HomeMy WebLinkAboutItem 07 Approval of 2023-2024 Capital Improvement Project with Superior Sheds
City of Ocoee ▪ 1 N. Bluford Avenue ▪ Ocoee, Florida 34761
Phone: (407) 905-3100 ▪ www.ocoee.org
STAFF REPORT
Meeting Date: May 21, 2024
Item #: 7
Contact Name: Stephen Krug Department Director: Stephen Krug
Contact Number: Ext. 6002 City Manager: Robert Frank
Subject: Approval of 2023-2024 Capital Improvement Project with Superior Sheds. (Public
Works Director Krug)
Background Summary:
The approved budget for 2023/2024 includes a capital project for the construction of a prefabricated covered
metal shed at the Public Works complex. The structure would be used to protect the department's heavy
equipment from the elements. Public Works solicited pricing from Superior Sheds, our sole/single source
vendor for prefabricated sheds, to keep uniformity with the department's other similar existing structures.
Public Works reviewed the proposal and found the cost to be in line with current industry standards. Public
Works is requesting Commission approval to award the work to Superior Sheds, at their proposal cost of
$55,067.20.
Public Works recommends issuing a purchase order to Superior Sheds in the amount of $55,067.20, which is
adequately funded in the budget.
Issue:
Should the Honorable Mayor and City Commissioners approve issuing a purchase order to Superior Sheds for
the construction of a prefabricated covered metal shed at 301 Maguire Rd.?
Recommendations:
Staff recommends the Honorable Mayor and City Commissioners approve issuing a purchase order to
Superior Sheds in the amount of $55,067.20, and authorize the City Manager and staff to approve and
execute change orders to the work in accordance with the limits established in the Purchasing Code.
Attachments:
1. Superior Shed Proposal
2. Pole Barn - Engineering
3. Location
Financial Impacts:
The cost of the shed is adequately funded in the 2023/2024 Streets Division Capital Program for Public Works.
City of Ocoee ▪ 1 N. Bluford Avenue ▪ Ocoee, Florida 34761
Phone: (407) 905-3100 ▪ www.ocoee.org
Type of Item: Consent
2323 S. Volusia Avenue
Orange City, Florida 32763
877-439-7433
2-12-24
To: Craig Smith
City of Ocoee
407-905-3100 ext. 6015
30’ x 100’ x 20’ carport = $46,935 plus proof of tax exemption.
The roof will be vertical. The wind rating will be at the 150mph code.
The carport will have five 15’ x 15’ frame outs on one 100’ side.
Non-refundable site-specific engineering is at a cost of $650.
The nonrefundable site visit is at a cost of $150.
The additional mileage fee = $100.
The installation fee = $4732.20.
The cost to rent a lull – telescopic list is $2500.
The grand total = $55,067.20.
Purchase orders are accepted.
The Customer is required to provide level land or a level foundation. Steel does not come
with a floor.
Purchase may be made over the phone using a credit card.
Purchase orders need to be approved by the Manager of the steel division.
Give me a call if you have any question or are ready to place an order.
Connie Sibila
Corporate Office / Internet Sales Specialist
386-951-0224
ELEVATION NOTES
1. SEE CROSS SECTION FOR METHOD OF ROOF VENTILATION
2. HANDICAP RAMP(S), STAIRS, AND HANDRAILS ARE TO BE DESIGNED AND SITE
INSTALLED BY OTHERS, SUBJECT TO LOCAL JURISDICTION AND APPROVAL.
3. FOUNDATION ENCLOSURE ( WHEN PROVIDED ) MUST HAVE 1 SQUARE FOOT NET
VENT AREA PER 1/1 1/150TH OF THE FLOOR AREA, AND AN 18" X 24" MINIMUM
CRAWL SPACE ACCESS, SITE INSTALLED BY OTHERS, SUBJECT TO LOCAL
JURISDICTION AND APPROVAL.
GENERAL NOTES
1. ACCESS TO BUILDING FOR PERSONS IN WHEELCHAIRS IS DESIGNED BY AND FIELD BUILT
BY OTHERS AND SUBJECT TO ALL LOCAL JURISDICTIONS. AT LEAST 50% OF PUBLIC ENTRANCES
(INCLUDING PRIMARY ENTRANCE) AND ALL REQUIRED EXITS MUST BE ACCESSIBLE.
2. ALL DOORS SHALL BE OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY,
TOOL, SPECIAL KNOWLEDGE OR EFFORT. MANUALLY OPERATED FLUSH BOLTS OR SURFACE
BLOTS SHALL NOT BE USED.
3. ALL GLAZING WITHIN A 48 INCH ARC OF DOORS, WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES
ABOVE THE FLOOR, AND ALL GLAZING IN DOORS SHALL BE SAFETY, TEMPERED OR ACRYLIC PLASTIC
SHEET.
4. ALL STEEL STRAPS REFERENCED ON FLOOR PLAN SHALL BE 1.5 INCH X 26 GA. W/ (8) 15 GA. X 7/16
INCH CROWN X 1 1/2 INCH STAPLES WITH A MINIMUM OF 1" PENETRATION EACH END OF STRAP.
5. MIN. CORRIDOR WIDTH IS 44 INCHES.
6. MIN. CORRIDOR FINISH IS CLASS B (GYPSUM).
14. WINDOW AND DOOR HIGH WIND STORM COVERINGS PER CODE TO BE SUPPLIED AND SITE INSTALLED
BY OTHERS SUBJECT TO LOCAL JURISDICTION AND APPROVAL.
DESIGN WIND SPEED IS 140 MPH OR GREATER.
15. PLAN REVIEW AND INSPECTION REQUIRED BY CHAPTER 633 F.S. TO BE DONE BY THE LOCAL FIRE
SAFETY INSPECTOR.
7. IN WIND BORNE DEBRIS REGIONS, EXTERIOR GLAZING SHALL BE PROTECTED WITH AND IMPACT
RESISTANT COVERING OR WITH MINIMUM 7/16" WOOD STRUCTURAL PANELS PER SECTION 1609.1.2 OF
THE
PROVIDED PER TABLE 1609.1.2 THE IMPACT RESISTANT COVERING OR WOOD STRUCTURAL PANELS
ARE TO BE PROVIDED ON SITE BY OTHERS. SUBJECT TO LOCAL JURISDICTION AND APPROVAL.
WHERE THE ULTIMATE DESIGN WIND SPEED IS 130 MPH OR GREATER AND AREAS WHERE THE ULTIMATE
WIND BORNE DEBRIS REGIONS ARE AREAS WITHIN ONE MILE OF THE COASTAL MEAN HIGH WATER LINE
8. EMERGENCY LIGHTING SHALL BE CAPABLE OF PROVIDING INITIAL ILLUMINATION THAT IS AT LEAST AN
AVERAGE OF 1 FOOT-CANDLE AND A MIN. OF .1 FC MEASURED ALONG THE EGRESS AT THE FLOOR LEVEL.
ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO .6 C AVERAGE AND A MINIMUM AT ANY POINT
OF .06 FC AT THE END OF THE EMERGENCY LIGHT TIME DURATION. A MAXIMUM-TO-MINIMUM ILLUMINATION
UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED. THE EMERGENCY POWER SYSTEM
SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES.
FBC. PANELS SHALL BE PRECUT TO COVER THE GLAZED OPENINGS WITH ATTACHMENT HARDWARE
SITE INSTALLED NOTES
NOTE: THAT THIS LIST DOES NOT NECESSARILY LIMITS THE ITEMS OF WORK AND MATERIALS THAT MAY BE
REQUIRED FOR A COMPLETE INSTALLATION. ALL SITE RELATED ITEMS ARE RELATED ITEMS ARE SUBJECT
TO LOCAL JURISDICTION AND APPROVAL.
1. THE COMPLETE FOUNDATION SUPPORT AND TIE DOWN SYSTEM.
2. RAMPS, STAIRS AND GENERAL ACCESS TO THE BUILDING.
3. PORTABLE FIRE EXTINGUISHER(S).
4. DRINKING FOUNTAIN, BUILDING DRAINS, CLEAN-OUTS, AND HOOK-UP TO PLUMBING SYSTEM.
5. ELECTRICAL SERVICE HOOK-UP (INCLUDING FEEDERS) TO THE BUILDING.
6. THE MAIN ELECTRICAL PANEL AND SUB-FEEDERS (MULTI-UNITS ONLY).
7. CONNECTION OF ELECTRICAL CIRCUITS CROSSING OVER MODULE MATING LINE(S) - (MULTI-UNITS ONLY).
8. STRUCTURAL AND AESTHETIC INTERCONNECTIONS BETWEEN
9. WINDOW AND DOOR HIGH WIND STORM COVERINGS PER CODE.
10. GUTTERS AND DOWNSPOUTS (IF APPLICABLE).
11. SINK AND CABINETS.
12. FIRE ALARM SYSTEM, WIRING, ETC (IF APPLICABLE).
13. THERMAL EXPANSION DEVICE (IF REQUIRED).
STRUCTURAL LOAD LIMITATIONS
WIND LOAD CRITERIA
1.
2.
3.
136 Vult
I
II
WIND SPEED (MPH)
RISK CATEGORY
BUILDING CATEGORY
4.OPEN ENCLOSURE CLASSIFICATION
5.GCpl = 0.18 INTERNAL PRESSURE COEFFICIENT
6.C EXPOSURE FACTOR
7. 0.85
8. 0.85
WIND DIRECTIONALITY FACTOR (Kd)
GUST RESPONSE FACTOR (Gh)
9.Pr = -93.0 PSF MAIN FRAME STRUCTURE
OVERTURNING LOAD
11. THIS BUILDING IS NOT DESIGNED FOR PLACEMENT ON THE
UPPER HALF OF A HILL OR ESCARPMENT EXCEEDING 15 FEET
IN HEIGHT.
SEISMIC LOAD: N/A
10.
(ROOF)
COMPONENT & CLADDING LOAD
(WALL)
DRAWING INDEX
C1 COVER SHEET
A1 FLOOR PLAN
A2 ELEVATION PLAN
A3 TRUSS/ ROOFING DETAILS
A4 DETAILS
FLOOD LOAD:
THIS BUILDING IS NOT DESIGNED TO BE SUBMERGED OR
SUBJECTED TO WAVE ACTION WHEN LOCATED IN A FLOOD
PRONE OR ZONE AREA. FINISH FLOOR ELEVATION MUST BE
LOCATED ABOVE THE BUILDING SITE FLOOD PLANE LEVEL.
SHEDS LOCATED IN FLOOD HAZARD AREAS MUST COMPLY WITH
THE LOCAL FLOOD ZONE REGULATIONS.
Pr = ZONE 1: -29.82 PSF, ZONE 2: -42.26 PSF, ZONE 3: -59.64 PSF
PW = ZONE 4: +26.52 / -28.74 PSF, ZONE 5: +26.52 / -35.46 PSF
FLORIDA PRODUCT APPROVAL CHART
APPROVAL #MANUFACTURER VALIDATED BY STATUS
FL1763-R4 ADVANCED ALUMINUM BRIAN JAKS, P.E.APPROVED
CATEGORY: ROOFING
SUBCATEGORY: METAL ROOFING
(281) 468-0699
FL23138-R1 ADVANCED ALUMINUM BRIAN JAKS, P.E.APPROVED
CATEGORY: STRUCTURAL COMPONENTS
SUBCATEGORY: STRUCTURAL WALL
(281) 468-0699
FL23139-R1 ADVANCED ALUMINUM BRIAN JAKS, P.E.APPROVED
CATEGORY: STRUCTURAL COMPONENTS
SUBCATEGORY: ROOF DECK
(281) 468-0699
FL30315-R2 ADVANCED ALUMINUM MICHAEL JOHN RIEMER, P.E. APPROVED
CATEGORY: ROOFING
SUBCATEGORY: METAL ROOFING
(561) 414-7557
FL31736-R1 ADVANCED ALUMINUM APPROVED
CATEGORY: STRUCTURAL COMPONENTS
SUBCATEGORY: ROOF DECK
FL31737-R1 ADVANCED ALUMINUM APPROVED
CATEGORY: STRUCTURAL COMPONENTS
SUBCATEGORY: STRUCTURAL WALL
FL32151-R1 ADVANCED ALUMINUM APPROVED
CATEGORY: STRUCTURAL COMPONENTS
SUBCATEGORY: ROOF DECK
FL32152-R1 ADVANCED ALUMINUM APPROVED
CATEGORY: STRUCTURAL COMPONENTS
SUBCATEGORY: STRUCTURAL WALL
MICHAEL JOHN RIEMER, P.E.
(561) 414-7557
MICHAEL JOHN RIEMER, P.E.
(561) 414-7557
MICHAEL JOHN RIEMER, P.E.
(561) 414-7557
MICHAEL JOHN RIEMER, P.E.
(561) 414-7557
FL33569-R1 ADVANCED ALUMINUM APPROVED
CATEGORY: ROOFING
SUBCATEGORY: METAL ROOFING
MICHAEL JOHN RIEMER, P.E.
(561) 414-7557
FL17996.5 ELIXIR DOOR AND METAL COMPANY APPROVED
MODEL #: SERIES 407
FL21450-R6 JANUS INTERNATIONAL GROUP LLC.APPROVED
MODEL #: 850
C1TITLE:SUP108
E.ROM
DATE
DRAWNSUPERIOR SHEDS, INC..2323 S. VOLUSIA AVE.ORANGE CITY, FL 32763OFFICE: 813.996.7431www.superiorsheds.comJOB
SHEET NO.
BUILDING DROPS, INC.
1900 NE MIAMI COURT, UNIT 2-15
MIAMI, FL 33132
HERMES F. NORERO, P.E.
FLA. P.E. 3
SHOP DRAWING CHECKED FOR
STRUCTURAL REQUIREMENTS ONLY.PUBLIC WORKS FACILITY301 MAGUIRE ROADOCOEE, FL 34761THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY HERMES F.NORERO, P.E.
ON THE DATE AND/OR TIME STAMP SHOWN USING A DIGITAL SIGNATURE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND
SEALED AND THE SIGNATURES MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
SECTION SECURED WITH HEX
HEAD SCREW, #12-14x 1-1/4"
SELF DRILLING & TAPPING
FOR ALL FRAMING.
NOTES:
1. ALL HAT CHANNEL SHALL BE A MIN. 18 GA.
2. ALL STRUCTURAL TUBING SHALL BE A MIN. OF 14 GA.
3. ALL UNIVERSAL STEEL SHALL BE A MIN. OF 29 GA.
STRUCTURAL STEEL PANELS AND HAVE A YIELD
STRENGTH OF 80 KSI OR ANOTHER FBC APPROVED
PANEL.
18GA. ROOF PURLIN (TYP.)ROOF TRUSS CONT. FACTORY WELDED
INSERT IN MIDDLE SECTION.
BASE RAIL
2"x3"x20' LONG, (EXPANDABLE AT 4'
INCREMENTS) 14 GA. STEEL WITH
1-3/4"x2-3/4"x6" RAIL STACHIONS
WELDED AT 4' O.C. MAX.
ST
R
U
C
T
U
R
E
WI
D
T
H
ALL SIDE FRAMES
2"x3", 14 GA
PERFORMED STEEL
FLAT
BRACKET
(TYP.)
SECTION SECURED WITH HEX
HEAD SCREW, #12-14x 1 1/4"
SELF DRILLING & TAPPING
FOR ALL FRAMING.
ROOF PITCH VARIES
2/12 TO 4/12
3"2"
ANGLE
BRACKET
(TYP.)
(ALL FRAMING SHALL BE 2"x 3" RECTANGULAR TUBING)
ISOMETRIC MODEL
N.T.S.
NOTE: SEE SHEET A4 FOR ANCHORING DETAILS
(NOTE: ALL FRAMING SHALL BE 2"x 3" RECTANGULAR TUBING)
18 GA. GALVANIZED 2"x 2"
FASTENED TO 2"x 3" ROOF RAFTER
W/ SIMPSON STRONG TIE TP-15
AND (6) # 12-14 x 1-1/4" SDS
18 GA HAT CHANNEL ROOF PURLIN
GROUND ANCHOR TYPICAL (4'
O.C. MAX.) ONLY IF REQUIRED
(USED ON NON-CONC. FOOTINGS)
STRU
C
T
U
R
E
LEN
G
T
H
SIDE PURLINS ONLY USED WHEN
SIDING IS VERTICALLY INSTALLED
29 GA STEEL ROOF
(NOTE: WHEN OVER 26' IN WIDTH USE COLLAR TIE DETAIL
OR TRUSS DESIGN STYLE)
4'
O
.
C
.
(
T
Y
P
.
)
4' O.
C. (
M
A
X.)
PURLINS EVERY
48" MAX. ROOF
AND SIDES
2"x 3" 14 GA VERT COLUMN SPACED
EVENLY INSTALL OVER 1.75"x 2.75"x
6" 14 GA GALV. TUBING POST
SLEEVE
COLLAR TIE DETAIL AND POST BRACING DETAIL
2"x 2" 14 GA COLLAR TIE REQUIRED
FOR SPANS GREATER THAN 26'
PLACED 1/3 DOWN FROM PEAK
PURLIN SCREWS #12-14 x 1-1/4" AT 9" O.C. (TYP.)
COLUMN SCREWS #12-14 x 1-1/4"
SELF DRILLING SCREWS
12" INSERT 2.75"x 1.75" INTO
END OF BUILDING FRAMING
FASTEN W/ (2) #12-14x 1-1/4"
SDS (2) ON BUILDING SIDE (2)
ON LEAN TO SIDE
OPTION LEAN TO
14'-0 MAX SPAN
SEE SHEET A3
FOR TRUSS
CONFIGURATION VARIES4'-6" MAX.25'-0" MAX.EAVEHEIGHTSTRUCTURE
HEIGHT
N.T.S.
WINDOW INSTALLATION DETAIL
N.T.S.
DOOR INSTALLATION DETAIL
TYPICAL TRUSS CONNECTIONS
TYPICAL ROOF PURLIN ATTACHMENT
TYPICAL BOXED EAVE CONNECTION
2"x 3" TUBE SECURED TO LEGS
ABOVE DOOR W/ 2"x2" ANGLE
FASTENED TO LEGS W/(2) #12-14x 3/4"
SELF DRILLING SCREWS PER FACE
DOOR FRAME
2"x 3" TUBE SECURED TO HEADER AND
BOTTOM RAILING W/ 2"x 2" ANGLE
FASTENED TO LEGS W/ (2) #12-14x3/4"
SELF DRILLING SCREWS PER FACE
2"x 3" TUBE FOR LEGS SPACED
4' O.C. OR CLOSER (TYP)
2"x 3" TUBE SECURED TO HEADER AND
BOTTOM RAILING W/ 2"x 2" ANGLE
FASTENED TO LEGS W/ (2) #12-14x1-1/4"
SELF DRILLING SCREWS PER FACE
TRUSS TOP CHORD 3"x
2" HSS STEEL TUBING6'-10" +/-13-1/4"13-1/4"13-1/4"13-1/4"6"BOTTOM RAIL TO REMAIN
4'-0" MAX.
3'-4" +/-
BOTTOM RAIL TO REMAIN OR MAY BE
CUT OUT PER CUSTOMER REQUEST
6"
6"CONC. FOUNDATION
#12x2" SELF DRILLING
SCREW HEX HEAD (TYP)
2"x 3" TUBE FOR LEGS SPACED
4' O.C. OR CLOSER (TYP)
2"x 3" TUBE SECURED TO LEGS ABOVE
WINDOW W/ 2"x 2" ANGLE FASTENED
TO LEGS W/(2) #12-14x1-1/4" SELF
DRILLING SCREWS PER FACE
#12x 2" SELF DRILLING SCREW HEX
HEAD (TYP) FILL ALL MANF.
PRE-DRILLED HOLES
AFTER WINDOW INSTALLATION METAL
SIDING AND "J" CHANNEL WILL BE
ADDED TO MAKE WEATHER TIGHT
SUPPORT COLUMN 2"x 3"
HSS STEEL TUBING
(3) #12-14x 1-1/4" SELF
DRILLING SCREWS (TYP)
1-3/4"x 2-3/4"x 6" WELDING
INSERT HHS STEEL TUBING
2-1/2"x 1-1/2" 18 GA. HAT CHANNEL
ROOF PURLIN 48" O.C. (MAX)(TYP)
(2) #12-14x 1-1/4" SELF
DRILLING SCREWS (TYP)
TRUSS WEBING 3"x 2" HSS
STEEL TUBING
TRUSS TOP CHORD
3"x 2" HSS STEEL
TUBING
3/8"x 6"x 8" GALV. PLATE
CENTERED ABOUT JOINT
PLANE - WELDED ALL-AROUND
N.T.S.
FLOOR OPENING DETAIL (ONLY USED
WHEN FINISH FLOOR IS BELOW BFE)8"16"
REAR OF LOUVER COVERED
W/ WIRE MESH BUG SCREEN
FASTEN W/ (1) #12-14x 1-1/4"
SDS PER CORNER (TYP)
CODE REQUIREMENT 1 IN² PER FT² OF ENCLOSED BUILDING
TOTAL ENCLOSED BUILDING = 600 FT²
EQUIVALENT FLOOD OPENING = 192 IN² EA.
(25% REDUCTION DUE TO FINS) = 144 IN² EA.
TOTAL PROVIDED (5) = 720 IN²
4'-0" MAX.
A1
N.T.S.TITLE:SUP108
E.ROM
DATE
DRAWNSUPERIOR SHEDS, INC..2323 S. VOLUSIA AVE.ORANGE CITY, FL 32763OFFICE: 813.996.7431www.superiorsheds.comJOB
SHEET NO.
BUILDING DROPS, INC.
1900 NE MIAMI COURT, UNIT 2-15
MIAMI, FL 33132
HERMES F. NORERO, P.E.
FLA. P.E. 3
SHOP DRAWING CHECKED FOR
STRUCTURAL REQUIREMENTS ONLY.PUBLIC WORKS FACILITY301 MAGUIRE ROADOCOEE, FL 34761TRUSS VERTICAL CHORD
3"x 2" HSS STEEL TUBING
TRUSS WEBING 3"x 2"
HSS STEEL TUBING
1-3/4"x 2-3/4"x 24" WELDING
INSERT HSS STEEL TUBING
TRUSS BOTTOM CHORD
3"x 2" HSS STEEL TUBING
(3) 1/2-13 X 7-1/2" HEX BOLT
(3) 1/2-13
(6) Φ1/2" FLAT WASHER
TYPICAL TRUSS CONNECTION
39'-1" AND OVER 3/8"x 6"x 8" GALV. PLATE
WELDED ALL AROUND
N.T.S.
A2TITLE:SUP108
E.ROM
DATE
DRAWNSUPERIOR SHEDS, INC..2323 S. VOLUSIA AVE.ORANGE CITY, FL 32763OFFICE: 813.996.7431www.superiorsheds.comJOB
SHEET NO.
BUILDING DROPS, INC.
1900 NE MIAMI COURT, UNIT 2-15
MIAMI, FL 33132
HERMES F. NORERO, P.E.
FLA. P.E. 3
SHOP DRAWING CHECKED FOR
STRUCTURAL REQUIREMENTS ONLY.PUBLIC WORKS FACILITY301 MAGUIRE ROADOCOEE, FL 34761100'-0"
30'-0"
SITE-SPECIFIC DESIGN PLAN
SCALE 1 : 200
100'-0" (MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
RIGHT ELEVATION
N.T.S.
NOTE: SEE SHEET A4 FOR ANCHORING DETAILS
(NOTE: ALL FRAMING SHALL BE 2"X 3" RECTANGULAR TUBING)
2"X 3" 14GA HSS
STEEL BRACING
(TYP.)
2"X 3" 14GA HSS
STEEL BRACING
(TYP.)
SEE SISTER STUD
DETAIL ON
SHEET A5 ROOF (29 GA)
COLUMN LEG FROM BASE RAIL
TO HEADER - FASTEN INTO
FACTORY WELDED SLEEVE ON
BOTTOM OF TRUSS
5' O.C.
(MAX.)(TYP.)
FRONT OF
BUILDING
15'-0"
A.F.F.
15'-0"
A.F.F.
15'-0"
A.F.F.
15'-0"
A.F.F.
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
5'-0"
(MAX.)
15'-0"
FRAME
OUT
15'-0"
FRAME
OUT
15'-0"
FRAME
OUT
15'-0"
FRAME
OUT
15'-0"
FRAME
OUT
15'-0"
A.F.F.
100'-0" (MAX.)
LEFT ELEVATION
N.T.S.
NOTE: SEE SHEET A4 FOR ANCHORING DETAILS
(NOTE: ALL FRAMING SHALL BE 2"X 3" RECTANGULAR TUBING)
2"X 3" 14GA HSS
STEEL BRACING
(TYP.)
2"X 3" 14GA HSS
STEEL BRACING
(TYP.)
COLUMN LEG FROM BASE RAIL
TO HEADER - FASTEN INTO
FACTORY WELDED SLEEVE ON
BOTTOM OF TRUSS 5' O.C.
(MAX.)(TYP.)
ROOF (29 GA)
FRONT OF
BUILDING
SEE ROLL-UP DOOR JAMB
DETAIL ON SHEET A4
SEE ROLL-UP DOOR JAMB
DETAIL ON SHEET A4
SEE ROLL-UP DOOR JAMB
DETAIL ON SHEET A4
SEE ROLL-UP DOOR JAMB
DETAIL ON SHEET A4
SEE ROLL-UP DOOR JAMB
DETAIL ON SHEET A4
A3TITLE:SUP108
E.ROM
DATE
DRAWNSUPERIOR SHEDS, INC..2323 S. VOLUSIA AVE.ORANGE CITY, FL 32763OFFICE: 813.996.7431www.superiorsheds.comJOB
SHEET NO.
BUILDING DROPS, INC.
1900 NE MIAMI COURT, UNIT 2-15
MIAMI, FL 33132
HERMES F. NORERO, P.E.
FLA. P.E. 3
SHOP DRAWING CHECKED FOR
STRUCTURAL REQUIREMENTS ONLY.PUBLIC WORKS FACILITY301 MAGUIRE ROADOCOEE, FL 34761100'-0"
30'-0"
SITE-SPECIFIC DESIGN PLAN
SCALE 1 : 200
20'-0"
30'-0" (MAX.)
FRONT ELEVATION
N.T.S.
(SUPPORT WITH SIDING)
NOTE: SEE SHEET A4 FOR ANCHORING DETAILS
(NOTE: ALL FRAMING SHALL BE 2"X 3" RECTANGULAR TUBING)
25'-0"
(MAX.)
30'-0" (MAX.)
REAR ELEVATION
N.T.S.
(SUPPORT WITH SIDING)
NOTE: SEE SHEET A4 FOR ANCHORING DETAILS
(NOTE: ALL FRAMING SHALL BE 2"X 3" RECTANGULAR TUBING)
LEFT
SIDE
DESCRIPTION
FIELD LEADING EDGE
MAXIMUM UPLIFT DESIGN PRESSURE
FASTENER PATTERN
SUPPORT SPACING
ZONE 1 ZONE 2 ZONE 3
-29.82 -42.26 -59.64
6"- 3"- 6"- 3"- 6"
48" O.C.
9"- 9"- 9"- 9"
48" O.C.
N.T.S.
UNIVERSAL FASTENING SCHEDULE HORIZONTAL
ROOFING PANELS ACROSS TRUSS TOP CHORD
N.T.S.
UNIVERSAL FASTENING SCHEDULE SIDING
PANELS ACROSS SUPPORT COLUMNS
N.T.S.
UNIVERSAL FASTENING SCHEDULE VERTICAL
ROOFING PANELS ACROSS PURLINS
N.T.S.
TRUSS CONFIGURATIONS
N.T.S.
FIELD FASTENING PATTERN
N.T.S.
LEADING EDGE FASTENING PATTERN
#12-14x 7/8" SDS AND RUBBER
WASHER 1/2 PURLIN SPACING
ALONG PANEL LAP
FASTEN SHEATHING 9" O.C. FEILD W/ #12-14x
1-1/4" SDS AND RUBBER WASHER (TYP)
TRUSS TOP CHORD
4'-0" O.C. MAX (TYP)
OR CLOSER
#12-14x 1-1/4" SDS AND RUBBER WASHER
3"/6"/3" O.C. ALONG LEADING EDGE
FASTEN SHEATHING W/
#12-14x 1-1/4" SDS AND
RUBBER WASHER 9"
O.C. FIELD (TYP)
2"x 3" SUPPORT
COLUMN 4'-0" O.C. MAX
(TYP) OR CLOSER
FASTEN SHEATHING 9" O.C. FIELD
W/ #12-14x 1-1/4" SDS AND RUBBER
WASHERS (TYP)
2-1/2"x 1-1/2" HAT CHANNEL
ROOF PURLIN 48" O.C. (TYP)
2"x 3" TRUSS TOP
CHORD 4'-0" O.C. MAX
#12-14x 1-1/4" SDS AND
RUBBER WASER 3"/6"/3" O.C.
ALONG LEADING EDGE
ASTEN SHEATHING W/ #12-14x 7/8"
SDS AND RUBBER WASHER 1/2
PURLIN SPACING ALONG PANEL LAP
SIDELAP FASTENERS FIELD PANEL FASTENERS
#12-14x 7/8" SDS 1/2
TRUSS SPACING ON
CENTER ALONG PANEL
SIDELAP
#12-14x 1-1/4" SDS 9" ON
CENTER ALONG FIELD
TRUSS TOP CHORDS
GENERAL NOTES:
1.ALL CONCRETE WORK SHALL BE 3,000 P.S.I. AT 28 DAYS.
2. MINIMUM SOIL BEARING SHALL BE ASSUMED AT 2,000
P.S.F.
3. ALL CONSTRUCTION SHALL BE PROVIDED IN
ACCORDANCE WITH THE 2023 8TH EDITION FLA. BLDG.
CODE AND ASCE 7-22.
THESE PLANS INCLUDE DESIGN FOR ALL WIND
4.ALL SIDING AND ROOFING TO MINIMUM OF 26 GAUGE
ATTACHED TO THE COLUMNS AS SHOWN AND
CONSIDERED TO BE A MIN. OF 3 SPAN.
5.FOR ZONE LOCATIONS SEE FBC FIGURE 1609(C). THE
COMPONENTS AND CLADDING LOADING CHARTS THIS
SHEET.
6. DESIGN LOADINGS:
DEAD LOAD = 4 PSF
ROOF LIVE LOAD = 20 PSF
7.DOOR AND WINDOW DATA: PER TABLE
8.ALL WINDOWS AND MAN DOORS MAY USE #12-14x 1-1/4"
LONG SELF DRILLING SCREWS IN LIEU OF THE WOOD
SCREWS WHEN CONNECTING THE UNITS TO METAL FRAME.
FOLLOW THE MANUFACTURERS SPECIFICATIONS FOR
LOCATING CONNECTORS.
9. TYPE OF CONSTRUCTION: TYPE II-B
10. CORNER BRACES REQUIRED.
12
VARIES 212 TO 412
12
VARIES 212 TO 412
FASTEN SHEATHING 9" O.C. FIELD W/ #12-14x
1-1/4" SDS AND RUBBER WASHERS (TYP)
9"
2-1/2"x 1-1/2" HAT CHANNEL
ROOF PURLIN 48" O.C. (TYP)
2"x 3" TRUSS TOP
CHORD 4'-0" O.C. MAX
2"x 3" TRUSS TOP
CHORD 4'-0" O.C. MAX
#12-14x 1-1/4" SDS AND RUBBER WASHER
3"/6"/3" O.C. ALONG LEADING EDGE
2-1/2"x 1-1/2" HAT CHANNEL
ROOF PURLIN 48" O.C. (TYP)
WIND SPEED VS. LEG SPACING
AND CLADDING TABLE
DESIGN
VELOCITY
ULTIMATE
4' ON CENTER 5' ON CENTER
29 GA.160 MPH
29 GA.170 MPH
-150 MPH
--
29 GA.
-
-
-
WELDING TABLE
1/8
FILLET
1/8
1/8
1/8
SQUARE
BUTT
9" 9" 9"3"
6" 6" 6" 6"
3" 3" 3" 3"
A4
NOTE: ALL CONNECTIONS IN A 136 MPH WIND ZONE
WILL BE WELDED ALL AROUND CONNECTION
6"
-29 GA.175 MPH
VARIES 124 TO122
124 TO122VARIES
12
124 TO122VARIES
12
TITLE:SUP108
E.ROM
DATE
DRAWNSUPERIOR SHEDS, INC..2323 S. VOLUSIA AVE.ORANGE CITY, FL 32763OFFICE: 813.996.7431www.superiorsheds.comJOB
SHEET NO.
BUILDING DROPS, INC.
1900 NE MIAMI COURT, UNIT 2-15
MIAMI, FL 33132
HERMES F. NORERO, P.E.
FLA. P.E. 3
SHOP DRAWING CHECKED FOR
STRUCTURAL REQUIREMENTS ONLY.PUBLIC WORKS FACILITY301 MAGUIRE ROADOCOEE, FL 34761FROM 36'-1" THRU 39'-0"
BOXED EAVE
CONNECTION
(TYP)
TRUSS
CONNECTION
(TYP)
3/8"x 3"x 6" GALV. PLATE
WELDED ALL AROUND (TYP)
BOTH SIDES
12
212 TO 412VARIES
FROM 39'-1" THRU 60'-0"
BOXED EAVE
CONNECTION
(TYP)
TRUSS
CONNECTION
(TYP)
12
3/8"x 3"x 6" GALV. PLATE
WELDED ALL AROUND (TYP)
BOTH SIDES
FROM 26'-1" - THRU 30'-0"
BOXED EAVE
CONNECTION
(TYP)
TRUSS
CONNECTION
(TYP)
3/8"x 3"x 6" GALV. PLATE
WELDED ALL AROUND (TYP)
BOTH SIDES
FROM 22'-1" THRU 26'-0"
TRUSS
CONNECTION
(TYP.)
BOXED EAVE
CONNECTION
(TYP)
3/8"x 3"x 6" GALV. PLATE
WELDED ALL AROUND (TYP)
BOTH SIDES
FROM 30'-1" THRU 36'-0"
BOXED EAVE
CONNECTION
(TYP)
3/8"x 3"x 6" GALV. PLATE
WELDED ALL AROUND (TYP)
BOTH SIDES
TRUSS
CONNECTION
(TYP)
UP TO 22'-0"
BOXED EAVE
CONNECTION
(TYP)
SIMPSON STRONGTIE TP-15
TIE PLATE - FASTEN W/ (6)
#12-14x 1-1/4" SDS (BOTH ENDS)
TRUSS FOR GABLE END ONLY
UP TO 22'-0"
BOXED EAVE
CONNECTION
(TYP)
4 TO 12122VARIES
12
1" LENGTH 1/8" WELD
@ 6" O.C.
BOTH SIDES
LEG
RAIL
RAIL SLEEVE
NOTE: SISTER STUDS TO BE ADDED
@12'-0" AND HIGHER COLUMNS
3'-0" IN LENGTH SISTER STUD
WELDED TO MIDSPAN OF SUPPORT COLUMN
N.T.S.
SISTER STUD DETAILG
ROLL UP DOOR JAMB DETAILF
N.T.S.
N.T.S.
NEW CONCRETE/ DIRECT ANCHORING
N.T.S.
NEW CONCRETE/ OFFSET ANCHORING
2' x 3" SUPPORT COLUMN
4'-0" O.C. MAX (TYP)
1-3/4" x 2-3/4"x 6' SHOP
WELDED INSERT
OPTIONAL SIDING (TYP)
*1/2"x 6" TAPCONS W/ 2-3/4"
EMBEDMENT IS ALSO PERMITTED
*1/2"x 6" TAPCONS W/ 2-3/4"
EMBEDMENT IS ALSO PERMITTED
2"x 3"x 14 GA BASE RAIL W/ 1/2"x
5-1/2 WEDGE ANCHOR (1) WITHIN
12" OF EACH COLUMN IN FULLY
CURED 3000 PSI CONC.
2"x 3"x 14 GA BASE RAIL W/ 1/2"x
5-1/2 WEDGE ANCHOR (1) WITHIN
12" OF EACH COLUMN IN FULLY
CURED 3000 PSI CONC.
6"x 6" REINFORCING WIRE MESH
OR FIBER REINFORCEMENT (TYP)
(2)#5 BAR MIN 3" EMBEDMENT CONT. (TYP)
4" MIN. CONC. SLAB (3000 PSI)
OVER TERMITE TREATED SOIL
NOTE:
FIBER MESH CONCRETE CAN BE USED AS AN
ALTERNATIVE TO WWF REINFORCEMENT3"12"NOTE:
FIBER MESH CONCRETE CAN BE USED AS AN
ALTERNATIVE TO WWF REINFORCEMENT
6"x 6" REINFORCING WIRE MESH
OR FIBER REINFORCEMENT (TYP)
4" MIN. CONC. SLAB (3000 PSI)
OVER TERMITE TREATED SOIL
(2)#5 BAR MIN 3" EMBEDMENT CONT. (TYP)
1-3/4" x 2-3/4"x 6' SHOP
WELDED INSERT
ALTERNATE LOCATION MAY BE THROUGH THE
BASE RAIL 2" MIN. FROM EDGE OF CONC.
2' x 3" SUPPORT COLUMN
4'-0" O.C. MAX (TYP)
OPTIONAL SIDING (TYP)
1-3/4" x 2-3/4"x 6' SHOP
WELDED INSERT
3"12"12"
NOTE: ALL CONNECTIONS IN A 136 MPH WIND ZONE
WILL BE WELDED ALL AROUND THE CONNECTION
A5
SIMPSON STRONG TIE
W/ (6) #12-14x 1-1/4" SDS
TP-15 TIE PLATE FASTEN
2"x 3" HEADER
2"x 3" BASE RAIL
C SIMPLE JAMB CONNECTION
N.T.S.
2"x 3" HSS STEEL JAMB
1-3/4"x 2-3/4"x 12" WELDED INSERT
COLUMN
2"x 3" SUPPORT
2'x 3" BASE RAIL
SDS
(3) #12-14 x 1-1/4"
1/8
HSS 14 GA STEEL TUBING
A
CONNECTION (INTERIOR PERSPECTIVE)
SUPPORT COLUMN TO SIDE BASE RAIL
N.T.S.
SIMPSON STRONG TIE
N.T.S.
SIMPLE HEADER CONNECTIONE
2"x 3" SUPPORT COLUMN
2"x 3" HEADER
TP-15 TIE PLATE FASTEN
W/ (6) #12-14x 1-1/4" SDS
SIMPSON STRONG TIE S/H3
(FL10456.10-R3)
(4) #12-14x 1-1/4" SDS
HURRICANE TIE FASTEN W/
TUBINF CORNER BRACE
2"x 2" 15 GA HSS STEEL
2"x 3" BASE RAIL
2"x 3" SUPPORT COLUMN
D CORNER BRACE CONNECTION
N.T.S.
ANGLE TIE FASTEN W/
(FL10446.10-R4)
(4) #12-14x 1-1/4" SDS
SIMPSON STRONG TIE L30
2"x 3" TRUSS TOP CHORD
2"x 3" BASE RAIL
2"x 3" SUPPORT COLUMN
#12-14x 1-1/0 4" SDS
B
CONNECTION
GABLE COLUMN TO BASE RAIL
N.T.S.
EXISTING SLAB MAY BE USED ONLY WHEN SLAB IS IN SATISFACTORY
2"x 2"x 20 GA. STEEL ANGLE FASTENED
AUGER MUST BE RATED FOR AN ALLOWABLE PULL OUT RESISTANCE OF 500 LBS OR GREATER
AUGER SHALL BE UNDER SEPARATE APPROVAL. REFER TO MANUFACTURER'S PUBLISHED DATA
OR PRODUCT APPROVAL
WEDGE MUST BE RATED FOR AN ALLOWABLE PULL OUT RESISTANCE
OF 500 LBS OR GREATER
FIRST 10' AWAY FROM FOUNDATION (SECTION R401.3 2023 8TH EDITION FLA. BLDG. CODE)
WEDGE SHALL BE UNDER SEPARATE APPROVAL. REFER TO MANUFACTURER'S
PUBLISHED DATA OR PRODUCT APPROVAL
CONCRETE/DIRECT ANCHORING
FOUNDATION AND ANCHORING EXISTING
MIN. 4" THICK SLAB
3-1/4" MIN. EMBEDMENT
3-1/4" MIN. EMBEDMENT
WASHER ASSEMBLY (TYP)
1/2"x 4" THROUGH BOLT, NUT, AND
UNDISTURBED EARTH
ASPHALT AND BASE TO
CUT AND CORE EXISTING4'-0" O.C. MAX (TYP)
2' x 3" SUPPORT COLUMN
NATURAL GROUND EXISTING PAVEMENT
OPTIONAL SIDING (TYP)
OPTIONAL SIDING (TYP)
4'-0" O.C. MAX (TYP)
2' x 3" SUPPORT COLUMN SDS OR WELDED TO INSIDE FACE
TO 2"x 3" BASE RAIL W/ (2) #12-14x 1-1/4"
4'-0" O.C. MAX (TYP)
2' x 3" SUPPORT COLUMN
FOUNDATION CONTRACTOR TO PROVIDE FOR MINIMUM SLOPE OF 6" IN THE
MUST ACT AS A SINGLE SUPPORTING UNIT.
CONDITION; NO CRACKS/FISSURES, MINIMAL SLOPE/UNDULATIONS. SLAB
N.T.S.
EMBEDMENT
SUPPORT COLUMNS MIN. 24"
ANCHOR FASTEN WITH 12" OF
FLORIDA APPROVED 1/2"x 30" AUGER
12" OF EACH COLUMN
5-1/2 WEDGE ANCHOR (1) WITHIN
2"x 3"x 14 GA BASE RAIL W/ 1/2"x
NO FOUNDATION/BARE GROUND
N.T.S.
RAIL CONNECTION (EXTERIOR PERSPECTIVE)
N.T.S.
H SUPPORT DOUBLE COLUMN TO SIDE BASE
TITLE:SUP108
E.ROM
DATE
DRAWNSUPERIOR SHEDS, INC..2323 S. VOLUSIA AVE.ORANGE CITY, FL 32763OFFICE: 813.996.7431www.superiorsheds.comJOB
SHEET NO.
BUILDING DROPS, INC.
1900 NE MIAMI COURT, UNIT 2-15
MIAMI, FL 33132
HERMES F. NORERO, P.E.
FLA. P.E. 3
SHOP DRAWING CHECKED FOR
STRUCTURAL REQUIREMENTS ONLY.PUBLIC WORKS FACILITY301 MAGUIRE ROADOCOEE, FL 347616" LENGTH 1/4" WELD
@ 36" O/C
BOTH SIDES
DOOR SIDE
3'-0"
(TYP.)
2"x 3" SUPPORT
DOUBLE COLUMN
(2) 1-3/4"x 2-3/4"x 12"
WELDED INSERT
HSS 14 GA STEEL TUBING
2"x3"x 6" WELDED
CROSSBAR
2"x3"
BASE RAIL
2"x 3"x9" WELDED
TO BASE RAIL
1/8
(3) #12-14 x 1-1/4" SDS
ON EACH COLUMN
3'-6"