH REDUCES THE NEED FOR PARKING; THEREFORE, THE PROPOSED PARKING COUNT IS ACCEPTABLE. Filename : C10D-SITE-WEST-21TSGD001.dwg Plot Date : Aug. 01, 2023 9:49am Page 543 of 593 DEMOLITION NOTES: 1. UTILITY LINES, CONDUITS, & STRUCTURES WITHIN EXISTING EASEMENTS SHALL BE LOCATED AND PROTECTED THROUGHOUT CONSTRUCTION UNLESS SPECIFICALLY NOTED FOR RELOCATION OR REMOVAL. 2. UTILITY LINES, CONDUITS, & STRUCTURES WITHIN NEW BUILDING AREA SHALL BE DEMOLISHED, REMOVED FROM SITE, AND DISPOSED IN AN APPROVED WASTE DISPOSAL AREA, 3 "BUILDING AREAS" SHALL BE CLEANED OF ALL EXISTING PAVEMENT, BUILDING SLABS, FOOTINGS, FOUNDATIONS, UTILITIES AND SEWERS. NO EXISTING IMPROVEMENTS SHALL BE LEFT UNDER PROPOSED BUILDING AREAS. 4. ALL AREAS WHERE PAVEMENT, BUILDING SLABS, FOUNDATIONS, UTILITIES, CONDUITS, AND/OR UTILITY STRUCTURES HAVE BEEN REMOVED SHALL BE BACK FILLED WITH SELECT BACK FILL MATERIAL. ALL SELECT BACK FILL MATERIAL SHALL BE PLACED AND COMPACTED PER THE REQUIREMENTS OF THE SPECIFICATIONS AND THE ON -SITE GEOTECHNICAL ENGINEER, 5. CONTRACTOR TO COORDINATE WITH UTILITY COMPANIES PRIOR TO ANY CONSTRUCTION ACTIVITY FOR DIG PERMITS, ELECTRICAL PERMITS OR OTHER PERMITS AS APPLICABLE. 6. CONTRACTOR IS TO COORDINATE FULLY WITH UTILITY COMPANIES ON EXACT LOCATION OF UNDERGROUND UTILITIES PRIOR TO EXCAVATION. ALL DEBRIS AND WASTE MATERIALS GENERATED BY DEMOLITION OR SUBSEQUENT CONSTRUCTION ACTIVITIES SHALL BE DISPOSED OFF -SITE IN A LEGAL MANNER AT AN APPROVED DISPOSAL FACILITY. 7. THE CONTRACTOR SHALL OBTAIN ANY AND ALL PERMITS REQUIRED FOR DEMOLITION, CONSTRUCTION WORK AND HAULING WASTE MATERIAL. ALL ASSOCIATED COSTS AND PERMIT FEES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR ASPHALT RESURFACING AND STRIPING TO ALL EXISTING ROADS WHICH ARE DAMAGED DURING CONSTRUCTION. ALL REPAIRS TO BE MADE IN ACCORDANCE WITH FDOT REQUIREMENTS. 9. ANY ENCOUNTERED CONTAMINATED MATERIALS SHALL BE DISPOSED OF IN A MANNER APPROVED BY THE ENGINEER IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REGULATIONS, PROVIDE TEMPORARY EROSION - r 10. THE CONTRACTOR IS ADVISED THAT UNCHARTED UTILITIES MAY BE FOUND TO EXIST WITHIN THE CONSTRUCTION AREA AND THAT CONSTRUCTION OPERATIONS SHOULD BE CONDUCTED WITH CAUTION, CONTROL MEASURES FOR DITCH 11. ALL CONCRETE TO BE REMOVED SHALL BE SAW CUT AT THE NEAREST JOINT IN REASONABLY GOOD CONDITION, SO AS TO PRODUCE A CONNECTION WITH NEW CONCRETE THAT IS FREE OF CRACKS, DEFORMITY IN SHAPE, SIDE SLOPES NOTICEABLE VOIDS, SURFACE IRREGULARITIES, AND OTHER DEFECTS. CONCRETE GUTTER SHALL BE SAW CUT BETWEEN ASPHALT AND GUTTER BEFORE REMOVAL. GABION BASKET AS TEMPORARY EROSION CONTROL MEASURE IN 1❑ DITCH BOTTOM. I 7 7% / / //'///� /�7n I I 2 1l 50' GRAVEL CONSTRUCTION ENTRANCE PER DETAIL, THIS SHEET. /j CONTRACTOR SHALL COORDINATE WITH POWER COMPANY TO REMOVE EXISTING POWER POLE AND ASSOCIATED LINES THAT SERVE EXISTING RESIDENCE TO BE DEMOLISHED, 1 PROPERTY LINE DEMOLITION LEGEND NOTE: REFER TO DEMOLITION NOTES, THIS SHEET, FOR ADDITIONAL DETAILS SILT FENCE (REFER TO DETAIL THIS SHEET) TREE PROTECTION BARRICADE (REFER TO TREE PROTECTION BARRIER DETAIL, SHEET C601) EXISTING TREE TO DIAMETER OF 36" BE REMOVED (NOTE THAT THIS SITE IS WOODED AND ONLY TREES WITH A OR GREATER ARE LOCATED ON THE SURVEY, ALL TREES WITHIN CLEARING LIMITS ARE TO BE REMOVED, WITH THE EXCEPTION OF THOSE SHOWN TO REMAIN.) LIMITS OF CLEARING AND GRUBBING REMOVE EXISTING BUILDINGS, STRUCTURES, FOUNDATIONS, AND CONCRETE. EXISTING UTILITIES TO REMAIN AND BE PROTECTED GRAPHIC SCALE 30 0 15 30 60 Q2 EXISTING WATER METER AND SERVICE LINE TO BE REMOVED. CONTRACTOR SHALL CONFIRM THAT WATER METERS TO BE REMOVED SERVE RESIDENCES TO BE DEMOLISHED AS PART OF THIS PROJECT PRIOR TO REMOVAL. CONTRACTOR SHALL DOCUMENT METER SIZE WITH CITY OF OCOEE FOR IMPACT FEE CREDIT. ( IN FEET ) EROSION CONTROL NOTES 1. ALL EROSION AND SEDIMENT CONTROL WORK SHALL CONFORM TO STANDARDS OF OCOEE, FLORIDA AND THE ST. JOHNS RIVER WATER MANAGEMENT DISTRICT, 2. EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO, OR AS THE FIRST STEP IN, CONSTRUCTION. SEDIMENT CONTROL PRACTICES WILL BE APPLIED AS A PERIMETER DEFENSE AGAINST ANY TRANSPORTATION OF SILT OFF THE SITE. 3. SOIL MATERIALS FROM WORK ON THIS PROJECT SHALL BE CONTAINED AND NOT ALLOWED TO COLLECT ON ANY OFF -PERIMETER AREAS OR IN WATERWAYS, THESE INCLUDE BOTH NATURAL AND MAN-MADE OPEN DITCHES, STREAMS, STORM DRAINS, LAKES AND PONDS, 4. DAILY INSPECTIONS SHALL BE MADE BY THE CONTRACTOR TO DETERMINE THE EFFECTIVENESS OF EROSION/SEDIMENT CONTROL EFFORTS. ANY NECESSARY REMEDIES SHALL BE PERFORMED WITHOUT DELAY. 5. ALL MUD, DIRT, OR OTHER MATERIALS TRACKED OR SPILLED ONTO EXISTING PUBLIC OR PRIVATE ROADS AND FACILITIES FROM THIS SITE, DUE TO CONSTRUCTION, SHALL BE PROMPTLY REMOVED BY THE CONTRACTOR. 6. ALL PERMANENT EROSION CONTROL MEASURES FOR ALL SLOPES, CHANNELS AND ANY DISTURBED LAND AREAS SHALL BE COMPLETED WITHIN 15 CALENDAR DAYS AFTER FINAL GRADING. 7. ALL TEMPORARY PROTECTION SHALL BE MAINTAINED UNTIL PERMANENT MEASURES ARE IN PLACE AND ESTABLISHED. 8. THE EROSION CONTROL MEASURES ARE INTENDED AS MINIMUM STANDARDS. ANY EROSION CONTROL REQUIRED BEYOND THAT SPECIFIED SHALL BE CONSIDERED AS INCLUDED WITHIN THIS CONTRACT. 9. IF OFFSITE TURBIDITY BECOMES EXCESSIVE, CONTRACTOR IS RESPONSIBLE FOR INSTALLING FLOC BLOCS AS NEEDED. 10 10. IN THE EVENT OF EXCESSIVE OFF -SITE TRACKING, THE CONTRACTOR WILL BE OBLIGATED TO INSTALL ADDITIONAL MEASURES. WHERE GRADE EXCEEDS 2% EXISTING 2% OR GR p tER P FILTER FABRIC SECTION A —A A FLOW 0 U_ DIVERSION RIDGE z 3 0 W xa�=:A W d G i NOTE: IN THE EVENT OF EXCESSIVE OFF -SITE TRACKING, THE CONTRACTOR WILL BE OBLIGATED TO INSTALL ADDITIONAL MEASURES TEMPORARY GRAVEL CONSTRUCTION ENTRANCE DETAIL TYPE III FILTER FABRIC (IN CONFORMANCE WITH SEC. 985 FDOT SPEC.) I� OR - n.- 102 . 94PI N.T.S. SECTION 'ILTER FABRIC LT FLOW SILT FLOW NOTE: SILT FENCE PROTECTION SPACING FOR SILT FENCE TO AROUND DITCH BOTTOM INLETS. BE IN ACCORDANCE WITH PLANS AND SPECIFICATIONS SILT FENCE APPLICATIONS N.T.S. Cnz uA Z U z` 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Selby G. Weeks 56991 9 revision description date Al AGENCY COMMENTS 03.16.23 0 SJRWMD PAC 04.21.23 Q3 CITY COMMENTS o6.26.23 ® CITY COMMENTS 07.27.23 0 0 drawn by: JD checked by: SGW date: O$/05/2022 plot scale: AS SHOWN project number: N/A file name:C2oo-DEMO-WEST-21TSGDoo1.DWG C •• Filename : C200-DEMO-WEST-21TSGDOOt.dwg Plot Date : Aug. 01, 2023 9:50am Page 544 of 593 i � 7' STANDARD Y/Y RPMs, TYP. 2 0 6" DOUBLE YELLOW, 6" WHITE THERMOPLASTIC 0 THERMOPLASTIC EDGE LINE �' �CROSSWALK, WHITE S 4 1 7' STANDARD ®�-- HE - L�S-4D THERMOPLASTICS CROSSWALK, WHITE Se4 4 WIDE YELLOW FIRE R3 a, - CONCRETE WHEELSTOP, TYP. LANE S RIPING LANE STRIPING I (TRAFFIC PAINT, TYP.) (TRAFFIC PAINT, TYP.)) z 33.00 r - -.. - 67.00' CD �- BUILDING WALL BEARING II I rn Q c?- 00 TYPE "D" CURB, TYP. �_� 15 I - - .. U, 5' CONCRETE WALK, TYP. �� 1 4' CONCRETE F UME I WITH EN RGY 1 1 DISSIPATER (TYP.) .� � � I 1 <c ® N PROPOSED 1 POND _ f/l - x - I N � = - 1- 9'x20' PARKING SPACE' z `1 o ® 16 °� CURB RAMP' �x o CR---C BUILDING boo 1 4 0 a 7ioo8' SF 0 S®2 i 120.00 � 4„ WIDE YELLOW FIRE I oo LANE STRIPING _... STACKED STONE RETAINING WALL. WITH 4' �`' a i (TRAFFIC PAINT, TYP.) BLACK VINYL CHAIN LINK FENCE. CONTRACTOR 2- 12 x20 ACCESSIBLE PARKING SPACES W/ SHALL DELIVER WALL DESIGN -BUILD. PROVIDE 24,00' I 5' WIDE ACCESS AISLE. REFER TO SHEET DUMPSTER NCLOSURE ENGINEERED WALL DRAWINGS, SIGNED AND . - L C600 FOR REQUIRED STRIPING AND SIGNAGE (REFER TO RCHITECTURAL SEALED BY A FLORIDA REGISTERED STRUCTURAL ° PLANS FOR DETAILS) m ENGINEER. PROVIDE SHOP DRAWINGS FOR 12 I _.2- 9'x20' PARKING SPACES' m TYPE "F" CURB & JOOO/ CONFIRMATION OF WALL HEIGHT. CURB AMP C % GUTTER 1 R S-2 -c 1 �x Ui -- 2- 12 x2Q ACCESSIBLE PARKING SPACES W/ 5' WIDE ACCESS ;AISLE. REFERTO SHEET H C600 FOR REQUIRED STRIPING AND SIGNAGE94 ' a 1 e - 00 w a x w� 1- 9'x20' PARKING SPACE C0', I x z � 1 - 40 oQ Ell CD o� 1 1 18 V) LJ 4 TYPE „D" CURB, TYP. f-- �- M X { _ 20 ' 00, DIRECTIONAL ARROWS, - -- WHITE TRAFFIC PAINT, TYP. S� 1 26 30 0_1I7n'N4T7rPuv'XTnrPT7c THREE (3) FOOT CURB TRANSITION SHALL BE PROVIDED AT ALL CURB TERMINATIONS I EXCEPT WHERE CURB ABUTS RAISED WALK. POINTS SHOWN ON THE PLANS HAVE BEEN SET AT FACE OF CURB, PC, PT, CURB MIDPOINT AND INTERSECTIONS LOCATIONS. POINTS SHOWN ON UTILITY & STORM STRUCTURES ARE AT THE CENTER OF THE STRUCTURE, I REFER TO GRADING PLANS FOR LIMITS OF FLUSH AND RAISED CONCRETE WALKS. DISPOSITION OF WALK/ASPHALT INTERFACE IS PROVIDED BY SPOT ELEVATIONS. 5 R1-1 S-1 STOP "STOP" SIGN (30" HIGH INTENSITY GRADE SIGN). 24" WIDE STOP BAR (WHITE THERMOPLASTIC). s2 1 O � -!> ! HANDICAP PARKING SIGN. PARKING BY REFER TO SHEET C600 DISABLED FOR DETAIL. PERMIT ONLY [$250 FINE GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) lSUM1111111 HIM ll S43 TYPE 4 OM4-3 ALL RED RETROREFLECTIVE OBJECT MARKER R8-3A S-4 DOUBLE SIDED, NO (I ) PARKING SIGN IN R/W, SPEED R2-1 CSCC 23 MPH SPEED LIMIT LIMIT SIGN. 25 COORDINATE POINT TABLE: Point Table Point # Description Northing Easting 1 PL 1543881.5848 478108.2035 2 PL 1543893.5259 478619.1419 3 PL 1543768.3363 478608.5606 4 PL 1543452.0710 478567.4965 5 PL 1543242.6610 478568.2858 6 PL 1543242.1937 478551.2324 7 PL 1543362.2129 478550.2910 8 PL 1543350.2126 478112.3716 9 BLDG. CORNER 1543819.7829 478195.5095 10 EOP 1543801.3962 478124.5927 11 EOP 1543708.4053 478125.8919 12 EOP 1543595.4921 478127.4693 13 EOP 1543493.5021 478128.8942 14 EOP 1543816.3368 478186.3900 15 EOP 1543741.3441 478187.4377 16 EOP 1543657.3523 478188.6111 17 EOP 1543551.3626 478190.0919 18 EOP 1543467.3708 478191.2653 19 EOP 1543348.2983 478102.3864 20 EOP 1543412.2974 478101.8843 21 EOP 1543832.5700 478120.1258 22 EOP 1543859.1250 478115.2440 23 EDP 1543882.9580 478657.3769 24 EDP 1543855.9654 478658.0086 25 WALL 1543817.0989 478419.4021 26 WALL 1543407.9468 478425.1182 27 CL 1543380.7733 478138.4699 28 CL 1543381.0806 478160.4677 29 CL 1543385.0199 478442.4402 30 CL 1543401.7488 478458.7081 31 CL 1543864.6549 478452.2410 32 CL 1543851.7026 478149.5340 33 CL 1543845.8475 478117.6849 34 CL 1543869.4617 478657.6928 35 POND 1543830.6500 478495.1731 36 POND 1543825.5815 478490.2906 37 POND 1543375.8137 478496.5741 38 POND 1543370.8854 478501.7105 39 POND 1543371.7505 478533.2800 40 POND 1543512.4494 478535.1456 41 POND 1543643.2805 478553.7525 42 POND 1543833.5967 478578.4069 0 z uu Z U z 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Selby G. Weeks 56991 9 revision description date Al A 0 0 0 AGENCY COMMENTS 03- 6.23 SJRWMD PAC 04.21.23 CITY COMMENTS o6.26.23 CITY COMMENTS 07.27.23 drawn by: JD checked by: SGW date: 08/05/2022 plot scale: AS SHOWN project number: N/A file name:C3oo-GEOM-WEST-21TSGDoo1.DWG Filename : C300-GEOM-WEST-21TSGDOOt.dwg Plot Date : Aug. 01, 2023 9:50am Page 545 of 593 A t s SLOPE FROM BACK OF CURB TO EXISTING GRADE AT 4:1 MAX SLOPE (TYP.) PROPERTY LINE 11899 121.23 - 18 ��� . . .........�• . 120.85 D-03 121.53-- -- - 118.61 39LF 15" 118.50 119.99 121.15 120.85 39LF 15" 119.61 / 118.88 RCP @ 0°30% 118.12 . 121.12 RCP @ 0.30% I ° tt8.39 135LF 15 � -- ' 121.98 121.42 -- 121.48 _ �- 120.85 D-02 ,19. 8 119.99 118.61 D-04 118.08 118.12RCP @ 0.30% 117.67 122.251 121.25 ' 121.52 120.07 119.61 121.75 121.98 121.15120.95 223LF 15 RCP @ 0.30% 118.45 01 / 121.48.5 121.54 � ° T� 120.13 119. ' rf" 11862 118.01 117.84 117.73 4' BLACK VINYL 1 118.40t(MEG) 1 118.40t(MEG) e - 121.65 -OF-WAY LINE rx I 122.07 12,.54 21.o FUTURE RIGHT 0 �,=-�-TOP 0� _ - I 1 ,-y HEADWALL 119.90 C .0. INV.=109..- . _ 01 �22.24 ..J D-07 �i j �� 0 0 ° N 1 15.50 . (TYP. OF 29 � li i � .I `' 00 0 � , � � t 121.37 122.19 112.25 000 000 4' BLACK VINYL I B ❑00❑ ❑0❑ 121.69 122.43 02 $.L4 L �11225 co 00 000 ,' ' CHAIN LINK FENCE 122.48 = r WINGWALLS TERMINATE 117.68/ i 21.82 m ® t ; AT 113 CONTOUR ,22.48 ,18.42 117.3d i m� ; WI 122.40T. BOTH SIDES H TOP=114°50, 1122.40 „TYP8. 0 - 121.90 121.60 w ~ 121.90 i �i _J= I I o I 45LF 6 PVC " i Cl- __J � r 21.76 118.50 121.26 D 13 ( 121.90 121.95 0 0 ® SURFACE WATER �141 121.40 w - w r" r cl 00 ' IMPACTS= 0.03AC C°0. a- ii 00 ® 2 121.68 INV.=109°58 ® " ® i , D-14 121.18 10LF =D 121.43 s w 9LF o , 1t2. � w i w i ( 120.93 O 118.50 i 10LF c' -� o � � � 40 LF 18 .116.86 12156 CD�' RCP @ 0.30% ( 120. 121;06 " D-08 �� �. CL •4 121.44 121.96 ROOF DRAIN TO o s v A -A 120:96 SPILL TO GRADE z 7oo � (TYP.) 'L C, C- 10LF - LIMIT OF SURFAC WATERS IS T0l .- ® � i OF DITCH. AREA OF SURFACE ' C' ;; i ( 121.74 WATER WITHIN SITE = 0°31 AC ® , i 121.24 118.50 0Ln --Ln o o CLAY CORE, 121.60 CD ® > REFER TO DETAIL, ,2,.,d ,22.,1 BUILDING 600 � �- � � ,� �, SHEET C700 121.93 ro o w a 121.61 o w w 1, 121.43 ° o ' o 122.16 FF= 122.50 121.4t w x 122.31 0Ln CD 121.81 cL N' "10LF' i 121.76 1, 8.50 118.36 117.68 k 21.56 1 7.97 o l �r o 117.30 ,; i �` 122.22 b 122.40 w FEMA FLOODPLAIN 118.41 o w w 121.72 121.90 118.11 �, LINE 122.48 n o 21.70 122.33 o a 121.83 122.48 a- i i 122.13 _-- ---117.7 i 121.63 21.63 122°40 ° 122.48 ' 118.50 __ 111-T_4 z w -----------.---- n 121.51 121.90 m a 10L11 ' 122.48 �18 39 118. 4 122.31 ; 117.7 122.17 121.70 121.81 - 117.33 Q D 121.67 -1 1118.11 xr 21.56 121.76 ,18.50 1 118.28 118.30 Q o i; b 122.16 118.41 C' ® CD i W IVY,h 121.41 121.93 121.61 121.43 ►•.� o ( _, 21.60 121.98 w w 121.10 w i i °C 121.74 121.7Ln 9 121.24 i 118.50 o 120.58 121.40 121.45 Q 120.88 D-09 120.90 ° oo i (I 10LF 1 i i 5-1 d 0 r CL iu U N i 0 i 0 N 0 a v c 0 i N 0 0 J N �i Rename : C400-GRAD-WEST-21TSGD001.dwg Plot Date : Aug. 01, 2023 9:51am a CONCRETE DUMPSTER PAD a CONCRETE WALKS 100.50 100.00 PROPOSED SPOT GRADE t MATCH EXISTING GRADE EXISTING SPOT GRADE PROPOSED DRAINAGE FLOW - - - - - - GRADE BREAK LINE 125.63 TW TOP OF WALL GRADE 124.93(4) BOTTOM OF WALL GRADE E/P EDGE OF PAVEMENT FLEXAMAT TIED CONCRETE MAT SYSTEM ON 177-7-7-7-77-71 0000000 MIRAFI 160N NONWOVEN GEOTEXTILE PER 0000000 0000000 - FDOT INDEX No. 1999 2007 TYPE 0 E ( ) (OR EQUIVALENT) PERMANENT TURF REINFORCEMENT MAT (NORTH AMERICAN GREEN VMAX SC250 OF ACCEPTED EQUIVALENT). INSTALL PER MANUFACTURER SPECIFICATIONS AND TOE -IN ON ALL EDGES (1' MIN.) SURFACE WATER LIMITS ON -SITE - - - - - - - - - SURFACE WATER IMPACTS .� 2 STORM STRUCTURE TABLE: D 0 ID TYPE "V" INLET E/P= 120,85 S. INV°= 116.90 D-02 TYPE "V" INLET E/P= 120°85 N, INV,= 116°78 E° INV.= 115.54 D-03 TYPE "V" INLET E/P= 118.61 S. INV.= 114.87 D-04 TYPE "V" INLET E/P= 1 1 &61 N INV.= 11435 M INV.= 114.87 E° INV.= 113.90 D- 55 TYPE "V" INLET E/P= 117.24 S. INV.= 113.49 STORM KEYNOTES: GRAPHIC SCALE :, � � �1 �1111111111 IN SURFACE WATER IMPACTS: TOTAL SURFACE WATER IMPACTS: 0.16 AC Z� 0-06 TYPE "V" INLET E/P= 117.24 N. INV.= 11137 W. INV.= 11149 S. INV.= 112.36 D 07 18" MITERED END SECTION INV.= 112.25 D-0„8 TYPE "C" INLET TOP= 120.64 S, INV.= 117°14 D-09 TYPE C INLET TOP= 120.58 N. INV.= 116°60 S. INV.= 116.35 D-10 TYPE "C" INLET W/ J BOTTOM TOP= 121.70 N. INV.= 116.15 E. INV.= 114.46 1 D-11 TYPE "C" INLET W/ J BOTTOM TOP= 118.12 W. INV.= 114°04 NE. INV.= 112,40 01 CROSSWALK CROSS -SLOPE SHALL NOT EXCEED 2% 02 REFER TO ARCHITECTURAL PLANS FOR RAMP DESIGN GRADING AND DRAINAGE NOTES: �D 12 18" MITERED END SECTION INV.= 112°25 D- 33 TYPE "C" INLET CONTROL STRUCTURE (REFER TO C700 FOR DETAILS) 1� TOP= 116.10 WEIR=114.11 W. INV.=109.58 E. INV.=108.37 BOTTOM=108.16 0-1..4 18" MITERED END SECTION INV.= 108.25 D-15 6'X4' BOX CULVERT W/ WINGWALL FDOT INDEX 400-292 INV°= 108.00 D-16 6'X4' BOX CULVERT W/ WINGWALL FDOT INDEX 400-292 INV.= 107.92 1. CONTRACTOR SHALL VERIFY EXISTING TOPOGRAPHIC DATA, LOCATION OF EXISTING UTILITIES AND ALL OTHER SITE CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. 2. ALL GRADING AND SITE PREPARATION SHALL CONFORM TO SPECIFICATIONS CONTAINED IN THE PROJECT GEOTECHNICAL INVESTIGATION AND RECOMMENDATIONS, AND SPECIFICATION SECTIONS 31 10 00 AND 31 20 00. 3. ALL GRADES SHOWN, WITH THE EXCEPTION OF THOSE INDICATED ON THE SURVEY BASE DRAWING, ARE FINISHED GRADES UNLESS INDICATED OTHERWISE. 4. ALL AREAS DISTURBED BY CONSTRUCTION ACTIVITIES SHALL BE GRADED TO ORIGINAL GROUND LINES AND FINISHED WITH SOD PER PROJECT SPECIFICATIONS UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL MAINTAIN ALL AREAS UNTIL FINAL ACCEPTANCE. 5. STORMWATER COLLECTION SYSTEM TO BE PRIVATELY OWNED AND MAINTAINED. 6. INLET AND MANHOLE ELEVATIONS ARE TOP OF RIM. 7. ALL INLET AND MANHOLE TOPS SHALL BE TRAFFIC BEARING UNLESS OTHERWISE NOTED. 8. SIDEWALKS AND CROSSWALKS: a. CROSS -SLOPES SHALL NOT EXCEED 2.0% b. LONGITUDINAL SLOPES SHALL NOT EXCEED 5.0% EXCEPT CURB RAMPS. c. CURB RAMP LONGITUDINAL SLOPES SHALL NOT EXCEED 12:1. 9. ACCESSIBLE PARKING SPACES, ACCESS AISLES AND PASSENGER LOADING ZONES: a. SLOPES SHALL NOT EXCEED 2.0% IN ANY DIRECTION. PROJECT BENCHMARK: SOURCE: BOUNDARY AND TOPOGRAPHIC SURVEY OF 701, 707 AND 711 PINE STREET, OCOEE, FLORIDA, SECTION 18, TOWNSHIP 22 SOUTH, RANGE 28 EAST, ORANGE COUNTY, FLORIDA, DATED JANUARY 5, 2022. SURVEYOR: BILLY JOE JENKINS JR., PSM. THE ELEVATIONS SHOWN HEREON ARE BASED ON ORANGE COUNTY VERTICAL CONTROL NETWORK. SPECIFICALLY, BENCHMARK NUMBER C1051016. PUBLISHED ELEVATION IS 122.74 FEET, RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM (NAVD) OF 1988, SUBJECT PROPERTY LIES WITHIN ZONE X, AN AREA DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN, AND ZONE AE, AND AREA WHERE BASE FLOOD ELEVATIONS ARE DETERMINED (114') ACCORDING TO THE NATIONAL FLOOD INSURANCE PROGRAM, FLOOD INSURANCE RATE MAP NUMBER 12095CO210H, DATED SEPTEMBER 24, 2021. Cnz ck uJ s U' z UA 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Selby G. Weeks 56991 9 revision description date Al AGENCY COMMENTS 03.16.23 0 SJRWMD PAC 04.21.23 Q3 CITY COMMENTS o6.26.23 ® CITY COMMENTS 07.27.23 0 0 drawn by: JD checked by: SGW date: O$/05/2022 plot scale: AS SHOWN project number: N/A file name:C400-GRAD-WEST-21TSGDoo1.DWG Page 546 of 593 CONNECT TO 4" DIP WATER MAIN WITH 4%2" TAPPING = SADDLE AND 2" GATE VALVE Al i TERMINATE WATER MAIN WITH 4" GATE VALVE AND 2" BLOW -OFF. (REFER TO ' SHEET C802 FOR DETAIL) 2" POLYETHYLENE WATER SERVIC , 23'x10' CITY WATER EASEMENT -I 4 1.5 -1NR 'ATION METER AND 2" REDUCED PRESSURE BACK FLOW PREUENTER (REFER TO IRRIGATION PLANS FOR CONTINUATION)' 18" WIDE x 60" LONG CONCRETE PAD PER DETAIL UT209B, SHEET C801 3 / 5-1 d 0 r U G m N i 0 i 0 N 0 a v G C / M V O Nc O O J N �i Filename : C500—U11L—WEST-21TSGD001.dwg Plot Date : Aug. 01, 2023 9:53am 1� CONNECT TO 4" DIP WATER MAIN WITH 4%2" TAPPING SADDLE AND 2" GATE VALVE 0 -131LF4"DIP /'- � FIRE HYDRANT rt FUTURE RIGHT-OF-WAY LINE 18" WIDE x 62" LONG CONCRETE PAD PER DETAIL �- UT209B, SHEET C801 CLEANOUT `� 3 INV. 115.90 0 " 15" DOMESTIC' WATER 62LF 6" PVC 6 METER AND 2" @ 1.00/ REDUCED PRESSURE REFER TO PLUMBING BACKFLOW PREUENTER PLANS FOR WATER 8" TEE 3 SERVICE CONTINUATION. 8" GATE VALVE 1O'x10' CITY WATER 0 EASEMENT .18 PVC (PRIVATE) 4" DIP (CITY) WATER MAIN \ CD (PUBLIC) PROPERTY LINE 1�.. 3" CHECK 45-DEGREE 0 VALVE BEND, TYP. — — -- 12%8" REDUCER 12" C900 DR-18 PVC U WATER MAIN (PRIVATE) zkj ��� NOTE: ADJUST ALL EXISTING VALVE BOXES A1 4 — — — — TO PROPOSED GRADE. 0 255LF 3" i .. HDPE DR-11Ift 3" HDP DR-1 1 VERTICAL 45-DEGREE FARCE MAIN (PRIVATE) BENDS (4) FIRE HYDRANT --.— 12' x6" TEE VERTICAL 45-DEGREE 6VALVE " BENDS (4) ...CAE I — FORCE MAIN AIR RELEASE VALVE I I x ,I � l 8" C900 DR-18 Rawan PVC WATER MAIN (PRIVATE) 1 � I I I i PROPOSED j POND I I I ' I 6„ C900 DR-14 I 8"x6" TEE PVC FIRE LINE PIV (FIRE LINE POS) — FDC m -•-- FIRE HYDRANT 8%8" TEE 8" GATE VALVE I �� I � 8" C900 DR-18 PVC WATER MAIN qq q. I I I I ( i� I � �X CONNECT TO 3" PLUG VALVE. REMOVE BLOW -OFF AND CONNECT TO 12" GATE VALVE. NFPA FIRE FLOW CALCULATIONS: BASIS: NFPA 1, 2018, CHAPTER 18 CONSTRUCTION TYPE: TYPE II-B (FL. BLDG. CODE) FIRE AREA: 70,014 SF MIN. REQUIRED FIRE FLOW: 5,500 GPM SPRINKLER CREDIT: YES GRAPHIC SCALE THEREFORE MIN. REQUIRED FIRE FLOW e 1,375 GPM 30 0 15 30 60 TOTAL HYDRANTS REQUIRED: 1 (WITHIN 250 FT OF BUILDING) PROPOSED HYDRANTS: 4 WITHIN 250 FT OF BUILDING IN FEET UTILITY NOTES: 1. ALL WATER & WASTEWATER MAIN MATERIALS AND APPURTENANCES SHALL CONFORM TO AND SHALL BE INSTALLED, TESTED AND CLEARED FOR SERVICE IN ACCORDANCE WITH THE STANDARDS OF THE CITY OF OCOEE UTILITIES AND THE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION. 2. HORIZONTAL SEPARATION BETWEEN WATER MAINS AND SANITARY OR STORM SEWER, WASTEWATER OR STORMWATER FORCE MAINS, AND RECLAIMED WATER PIPELINES, AND ON -SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS. A. WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST THREE (3) FEET BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OF PROPOSED STORM SEWER, STORMWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER, REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C. B. WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST TEN (10) FEET BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED VACUUM -TYPE SANITARY SEWER. C. WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST TEN (10) FEET, BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED GRAVITY OR PRESSURE TYPE SANITARY SEWER, WASTEWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER NOT REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C. THE MINIMUM HORIZONTAL SEPARATION DISTANCE BETWEEN WATER MAINS AND GRAVITY TYPE SANITARY SEWERS SHALL BE REDUCED TO THREE (3) FEET WHERE THE BOTTOM OF THE WATER MAIN IS LAID AT LEAST SIX (6) INCHES ABOVE THE TOP OF THE SEWER. D. WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST TEN (10) FEET BETWEEN THE OUTSIDE OF THE WATER MAIN AND ALL PARTS OF ANY EXISTING OR PROPOSED ON -SITE SEWAGE TREATMENT AND DISPOSAL SYSTEM. VERTICAL SEPARATION BETWEEN WATER MAINS AND SANITARY OR STORM SEWER, WASTEWATER OR STORMWATER FORCE MAINS, AND RECLAIMED WATER PIPELINES. A. WATER MAINS CROSSING ANY EXISTING OR PROPOSED GRAVITY OR VACUUM -TYPE SANITARY SEWER OR STORM SEWER SHALL BE LAID SO THE OUTSIDE OF THE WATER MAIN IS AT LEAST TWELVE (12) INCHES ABOVE THE OUTSIDE OF THE OTHER PIPELINE. B. WATER MAINS CROSSING ANY EXISTING OR PROPOSED PRESSURE TYPE SANITARY SEWER, WASTEWATER OR STORMWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER SHALL BE LAID SO THE OUTSIDE OF THE WATER MAIN IS AT LEAST TWELVE (12) INCHES ABOVE THE OUTSIDE OF THE OTHER PIPELINE. C. AT THE UTILITY CROSSINGS DESCRIBED IN PARAGRAPHS (A) AND (B) ABOVE, ONE FULL LENGTH OF WATER MAIN PIPE SHALL BE CENTERED ABOVE OR BELOW THE OTHER PIPELINE SO THE WATER MAIN JOINTS WILL BE AS FAR AS POSSIBLE FROM THE OTHER PIPELINE. ALTERNATIVELY, AT SUCH CROSSINGS, THE PIPES SHALL BE ARRANGED SO THAT ALL WATER MAIN JOINTS ARE AT LEAST THREE (3) FEET FROM ALL JOINTS IN VACUUM -TYPE SANITARY SEWERS, STORM SEWERS, STORMWATER FORCE MAINS, OR PIPELINES CONVEYING RECLAIMED WATER AND AT LEAST SIX (6) FEET FROM ALL JOINTS IN GRAVITY OR PRESSURE -TYPE SANITARY SEWERS, WASTEWATER FORCE MAINS, OR PIPELINES CONVEYING RECLAIMED WATER REGULATED UNDER PART III OF CHAPTER 62-610 F.A.C. 3, ALL ON -SITE UTILITIES SHALL BE PRIVATELY OWNED AND MAINTAINED. 4. CONTRACTOR SHALL NOTIFY THE CITY OF OCOEE UTILITIES DEPARTMENT 48 BUSINESS HOURS PRIOR TO ANY UTILITIES CONSTRUCTION. 5, ALL UNDERGROUND FIRE MAINS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 24, 2007 EDITION, "STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES [F.A.C. 69A-60.005 (2)]. 6. TAPS FOR FIRE, WATER, AND IRRIGATION LINES MUST BE AT LEAST SIX (6) FEET APART. 7. ALL IMPROVEMENTS TO BE DEDICATED AND/OR MAINTAINED BY THE CITY SHALL BE IN CONFORMANCE WITH THE CURRENT CITY OF OCOEE ENGINEERING MANUAL AND DETAILS. FINAL PLAN APPROVAL DOES NOT PROVIDE EXEMPTION TO THESE REQUIREMENTS. 8. ANY DEVIATION FROM THE CITY OF OCOEE ENGINEERING STANDARDS AND DETAILS MUST BE APPROVED IN WRITING PRIOR TO CONSTRUCTION. 9. THIS PROJECT, INCLUDING BOTH HORIZONTAL AND VERTICAL CONSTRUCTION, SHALL INCORPORATE WATERSENSE PLUMBING FIXTURES AND ENERGY STAR APPLIANCES 10. THE MOST STRINGENT STANDARDS BETWEEN THE CITY OF OCOEE AND FDEP STANDARDS KEYNOTES: 01 CONNECT TO SANITARY SERVICE LINE AT INVERT 116.00 WITH 6" PVC. EXTEND TO 6" SANITARY LINE AT 1.00% MIN. REFER TO PLUMBING PLANS FOR SANITARY SERVICE CONTINUATION. Cnz ac uu ' Z U z` 385 Douglas Avenue, Ste 2100 Altamonte Springs, FI_ 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Selby G. Weeks 56991 9 revision description date Al AGENCY COMMENTS 03.16.23 0 SJRWMD PAC 04.21.23 Q3 CITY COMMENTS o6.26.23 A CITY COMMENTS 07.27.23 0 0 drawn by: JD checked by: SGW date: O$/05/2022 plot scale: AS SHOWN project number: N/A file name:C5oo-UT1L-WEST-21TSGD001.DWG Page 547 of 593 125.00 120.00 115.00 110.00 105.00 HORIZONTAL SCALE: 1" 20' VERTICAL SCALE: 1" 10` * NOTE: THE PROFILE SHOWS THE UTILITIES OVERLAID IN PROFILE WITH THE CENTERLINE OF THE PROPOSED ROADWAY. THE 3` MINIMUM COVER REQUIREMENT IS FROM FINISHED GRADE AT EACH UTILITY, NOT FROM THE CENTERLINE OF THE ROAD GRADE. �������� ���&�� GRAPHIC ^^^^z�u�"� /3\ � IN FEET � ocK^nxc o/nox_ncc ^un ^nuucrr EXISTING ROAD PAVEMENT 125.80 120.00 115.00 110.00 105.00 60 385 Douglas Avenue, Ste 2100 A|tornVnto Springs, F[ 32714 Telephone 407.478.8750 F000lrnOw 407.478.8749 Selby G. Weeks 56991 Al 9 revision date Al� AGENCY COMMENTS 03.16.23 CITY COMMENTS o6.26.23 CITY COMMENTS 07.27.23 drawn by: JD checked by: SGW date: o8/05/2022 plot scale: AS SHOWN project number: N/A � � Rename ; T3&D00dwg Plot Date ; Aug 0, 2023 9:53om Page 548 of 593 2" POLYETHYLENE WATER SERVICE (PUBLIC) 4" C900 DR-18 PVC FORCE MAIN (PUBLIC) 4" DIP (CITY) WATER CONNECT TO 4" DIP WATER REMOVE BLOW -OFF MAIN (PUBLIC) MAIN WITH 4"x2" TAPPING AND CONNECT TO 4" SANITARY FORCE SADDLE AND 2" GATE VALVE 4" GATE VALVE. „; CONNECT TO 4" DIP WATER MAIN MAIN STUB WITH 4" 2 POLYETHYLENE 4" DIP (CITY) » �� WITH 4 x2 TAPPING SADDLE PLUG VALVE � CONNECT TO „ WATER SERVICE (PUBLIC) WATER MAIN - � MAIN WITH 4 x2 TAPPING (PUBLIC) SADDLE AND 2" GATE VALVE PROPERTY LINE �.���.��.������ a 4 PLUG VALVE a ---- -_—.— -- - -- _; -- 99 ., CONNECT TO 3 AIR RELEASE VALVE 12 C900 DR-18 PVC - - 2" POLYETHYLENE - WATER SERVICE (PUBLIC) . FIRE HYDRANT _ 3" HDPE DR-1 1 _��'_ C9 R-18 PVC PLUG VALVE. WATER MAIN (PRIVATE) --..PC MAIN PRIVATE) L WATER MAIN (PRIVATE) am - Ewa i d 0 r a irs U C m N i 0 i 0 N 0 a v c a� 0 0 Nc O 0 O J N �i Filename : C500—U11L—WEST-21TSGD001.dwg Plot Date : Aug. 01, 2023 9:54am 3" CHECK VALVE 8" PVC SANITARY SEWER , SANITARY MANHOLE 2 CONNECT TO 4" DIP WATER MAIN" WITH 4"x2" TAPPING SADDLE AND 2" GATE VALVE (PUBLIC) CONNECT TO 4" DIP WATER WITH 4"x2" TAPPING SADDLE AND 2" GATE VALVE 4" GATE 4" PLUG 2" POLYETHYLENE IRRIC VALVE VALVE % SERVICE (PUBLIC) C900 DR-18�` PVC SANITARY 4" PLUG FORCE MAIN I VALVE (PUBLIC) 8" C900 DR-18 PVC WATER MAIN (PRIVATE) -- GRAPHIC SCALE 50 0 25 50 100 ( IN FEET Cnz ac uA s t9 z 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Selby G. Weeks 56991 9 revision description date Al AGENCY COMMENTS 03.16.23 0 SJRWMD PAC 04.21.23 0 CITY COMMENTS o6.26.23 ® CITY COMMENTS 07.27.23 0 0 drawn by: JD checked by: SGW date: O$/05/2022 plot scale: AS SHOWN project number: N/A file name:C5oo-UT1L-WEST-21TSGD001.DWG C502 Page 549 of 593 WALK WIDTH VARIES (SEE PLAN) 6" CONCRETE SLOPE PER PLAN 4"X 4"-4X 4 W.W.M. 6" COMPACTED SUBGRADE 98% AASHTO T-180 1" WATERPROOF ELASTIC CAULK 1/2" ELASTIMETRIC EXPANSION JT. MATERIAL .J L_ 1 /2' EXPANSION JOINT HAND TOOLED OR FORMED DEPTH = d"/4 d CONTRACTION JOINT NOTES: 1. SIDEWALK W/UGHT BROOM FINISH & TROWELED EDGE. 2. FOR APPLICATIONS WHERE SIDEWALKS ARE ADJACENT TO GRASSED AREAS, THE GRASS AREA SHALL NOT EXCEED A 3% SLOPE FOR A MINIMUM OF 5 FEET. 3. CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 PSI CONCRETE AT 28 DAYS 4. ALL CONCRETE SIDEWALKS SHALL HAVE A FULL 1/2- EXPANSION JOINT AT A MAXIMUM DISTANCE OF 40 LINEAR FEET AND A SAW CUT OR FORMED DUMMY CONTRACTION JOINT AT EVENLY SPACED INTERVALS NOT TO EXCEED WIDTH OF THE WALK OR 8 LINEAR FEET WHICH EVER IS THE SMALLEST. 5. AN I" CONSTRUCTION JOINT SHALL BE CONSTRUCTED AT ALL P.C. AND P.T. OF CURVES AND WHERE EXISTING AND NEW SIDEWALKS MEET. 6" CONCRETE WALK DETAILS N.T.S. 12' PARKING By DISABLED PERUT ONLY 00 FTP-55 1 " FC-9.5 ASPHALTIC CONCRETE 2.5" SP-12.5 ASPHALTIC CONCRETE ............................................. .............................................. ......................................... 10" CRUSHED CONC. COMPACTED TO 98% OF THE MODIFIED PROCTOR (ASTM D-1557 AASHTO T-180), MAX. DENSITY, LBR 150 MIN., MEET FDOT SECTION 334 AND GRADATION REQUIREMENTS PER SECTION 911-3.4. 12" THICK FREE -DRAINING SAND SUB -BASE STABILIZED TO 98% OF THE MODIFIED PROCTOR (ASTM D-1557 AASHTO T-180), MIN. DENSITY. STABILIZING MATERIAL, IF USED, SHALL BE COARSE MATERIAL (e.g. GRAVEL). LOW PERMEABILITY (e.g.; SILT AND/OR CLAY) SHOULD NOT BE USED AS STABILIZING MATERIAL BENEATH CONCRETE PAVEMENT. HEAVY DUTY ASPHALT PAVEMENT SECTION N.T.S. PAVEMENT WIDTH VARIES (SEE PLAN #4 REBAR(CONTINUOLIS) 899 299 SLOPE PER PLAN 5 4 4*'.. 210 299 6 x 6 10/10 WWF FLEXIBLE PAVEMENT 12" THICK SUB —GRADE COMPACTED TO 98% OF THE MODIFIED PROCTOR (ASTM D-1557, AASHTO T-180), MIN. DENSITY. LBR 40 MIN. STABILIZING MATERIAL SHALL BE COARSE MATERIAL (e.g. GRAVEL). LOW PERMEABILITY (e.g.; SILT AND/OR CLAY) SHOULD NOT BE USED AS STABILIZING MATERIAL BENEATH CONCRETE PAVEMENT. NOTES: 1. ALL CONCRETE PAVEMENT SHALL HAVE A FULL, Y2" ISOLATION JOINT WHERE IT ABUTS EXISTING CONCRETE PAVEMENT AND OTHER RIGID STRUCTURES, SUCH AS BUILDING FOUNDATIONS AND WALLS. PROVIDE 2" SAW CUT OR DUMMY CONTRACTION JOINT AT EVENLY SPACED INTERVALS NOT TO EXCEED 20 FEET. 2. PORTLAND CEMENT CONCRETE PAVEMENT TO BE 4,000—PSI COMPRESSIVE STRENGTH, MIN. NOTES: PROVIDE 18" OF CLEAN, FREE DRAINING SAND SUBGRADE BENEATH CONCRETE PAVEMENT. COMPACT BOTTOM 6" TO 98% OF THE MODIFIED PROCTOR (ASTM D-1557, AASHTO T-180). -CONTRACTOR SHALL COORDINATE SIGN INFORMATION PERTAINING TO FINES PER LOCAL JURISDICTION (F.S. 316.1955, 318.18) 4" BLUE STRIPE REFER TO BOLLARD SIGN DETAIL FOR POST AND FOUNDATION. 4" WHITE STRIPE GRADE HANDICAP PARKING SIGN DETAIL N.T.S NOTES 1. TOP PORTION OF FTP 25 & 26 SHALL HAVE A REFLECTIVE SYMBOL AND BORDER. 2. BOTTOM PORTION SHALL HAVE A REFLECTIVE WHITE BACKGROUND WITH BLACK OPAQUE LEGEND AND BORDER. 3. FTP 25 & 26 MAY BE FABRICATED ON ONE PANEL OR TWO. 4. FTP 25 MAY BE SUBSTITUTED FOR THE FTP 26 IN AREAS WHERE SPACE IS LIMITED. 5. SIGNS ARE TO BE MOUNTED AT STANDARD HEIGHT. (7'-6" FROM PAVEMENT TO BOTTOM OF SIGN). CONCRETE PAVEMENT DETAIL N.T.S. NOTE: PAINT SYMBOL BELOW ONTO PAVED SURFACE W/ 2 COATS OF TRAFFIC BLUE PAINT, MANUF. PER FLA. DEPT. OF TRANSPORTATION SPECS. 12' 12' 4" BLUE STRIPE 4" WHITE STRIPE arm In 5! 5 4" TYP. I-011 4 12" SOLID WHITE @ 45% 30" O.C. 12' SEE PLANS FOR - STALL DEPTH 11 T 1.5" SP-9.5 ASPHALTIC CONCRETE ............................................. ........... .................................. ...... ...................................... ....... ...................................... ............................................. .............................................. ..................................... 6" CRUSHED CONC. COMPACTED TO 98% OF THE MODIFIED PROCTOR (ASTM D-1557 AASHTO T-180), MAX. DENSITY, LBR 150 MIN., MEET FDOT SECTION 334 AND GRADATION REQUIREMENTS PER SECTION 911-3.4. 12" THICK FREE —DRAINING SAND SUB —BASE STABILIZED TO 98% OF THE MODIFIED PROCTOR (ASTM D-1557 AASHTO T-180), MIN. DENSITY. STABILIZING MATERIAL, IF USED, SHALL BE COARSE MATERIAL (e.g. GRAVEL). LOW PERMEABILITY (e.g.; SILT AND/OR CLAY) SHOULD NOT BE USED AS STABILIZING MATERIAL BENEATH CONCRETE PAVEMENT. NOTE: TYPE SP ASPHALTIC CONCRETE SHALL USE ASPHALT BINDER GRADE PG67-22 AND NO MORE THAN 15 PERCENT RECYCLED ASPHALT PAVEMENT (RAP) AGGREGATE. LIGHT DUTY ASPHALT PAVEMENT SECTION N.T.S. 3000 PSI CONCRETE 3/8 REBAR 12" OC EW (OR 6" x 6" 10 x 10 WIREMESH) 6" 12" SUBBASE COMPACTED TO 98% OF THE MODIFIED PROCTOR (ASTM D-1557, AASHTO NOTES: T180), WITH MINIMUM LBR VALUE OF 40. PROVIDE 18" OF CLEAN, FREE DRAINING SUBGRADE BENEATH CONCRETE PAVEMENT. COMPACT BOTTOM 6" TO 98% OF THE MODIFIED PROCTOR (ASTM D-1557, AASHTO T-180). DUMPSTER PAD SECTION d N.T.S. WALK WIDTH VARIES (SEE PLAN) 4" CONCRETE SLOPE PER PLAN 4"X 4"-4X 4 W.W.M. 6" COMPACTED SUBGRADE 98% AASHTO T-180 EXPANSION JOINT CONTRACTION JOINT 1" WATERPROOF ELASTIC CAULK 1/2" ELASTIMETRIC EXPANSION JT. MATERIAL 1/2 4" CONCRETE HAND TOOLED OR FORMED DEPTH = d"/4 SEE PLANS FOR SIGNAGE TYPES AND LOCATIONS to to I C:):Zi I M 'C-4 C-4 MIN. CONC. BASE TOP OF SIGN TO MATCH TOP OF POST. STOP 0 0 0 GALV - ------- SIGN POST 0 SIDE VIEW 0 SIGNAGE TO CONFORM TO FLORIDA 0 DEPARTMENT OF TRANSPORTATION 0 AND MUTCD SPECIFICATIONS. 0 0 N.T.S. WALK WIDTH VARIES (SEE PLAN) W VVfflFMV1LU 'JV0VnMVL UVIO . . . ... .. .. AASHTO T-180 6" TYPICAL THICKENED EDGE RAISED CONCRETE WALK ADJACENT TO PAVEMENT WALK WIDTH VARIES (SEE PLAN) SLOPE PER PLAN ASPH. PVM'T. 4"x4"-44w.w.m. z 6" COMPACTED SUBGRADE 98% AASHTO T-180 6' TYPICAL THICKENED EDGE FLUSH CONCRETE WALK ADJACENT TO PAVEMENT NOTES: 1. SIDEWALK W/LIGHT BROOM FINISH & TROWELED EDGE. 2. FOR APPLICATIONS WHERE SIDEWALKS ARE ADJACENT TO GRASSED AREAS, THE GRASS AREA SHALL NOT EXCEED A 3% SLOPE FOR A MINIMUM OF 5 FEET. 3. CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 PSI CONCRETE AT 28 DAYS 4. ALL CONCRETE SIDEWALKS SHALL HAVE A FULL 1/2" EXPANSION JOINT AT A MAXIMUM DISTANCE OF 40 LINEAR FEET AND A SAW CUT OR FORMED DUMMY CONTRACTION JOINT AT EVENLY SPACED INTERVALS NOT TO EXCEED WIDTH OF THE WALK OR 8 LINEAR FEET WHICH EVER IS THE SMALLEST. 5. AN CONSTRUCTION JOINT SHALL BE CONSTRUCTED AT ALL P.C. AND P.T. OF CURVES AND WHERE EXISTING AND NEW SIDEWALKS MEET. 0 UD z W z z > 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Selby G. Weeks 56991 revision description date Al AGENCY COMMENTS 03-16.23 SJRWMD PAC 04.21.23 A3 CITY COMMENTS o6.26.23 CITY COMMENTS 07.27.23 A drawn by: JD checked by: SGW date: o8/05/2022 plot scale: AS SHOWN project number: N/A file name:C600-DTLS-WEST-21TSGDool.DWG N.T.S Rename C600—DTLS—WEST-21TSGD001.dwg Plot Date Aug. 01, 2023 9:54am 4" CONCRETE WALK DETAILS N.T.S. Page 550 of 593 SLOTTED PVC CONNECTOR PIPE (METAL COLLAR REINFORCED) - of Fri 5" 16VINYL SHEATHED EAW STEEL CABLE (9800 LBS. GALVANIZED CO NKECTORSR(TOOL )F EEH DISCONNECT) CLOSED CELL SOLID PLASTIC FOAM FLOTATION (8" DIA. EQUIV.) (17 LBS. PER FT. BUOYANCY) CLOSED CELL SOLID PLASTIC FOAM FLOTATION (6" DIA. EQUIV.) (12 LBS. PER FT. BUOYANCY) -� 81POLYPRO ROPE 18 OZ. NYLON REINFORCED STR BREAKI G PVC FABRIC (300 PSI STRENGG TH) STRESS PLATE 5" --1sGALVANIZED CHAIN TEST) WITH LACING GROMMET 4"GALVANIZED CHAIN TYPE II D, =5' STD. (SINGLE PANEL FOR DEPTHS 5' OR LESS). TYPE D2 =5' STD. (ADDITIONAL PANEL FOR DEPTHS > 5'). CURTAIN TO REACH BOTTOM UP TO DEPTHS OF 10 FEET. TWO(2) PANELS TO BE USED FOR DEPTHS GREATER THAN 10 FEET UNLESS SPECIAL DEPTH CURTAINS SPECIFICALLY CALLED FOR IN THE PLANS OR AS DETERMINED BY THE ENGINEER. NOTICE: COMPONENTS OF TYPES I AND II MAY BE SIMILAR OR IDENTICAL TO PROPRIETARY DESIGNS. ANY INFRINGEMENT ON THE PROPRIETARY RIGHTS OF THE DESIGNER SHALL BE THE SOLE RESPONSIBILITY OF THE USER. SUBSTITUTIONS FOR TYPES I AND 11 SHALL BE AS APPROVED BY THE ENGINEER. FLOATING TURBIDITY BARRIERS o _ PROPOSED TOE OF SLOPE Q O R- O R- EXISTIN ~ �r CAUSEWA � SHORE LINE 0' 10 100, .c � I TYP�CPL CURRENT STRUCTURE ALIGNMENT 6' MAX. LEGEND • PILE LOCATIONS ® DREDGE OR FILL AREA -� MOORING BUOY W/ANCHOR —i ANCHOR O BARRIER MOVEMENT DUE TO CURRENT ACTION NOTES: 1. TURBIDITY BARRIERS ARE TO BE USED IN ALL PERMANENT BODIES OF WATER REGARDLESS OF WATER DEPTH. 2. NUMBER AND SPACING OF ANCHORS DEPENDENT ON CURRENT VELOCITIES. 3. DEPLOYMENT OF BARRIER AROUND PILE LOCATIONS MAY VARY TO ACCOMMODATE CONSTRUCTION OPERATIONS. 4. NAVIGATION MAY REQUIRE SEGMENTING BARRIER DURING CONSTRUCTION OPERATIONS. 5. FOR ADDITIONAL INFORMATION SEE SECTION 104 OF THE FDOT STANDARD SPECIFICATIONS. TURBIDITY BARRIER APPLICATIONS N.T.S. m MITS OF CONST. HORE LINE NOTE: TURBIDITY BARRIERS FOR FLOWING STREAMS AND TIDAL CREEKS MAY BE EITHER FLOATING, OR STAKED TYPES OR ANY COMBINATIONS OF TYPES THAT WILL SUIT SITE CONDITIONS AND MEET EROSION CONTROL AND WATER QUALITY REQUIREMENTS. THE BARRIER TYPE(S) WILL BE AT THE CONTRACTORS OPTION UNLESS OTHERWISE SPECIFIED IN THE PLANS. POSTS IN STAKED TURBIDITY BARRIERS TO BE INSTALLED IN VERTICAL POSITION UNLESS OTHERWISE DIRECTED BY THE ENGINEER. no sAWCUT 2'-0" REMOVE AND REPLACE EXISTING ASPHALT l'-0" REMOVE AND REPLACE EXIST. EXISTING ASPHALT EXISTING BASE EXISTING SUBBASE SAWCUT DETAIL N.T.S ASPHALTIC CONCRETE — BASE SUBBASE POST (OPTIONS: 2" X 4" OR 21" MIN. DIA. WOOD; STEEL 1.33 LBS/FT. MIN.) 18 OZ. NYLON REINFORCED PVC FABRIC (300 PSI TEST) LATH dt FLA ING �fIN ON ALL SIDES E 0 E El BERM 17 GA A El fD MIL Ej � PLASnG LINING SANDBAG NOT TO SCALE ffI h4tt PLASTIC LINING —BERW — PLYINDOO NOT 70 SCALE BLACK LETTERS 6' HEICHT 46" X 24" fQ' hflN B -STACKED 2 f ROUGH WOOD FRAME STAKE 10 MIL PLASTIC LINING NOT TO TAE fD IIL PLASTIC EININC �(WOOD FRAME RELY FASTENED AROUND ENTIRE PERIMETER %TH T E 1 SCIU i f. ACTUAL LAYOUT DETERMINED IN FIELD, 2, THE CONCRETE WAS14OUT SIGN SHALL BE INSTALLED VATHW 30 FT. OF THE TEMPORARY CONCRETE WASHOUT FAGBIITY. f. DRIED CONCRETE WASTE SHALL BE CONCRETE WASHOUT tfflLD NOT BE PICKED UP AND DtSPOKD OF PROPERLY ALLOWED IN STREET OR TO REACH WHEN 75X OF CAPAOTY IS REACHED.. STORM WATER DRAINAGE SYSTEM OR CONMETE WAS �. HARDENED CONCRETE CAN �E SIN DETAIL PROPERLY RECYCLED AND REUSED WATERCOURSE. 4, CONCRETE WASHOUT AREA TO BE (OR EQUIVADI17) SITE OR HAULED -SITE TO AN APPROPRIATE F"Aa TY. LOCATED AT LEAST 10' BEHIND CURB IF ADJACENT TO A PAVED ROAD. CONCRETE WASHOUT N.T.S. 4' TYP. TREE PROTECTION BARRIER DETAIL N.T.S. 2X4 RAILING, TYP. 2X4 POST, TYP. Cnz - -- -�? ac <L)z c� 95 z z > 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Selby G. Weeks 56991 evision Al 0 0 0 0 description date AGENCY COMMENTS 03.16.23 SJRWMD PAC 04.21.23 CITY COMMENTS o6.26.23 CITY COMMENTS 07.27.23 drawn by: JD checked by: SGW date: O$/05/2022 plot scale: AS SHOWN project number: N/A file name:C600-DTLS-WEST-21TSGDooi.DWG Filename : C600-DTLS-WEST-21TSGD001.dwg Plot Date : Aug. 01, 2023 9:55am Page 551 of 593 5' RIP RAP ENERGY DISSIPATOR N.T.S. CONCRETE FLUME LAP FABRIC 2' UNDER FLUME -' SECTION V,VVV 1 VI VVI\V. 1 LV »1{. (MONOLITHIC POUR) THE FILTER FABRIC SHALL BE TYPE D-2 AS SPECIFIED IN FDOT INDEX #199 CLASS 1 RIP RAP PER RIPRAP PLACEMENT AT MITERED END SECTION DETAIL, THIS SHEET •TONIOLAIN of I 515wRil, • RIPRAP APRON SHA LINED WITH FDOT D-2 GEOTEXTILE FABRIC �- VARI E RIPRAP SECTION VIEW A -A MT.8) POND BOTTOM (VARIES) CLEAN* ONSITE SAND BACKFILL (UNIFIED SOIL CLASSIFICATION SP OR SP-SM (WITH 7% MAX. FINES CONTENT) AND HAVING A MINIMUM PERMEABILITY OF KH OF 14.5 FT/DAY) ALL FILTER FABRIC JOINTS SHALL OVERLAP A MINIMUM OF 1 FOOT MIN. 3" GRAVEL ENVELOPE AROUND UNDERDRAIN PIPE, FDOT No.57 OR No. 89 GRAVEL (TYP.) 4" I.D. PERFORATED UNDERDRAIN PIPE WITH FILTER FABRIC SOCK FDOT SECTION 945 (TYP.). -UNDERDRAIN INVERT = 109.67 MIRAFI 1 OON OR EQUIVALENT GEOTEXTILE EXISTING CONTINUOUSLY WRAPPED AROUND SOILS 10" MIN. GRAVEL AND OVERLAP 1-FOOT MIN. NOTES: 1. PERFORATED UNDERDRAIN PIPE SHALL BE DOUBLED WALLED HDPE OR PVC. 2. UNDERDRAIN STONE SHALL NOT BE WATER SOLUBLE STONE (LIMESTONE). WASHED CONCRETE OR GRANITE SHALL MEET FDOT STONE SIZE DISTRIBUTION SPECIFIED IN SECTION ABOVE. *THE TERM "CLEAN" REFERS TO NON -EXPANSIVE CLEAN EARTH AND GRANULAR MATERIALS, FREE OF ROOTS OR ORGANIC MATERIALS (MUCK). USE OF ROCKS OR LUMPS LARGER THAN 3 INCHES IN ANY DIMENSION IS PROHIBITED UNDERDRAIN DETAIL - 2'-0" SKIMMER BLADE NON -TRAFFIC BEARING GRATE /611 6%12%12" CONCRETE COLLAR IN UNPAVED AREAS (TYP.) SKIMMER TOP ELEV.=116.60 MODIFIED TYPE "C" INLET, STRUCTURE TOP - FDOT INDEX No. 425-052 ELEV.=116.10 Ir 2' WEIR ELEV.=114.11 SKIMMER BOTTOM ELEV.=113.60 -.- FROM UNDERDRAIN -.- TO OUTFACE (6" PVC) (18" RCP) i INV. 109.58 N.T.S. 20.0' 4' BLACK VINYL CHAIN LINK FENCE. TOP OF HEADWALL=115.50 FLEXAMAT PER PLAN AN[ H LEGEND, SHEET C400 A 108.00f(MEG) 118.38- 3± 2" HDPE DR-11 (DIP OD WATER MAIN (PRIVATE IRIPRAP 8PMF10ATKX0 L/3 CLASS 1: D MAX = 12 INCHES D 50 = 8 INCHES D MIN = 4 INCHES CLASS 2: D MAX = 24 INCHES D 50 = 15 INCHES D MIN = 9 INCHES 3D RIPRAP SHALL CONSIST OF BROKEN STONE OR BROKEN CONCRETE WITH A BULK SPECIFIC GRAVITY OF AT LEAST 1.90. STONES OR BROKEN CONCRETE SHALL BE ROUGH AND ANGULAR. RIP RAP SHALL BE SOUND, HARD, DURABLE, FREE OF OPEN OR INCIPIENT CRACKS, SOFT SEAMS, OR OTHER STRUCTURAL DEFECTS. BROKEN CONCRETE SHALL BE CLEAN WITH NO REBAR OR OTHER L/3 FOREIGN MATERIALS. D MAX - NO RIPRAP SHALL EXCEED D MAX D 50 - AT LEAST 50% OF MATERIAL BY WEIGHT SHALL EXCEED D 50 D MIN - AT LEAST 90% OF MATERIAL BY WEIGHT SHALL EXCEED D MIN. RIPRAP APRON DIMENSIONS AND ESTIMATED QUANTITIES INLET PIPE SIZE "D" (IN) LENGTH OF APRON "L" (FT) DEPTH OF APRON "H" (FT) ESTIMATED RIPRAP (CY) ESTIMATED GEOTEXTILE (SY) CLASS 24 9 1.5 4.5 16 1 30 13.5 2 12 30 1 INV. 108.37 NOTE: REFER TO PLAN SHEET FOR ACTUAL ORIENTATION OF OUTFALL PIPE. CONTROL STRUCTURE D-13 N.T.S. �z a 4 w 0 H 5.0' 2TO' PROPOSED PAVEMENT 118.42 118.47 118.53 118.42 TYPE "F" CURB AND- 0.03± 118.04 118.34 GUTTER, BOTH SIDES 0,02± 0.02± 118.04 TYP. .�.�7777z, 5' CONCRETE „a 18"MI TYP,WALK 2.5" HDPE DR-11 FORCE MAIN 6'x4' BOX CULVERT - ROAD CROSS SECTION "B-B" N.T.S. 0.03± 0 FRAME & SOLID LID NEENAH N. R-1974-A OR APPROVED EQUAL, WITH CLEAR OPENING EQUAL TO PIPE I.D. - FINISHED GRADE PVC PIPE PVC WYE CLEANOUT DETAIL N.T.S. 3/16" FIBERGLASS REINFORCED THERMOSETTING RESIN SKIMMER BLADE. 1/2" X 1-1/2" S.S. TOP OF FIBERGLASS BOLT, WASHER & NUT SKIMMER w_ < > WEIR FABRICATE MOUNTING :::;/ BRACKET FROM 1/4" X 2" 4 **TACK WELD ALL FASTENERS S.S. OR ALUM. FLAT STOCK AFTER ASSEMBLY 1 /2" X 5" S.S. THREADED ROD WASHER SKIMMER MOUNTING BRACKET DETAIL Z N.T.S. a 1 w 0 1HI W 0 19, 20.0' 4' BLACK VINYL 118. 7 CHAIN LINK FENCE. 5+ 1 STOP OF HEADWALL=114.50 4" HDPE DR-11 (DIP OD) WATER MAIN KAMAT PER PLAN AN[ LEGEND, SHEET C400 107.92t(MEG) MATCH EXISTING GRADE/LIMITS 10 OF CONSTRUCTION TOP OF BERM: 117.25- VARIES 21.00' VARIES V4' BLACK VINYL 5.00' _ CHAIN LINK FENCE. UNDERDRAIN POND BERM TOP OF WALL: 117.50 TYPE 44E„ CURB 100YR/24HR PEAK STAGE: 116.63 N.T.S. TEMPORARY EROSION CONTROL/DOUBLE SIL FENCE LOCATED 1' BEHIND LIMITS OF CONSTRUCTI N .,, SURFACE WATER LIMITS WITHIN PROPERTY EXISTING DITCH TOP OF BANK/SURFACE WATER LIMITS w w ENCOUNTERED SC SOILS w LAYER, ELEVATION VARIES. 5' WIDE CLAY CORE. MINIMUM 20% FINES AND MAX. PERM 0.08 FT/DAY. MINIMUM 2FT BELOW „ THE EXISTING CLAYEY FINE SAND (SC) LAYER NOTE: PER THE GEOTECHNICAL REPORT, THE CLAYEY FINE SAND (SC) LAYER WAS ENCOUNTERED IN BORINGS AT AN APPROXIMATE DEPTH OF ELEVATION 112.00. HOWEVER, IF THE SC LAYER IS ENCOUNTERED DEEPER THAN ELEVATION 112m, THE CORE SHOULD BE EXTENDED AT LEAST 2 FT BELOW THE ENCOUNTERED SC LAYER, AS NOTED ABOVE. COT) w; w z `. t!3 z >, U 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Selby G. Weeks 56991 revision description date Al AGENCY COMMENTS 03.16.23 Q SJRWMD PAC 04.21.23 Q3 CITY COMMENTS o6.26.23 A CITY COMMENTS 07.27.23 0 0 drawn by: JD checked by: SGW date: 0$/05/2022 plot scale: AS SHOWN project number: N/A file name:C600-DTLS-WEST-21TSGDoo1.DWG Filename : C600-DTLS-WEST-21TSGD001.dwg Plot Date : Aug. 01, 2023 9:55am Page 552 of 593 Croy.,., unirr min.; *a See Note 3 NOTES: 1. Pipe bedding material and trench backfill shall be select common (clean) fill compacted to 95% (98% in roadway) of the maximum density as per AASHTO T-180. 2. Contractor shall install crushed rock (or equivalent bedding material) where pipe bedding does not provide solid support (yielding or plastic). Depth of material shall be a minimum of 6", or as needed, to provide non -yielding support for the pipe. All unsuitable material shall be removed from pipe bedding unless special provisions are approved by the City. 3. Excavated trench width at pipe haunch shall be sufficient in size for haunch compaction, but shall be no greater than 15" on each side of pipe for pipes less than 24" in diameter (24" for pipes 24" in diameter or greater.) 4. Water shall not be permitted in trench line during construction. 5. Pipe line shall be installed with bell fitting facing upgrade. 6. Gravity sewer shall have a 6" minimum rock bed. CITY OF OCOEE DETAIL CONSTRUCTION DETAILS NO. UT001 Pipe Bedding and Trench DATE: September 2019 SCALE: N/A Early Warning Tracing Wire - Pipe Cross Section -- -- 1100 \� T 1(Illiiii���llllllli,., rillillolii�o�1111 Finished Grade r- Existing Grade 1" Maximum #10 THHN Tracing Wire 1" max. from Top of Pipe. i _L , _ ,' i Transverse Section NOTES: 1. All pipe shall include the installation of #10 THHN copper tracing wire capable of detection by cable locating equipment. 2. Tracing wire shall be buried directly above the transverse centerline of the pipe. 3. End(s) of the locating wire shall be such that wire can be accessed by locating equipment assessing the wire in a valve vault or blow -off box. Wire is required to extend 12" minimum above finished grade. 4. Unless approved by the City, early warning tape indicating the type of pipe shall be required. 5. All directional drill pipe shall have locating wire attached to the top of pipe and shall remain on the top of the pipe during installation. 6. All service lines shall have locating wire placed on the pipe as described in City of Ocoee detail UT206 "Utility Service Connection" 7. All wire splices shall be completed with twist -on type wire nuts with gel or grease filled moisture seal. 8. All tracing wire installation shall be tested and verified for continuity by the contractor prior to final acceptance DETAIL NO. UT010 DATE: April20191 CITY OF OCOEE CONSTRUCTION DETAILS Pipe Locating Wire SCALE: NIA PVC/HDPE Restraint Table Minimum Length (FT) to be Restrained on each side of Fitting(s) Fittings Pipe Size 4" 6" 8" 101, 12" 16" 20" 90' Bend 18 24 32 38 44 55 74 45' Bend 10 10 13 16 18 23 31 22 1 /2' Bend 10 10 10 10 10 11 15 11 1 /4' Bend 10 10 10 10 10 10 10 Plug or Branch of Tee 30 47 64 81 98 133 167 NOTES: 1. The restraint values as indicated by the "Restraint Table" are minimum values. Design engineer shall be responsible for confirming field conditions, and make adjustments accordingly. 2. All fittings shall have restrained joints unless otherwise indicated. 3. No restraints required if continuous pipe length to fitting is greater than value provided in "Restraint Table" above. 4. Where two or more fittings are laid in -line, use greatest restraint length for coverage. 5. For in -line valves and through run of tees: outside limits of restrained joints from other fittings need not be restrained unless otherwise indicated. 6. Lengths shown in the table have been calculated in accordance with the procedures outlined in "Thrust Restraint Design for Ductile Iron Pipe" as published by DIPRA, with the following assumptions: Working Pressure: 150 PSI Soil Designation: SM (Silty Sand, Sand -Silt Mix.) Laying Conditions: 5 7. For pipe sizes not included in the Restraint Table or pipe material not adhering to given conditions, design engineer shall determine and specify pipe lengths which shall be approved by the City. DETAIL NO. UT004 DATE: April2019 i ►• CITY OF OCOEE CONSTRUCTION DETAILS PVC/HDPE Pipe Restraint Table SCALE: N/A o- 11011 T 1111,1,1,.: ,III�����oi11111 Pipe/Main color based on use. Main (type) Main (type) See Note 2 for lettering size and orientation. 1. Lettering shall be per the American Water Works Association. 2. Lettering shall be a minimum of 3/4" in height and shall be be facing up when the pipe is installed. 3. Lettering must be permanently imbedded into the pipe/main, not painted or stenciled. 4. Lettering shall be of contrasting color to pipe/main color. Pipe Markina (Letterin Main (type) Main (type) Main (type) Diameter = 2.5" to 4" 3" Tape centered along the top half of pipe. (adAl) qeW (adAl) qeW (adAl) uien Main (type) Main (type) Main (type) Diameter = 6" to 16" Two (2) 6" Tapes along both sides of top half of pipe. (adAl) uien (adAl) qeW (adAl) uien Main (type) Main (type) Main (type) Main (type) Main (type) Main (type) Diameter = 20" and larger Three (3) 6" Tapes along top and both sides of top half of pipe. Warning Tape N.T.S. WARNING TAPE NOTES: 1. Tape color shall be in accordance with (same) as main/pipe color. 2. Tape lettering shall be at least 1" in height with no greater than 12" in spacing. 3. Warning tape shall extend total length of pipe. DETAIL CITY OF OCOEE / NO. CONSTRUCTION DETAILS __ __\ ���' r 9" Pipe Identification UT011 p i �� Warning TapeI-T_ ��\\\�" DATE: April2019 SCALE: NIA See Note 8: �Y o� oCo C` R p,1 F # TURNS Valve I.D. Marker (See note 6) Finished Grade Actuating Nut for Valve Adjustment Ring Valve Pipe/Main a #4 bar with 2" mi concrete cover Z ( OF OCO E R M,q / FF �� URNS cCW OPEN 24" Concrete Collar (See note 5) Adjustable cast iron valve box Valve box shall rest on bedding rock, not on valve or pipe, and shall be centered on operating nut. 6" FDOT #57 Stone--�- r NOTES: 1. PVC extensions shall not be used on valve box. 2. The actuating nut for valves shall be no deeper than 24" from ultimate finished grade. 3. Valve assembly shall include center spacing guide from the City's Approved Materials List. 4. Where valve nut is more than 36" below grade, valve assembly shall include an extension from the City's Approved Materials List. 5. Valve collar shall be 24" x 24" x 6" square pad and concrete for collar shall be fc' of 3,000 psi minimum @ 28 days for non -pavement areas. 6. Valve Marker shall be from the City's Approved Materials List and shall include "City of Ocoee", main type, size, material, turns to open or close valve, and direction of rotation. 7. Valve Box shall not be located in pavement, sidewalk, or driveway unless approved by the City. If approved, Contractor/Developer shall reach out to the Utilities Department on the location of the Valve Tags. 8. For Valve Box approved in pavement, a disk valve marker shall hang in the valve box anchored to the locating wire. CITY OF OCOEE j =_= DETAIL CONSTRUCTION DETAILS r \ \� UT009 Valve Box and Cover 1�� \ DATE: June 2021 SCALE: N/A li 1(Illiiii���llllll,.. ►111��ii��111111 Drill hole in - Box (below and above box thread: Provide on. tracing wirE and coil ex, valve box �r�>rrma. NOTES: 1. All pipe shall be installed with # 10 THHN solid copper tracing wire. Tracing wire must be installed directly above the pipe in a continuous circuit. 2. Tracing wire shall cover all main, pipe, branches (including fire hydrants) and service connections. 3. Tracing wire shall extend a minimum of 12" above grade at required intervals and/or valve lids. 4. Tracing wire shall be coiled and placed in a valve box and shall be easily accessible. 5. At dead ends of mains, pipe, and/or service, the tracing wire shall be placed in a properly identified cast iron valve box (Valve Box and Cover Detail UT009). DETAIL NO. UT012 DATE: April2019 CITY OF OCOEE CONSTRUCTION DETAILS Tracing Wire Location SCALE: NIA gpp 1\10EN �` \ i(1(Illii��ii�llllilli �' - ' rrililli��ii�0111111 CnZ Lu w z 0 Z t:� w c.i 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Selby G. Weeks 56991 N revision Al A A A 0 description date AGENCY COMMENTS 03.16.23 SJRWMD PAC 04.21.23 CITY COMMENTS 06.26.23 CITY COMMENTS 07.27.23 drawn by: JD checked by: SGW date: O8/05/2022 plot scale: AS SHOWN project number: N/A file name:C600-DTLS-WEST-21TSGDoo1.DWG Filename : C6D0-DTLS-WEST-21TSGD001.dwg Plot Date : Aug. 01, 2023 9:56am Page 553 of 593 Vented ARV enclosure (See note 6) RIGHT OF WAY PRIVATE PROPERTY D.I.P. Restraint Table 2" Air release valve Minimum Length (FT) to be Restrained 2" TEE with on Each Side of Fitting(s) removable Cap Pipe Size 2" Ball/Plug valve Fittings 1' Min. 4" 6" 8" 10" 12" 16" Public Private Adjustable cast iron 90° Bend 15 21 27 32 37 47 valve box CityWater Meter with Meter Kit g g p (Detail UT009) 9" (Shall be purchased from the Flanged Fitting Backflow reventer 45° Bend 7 5 11 13 16 20 18" Min. City) [see note 1] in. � Gate Valve 22 1/2° Bend 5 5 6 7 8 10 / / / - l - - r. / �� / /� Flanged Curb Stop \ \ Finished Grade 2" Pi X 11 1/4° Bend 5 5 5 5 5 6 Plug or 30 47 64 81 98 133 2:(TYp•) Pipe 9" Min. �� Branch of Tee 2 Corp stop N N to . Min. 3% 2" Elbow slope FDOT #57 stone NOTES: 1. The restraint values as indicated by the "Restraint Table" are minimum values.Design engineer shall be responsible for confirming field conditions, and make adjustments accordingly. 2. All fittings shall have restrained joints unless otherwise indicated. 3. No restraints required if continuous pipe length is greater than value provided in "Restraint Table" above. 4. Where two or more fittings are laid in -line, use greatest restraint length for coverage. 5. For in -line valves and through run of tees: outside limits of restrained joints from other fittings need not be restrained unless otherwise indicated. 6. Lengths shown in the table have been calculated in accordance with the procedures outlined in "Thrust Restraint Design for Ductile Iron Pipe" as published by DIPRA, with the following assumptions: Working Pressure: 150 PSI Soil Designation: SM (Silty Sand, Sand -Silt Mix.) Laying Conditions: 5 7. For pipe encased in polyethylene, use values given in parentheses or increase the given value by 150%. 8. For pipe sizes not included in the Restraint Table or pipe material not adhering to given conditions, design engineer shall determine and specify pipe lengths which shall be approved by the City. DETAIL NO. UT005 DATE: April2019 Drill hole in Box (below and above box thread: Provide on, tracing wire and coil ex valve box fi�i[�;rli.1.1► CITY OF OCOEE CONSTRUCTION DETAILS Ductile Iron Pipe Restraint Table SCALE: N/A NOTES: 1. All pipe shall be installed with # 10 THHN solid copper tracing wire. Tracing wire must be installed directly above the pipe in a continuous circuit. 2. Tracing wire shall cover all main, pipe, branches (including fire hydrants) and service connections. 3. Tracing wire shall extend a minimum of 12" above grade at required intervals and/or valve lids. 4. Tracing wire shall be coiled and placed in a valve box and shall be easily accessible. 5. At dead ends of mains, pipe, and/or service, the tracing wire shall be placed in a properly identified cast iron valve box (Valve Box and Cover Detail UT009). DETAIL NO. UT012 DATE: April2019 CITY OF OCOEE CONSTRUCTION DETAILS Tracing Wire Location SCALE: NIA /, ^\"'e pw 6" Min. 2" Plug valve with 2" square nut Double strap stainless steel saddle Varies (See Note 1) 2" Elbow and tubing (threaded) Main Diameter ARV 12" and smaller 2" 16" 3" 20", 24" 4" 30", 36" 6" NOTES: 1. Gas Release Valve shall mean Air, Combination Air/Vacuum, and Surge Protection Release Valve. 2. Offset distance to be field determined and as close to the right of way as possible and clear of pedestrian walkways. If pipe is at right of way line, no offset is required. 3. Above detail applies to a 2" ARV. For larger ARVs, pipe diameter and valves shall be equal to the size of the ARV. 4. All piping, valves and appurtenances to be brass or 316 Stainless Steel except where specified otherwise. 5. ARV shall have a Reinforced Nylon Body D-040 or Ductile Iron Body D-060 for Potable Water Systems. ARV shall be Reinforced Nylon Body D-021 or Ductile Iron Body D-060 for Reclaim Water Systems. 6. The enclosure shall follow the City's Approved Materials List or be an approved equal with temper proof locking device and vents must be capable of allowing at least the same amount of airflow as the valve. 7. Shop drawings for the ARV shall be submitted to the City for approval. 8. Any deviation from this detail shall be made known to the City for approval. DETAIL NO. UT204a DATE: June 2021 CITY OF OCOEE CONSTRUCTION DETAILS Gas Release Valve Water and Reclaim SCALE: N/A - ft \��Vo Pipes/Mains Separation Requirement Table (See Note 11 for Structural) Potable Reclaimed Sanitary Sewer Storm Sewer Structural Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Vert. Horiz. Potable 3' 12" 10, 18" 3' 18" 10, Reclaimed 3' 12" 3' 12" 3' 12" 10, Sanitary Sewer 10, 18" 3' 12" 3' 12" 10, Storm Sewer 3' 18" 3' 12" T 12" Z Z 10, Joint Spacing Requirement Table (See Note 2) Potable Reclaimed Sanitary Sewer Storm Sewer Potable 3' 6' 3' NOTES: 1. The table above represents the minimum separation requirements as described in the City's Engineering Standards Manual. The most stringent requirements between the City's Standards and the guidelines set forth in the Florida Administrative Code 62-555.314 (F.A.C). shall apply between newly proposed utility lines and existing or proposed utility lines. 2. Joint spacing shall be based on one full length water main pipe centered above or below other pipes. The joint shall be no less than the required distance from the center of the crossing of the two pipes. (The water pipe shall be above the other pipe unless otherwise approved by the City.) 3. Where the City's minimum vertical and horizontal separation from potable water cannot be achieved from the outside of the potable water pipe and the outside of the other pipe/main, preferred separation in accordance with F.D.E.P. rules of the Florida Administrative Code 62-555.314 (F.A.C.) and 62-604.400 (F.A.C.) may be allowed upon approval by the City's Utilities Department. a. If it is not technically feasible or economically sensible to comply with the requirements set forth in 62-555.314 (F.A.C.), technical or economic justification for each exception must be submitted to F.D.E.P. with alternative construction features. Proof of F.D.E.P.'s approval for exceptions shall be submitted to the City. 4. For the purpose of this table, reclaimed water shall mean unrestricted public access reuse water as defined by F.A.C. 62-610. Other types of reclaimed water, not treated to public contact levels, shall be considered raw sewage, and the separation list for sanitary sewer shall apply. 5. Alternative water, such as storm water used for irrigation, shall be considered reclaimed water for separation requirements. 6. Pipe separation distance provided above shall mean the horizontal and/or vertical distance measured for the outside dimension of each pipe/main. 7. All Sanitary and Storm Structures shall follow separation requirements above. 8. Potable water pipes shall be laid above all pipes conveying raw sewage whenever they cross. 9. All utilities shall be installed with 36" of cover over the top of pipe. Cover shall be measured with current or future grading to ensure the 36" coverage. 10. No potable water pipe may pass through a sanitary sewer structure. Penetration through storm sewer must be approved by the City and is subject to special conditions and materials. 11. Structural shall refer to foundations, walls, etc. Additional separation shall be required by the City for construction of, including, but not limited to: live loads, multi -story commercial buildings, superstructures, embankments, retaining walls, bridges, railroads, high voltage transmission mains, gas mains, etc. CITY OF OCOEE DETAIL CONSTRUCTION DETAILS NO. UT013 Pipe Separation Requirement Table DATE: November 2022 SCALE: N/A From Resilient Seat Square Nut 18" Wide x 6" To Main Gate Valve Concrete slab with Structure (For Valve Box and Cover #4 Bar all around see Ocoee Detail UT009) (2 Required) NOTES: 1. Contractor shall be responsible for installing City water meter matching pipe size with meter kit and shall supply and install all materials and Backflow prevention device. 2. Backflow device shall be per the City's Cross Connection Control Manual. 3. All pipes, fittings, and end valves as indicated as private shall be the responsibility of the owner. All pipes and fittings indicated as public with material not indicated shall be brass or schedule 80 PVC. CITY OF OCOEE DETAIL CONSTRUCTION DETAILS NO. UT209b 1 1/2" and Larger Commercial/Multi-Family Meter Configuration DATE: June 2021 SCALE: N/A Lot Line Clean -out (See Note 1) m c E Private To Home NOTES: Varies Wye With Branch 450 Bender Varies Sewer Main Size Varies Double Wye-/ Plan View Finished Grade Slope To Terminal Deptl At 1.0% Minimum (Typ.) Rotate 300 (Typ.) Spring Line (See Note 3) Sewer Main Single Lateral Double Lateral Right of Way Section View Property Line Private To Home 1. Clean -out (shown hatched) shall be installed by the builder in accordance with standard plumbing code. 2. Locate clean -outs as close to the property line as possible. 3. Invert of service lateral shall not enter sewer main below spring line. 4. The minimum terminal depth as required for house service is 3'. 5. Service Laterals shall be a minimum of 6" for non-residential scenarios. In residential areas, service laterals shall be a minimum of 4" to the right-of-way and then 6" to the sewer main. DETAIL NO. UT105 DATE: April20,19 CITY OF OCOEE CONSTRUCTION DETAILS Service Lateral SCALE: NIA CnZ Lu w z t2 Z W J 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Selby G. Weeks 56991 N revision description date Al AGENCY COMMENTS 03.16.23 0 SJRWMD PAC 04.21.23 A CITY COMMENTS 06.26.23 ® CITY COMMENTS 07.27.23 0 drawn by: JD checked by: SGW date: O8/05/2022 plot scale: AS SHOWN project number: N/A file name:C600-DTLS-WEST-21TSGDoo1.DWG Filename : C6D0-DTLS-WEST-21TSGD001.dwg Plot Date : Aug. 01, 2023 9:56am Page 554 of 593 T 6" Min. 2" Plug valve with 2" square nut " Double strap stainless steel saddle Varies (See Note 1) 2" Elbow and tubing (threaded) Main Diameter ARV 12" and smaller 2" 16" 3" 20", 24" 4" 30", 36" 6" NOTES: 1. Gas Release Valve shall mean Air, Combination Air/Vacuum, and Surge Protection Release Valve. 2. Offset distance to be field determined and as close to the right of way as possible and clear of pedestrian walkways. If pipe is at right of way line, no offset is required. 3. Above detail applies to a 2" ARV. For larger ARVs, pipe diameter and valves shall be equal to the size of the ARV. 4. All piping, valves and appurtenances to be brass or 316 Stainless Steel except where specified otherwise. 5. ARV shall have a Reinforced Nylon Body (ARI D-025 or D-26). 6. The enclosure shall be Water Plus Polyethylene Model 131632 H-30-G or approved equal with temper proof locking device and vents must be capable of allowing at least the same amount of airflow as the valve. 7. Shop drawings for the ARV shall be submitted to the City for approval. 8. Any deviation from this detail shall be made known to the City for approval. DETAIL NO. UT106a CITY OF OCOEE CONSTRUCTION DETAILS Gas Release Valve Wastewater Finished Grade Tapped End Cap- 2" Brass Double Meter Box (traffic rated) 2" Brass Coupling Crushed stone 6" thick extending 2" beyond box 2" Blue Polyethylene Pipe Cross Section 1. All pipes and fittings shall be schedule 40 brass or equivalent with threaded (NPT) joints except where denoted otherwise. 2. All pipe and fittings shall be in accordance with City Standards for the applicable service provided. 3. Pipe restraints shall be in accordance with City Standard Details UT004 for PVC/HDPE Pipe or UT005 for Ductile Iron Pipe. CITY OF OCOEE DETAIL CONSTRUCTION DETAILS NO. UT203 Blow Off Assembly DATE: April2019 ( SCALE: NIA Brass Corporation Stop (1" Min.) #10 THHN Tracing U-Branch Brass FWire to Match Use (1" x 3/4" x 3/4") in Color Installed Upright Curb Stop Z (See Note 3) w d ?' Coil Excess Service Polyethylene Tracing Wire in Tubing Box Single Meter Box and Water Meter (By City) Service View with Single Meter AWWA Typ( CC Threads #10 THHN-\ Tracing Wire, Color to Match Service Water Main % --_ 4 X '10FIN T ((1(ll���ii�llllliil��'' - 'all►iilil0�o�11111 igled Stops at of Horn L-Double Meter Box and Water Meter (By City) Double Meter Configuration Corporation Stop (Ford F1000-4NL) & Fittings (normally open) To Meter/Box Assembl 30°to 45' \-Service, Polyethylene iTubing, 1" min. -Double Strap Stainless Steel Saddle Tapping Section NOTES: 1. All fittings shall be brass with compression -pack joint type connections. 2. No service line shall extend or terminate under a driveway. 3. Meter end of service shall terminate with curb stop (90°) for single service and dual horn and curb stops (90°)for dual services. 4. Meter end of service shall terminate 3' past meter location where service shall, unless directed otherwise, extend 3' above finished grade tied to a 2" x 4" x 4' stake. If directed, service connection shall be buried and located with an 2" x 4" x 4' painted marker. Stake or marker shall indicate lot(s) to be served. 5. Concrete curb shall be marked (stamped or saw -cut) with "W" locating service. 6. Service connection to the main shall use approved saddle, and tapping of main shall be by a method where a solid coupon is removed. 7. Services installed under finished or existing pavement shall be directionally drilled. 8. Upon approval, direct tap (no saddle) may be used on Ductile Iron Pipe. 9. Service color shall be blue for potable water and purple (magenta) for reclaimed water. CITY OF OCOEE DETAIL NO. CONSTRUCTION DETAILS UT206 Water and Reclaim Service Connection DATE: Sep.2019 SCALE: N/A Restraining DIP Fitting ---K HDPE MJ Fitting. Welded to HDPE Main HDPE Pipe or Spool Piece (See Note 3) Stainless Steel Pipe Gap Separation Main Stiffener HDPE Pipe J (See Note 6) (See Note 5) Section View NOTES: 1. The detail shall be used when connecting directional drilled sections of mains together using valves, sleeves, fittings or appurtenances. 2. This detail is limited to the use of 4" to 12" mains. 3. In cases where directional drill main must be offset by direct bury of a portion of the main, contractor may elect to use a Restrained End for both connections. 4. A stainless steel stiffener is required on Restrained End of connection when HDPE is used. 5. Spool piece for fittings or around main offsets may use alternative approved main material. Payment (if applicable) for the alternative material main shall be paid under the replaced main pay item. 6. Gap between mains when connecting with a sleeve shall be no greater than 2.5". 7. The information and requirements in this detail are for directional drill connections only. For other connections refer to other City details. CITY OF OCOEE DETAIL CONSTRUCTION DETAILS NO. UT014 Direction Drill HDPE Connection DATE: April2019 SCALE: N/A Hydrant Operating Nut Hose Nozzle Maximum 6" Clearance Between Concrete and Bottom of Nuts/Bolt -v T ((1(ll���ii�llllliil��'' - 'algp l►iilil0�o�11111P11011 I 3'to 5' I Pumper Nozzle Facing Street f 18" Min. Above o Finished Grade Sidewalk LExpansion Fiber 24" Material (TYP) Compacted Backfill Concrete MJ Hydrant Anchoring Tee Resilient Seat Gate 6" Bedding Rock Valve and Box (See Detail UT009) Edge of Pavement Edge of Pavement Standard Configuration Alternate Configuration Note: 1. Hydrants shall be painted with double coat enamel paint per the following: • Public Potable Water - Safety Yellow Pantone 13-063OTN • Reclaimed Water - Purple Pantone 522 C • Private Fire- Cherry Red HDC-MD-16 2. Concrete shear pad shall abut between sidewalk and curb. Where sidewalk is not present, concrete shear pad shall be approx. 7.5' x 3.5' min. 3. Concrete shall be 6" thick with fibermesh and shall be fc' of 3,000 psi minimum at 28 days. 4. Any deviation from this detail shall be made known to the City for approval. DETAIL NO. UT201 DATE: June 2021 CITY OF OCOEE CONSTRUCTION DETAILS Fire Hydrant Assembly SCALE: n/a CnZ U w z t2 Z uw J c.i 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Selby G. Weeks 56991 N revision description date Qi AGENCY COMMENTS 03.16.23 0 SJRWMD PAC 04.21.23 A CITY COMMENTS o6.26.23 ® CITY COMMENTS 07.27.23 A drawn by: JD checked by: SGW date: o8/05/2022 plot scale: AS SHOWN project number: N/A file name:C600-DTLS-WEST-21TSGDoo1.DWG Filename : C6D0-DTLS-WEST-21TSGD001.dwg Plot Date : Aug. 01, 2023 9:57am Page 555 of 593 SCOPE: Supply one complete H-20 GP Pre -Fab Lift Station, per design. Pumps shall be capable of grinding and pumping domestic & commercial sewage. Complete system shall be supplied by: RIL O O Company, Inc, Sanford, 6h TOO Rho 40-265 00) NO SUBSTITUTIONS O 4[00R4 FS NO I f .�Ay �Koj J1=- - i U1W The H-20 Load Rated Fiberglass Wetwell Must Be Manufactured By L.F. Manufacturing, Giddings, Texas, Which Includes A Written 20 Yr. Warranty Certification of the wetwell H-20 load rating must be supplied with submittals. H-20 certification must be signed and sealed by an engineer registered in the State of Florida. After the H-20 load rated wetwell has been installed, the ASTM Certification Number and Serial Tracking Number must be visible. i Submersible grinder pumps shall be RILEY Model RC30061. installed in the H-20 GP FRP wetwell utilizing a dual slide rail system. The grinder unit shall be capable of macerating materials normally found in domestic and commercial sewage into a fine slurry which will pass through the pump and the Sch.80 PVC discharge piping. Stator winding shall be open type with Class F insulation and shall be heat - shrink fitted into the stator housing. The use of pins, bolts, or other fastening devices is not acceptable. A heat sensor thermostat shall be attached to the top end of the motor winding and shall be connected in series with the magnetic contactor coil in the control panel to stop motor if winding temperature exceeds 140 C., but shall automatically reset when the winding temperature returns to normal. Two heat sensor thermostats shall be used on three phase motors. The pump motor grinder shaft shall be AISI 430F SS threaded to take the pump impeller and the grinder impeller. Upper & lower mechanical seals shall be Silicon Carbide vs Silicon Carbide. aoi 0 CL C ig N I 0 i 0 N 0 a v c c y ,r 0 0 0 0 0 J N �i Filename : C600—DTLS—WEST-21TSGD001.dwg Plot Date : Aug. 01, 2023 9:57am I To insure complete unit and warranty responsibility the electrical control panel must be manufactured and built by the pump supplier. The pump supplier must be a TUV (UL508A CERTIFIED) manufacturing facility, with a minuimum of 5 years history in the manufacturing of electrical control panels. The Enclosure shall be NEMA 4X, minimum 30" high x 30" wide x 10" deep aluminum with 4 point latching system. The enclosure shall have external mounting feet to allow for wall mounting. The following components shall be mounted through the enclosure: 1- ea. Red Alarm Beacon (Light) 4" x 4" Minimum Diameter 1- ea. Alarm Horn (minimum 95 DCB) 1- ea. Generator Receptacle w/ weatherproof cover(SCM460 -UL 1686) 1- ea. Alarm Silence Pushbutton The back panel shall be fabricated from .125, 5052-H32 marine alloy aluminum. All components shall be mounted by machined stainless steel screws. The following components shall be mounted to back panel: 2- ea. Motor Contactors 1- ea. Volt Monitor (1 Ph) Phase Monitor (3 Ph) w/2 N/O & 1 N/C Contacts 1- ea. Control Transformer (480 Volt Only) (Min. 500VA) 1- ea. Silence Relay Module 1- ea. Duplex Alternator w/Pump Selector Switch 1- ea. Model RCBB5AH Battery Back -Up w/ Smart Charger 20- ea. Terminals For Field Connections 6- ea. Terminals For Motor Connections (Single Phase Only) 7- ea. Grounding Lugs 1- ea. Seal Failure Relay The inner door shall be fabricated from .080, 5052-H32 marine alloy aluminum. The inner door shall have a continuous aluminum piano hinge. The following components shalt be mounted through the inner door. 1- ea. Main Circuit Breaker 1- ea. Emergency Circuit Breaker 1- ea. Mechanical Interlock For Emergency And Main Breakers (UL Listed) 2- ea. Short Circuit Protectors w/Auxiliary Contacts 1- ea. Control Circuit Breaker 2- ea. Seal Failure Indicator Lights 1- ea. Hand -Off -Auto Selector Switches 2- ea. Pump Run Pilot Lights 1- ea. Power On Pilot Light 2- ea. Elapse Time Meters (Non-Resetable) 1- ea. GFI Duplex Convenience Outlet COMPONENT SPECIFICATIONS: All circuit breakers shall be molded thermal magnetic. The mechanical interlock shall prevent the normal and emergency main breakers being energized at the same time. An emergency generator receptacle shall be supplied in accordance with DEP standards. The generator receptacle shall be 100 AMP, 230 V to meet the equipment operating conditions. VEUTRAL TO BE SUPPLIED FOR BOTH 230V 3PHASE OI ?30V SINGLE PHASE POWER All motor short circuit protection devices must provide for under voltage release and class 10 overload protection on all three phases. Visible trip indication, test, and reset capability must be provided without opening inner door. Open frame, across the line, contactors shall be rated per IEC standards and properly sized per the motor requirements. Contactors shall provide for safe touch power and control terminals. Lightning Arrestor shall meet UL 1449 3rd Edition or exceed the requirements of ANSI/IEEE Std. C62.21-1984 section 8.6.1. and 8.7.3 shall be supplied by electrician and mounted on the bottom side of the switch disconnect ahead of the pump control panel. A voltage monitor shall be supplied for single phase service. A phase monitor shall be supplied for (3) phase service. A green pilot light shall be supplied for each motor. The pilot light shall illuminate each time the motor is called to run. Each pump shall have an Elapse Time Meter to record the accumulated run time. The ETM shall be 2" diameter, non-resettable, six digit, totally encapsulated unit. A Red pilot light shall be supplied for control power. The pilot light shall illuminate when the control power is available inside the control panel. Relays shall be ice -cube plug in type. Relay contacts shall be rated 10 amp minimum, DPDT. Twenty (20) terminals shall be supplied for field connections. The terminals shall be rated 25 amps minimum. Each motors over -temperature contact shall be connected to the terminal strip and shall open a contact to de -energize the appropriate motor upon a high temperature within the motor. A 15 Amp GFI duplex receptacle shall be supplied and mounted on the innerdoor. Ground lugs shall be supplied and appropriately sized for each motor and for service entrance. MISCELLANEOUS: All wiring on the back panel shall be contained within the wiring duct. All wiring between the inner door and the back panel shall be contained with in a plastic spiral wrap. Each wire shall have a wire number at each end to correspond to the as built drawing for field troubleshooting. The control panel must be manufactured in-house by lift station supplier and be a TUV (UL508A Certified) facility. FASTENERS & APPURTANCES: All fasteners, lifting cables, float cable bracket, hinges, and appurtenances shall be made of ANSI 304SS. A 304SS slide/latch assembly shall be provided for holding the doors open on the wetwell and valve box. Slide rails shall be made of SCH.40 AISI 304SS pipe. Pump lifting cables shall be made of AISI 304 SS. Pump lifting bales shall be made of AISI 304 SS. H-20 LOAD RATED WETWELL WITH LIFTING LUGS: The fiberglass wetwell must be H-20 load rated with integral lifting lugs, fiberglass slope in bottom of wetwell and valve box. Certification of the H-20 load rating must be supplied at the time of submittals to Engineer. The wetwell shall be manufactured of fiberglass reinforced polyester (FRP) of depth and diameter as shown on the lift station elevation detail. The wall thickness shall be adequate for the depth of the wetwell to maintain the H-20 LOAD RATING. EXECUTION: Installation shall be in strict accordance with the manufacturer's recommendations in the locations shown on the drawing. INSPECTION & TESTING: A factory representative shall be provide for a one (1) time start-up and shall have complete knowledge of the proper operation and maintenance of complete system. Megger the motors. The pump motors shall be megged out prior to the start-up to ensure that the insulation of the pump motor/cable is intact. The pump controls and pumps shall be checked for mechanical reliability and proper operation. S.S. HINGES O ►k1 RILEY & COMPANY 3" ACTIVATED CHARCOAL FILTER VENT 3- (2") FIELD INSTALLED KNOCKOU FOR ELECTRICAL CONDUITS INTEGRAL LIFTING LUGS COMPOSITE WATER -TIGHT INLET SLEEVE w/SS NUTS & BOLTS 6" INLET FIELD INSTALLED LIFT STATION WILL BE PRIVATELY OWNED AND MAINTAINED. PUMP DATA ELEVATIONS PRIMARY PUMP CAPACITY 81 GPM 00 TOP OF WETWELL 119.90 PRIMARY TDH 58' TDH INLET INVERT 115.28 PUMP MANUFACTURER L B E RT HIGH LEVEL ALARM (HLA) 115.28 PUMP MODEL # LGV034A 2nd PUMP ON (LAG) 114.28 R.P.M. 3,450 1st PUMP ON L( EAD) 113.28 HORSEPOWER 3 PUMPS OFF (OFF) 112.28 ELECTRICAL/ VOLTS / PHASE 480V/3 BOTTOM OF WETWELL 111.28 PUMP DISCHARGE SIZE 3" WETWELL DIAMETER 48" * ELECTRICIAN NOTES: 1. DRAWING NOT TO SCALE * 2. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES * 3. ELECTRICIAN SHALL SEAL OFF CONDUIT RUNS * 4. ELECTRICIAN TO MOUNT LIGHTNING ARRESTOR AT SWITCH DISCONNECT * 5. CONTRACTOR SHALL VERIFY POWER SOURCE PRIOR TO ORDERING EQUIPMENT * 6. NEUTRAL TO BE SUPPLIED FOR 230V-3 PHASE OR 230V-SINGLE PHASE POWER. RILEY & CO. / H-20 GP 09-29-16 O O ALUMINUM COVER FIBERGLASS VALVE BOX (LOCKABLE) w/ (LOCKABLE) ACCESS HATCH 3" EMERGENCY PUMP -OUT FIBERGLASS WETWELL w/ PLUG VALVE H-20 LOAD RATED 2.5" SS (0-100 PSI) PRESSURE GAUGE w/ 20 YR. WARRANTY Ow/ SHUT-OFF VALVE FLANGE f FLANGE CONNECTION ALUMINUM HATCH (LOCKABLE) FIBERGLASS VALVE BOX (40" x 36" x 36" DEEP) HDPE SDR11 BRACKET BRACKEETT 1 g PIPING & FITTINGS (HEAT FUSED) FLANGED CONNECTION 316SS 2" PVC DRAIN uFTING CHAIN "P-TRAP„ ( ) OFF �111111 A 0 INTEGRAL FIBERGLASS SLOPE- 6" r 6" a 12" ° CONCRETE BASE SLAB AS PER SPECIFICATIONS w/ #4 REBAR 18" O.C. SWITCH DISCONNECT CONTROLPANEL� (LOCKABLE) GENERATOR RECEPTOR MODEL UL 1686 SCM460 - GALVANIZED UNISTRUT 1" HOSE BIB 1" GALV. RISER 2" x 6" INTEGRAL FRP BOTTOM SUPPORTS ELECTRIC METER OR PULL POWER FROM BUILDING 2" CAPS LIGHTNING ARRESTOR FIELD MOUNTED BY ELECTRICIAN 2- SEAL -OFFS ( 2" ) BY ELECTRICIAN z PUMP POWER CABLES (2" CONDUITS) FLOAT SWITCHES (2" CONDUIT) SLEEVE REQUIRED r 2" RIGID ALUMINUM POSTS TO WATER SUPPLY 0 CONCRETE AROUND POSTS NOTE: GROUND ROD 12" DIA. x 24" DEER REDUCED PRESSURE (RPZ) BACKFLOW PREVENTER TO SERVICE LOCATION TO BE INSTALLED IN WATER SUPPLY LINE TO (VERIFY w/ POWER CO.) LIFT STATION "FEBCO WATTS" (OAE) ISOLATION PLUG VALVE FRP VALVE COVER 16" x 16" x 16" DEEP 9 1 1' Eel:7_10 CAST-IRON 3" F.M. PLUG VALVE INTEGRAL FIBERGLASS SLOPE L (3") CAST-IRON FLANGED PLUG VALVE (3") CAST-IRON FLANGED CHECK VALVE 3" HDPE SDR11 (HEAT FUSED CONNECTIONS) SLIDE RAILS 1 SCHAO AISI 304SS PIPE CONCRETE GROUT AS REQ'D BY ENGINEER TO PREVENT FLOTATION 2.86 YD3 MAKE MONOLITHIC POUR WITH BOTTOM SLAB BASIN ANTI -FLOTATION FLANGE WETWELL BOTTOM BOLT & SUPPORT DETAIL PUMP DISCHARGE BASE 2" x 6" INTEGRAL FRP "C" CHANNEL BOTTOM SUPPORTS MIN. 1/2" DIA. x 3" SS BOLTS WELDED TO A (2" x 24" x 1 /4" ) SS ANCHOR PLATE EMBEDDED IN FIBERGLASS INCASE OF LIFT STATION FMI RGENCY CONTAC [ SIGN EMERGENCY, CALL NOTES: "###-###-#." 1. SIGN SHALL BE ALE —WEATHER, (WATERPROOF). (24 HOURS) 2. LLT[LRS AND NUMBERS SHALE BE 2 OR LARGER. COT) Z K11111001, 09 UA w Z t!} Z U- U 385 Douglas Avenue, Ste 2100 Altamonte Springs, FL 32714 Telephone 407.478.8750 Facsimile 407.478.8749 Selby G. Weeks 56991 revision description date Al AGENCY COMMENTS 03.16.23 Q SJRWMD PAC 04.21.23 Q3 CITY COMMENTS o6.26.23 ® CITY COMMENTS 07.27.23 O 0 drawn by: JD checked by: SGW date: o8/05/2022 plot scale: AS SHOWN project number: N/A file name:C600-DTLS-WEST-21TSGDoo1.DWG Page 556 of 593 385 4ouglos Avenue. Ste 2100 Altamonte Springs, FL 32714 Telsoone 407.47&8750 Focsim le 407.47&8749 Todd W Bonnett, RLA FL *LA1718 N w F! N I 401 revision description date Al AGENCY COMMENTS 03.20.23 0 AGENCY COMMENTS 06.07.23 0 0 0 0 drawn by: TWB checked by: TWB date: 11/02/2022 plot scale: AS SHOWN project number: N/A file name: 2022.139_Lool-LA BASE-WEST.DWG Liol Page 557 of 593 GENERAL REQUIREMENTS The Landscape Contractor shall be responsible for all materials and all work as called for on the landscape plans. The list of plant quantities accompanying the plans shall be used as guide only. If a discrepancy occurs between the plans and the plant list, the plans shall control. The Landscape Contractor shall warranty all trees, shrubs, and ground covers for a period of one (1) year from the time of final acceptance by Owner, Grounds Department Representative, and Landscape Architect. The Landscape Contractor shall be wholly responsible for the stability and plumb condition of all trees and shall be legally liable for any damage caused by the instability of any plant material. Staking of trees shall be done utilizing a method prescribed by Orange County Public Schools. The Landscape Contractor shall research plans and contact appropriate agencies to determine the location of any utilities and obstructions prior to commencing work. Any utilities or unanticipated obstructions shall be reported to Landscape Architect or Owner immediately. All plant material areas shall have an automatic underground irrigation system providing 100% coverage. See Irrigation Design Plans for extent of irrigation for sodded areas. Positive drainage shall be maintained away from all structures on the site. PLANT SPECIFICATIONS All nursery stock plant material shall be Florida #I or better in accordance with Grades and Standards for Nursery Plants Parts I & 11, latest edition as published by the Florida Department of Agriculture and Consumer Services- Division of Plant Industry. All plant material shall be planted, fertilized and mulched as per the plant details and planting specifications noted on the plans. All container grown material shall be weed free, healthy, vigorous, well rooted plants, and established in the container in which they are delivered to the site. The plants shall have tops which are good quality and in a healthy growing condition. Established container grown plant material shall be grown in that container sufficiently long enough for the new fibrous roots to have developed enabling the root mass to retain it's shape when removed the container. Plants which have become root bound in the container are unacceptable. All plant material that is not container grown shall be freshly dug, sound, healthy, vigorous, well branched, and free of disease and insect eggs and larvae, and shall have adequate root systems. Where any requirements are omitted from the plant list, the plants furnished shall be normal for the variety. Plants may be pruned prior to delivery only upon the approval of the Landscape Architect. 9=11fiV4001 Granular fertilizer shall be uniform in composition, dry and free flowing. This fertilizer shall be delivered to the site in the original unopened bags bearing the manufacturer's statement of analysis. Granular fertilizer shall be a controlled release variety meeting the following requirements: sixteen percent (16%) nitrogen, four percent (4%) phosphorus, eight percent (8%) potassium, plus iron. Application Rates: Plant size 16-4-8 1 gallon 1/4 lb. 3 gallon 1/3 lb. 5 gallon 1/3 lb. 7-15 gallon 1/2 lb. 1" - 6" caliper 2 lbs. per I" caliper 6" + caliper 3 lbs. per 1 " caliper Sodded areas shall receive an application of the granular fertilizer (16-4-8) at a rate of 1/2 lb. of Nitrogen per 1,000 square feet of sod area. All Fertilizer shall be applied no sooner than 30 days after plant material, trees, and sod has been installed. SOIL Planting soil for use in preparing the backfill material for planting pits shall be added a rate of fifty percent (50%) planting soil to fifty percent (50%) existing soil. This soil mix shall be used in all plant pits. Planting soil shall be a fertile, friable natural topsoil of loamy character. It shall contain forty (40) to fifty (50) percent decomposed organic matter and be free of heavy clay, stones larger than 1" in diameter, noxious weeds and plants, sod, partially disintegrated debris, insects or any other undesirable material, plants or seeds that would be toxic or harmful to plant growth. MULCH All plant beds and tree watering basins shall be top dressed with three inches (3") of pine bark nuggets 6 =95 Refer to Landscape Plan for limits of sod. All areas disturbed by construction (including material staging, equipment storage, temporary facilities, site access, construction staff parking, etc.) beyond the minimum limits of sod as shown on the Landscape Plan shall be sodded as needed. All lawn areas to receive sod shall be disked four (4) to six (6) inches and graded to establish a level finished grade ensuring positive drainage from all structures. All debris shall be removed from the site. Sod shall be free of weeds and pests. It shall be laid evenly with tight fitting joints and rolled. The sod shall contain moist soil which does not fall apart or tear when lifted. See plant list for specific sod species and locations. See 'Fertilizer' for requirements of all sodded areas. CD FCED CD CD FENCING FABRIC ORANGE TENSAR GEOGRID (SNOW FENCE) OR AN APPROVED EQUAL. STAPLE TO VERTICAL 2X4 OR TIE TO METAL 'T" POSTS. EXISTING TREE METAL T " POST OR WOODEN 2X4 3' ROOT FLARE VISIBLE 10% OF ROOT BALL ABOVE SURROUNDING FINISHED GRADE TREE PIT PLANTING HOLE DEPTH 90% OF ROOT BALL 1. PLACE CONTINUOUS RUN OF FENCE MATERIAL ON BOTH SIDES OF IMMEDIATE WORK ZONE IN WOODED AREAS AS SHOWN ON THE PLANS. DO NOT ATTAC FENCE MATERIAL TO TREES. AC 2. TREE PROTECTION FENCING FABRIC TO BE PLACED 4' PAST THE CANOPY DRIP INE FOR TREES THAT ARE TO BE PROTECTED. 3."TENSAR" HIGH STRENGTH POLMER GEOGRID FABRIC BY TENSAR CORPORATIO W MORROW, GEORGIA OR APPROVED EQUAL .08" THICK POLYETHYLENE ROOT '71 litoft L TREE PROTECTION DETAIL N.T.S. NOTE: TREE FROG RBK 40PT. SYSI TREE FROG ENVIRONMENTAL PR REMOVE TOP 1/3 OF BURLAP AND WIRE BASKET IF B&B TREE PROVIDED, .08" THICK POLYETHYLENE ROOT BARRIER (SURROUND APPLICATION) BY CENTURY ROOT BARRIER OR APPROVED EQUAL. ROOT BARRIERS TO BE APPLIED FOR TREE APPLICATIONS WITHIN 150R LESS OF CURB LINES TREE PLANTING DETAIL REMOVE BURLAP & WIRE BASKET FROM TOP 1/3 OF ROOTBALL FOR ALL B&B TREE SET TOP OF ROOT BALL MULCH OVER GUYING 3" MULCH MIN. (TYP.), DO NOT MULCH OVER ROOT BALL MULCH RING SHALL BE 2' PAST ROOT BALL PIT SOIL BERM 6" (TYP.) PREPARE PLANTING SOIL AS SPECIFIED UNDISTURBED SOIL ARROWHEAD 310-DEGRADABLE ANCHOR N.T.S. BARRIER (SURROUND APPLICATION) BY CENTURY ROOT BARRIER OR ROOTBALL DIA. APPROVED EQUAL. ROOT BARRIERS TO BE APPLIED FOR TREE APPLICATIONS WITHIN I O'OR LESS OF CURB LINES SMALL CANOPY TREE PLANTING DETAIL SPREAD. MULTI -TRUNK PLANTING DETAIL NOTE: DETAIL FOR USE WITH TREES UNDER 12' IN HEIGHT 2" DIA. X 8'LONG PRESSURE TREATED POLE (2 PER TREE) TOP -MOST ROOT IN ROOT BALL AT SURFACE REMOVE TOP 1/3 OF BURLAP FROM ROOT BALL 3" MULCH MIN. (TYP.), DO NOT MULCH OVER ROOT BALL 4" SOIL BERM (TYP.) UNDISTURBED SOIL BACKFILL WITH NATIVE SOIL, SUPPLEMENT SOIL AS SPECIFIED IN GENERAL NOTES PRESSURE TREATED POLES EXTEND 2' INTO UNDISTURBED SOIL N.T.S. PLAN VIEW X= SPACING ON CENTER (0 cI wifil. , W SHALL FOLLOW BED LINE 3" MIN. MULCH(FYP.) 6" TYP. SOIL BERM TO HOLD WATER FINISHED GRADE 12" MIN. DEPTH OF PLANTING SOIL FOR GROUNDCOVER BED PREPARE PLANTING SOIL AS SPECIFIED IN GENERAL LANDSCAPE NOTES EXISTING SUB SOIL DUILUIINV SHRUB AND GROUNDCOVER PLANTING DETAIL N.T.S. N.T.S. !EE FROG RBK 20PT. SYSTEM )G ENVIRONMENTAL PRODUCTS BASE OF TREE SHALL BE PLANTED SLIGHTLY ABOVE ADJACENT FINISH GRADE SET TOP OF ROOT BALL MULCH OVER GUYING 3" MULCH COVER (TYP.) 1" OVER ROOTBALL. NO MULCH AGAINST TRUNK 6" SOIL SAUCER DIAMETER OF TREE PIT TO BE TWICE THE DIAMETER OF THE ROOT BALL. ROUGHEN SIDE OF TREE PIT PULVERIZED SOIL BACKFILL UNDISTURBED SUBGRADE ARBORGUY RBK 20 PLAN VIEW W/ STRAPPING TREE PLANTING PLAN DETAIL TYPICAL PLANTING AT FIRE HYDRANT N.T.S. B0NNETTdesign group, 11c landscape architecture community planning FL LC 26000341 400 S. Orlando Ave. Suite 201 Maitland, FL 32751 407.622.1588 voice 12" + HT. SHRUB CANOPY TREE PROPOSED FIRE DEPT. CONNECTION CLEAR AREA PLAN TREES AND SHRUBS TALLER THAN 12" SHALL NOT BE PLANTED ANY CLOSER THAN *-0" FROM THE BACK OR 7-6" FROM EACH SIDE OF A FIRE HYDRANT OR FIRE DEPT. CONNECTION NO TREES OR SHRUBS SHALL BE PLANTED IN FRONT OF A FIRE HYDRANT OR FIRE DEPT. CONNECTION. TURF AND GROUNDCOVER SHORTER THAN 12" IS PERMITTED WITHIN THE CLEARANCE AREA SECTION 385 Ow9los AveInue, Sle, 2100 Allornonle Springs. FL 32714 Telephone 407.47&8750 Focsimh* 407.47&8749 Todd W Bormett, RLA FL #LA1718 cq revision description date AGENCY COMMENTS 03.20.23 drawn by: TWB checked by: TWB date: 11/02/2022 plot scale: AS SHOWN project number: N/A file name: 2022.139—Loo1-LA BASE-WEST.DWG Lio2 rftwm XIMI.I.M-1A &M-101Ifte ft Oft - kok ft &M3 *5701 Page 558 of 593 BONIVETZ design group, 11c landscape architecture community planning FL LC 26000341 400 S. Orlando Ave. Suite 201 Maitland, FL 32751 407.622.1588 voice 385 0ouglos Avenue. Ste 2100 Altamonte 9s, FL 32714 Telephone 407.47&8750 Focsttnhe 407,478,8749 Todd W Bonnett, RLA FL *LA1718 F! N 401 revision description date Al 0 0 0 0 0 AGENCY COMMENTS 03.20.23 AGENCY COMMENTS o6.07.23 drawn by: TWB checked by: TWB date: 11/02/2022 plot scale: AS SHOWN project number: N/A file name: 2022.139_Lool-IRRIGATION 1 BASE-WEST.DWG as Fimm m 2MIJ9.L NM-/ihf, UN BASE-USU" PM 0M m a*. OL 203 kolas Page 559 of 593 1) REFER TO THE LANDSCAPE PLANS WHEN TRENCHING TO AVOID TREES AND SHRUBS. HAND DIG AROUND ANY EXISTING TREES. DO NOT CUT ANY ROOTS OVER 2" IN DIAMETER. 2) ALL MAINLINE PIPING SHALL BE BURIED TO A MINIMUM DEPTH OF 18" OF COVER. ALL LATERAL PIPING SHALL BE BURIED TO A MINIMUM DEPTH OF 12" OF COVER. 3) ALL POP-UP ROTORS AND SPRAYS SHALL BE INSTALLED USING AN 18" PVC FLEX PIPE CONNECTION. DO NOT USE POLYETHYLENE PIPE. USE WELDON 737 WITH A PURPLE PRIMER OR RED HOT CHRISTY'S BLUE GLUE ON ALL CONNECTIONS. 4) ADJUST ALL NOZZLES TO REDUCE WATER WASTE ON HARD SURFACES, WINDOWS AND BLDG. WALLS. THROTTLE ALL VALVES ON SHRUB LINES AS REQUIRED TO PREVENT FOGGING. USE ADJUSTABLE NOZZLES WHERE REQUIRED TO AVOID ANY WATER ON BUILDING WINDOWS. 5) NO RISERS SHALL BE USED. 6) ALL CONTROL WIRE CONNECTIONS SHALL BE MADE IN VALVE BOXES USING 3M DBR-Y WIRE CONNECTORS AND SEALANT WITH WIRE NUTS. 7) THE CONTRACTOR SHALL PREPARE AN AS -BUILT DRAWING SHOWING ALL IRRIGATION INSTALLATION. THE CONTRACTOR SHALL NEATLY MARK IN RED INK ON A WHITE BOND PAPER COPY OF THE IRRIGATION PLAN ANY INSTALLATION THAT DEVIATES FROM THE PLAN. THE AS -BUILT DRAWING SHALL ALSO LOCATE ALL MAINLINE AND VALVES BY SHOWING EXACT MEASUREMENTS FROM HARD SURFACES. MEASUREMENTS SHALL BE MARKED ON THE PLAN EVEN WHEN THE EQUIPMENT IS INSTALLED IN THE EXACT LOCATION AS THE PLAN. PROVIDE THE OWNER A PDF OF THE AS -BUILT PLAN. 8) ALL VALVES, GATE VALVES AND QUICK COUPLERS SHALL BE INSTALLED IN VALVE BOXES. THE VALVE BOXES SHALL BE PURPLE WHEN USING RECLAIMED WATER. 9) ANY PIPING SHOWN OUTSIDE THE PROPERTY LINE OR RUNNING OUTSIDE A LANDSCAPE AREA IS SHOWN THERE FOR CLARITY ONLY. ALL LINES SHALL BE INSTALLED ON THE PROPERTY AND INSIDE THE LANDSCAPE AREAS OR INSIDE A SCH. 40 SLEEVE. 10) ALL HEADS SHALL BE INSTALLED A MINIMUM OF 24" FROM ANY WALL AND A MINIMUM OF 6" FROM ANY SIDEWALK, PATIO OR ROAD. (MINIMUM OF 2'-0" WHERE THERE ARE NO BUMPER STOPS) 11) THE CONTRACTOR SHALL EXERCISE CARE SO AS NOT TO DAMAGE ANY EXISTING UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE IMMEDIATE REPAIRS AND COST OF ANY DAMAGE CAUSED BY THEIR WORK. 12) ALL WORK SHALL BE GUARANTEED FOR ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE AGAINST ALL DEFECTS IN EQUIPMENT AND WORKMANSHIP OR AS OUTLINED IN THE WRITTEN SPECIFICATIONS. 13) ELECTRICAL SERVICE TO LOCATION OF THE CONTROLLER, WELL OR PUMP SHALL BE PROVIDED TO A JUNCTION BOX OR DISCONNECT AT THE EQUIPMENT LOCATION BY THE ELECTRICAL CONTRACTOR OR BY OWNER WHEN IT IS NOT PART OF THE BID PACKAGE. CONFIRM THE LOCATION OF THE CONTROLLER WITH THE OWNER OR GENERAL CONTRACTOR BEFORE ANY INSTALLATION. 14) IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO SCALE THE PLAN AND CHECK NOZZLE TYPES TO DETERMINE THE CORRECT SPACING OF THE HEADS. THE CONTRACTOR SHALL NOT SPACE THE HEADS FURTHER APART OR USE LESS HEADS THAN SHOWN ON THE PLAN. ANY CHANGES TO THE HEAD SPACING OR LAYOUT, WITHOUT THE CONSENT OF THE LANDSCAPE ARCHITECT OR OWNER, SHALL HOLD THE IRRIGATION CONTRACTOR RESPONSIBLE FOR WARRANTY OF THE PLANTS AND OR SOD IN THESE AREAS. 15) 48 HOURS BEFORE DIGGING, CALL 1-800-432-4770 (SUNSHINE STATE ONE CALL CENTER) 16) INSTALL THREE EXTRA CONTROL WIRES TO EACH TERMINATION OF THE MAIN. ALL CONTROL WIRES SHALL BE INSTALLED INSIDE OF SCH. 40 GRAY PVC CONDUIT WHERE THEY CANNOT BE UNDER THE MAIN. ZONE CHART ZONE PLANT IRRIGATION WATER PRECIP. APPLIC. GPM MINUTES TOTAL (TYPE) (TYPE) (DEMAND) (RATE) (IN. PER WEEK REQ.) (GPM) (PER CYCLE) (GALLONS) 1 TREE BUBBLER MEDIUM 1.5 1.0 12 20 240 2 PLANT DRIP MEDIUM 1.5 1.0 25 20 500 3 SOD SPRAY LOW 0.75 0.5 18 20 360 4 PLANT DRIP MEDIUM 1.5 1.0 14 20 280 5 TREE BUBBLER MEDIUM 1.5 1.0 13 20 260 6 SOD SPRAY LOW 0.75 0.5 15 20 300 7 PLANT DRIP MEDIUM 1.5 1.0 34 20 680 8 TREE BUBBLER MEDIUM 1.5 1.0 10 20 200 TOTAL GPM PER RUN CYCLE 141 160 2,820 TOTAL GPM PER WEEK 5,640 (PEAK WEEKLY DEMAND) THE RUN TIMES SHOWN FOR THE ZONE IS FOR ONE RUN CYCLE AND WILL PROVIDE HALF THE REQUIRED AMOUNT OF WATER NEEDED PER WEEK. TWO RUN CYCLES PER WEEK ARE REQUIRED TO PROVIDE THE TOTAL WEEKLY REQUIREMENT. ALL RUN TIMES SHALL BE SET TO FOLLOW THE CURRENT WATER MANAGEMENT DISTRICT REGULATIONS AND REDUCED TO ONLY ONE RUN TIME PER WEEK WHEN RESTRICTED BY DAYLIGHT SAVINGS TIME OR WATER RESTRICTIONS. THE ZONE CHART IS PROVIDED AS A GENERAL OUTLINE ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE TO SET THE RUN TIMES BASED ON THE SPECIFIC SITE CONDITIONS AND PLANT REQUIREMENTS. THIS SHALL INCLUDE, BUT NOT LIMITED TO, SOIL TYPE, DRAINAGE, SLOPES, SUN EXPOSURE AND THE ESTABLISHMENT PERIOD. THE TOTAL GPM REQUIRED PER YEAR WILL BE LESS THAN THE PEAK DEMAND PER WEEK TIMES 52 WEEKS, BASED ON THE RUN TIMES BEING REDUCED BY SENSORS AND A REDUCED WATER DEMAND IN THE WINTER MONTHS. MULCH (SEE LANDSCAPE PLAN) BARBED FITTING FINISH GRADE DRIP TUBING SEE LEGEND BLANK TUBING L DRIP TUBING 12" SEE LEGEND INSTALL A'U" SHAPED WIRE STABILIZER EVERY 5'. ANTELCO XPANDO TAKE -OFF ADAPTER, CAPO RUBBER GROMMET AND RATCHET CLAMP. PVC TEE (SxSxS) CONNECT TO HEADER PIPE 12" O.C. THE MINIMUM SIZE SHALL BE 1 1/2" CENTER MANIFOLD END MANIFOLD MANIFOLD CONNECTION DETAIL PVC SUPPLY HEADER FLUSH VALVE ASSEMBLY -PLANT BED CONTROL VALVE ASSEMBLY 9i ,.�-yp ■yam �_.y/R EXISTING SOIL - COMPACT THE BACKFILL TO AVOID SETTLING LATERAL OR MAINLINE U CONTROL WIRES ' TRENCHING DETAIL 12" FOR LATERAL PIPE AND 18" FOR THE MAIN. • 1) INSTALL ALL DRIP TUBING AT GROUND LEVEL AFTER PLANT INSTALLATION. INSTALL NETAFIM TLS6 U SHAPED WIRE STABILIZERS A MIN. OF 4' O.C. TO HOLD THE LINES IN PLACE. 2) KEEP ALL DRIP LINE CLEAN AT ALL TIMES BEFORE THE FINAL CONNECTION. ALL TUBE ENDS SHALL BE INTERCONNECTED TO ALL OTHER DRIP TUBES. DO NOT DEAD END TUBING. SINGLE ROWS SHALL HAVE A END CAP AND NOT BENT OVER OR TAPED. 3) AVOID SHARP BENDS IN THE TUBING. DO NOT BEND THE TUBING WITH LESS THEN A 12" RADIUS. THERE SHALL NOT BE ANY KINKS IN THE TUBING. 4) ALL DRIP TUBING SHALL HAVE UNIFORM SPACING AND BURIAL DEPTH. THE PLAN DOES NOT ALWAYS REFLECT THE EXACT SPACING OR LAYOUT OF THE TUBING. LAYOUT THE TUBING DOWN THE LONGEST WIDTH WHEN POSSIBLE. ADAPT THE TUBING TO CURVED BEDS OR PLANTERS AS REQUIRED. ADJUST AND ADAPT THE TUBING FOR ALL TREES. REFER TO THE TREE DRIP RING DETAIL. 5) INSTALL DRIP TUBING TO ALL AREAS THAT SHALL RECEIVE PLANT MATERIAL. SEE THE LANDSCAPE PLAN FOR THE EXACT LOCATIONS. THERE SHALL BE A MINIMUM OF TWO ROWS OF TUBING ON A SINGLE ROW OF PLANTS. 6) SPACE TUBING AS NOTED ON THE PLAN. DO NOT SNAKE TUBING BACK AND FORTH EXCEPT WHERE SHOWN ON THE PLAN. ALWAYS INSTALL A HEADER PIPE UNLESS THE TOTAL GALLONAGE OF AN AREA IS 3 GPM OR LESS. 7) REFER TO THE MANUFACTURERS DRIP INSTALLATION MANUAL FOR INSTALLATION INSTRUCTIONS. ALL FITTINGS SHALL BE THE SAME TYPE AND MANUFACTURER AS THE DRIP TUBING. 8) ALWAYS FLUSH ALL LINES BEFORE FINAL CONNECTION. 9) INSTALL A A "SYSTEM ON" INDICATOR FLAG ON EVERY ZONE WHERE IT IS SEEN FROM THE CONTROL VALVE. 10) INSTALL FLUSH VALVES WHERE SHOWN AT THE ENDS OF EACH RUN OF DRIP TUBING AND ONE FOR EVERY 15 GPM OF TUBING. 11) CLEARLY AND NEATLY MARK THE TOP OF EACH VALVE BOX WITH THE TYPE OF EQUIPMENT THAT IT CONTAINS. (I.E. VALVE, FLUSH VALVE, ETC.) 12) THE DRIP ZONE VALVE ASSEMBLY SHALL BE PLACED INSIDE AN ARMOR JUMBO VALVE BOX. THE VALVE SHALL BE INSTALLED AS PER THE DETAIL ON THE PLANS. 13) THE DRIP TUBING SHALL HAVE EMITTERS EVERY 12" AND SHALL BE SPACED 12" APART IN GROUND COVER BEDS AND A MINIMUM OF TWO RUNS FOR EACH ROW OF SHRUBS WHEN THE SHRUBS ARE SPACED FARTHER THAN 2' ON CENTER. 14) REFER TO THE ZONE CONTROL KIT DETAIL FOR FILTER SIZES. 15) THE IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE HIS/HER WORK WITH THE LANDSCAPE CONTRACTOR. NOZZLE CHART G.P.M. LETTER SPEC. COLOR 40 PSI DISTANCE RADIUS ZONE LABELS A MP2000 RED 1.47 19, FULL 360° ZONE NUMBER GPM "' ZONE CANT SOD M TREESS HIGH WATER USE MEDIUM LOW B MP CORNER TURQUOISE .45 14' CORNER 105° C MP CORNER TURQUOISE .19 14' CORNER 45° D MP2000 BLACK .74 19, HALF 180° F MP2000 BLACK A0 19, QUARTER 90° G MP END STRIP COPPER .22 5' X 15' END STRIP H RAIN. XPCN BLACK .23 4.5' HALF PATTERN K MP815 OLIVE 1.87 8'-16' FULL 360° M MP SIDE S BROWN .44 5' X 30' SIDE STRIP S MP815 MAROON .49 8'-16' 90 180 ° T MP815 MAROON .93 8'-16' 90 180 ° V MP3000 BLUE .86 30' QUARTER 90 W MP3000 BLUE 1.82 30' HALF 180° X MP3000 YELLOW 2.73 30' THREE QTR. 270 ° Y MP3000 GRAY 3.64 30' FULL 360° Z MP2000 GREEN 1.10 19, THREE QTR. 270` THE NOZZLES LISTED SHOW THE TYPE OF MP ROTATOR NOZZLE THAT SHOULD BE USED. THE CONTRACTOR SHOULD INSTALL CORRECT NOZZLE IN EACH HEAD AS SHOWN BY THE LETTER BESIDE THE HEAD ON THE PLAN. DO NOT USE MP1000 SERIES NOZZLES. THE GPM, DISTANCE AND ANGLE ON THE NOZZLE CHART ARE APPROXIMATE. THE CONTRACTOR SHALL ADJUST ALL NOZZLES TO PROVIDE THE 100% COVERAGE, BUT LIMIT OVERTHROW ON TO BUILDINGS, WALLS, PAVEMENT, ETC. THE HEADS SHALL BE SPACED AS PER THE PLAN. SCALE THE PLAN FOR DISTANCE. DO NOT ASSUME THAT ALL HEADS ARE SPACED AS PER CONVENTIONAL SPRAY HEADS. THE PRECIPITATION RATE FOR THESE NOZZLES IS LESS THAN A CONVENTIONAL SPRAY NOZZLE. FOLLOW THE ZONE CHART FOR AN APPROXIMATE RUN TIME FOR EACH ZONE, BUT SET THE RUN TIME ON THE CONTROLLER BASED ON THE SPECIFIC SITE CONDITIONS. DO NOT SUBSTITUTE WITH STANDARD NOZZLES. INSTALL A DRIP RING AROUND ALL TREES WITHIN THE DRIP TUBING AREAS OR AS INDICATED ON THE LEGEND. I DRIP TUBING/PVC LATERAL 6" RAINBIRD XERI-BUBBLER INSTALL THREE RAINBIRD a Oa XERI-BUBBLERS (UXB-360) 0-357BALL ALL CANOPY TREES AND ANY Ta GALLON OR LARGER (1 TO 2 GS REQUIRED TO PROVIDE PROPE COVERAGE. 12" TREE ROOT NETAFIM DLOOP DRIP BUBBLER DETAIL BRAND F-VALVE INTO LID FOR VALVE FINISH GRADE RAINBIRD SUBTERRANEAN EMITTER BOX AUTO FLUSH VALVE BLANK TUBING FLUSH VALVE II MULCH LEGENDUSE HUNTER MP ROTATOR NOZZLES • 1 HUNTER PRS40 6" POP-UP SPRAY HEAD ® I TWO HUNTER AFB ADJUSTABLE FLOOD BUBBLERS PER TREE ONETAFIM DRIP BUBBLER TREE RING- REFER TO DRIP BUBBLER DETAIL HUNTER DRIP ZONE ECO-INDICATOR- REFER TO THE DETAIL (NOT SHOWN ON THE PLAN) A NETAFIM FLUSH VALVE (NOT SHOWN ON THE PLAN) NETAFIM COPPER TECHLINE CV 17MM DRIP TUBING- 1 GPH EMITTERS EVERY 12". GROUNDCOVER PLACE ROWS 12" APART IN ALL GROUND COVER BEDS. INSTALL A DOUBLE ROW ON ALL HEDGE ROWS. REFER TO ALL NOTES AND DETAILS ON THIS SHEET. HEDGE CLASS 200 PVC MAINLINE-2" CLASS 200 PVC LATERAL LINE- SIZE AS SHOWN UNTIL A SMALLER SIZE IS SHOWN. MINIMUM SIZE OF 3/4" MONEEr SCH. 40 SLEEVE (MINIMUM OF 24" DEPTH AND 2 SIZES LARGER THAN THE PIPE SIZE OR AS LABELED ON THE PLAN) HUNTER ICV ELECTRIC VALVE. SIZE AS SHOWN BELOW. INSTALL VALVE IN A 11"X17" VALVE BOX AND COVER 0-25 GPM=1" 26-50 GPM=1 1/2" ® HUNTER ZONE CONTROL KIT- REFER TO THE DETAIL. t9V1V1VC11 QeSZgJZSroup, 66C landscape architecture community planning FL LC 26000341 400 S. Orlando Ave. Suite 201 Maitland, FL 32751 407.622.1588 voice C00 z 00 -Y, UJ w z 0 UJ 385 Oou9ios Avenue, Ste 2100 Altamonte Sprrn9so FL 32714 Telephone 407,47&8750 Focsknl* 407,47&8749 Todd W Bonnett, RLA FL #LA1718 CONTROLLER- HUNTER ICC-2. WHERE SHOWN ON THE PLAN. INSTALL WITH A HUNTER MINI-CLIK RAIN SENSOR. GROUND WITH A MINIMUM 8' COPPER CLAD ROD. SLEEVE TO AS REQUIRED. POINT OF CONNECTION TO A 1 1/2" POTABLE IRRIGATION METER AND P BACKFLOW PREVENTER. REFER TO THE UTILITY PLAN FOR THE EXACT LOCATION AND DETAILS. W CITY OF OCOEE NOTES THE DEVELOPER/ CONTRACTOR SHALL COORDINATE WITH UTILITIES DEPARTMENT FOR WATER CONSERVATION INSPECTION OF PLUMBING AND IRRIGATION SYSTEM BY CALLING 407-905-3159. FINAL IRRIGATION PLAN APPROVAL DOES NOT PROVIDE EXEMPTION FROM CITY OF OCOEE CODE OF ORDINANCES w CHAPTER 175 LANDSCAPE IRRIGATION REQUIREMENTS. ANY DEVIATIONS MUST BE APPROVED IN WRITING PRIOR TO CONSTRUCTION. HIGH VOLUME IRRIGATION (SPRAY HEADS) IS USED ON LESS THAN 60% OF THE LANDSCAPE AREA. DRIP TUBING (MICRO -IRRIGATION) AND NON -IRRIGATED AREAS IS USED TO MEET THIS REQUIREMENT. THIS PROJECT, INCLUDING BOTH HORIZONTAL AND VERTICAL CONSTRUCTION, SHALL INCORPORATE WATERSENSE PLUMBING FIXTURES AND ENGERY STAR APPLIANCES AS REQUIRED BY CHAPTER 175 OF THE CITY OF OCOEE'S CODE OF ORDINANCES. I AN VIEW LEGEND 1. HUNTER ICZ-101 1" A CONTROL ZONE KIT. (0-20 GPM) B HUNTER ICZ-151 1 1/2' CONTROL ZONE KIT. (21-60 GPM) 2. CONTINUE 14 GAUGE WIRE TO THE CONTROLLER. INSTALL THE WIRE UNDER THE MAIN. INSTALL IN CONDUIT WHERE THE MAIN DOES NOT CONTINUE. (EXCEPT TWO -WIRE SYSTEMS) 3. HUNTER ICV VALVE 4. WATERPROOF CONNECTORS (DBY ON TWO -WIRE SYS.) 5. PVC UNION FOR SERVICING ASSEMBLY. 6. JUMBO PLASTIC VALVE BOX. 7. PVC PIPE FROM POINT OF CONNECTION. (45 OR 90 DEG.) 8. PVC PIPE TO IRRIGATION ZONE. 9. SOIL SEPARATOR FABRIC W/ BRICK UNDER EACH CORNER 10. FINISHED GRADE. REFER TO THE DECODER DETAILS FOR TWO -WIRE SYSTEMS FOR DECODERS, WIRE SPECIFICATIONS AND WIRE NUTS. ZONE CONTROL KIT DETAIL * ALL VALVE BOXES SHALL BE MARKED INSIDE WITH THE ZONE NUMBER ON PLASTIC CHRISTY TAGS OR AS PER THE WRITTEN SPECIFICATIONS. * DO NOT MANIFOLD THE VALVES. EACH VALVE SHALL BE ON A SEPARATE TEE ON THE MAIN. ALL VALVES SHALL BE A MINIMUM OF 6' APART AND INSTALLED IN THE SOD AREA. LABEL LID (IRRIGATION) 11"X17" VALVE BOX FINISH GRADE , KING "ONE STEP" 6" MIN. CONNECTORS EXPANSION SURGE CABLE 45 OR 90 VALVE 4 5 OR 90 PLACE A BRICK TO LATERAL LINE UNDER EACH TEE SOIL SEPARATOR FABRIC CORNER MAINLINE PLACE CONTROL WIRES UNDER MAIN ELECTRICAL VALVE WOOD STAKE WITH YELLOW RIBBON LABEL "IRRIGATION SLEEVES" (EACH END OF SLEEVES) MIN. OF ROADWAY MIN. OF 30" GREEN SPACE ABOVE GRADE MINIMUM OF, 24" BELOW ROADS 18" BELOW SIDEWALKS SCH. 40 SLEEVE (SEE PLAN FOR SIZES) -CAP(UNGLUED) CAP (UNGLUED) SLEEVE DETAIL EXTEND PAST EVE OF BLDG. ELECTRICAL CONDUIT 120 V. PVC CONDUIT TO THE START OJ8' MAINLINE. PLACE WIRES UNDE OR INSIDE CONDUIT. GROUND WITH 5/8" X 8' COPPER RODS TO 10 OHM'S OR LESS. M CONNECTION WITH CADWELD P SHOT. VALVE BOX/GROUND RODS. INS@ ALL MIN. OF 8' FROM CONTROLLER AAPART.CADWELD PLUS ONE SHOT.GROUND ROD WIRE AS PER LOCAL CODE PLACE THE RAIN SENSOR TO RECEIVE RAIN FROM ALL DIRECTIONS. CONTROLLER DETAIL revision description date Ai AGENCY COMMENTS 03.20.23 0 0 0 0 drawn by: TWB checked by: TWB date: 11/02/2022 plot scale: AS SHOWN project number: N/A file name: 2022.139_Lool-IRRIGATION 1 BASE-WEST.DWG L2o2 Page 560 of 593 T.O. PANEL ELEV. +45'-0" T.O. PANEL ELEV. +43'-0" OIL FINISH FLOOR ELEV. +0'-0" OIL T.O. PANEL ELEV. +38'-8" OIL FINISH FLOOR ELEV. +0'-0" T.O. PANEL ELEV. +38'-8" STRUCK APRON ELEV. -4'-0" T.O. PANEL ELEV. +45'-0" T.O. PANEL ELEV. +39'-8" FINISH FLOOR � ELEV. +0'-0" T.O. PANEL ELEV. +45'-0" T.O. PANEL ELEV. +43'-0" FINISH FLOOR ELEV. +0'-0" T.O. PANEL ELEV. +38'-8" FINISH FLOOR ELEV. +0'-0" THIS INSTRUMENT PREPARED BY AND SHOULD BE RETURNED TO: PREPARED BY: Richard S. Geller, Esq. FISHBACK DOMINICK, LLP. 1947 Lee Road Winter Park, FL 32789 RETURN TO: Melanie Sibbitt, City Clerk CITY OF OCOEE 1 North Bluford Avenue Ocoee, FL 34761 DEVELOPMENT AGREEMENT 429 Business Center Phase II West Development For Recording Purposes Only THIS DEVELOPMENT AGREEMENT (this "Agreement") is made and entered into as of the day of December, 2023, by and between 409 OCOEE APOPKA, LLC, a Florida limited liability company, whose post office address is 250 South Orange Avenue, Suite 700, Orlando, Florida 32801 (together with its successors and assigns, hereinafter referred to as the "Owner") and the CITY OF OCOEE, a Florida municipal corporation, whose mailing address is 1 North Bluford, Ocoee, Florida 34761 (hereinafter referred to as the "City"). WHEREAS, Owner owns fee simple title to certain lands located within the corporate limits of the City of Ocoee, Florida, said lands being more particularly described in Exhibit "A" attached hereto and by this reference made a part hereof (hereinafter referred to as the "Property"); and WHEREAS, Owner has submitted to the City an application for a Large -Scale Preliminary Site Plan for construction of 70,720 square feet of light industrial and flex warehouse space (the "Application"); and WHEREAS, the Planning and Zoning Commission has held a public hearing to review the Application and at such hearing found the Application to be consistent with the intent of the Comprehensive Plan, Land Development Code and State Road (SR) 429 Overlay District Business Character Area and has recommended that the Ocoee City Commission approve the Application subject to conditions of approval; and WHEREAS, the City has required that Owner execute this Agreement as a condition precedent to the consideration of the Application by the Ocoee City Commission; and WHEREAS, the City has determined that the execution of this Agreement is essential to the public health, safety and welfare and the ability of the City to plan for proper traffic circulation and utility facilities and services in the vicinity of the Property in accordance with the Ocoee Comprehensive Plan; and Page 1 of 15 Page 562 of 593 WHEREAS, the City has determined that final approval of the Application and development of the Property shall be subject to the terms, conditions and limitations hereinafter set forth; and WHEREAS, pursuant to the Application of the Owner, on , 20 , the Ocoee City Commission approved the Large -Scale Preliminary Site Plan Application; and WHEREAS, the provisions of Section 4-10 of Article IV of the Ocoee Land Development Code require that Owner and the City enter into a development agreement incorporating all plans and conditions of approval by reference; and WHEREAS, Owner and the City desire to execute this Agreement in order to fully comply with the provisions of the Ocoee Land Development Code. NOW, THEREFORE, in consideration of the premises and other good and valuable considerations exchanged between the parties hereto, the receipt and sufficiency of which is hereby acknowledged, the parties hereto agree as follows: Section 1. Recitals. The above recitals are true and correct and incorporated herein by this reference. Section 2. Development Approvals. Nothing herein will be construed to grant or waive on behalf of the City any development approvals that may be required in connection with the Final Site Plan (as defined below) or the Owner's development of the Property. Notwithstanding this Agreement, the Owner must comply with all applicable procedures and standards relating to the development of the Property. Section 3. Development of the Property. A. Owner hereby agrees to develop the Property in accordance with that certain Large -Scale Preliminary Site Plan for the Property, date stamped as received by the City on (hereinafter referred to as the "Site Plan"), with such changes thereto as may be agreed upon in the approval of a Final Site Plan for the Property (the "Final Site Plan"). The Site Plan is hereby incorporated herein by reference as if fully set forth herein. B. The use of the Property, in accordance with the Site Plan, is for Light Industrial and Flex Warehouse Space. C. Owner hereby agrees that the Property shall be developed in accordance with and is made subject to those certain Conditions of Approval attached hereto as Exhibit "B" and by this reference made a part hereof (the "Conditions of Approval"). Owner further agrees to comply with all of the terms and provisions of the Conditions of Approval. D. Except as otherwise expressly set forth in this Agreement, the Site Plan and the Final Site Plan, it is agreed that (1) Owner shall comply with the zoning and Page 2 of 15 Page 563 of 593 subdivision regulations of the City as set forth in the Ocoee Land Development Code, as it may from time to time be amended, and (2) all preliminary site plans and final site plans for the Property or any portion thereof shall conform to the Ocoee Land Development Code requirements in effect at the time of approval of any such plans. In the event of any conflict between the provisions of the Ocoee Land Development Code, as it may from time to time be amended, and this Agreement, the Site Plan or the Final Site Plan, as applicable, it is agreed that the provisions of this Agreement, the Site Plan or the Final Site Plan, as applicable, shall control. E. Utility Improvements. The Owner shall be responsible for all of the following utility improvements: 1) All onsite water and sewer shall be privately owned and maintained. 2) All public utilities within easements and private utilities constructed within public rights -of -way shall be constructed to City standards. 3) No trees, shrubs or bushes shall be constructed on top of or within 10 feet of public utilities. 4) The Owner shall construct an on -site private lift station and force main with connection to the 429 Business Center Phase II East force main. Force main shall not be located within the right-of-way of the new east -west road. 5) Owner shall extend a new ductile iron watermain westward from the watermain constructed as part of the 429 Business Center Phase II East watermain to Pine Street. Line size shall be approved by Utilities under the Final Site Plan review. 6) Fire service shall be supplied from Ocoee Apopka Road. F. Drainage: Mass -grade permit issued prior to site plan approval) a) Protection of erosion b) Timing of permit c) Must have SJRWMD Permit G. Final Site Plan Drainage a) Phase drainage plan b) Easement language — Dedication of wetlands Page 3 of 15 Page 564 of 593 c) Drainage/stormwater run-off shall be maintained on -site H. Clear and grub permit a) A Stormwater Prevention Plan (SWPP) is required as part of a permit for the clearing and grubbing of land. b) Clear and Grub and or Mass Grading permit can be issued before Final Site Plan approval. I. Transportation Improvements a) [Intentionally deleted]. b) Design and construction to City standards of a new east - west road as a 50-ft public right-of-way from the 429 Business Center Phase II East boundary to Pine Street. Right-of-way dedication and design and construction of the new east -west road shall be at no cost to the City. Completion and dedication of the right-of-way shall be a condition precedent to obtaining a certificate of completion or occupancy for the Property; provided, however, that the City will accept the dedication of the right-of-way upon the satisfaction of all requirements for such dedication pursuant to applicable law. Section 4. Notice. Any notice delivered with respect to this Agreement shall be in writing and be deemed to be delivered (whether or not actually received) when (1) hand delivered to the other party at the address appearing on the first page of this Agreement, or (ii) when deposited in the United States Mail, postage prepaid, certified mail, return receipt requested, addressed to the party at the address appearing on the first page of this Agreement, or such other person or address as the party shall have specified by written notice to the other party delivered in accordance herewith. Section 5. Binding Effect and Successors. This Agreement shall run with the Property and the rights and the obligations under this Agreement shall benefit, burden, and bind the successors, heirs and assigns of all parties to this Agreement. The rights granted to Owner under this Agreement relate specifically to the Property and are not permitted to be transferred to any other property. Section 6. Recordation of Agreement. The parties hereto agree that an executed original of this Agreement shall be recorded by the City, at Owner's expense, in the Public Records of Orange County, Florida. The City will, from time to time upon request of Owner, execute and deliver letters affirming the status of this Agreement subject to reimbursement by Owner for all fees and costs incurred by the City. Page 4 of 15 Page 565 of 593 Section 7. Title to Property. Owner warrants and represents to the City that it is the fee simple owner of the Property, free and clear of any mortgages or liens, or, in the event a mortgage or lien exists, Owner, at Owner's sole cost, shall obtain the necessary joinders and consents and subordinations to this Agreement (and documents called for herein) or releases from the appropriate parties with an interest in the Property. Owner shall provide to City, certified surveys, title reports or other documents evidencing such ownership interest. Section 8. Applicable Law. This Agreement and the provisions contained herein shall be construed, controlled, and interpreted according to the laws of the State of Florida. Section 9. Time of the Essence. Time is hereby declared of the essence to the lawful performance of the duties and obligations contained in this Agreement. Section 10. Agreement; Amendment. This Agreement constitutes the entire agreement between the parties, and supersedes all previous discussions, understandings and agreements, with respect to the subject matter hereof. Amendments to and waivers of the provisions of this Agreement shall be made by the parties only in writing by formal amendment. Section 11. Further Documentation. The parties agree that at any time following a request therefor by the other party, each shall execute and deliver to the other party such further documents and instruments, in form and substance reasonably necessary to confirm and/or effectuate the obligations of either party hereunder. Section 12. Default. In the event of a breach, default, or violation of one or more of the material provisions herein by the Owner or the City, the violating party shall be given sixty (60) days to cure such violation upon receipt of written notice of the breach, default or violation from a non -violating party. In the event of a breach of this Agreement by the Owner or its successors and assigns that also constitutes a violation(s) of development order conditions and of a violation(s) of the Ocoee Land Development Code, the City may, in addition to other remedies, pursue code enforcement remedies afforded by law to cause the correction of such violation(s). In the event of a breach that is not cured within the aforementioned sixty (60) day notice period, the City shall be permitted to without further notice and Owner's opportunity to cure immediately withhold the issuance of and issue stop work orders on, certificates of occupancy, site permits and building permits associated with the Property, or any combination thereof, in the event Owner or its successors and assigns in interest, is in violation of any Florida Building Code, City of Ocoee Code of Ordinance or Ocoee Land Development Code provision(s) until the Owner's cure thereof consistent with such code. Notwithstanding anything to the contrary contained herein, in the event a Lender or a Successor Owner acquires title to the Property, neither such Lender nor any Successor Owner shall have any obligation to commence or complete the development of the Property (except as may be required by the City to satisfy life safety -related regulations) and in the event of any failure or election of any Successor Owner to so commence or complete, the City's only remedy hereunder shall be to terminate this Agreement and revoke its approval of the Site Plan and the Final Site Plan; provided, however, that upon the request of the City and at no cost to the City, the Lender or Successor Owner, as applicable, will convey to the City the portion of the Property on which the 50-foot public right- of-way described in Section 3Q) above was to be constructed. As used in this Section 12, (x) "Lender" means any lender making a loan secured by the property and (y) "Successor Owner" Page 5 of 15 Page 566 of 593 means Lender (or its designee or nominee) or any purchaser who acquires title to the Property via a foreclosure or deed -in -lieu of foreclosure in connection with the exercise of Lender's remedies under any such loan secured by the Property. Section 13. Attorneys' Fees. In the event that either party finds it necessary to commence an action against the other party to enforce any provision of this Agreement or because of a breach by the other party of any terms hereof, the prevailing party shall be entitled to recover from the other party its reasonable attorneys' fees, legal assistants' fees and costs incurred in connection therewith, at both trial and appellate levels, including bankruptcy proceedings, without regard to whether any legal proceedings are commenced or whether or not such action is prosecuted to judgment. Section 14. Non Waiver of Sovereign Immunity. Nothing contained in this Agreement nor in any instruments executed pursuant to the terms of this Agreement shall be construed as a waiver or attempted waiver by the City of its sovereign immunity under the Constitution and laws of the State of Florida. Section 15. Counterparts. This Agreement may be executed in any number of counterparts, each of which shall be deemed to be an original but all of which together shall constitute one and the same instrument. Section 16. Captions. Captions of the Sections and Subsections of this Agreement are for convenience and reference only, and the words contained therein shall in no way be held to explain, modify, amplify or aid in the interpretation, construction, or meaning of the provisions of this Agreement. Section 17. Severability. If any sentence, phrase, paragraph, provision, or portion of this Agreement is for any reason held invalid or unconstitutional by any court of competent jurisdiction, such portion shall be deemed a separate, distinct, and independent provision and such holding shall not affect the validity of the remaining portion hereof. Section 18. Effective Date. The Effective Date of this Agreement shall be the date when the City signs the Agreement. f►y[�I►/_rllil �if.`�C�l�i]w��1L�/ Page 6 of 15 Page 567 of 593 IN WITNESS WHEREOF, Owner and the City have caused this instrument to be executed by their duly authorized officers as of the day and year first above written. Signed, sealed and delivered in the presence of Print Name Print Name STATE OF FLORIDA COUNTY OF ORANGE OWNER: 409 OCOEE APOPKA, LLC, a Florida limited liability company By:_ Name: Title: I HEREBY CERTIFY that on this day, before me, an officer duly authorized in the State and County aforesaid to take acknowledgments, personally appeared , as Manager of 409 Ocoee Apopka, LLC, a Florida limited liability company, who [] is personally known to me or [ ] produced as identification. WITNESS my hand and official seal in the County and State last aforesaid this day of December, 2023. Signature of Notary Name of Notary (Typed, Printed or Stamped) Commission Number (if not legible on seal):_ My Commission Expires (if not legible on seal): Page 7 of 15 Page 568 of 593 Signed, sealed and delivered in the presence of: Print Name: Print Name: FOR USE AND RELIANCE ONLY BY THE CITY OF OCOEE, FLORIDA. Approved as to form and legality this day of FISHBACK DOMINICK, LLP City Attorney STATE OF FLORIDA COUNTY OF ORANGE CITY: CITY OF OCOEE, FLORIDA Attest: Rusty Johnson, Mayor Melanie Sibbitt, City Clerk (SEAL) APPROVED BY THE OCOEE CITY COMMISSION AT A MEETING HELD ON DAY OF , , UNDER AGENDA ITEM NO. I HEREBY CERTIFY that on this day, before me, an officer duly authorized in the State and County aforesaid to take acknowledgments, personally appeared RUSTY JOHNSON and MELANIE SIBBITT, personally known to me to be the Mayor and City Clerk, respectively, of the CITY OF OCOEE, FLORIDA and that they severally acknowledged executing the same in the presence of two subscribing witnesses, freely and voluntarily under authority duly vested in them by said municipality. day of WITNESS my hand and official seal in the County and State last aforesaid this Signature of Notary Name of Notary (Typed, Printed or Stamped) Commission Number (if not legible on seal): Page 8 of 15 Page 569 of 593 My Commission Expires (if not legible on seal): Page 9 of 15 Page 570 of 593 EXHIBIT "A" LEGAL DESCRIPTION FOR INFORMATION ONLY: ADDRESS: 701, 707 & 711 PINE ST (PARCEL ID: 18-22-28- 0000-00005, 18-22-28-0000-00106, 18-22-28-0000-00105) NORTH 1/2 OF THE SOUTHWEST 1/4 OF THE NORTHEAST 1/4 OF THE NORTHWEST 1/4 AND SOUTH 1/2 OF THE NORTHWEST 1/4 OF THE NORTHEAST 1/4 OF THE NORTHWEST 1/4 OF SECTION 18, TOWNSHIP 22 SOUTH, RANGE 28 EAST, ORANGE COUNTY, FLORIDA (LESS THE WEST 448 FEET OF THE SOUTH 1.00 FEET OF THE NORTH 1/2 OF THE SOUTHWEST 1/4 OF THE NORTHEAST 1/4 OF THE NORTHWEST 1/4 OF SECTION 18, TOWNSHIP 22 SOUTH, RANGE 28 EAST AND LESS THE LAND LYING EAST OF CENTER LINE OF THE DITCH SURVEY LINE DESCRIBED AS FOLLOWS: COMMENCE ON THE EAST LINE OF THE NORTHWEST 1/4 OF SECTION 18 AT A POINT 343.6 FEET NORTH OF THE SOUTHEAST CORNER THEREOF AND RUN SOUTH 89"02'48" WEST, 55.17 FEET; THENCE RUN NORTH 51°44'12" WEST, 996.47 FEET; THENCE RUN NORTH 00°57'42" WEST, 298.7 FEET; THENCE RUN NORTH 00030'18" EAST, 290.02 FEET; THENCE RUN NORTH 00°46'42" WEST, 255.38 FEET; THENCE RUN NORTH 07°33' 18" EAST, 318.92 FEET; THENCE RUN NORTH 04°59'18" EAST, 149.98 FEET; THENCE RUN NORTH 13°21'18" EAST, 152.42 FEET; THENCE RUN NORTH 02°18'42" WEST, 150.8 FEET TO THE NORTH LINE OF SAID SECTION 18); ALSO LESS THE SOUTH 20 FEET OF THE WEST 449 FEET OF THE ABOVE DESCRIBED PARCEL. LESS AND EXCEPT THAT PORTION CONVEYED TO THE CITY OF OCOEE BY SPECIAL WARRANTY DEED RECORDED SEPTEMBER 16, 2020, IN OFFICIAL RECORDS INSTRUMENT NUMBER 20200486135, PUBLIC RECORDS OF ORANGE COUNTY, FLORIDA. Page 10 of 15 Page 571 of 593 EXHIBIT "B" CONDITIONS OF APPROVAL Section A. General 1. The City of Ocoee, Florida (the "City") is subject to the terms, provisions and restrictions of Florida Statutes, Chapter 163, concerning moratoria on the issuance of building permits under certain circumstances. The City has no lawful authority to exempt any private entity or itself from the application of such state legislation and nothing herein shall be construed as such an exemption. 2. This project shall be developed in two (2) phases. 3. Each phase of the project will stand on its own with respect to public services (sewer, water, stormwater management, access and other related services). 4. Except as specifically noted on this plan, development of the property shall be consistent with the requirements of the City of Ocoee Code of Ordinances (the "Code"), which Code includes Chapter 180, the City of Ocoee Land Development Code (the "Land Development Code"). 5. Nothing herein shall be construed to waive any provision of the Land Development Code except to the extent expressly set forth on a waiver table or explicitly set out on the plan. 6. Any damage caused to any public streets as a result of the construction activities related to the project shall be promptly repaired by the Owner to the applicable governmental standards at the Owner's sole cost and expense. 7. There shall be no access from the property to any public streets except at the approved locations shown on the approved Final Site Plan. 8. All existing structures (including buildings, power lines, existing aerial and utility facilities) will be removed and/or terminated prior to or during construction of the development replacing those uses. 9. All legal instruments including, but not limited to (i) declarations of covenants, easements and restrictions for the property, if any; (ii) articles of incorporation and bylaws of the property owners' association, if any (the "Association"); and (iii) warranty deeds, easements and bill of sale documents to the Association, the City, the County and/or the St. Johns River Water Management District ("SJRWMD") shall be provided to the City for review and approval prior to platting all or a portion of the property. 10. Parking within the Property shall be provided in accordance with the Land Development Code or as otherwise set forth in the Final Site Plan. Page 11 of 15 Page 572 of 593 11. Each fire hydrant shall be painted OSHA yellow in color and a blue reflective marker shall be affixed to the street in the center of the lane closest to each hydrant. 12. The Owner of the Property shall be responsible for installing reuse lines along with the other subdivision infrastructure. At such time as reuse water is available to the Property, the Owner shall be responsible for connection to the reuse system lines. 13. Pursuant to the Land Development Code, all signage must be consistent with the legally assigned name of the development. Any subsequent change to the name of the development must be approved by the City Commission of the City. 14. To the extent these Conditions of Approval conflict with the Land Development Code, the provisions of these Conditions of Approval shall control. Section B. Trees 1. All landscape areas will be irrigated and have an automatic rain sensor. Section C. Easements/Utilities 1. All cross access, utility and drainage easements shall be provided prior to or at the time of permit issuance. 2. All existing onsite utilities including electrical, cable, TV, and telephone located in the road right of way shall be relocated as necessary and shall remain overhead. 4. Unless otherwise noted, there shall be a ten -foot (10') utility and drainage easement adjacent to all street rights -of -way. 5. Final easement dimensions will be shown on the Final Site Plan and will be sized to meet City requirements. 6. A perpetual, non-exclusive access easement over all internal roadways and other paved areas is hereby granted in favor of the City and other applicable authorities for law enforcement, fire and other emergency services. The City may require that the owner execute an easement in recordable form with respect to the foregoing. 7. An emergency access easement to the retention ponds and over all drainage easements shown on the Final Site Plan is hereby granted to the City for emergency maintenance purposes. The emergency access easement will not impose any obligation, burden, responsibility of liability upon the City to enter upon the property it does not own or take any action to repair or maintain the drainage system on the property. Section D. Association 1. Intentionally deleted. Section E. Streets Page 12 of 15 Page 573 of 593 1. Final street naming will be coordinated through the City. 2. The street identified as "New Road" on the northern border of the Property will be dedicated to the public following completion of the extension of Pine Street and the dedication thereof to the City. 3. Street lights, security lights and lighting for common areas meeting current Land Development Code requirements shall be installed by the Owner prior to Certificate of Completion at the Owner's expense. 4. Intentionally deleted. 5. The Owner shall construct appropriate curbs cuts to enable construction of ramps at all rights -of -way intersections (and other areas as reasonably required) in order to accommodate access to sidewalks and streets for persons who are in wheelchairs and other persons with disabilities. Sidewalks abutting each parcel or tract shall be constructed at the time of development of such parcel or tract. When sidewalks are constructed on corner locations, the sidewalks will be extended to the curb and the appropriate ramps will then be constructed. Sidewalks adjacent to common areas shall be constructed at the time of permanent construction of adjacent common areas. Section F. Stormwater Manallement System 1. All wet retention ponds will be unfenced with a maximum 5:1 side slope into the pond. Dry retention ponds will remain unfenced with a maximum 4:1 side slope. Retaining walls utilized in retention ponds shall have fencing atop the wall locations. 2. The development of this project will incorporate the stormwater needs of all public roads within the project. 3. All building setbacks from all retention areas shall be fifteen feet (15') feet from the top of the bank. 4. Unless otherwise specifically provided for, the SWMS, including all pipes, inlets, manholes, structures and retention ponds, will be owned, operated and maintained by the Owner. 5. Notwithstanding the conveyance of the retention ponds to the Owner or any provision to the contrary contained in these Conditions of Approval, the Owner shall remain responsible for the maintenance of the SWMS, including all retention ponds, until such time as: i. the entire SWMS for the project is constructed and the appropriate Certificate of Completion is issued by both the City and the SJRWMD; ii. the retention ponds intended to be conveyed to the Owner have in fact been conveyed to the Owner; Page 13 of 15 Page 574 of 593 iii. the Owner is designated as the maintenance entity on the records of the SJRWMD and all transfer records required by the SJRWMD have been executed and accepted by SJRWMD; iv. the City has been provided with a copy of the Owner's proposed maintenance plan with respect to the SWMS; and V. the City has been provided with a written statement from the Owner acknowledging receipt of the Owner's proposed maintenance plan with respect to the SWMS and that the Owner is responsible for the maintenance of the SWMS. 6. All common area improvements including entry features, walls, landscaping and sidewalks along all roads, as well as landscaping around the retention pond tracts and any lift station tract shall be completed to the extent agreed to with City staff prior to issuance of the Certificate of Completion for those corresponding phases. Section G. Wetlands/100 Year Flood Plain 1. All finished floor elevations will exceed the 100-year flood plain based elevation by a minimum of two (2) feet. 2. The Owner shall comply with all requirements of the City and other governmental entities with jurisdiction to protect the wetlands being preserved and to prevent any disturbance, siltation, or other construction below the natural wetland lines. Further, the areas below the natural wetland lines shall be fenced off (and silt fences shall be installed) during construction activities immediately adjacent to the wetlands, in order to minimize disturbances of the wetlands during construction. 3. Wetland and existing surface water impact for this property is regulated by SJRWMD and the Florida Department of Environmental Protection. General or individual permits are required from these agencies prior to commencement of construction. 4. At the time of submittal of the Final Site Plan review for the property, the Owner will map any jurisdictional wetland line on the site and establish a twenty-five (25) foot secondary buffer from that line. The usable area of the site will be reduced by this acreage and all development criteria will be reduced proportionately. Prior to or at the time of development of any portion of the property, if a Conservation and Drainage Easement is required, the Owner shall convey to the City the Conservation and Drainage Easement, the form of which shall be approved by the City prior to the conveyance. Section H. Commercial Proiects Intentionally deleted. Section L Single -Family Residential Projects Intentionally deleted. Page 14 of 15 Page 575 of 593 Section J. Townhome Projects Intentionally deleted. Section K. Wekiva Study Area 1. Intentionally Deleted Section L. West Orange Trail 1. Intentionally Deleted Page 15 of 15 Page 576 of 593