Loading...
HomeMy WebLinkAboutItem 06 Approval to Award to Bid (ITB) #26-001 Flewelling 2-Inch Water Main Replacement Project City of Ocoee ▪ 1 N. Bluford Avenue ▪ Ocoee, Florida 34761 Phone: (407) 905-3100 ▪ www.ocoee.org STAFF REPORT Meeting Date: December 2, 2025 Item #: 6 Contact Name: Alexis Chentouf, Joyce Tolbert Department Director: Steven Weber Contact Number: Ext. 3111, Ext. 1516 City Manager: Craig Shadrix Subject: Approval to Award to Bid (ITB) #26-001 Flewelling 2-Inch Water Main Replacement Project. (Procurement Manager Tolbert) Background Summary: The City of Ocoee solicited bids from qualified contractors for the installation of approximately 3,050 LF of 6” ductile iron water main and all associated valves, fittings, water services, stub- outs, fire hydrants, blow-offs, and connections to existing water mains. Additionally, the work includes the cutting, capping and abandoning in place of 2” galvanized steel water main. Surface restoration of all impacted facilities, including asphalt roadway trench repair, milling, resurfacing, and replacing asphalt, concrete sidewalk and curbing, driveways (concrete, stone, asphalt, pavers), striping, ADA ramps, sodding, landscaping, etc. Demolition, removal and re-connection of water services and meters. Deflection of existing or proposed utilities, testing, disinfection of new pipelines and dewatering as necessary for installation of new pipe and structures and all other work as shown in the Contract Drawings. The ITB was publicly advertised on October 5, 2025, and opened on November 4, 2025. There were a total of seven (7) bids received and all were deemed responsive. The bids ranged from $1,084,134.00 to $1,625,719.00 and are available in the finance department for review. Staff recommends awarding ITB #26- 001 Flewelling 2-Inch Water Main Replacement Project to the lowest bidder, Schuller Contractors Incorporated, for the total bid of $1,084,134.00 per the attached Award Recommendation from Utilities' Director Jen Bolling. Schuller Contractors Incorporated is currently part of the City's Small Construction Contract and has successfully completed other City Projects. This total bid comes in under the Engineer's Estimate of $1,700,000.00. Bidder Total Bid 1. Schuller Contractors Incorporated $1,084,134.00 2. J Malever Construction $1,200.615.00 3. EZ Contracting, LLC. $1,244,300.00 4. Prime Construction Group, Inc. $1,264,000.00 5. Clearwater Solutions, LLC. $1,289,176.56 6. Pabon Engineering, Inc. $1,549,500.00 7. Cathcart Construction Company — Florida, LLC. $1,625,719.00 City of Ocoee ▪ 1 N. Bluford Avenue ▪ Ocoee, Florida 34761 Phone: (407) 905-3100 ▪ www.ocoee.org Issue: Should the Honorable Mayor and City Commissioners award the bid for the Flewelling 2-Inch Water Main Replacement Project to Schuller Contractors, Incorporated? Recommendations: Staff recommends the Honorable Mayor & City Commissioners: 1. Award ITB #26-001 Flewelling 2-Inch Water Main Replacment Project to Schuller Contractors Incorporated for the amount of $1,084,134.00, and authorize the Mayor, City Clerk, and Staff to execute the required contract documents once the required bonds and insurance are received. 2. Authorize the City Manager to approve change orders to this contract up to the limit of his purchasing authority for each change order and up to the budgeted amount for this project for all change orders. Attachments: 1. Award Recommendation 2. Bid Tabulation 3. Invitation to Bid 4. Schuller Bid Package 5. Addendum 01 6. Addendum 02 7. Addendum 03 8. Addendum 04 9. Project Plans Financial Impacts: The Flewelling 2-Inch Water Main Replacement Project has been budgeted for a total amount of $1,567,075.00 from the Water Capital Improvements Carry Forward Fund (408-533-10-6302) in Job Number P000284. With the cost for design and construction management of the water main at $121,636.00, the available budget for construction is $1,445,439.00. Type of Item: Consent Mayor Rusty Johnson City Manager Craig Shadrix f I orl d a MEMORANDUM Commissioners Scott R. Kennedy, District l Rosemary Wilsen, District 2 Richard Firstner, District 3 George Oliver Ill, District 4 TO:Alexis Chentouf Purchasing Technician Through:Jennifer Bolling, P.L A Utilities Director�./ FROM:T'Jean Tomlinson, P.E. ':J � Engineering Manager DATE:Wednesday, November 19, 2025 RE:1TB #26-001 Flewelling 2-lnch Water Main Replacement Project Award Recommendation The Flewelling 2-lnch (a.k.a. Jay, Cardinal, and Orange) Water Main Replacement Project has budget available for Fiscal Year 2025-2026 for a total amount of $1,567,075.00 from the Water Capital Improvements Carry Forward Fund (408-533- 10-6302) in Job Number P000284. With the cost for design and construction management of the water main at $121,636.00, the available budget for construction is $1,445,439.00. The Utilities Department recommends awarding 1TB #26-001 Flewelling 2-lnch Water Main Replacement Project to the lowest responsive bidder for the base bid, Schuller Contractors Incorporated, in the amount of $1,084,134.00 based on the following: •On November 04, 2025, bids were opened for Bid 1TB #26-001 Flewelling 2- lnch Water Main Replacement Project. The three lowest bidders and their bid prices are listed below. l.Schuller Contractors Incorporated 9125 Parkers Landing, Suite 6 Orlando, FL 32824 Base Bid Price: $1,084, 134.00 2.J. Malever Construction Company 301 Sampey Road Groveland, FL 34736 Base Bid Price: $1,200,615.00 3.EZ Contracting, LLC. 5324 56th Commerce Park Boulevard City of Ocoee Utilities • 1800 A.D. Mims Road • Ocoee, Florida 347 61 Phone: ( 407) 905-3159 • www.ocoee.org/utilities ITB #26-001 FLEWELLING 2-INCH WATER MAIN REPLACEMENT PROJECT BID TABULATION 11/04/25 2:00 P.M. Acknowleged Addendum #1, 2, 3, & 4 Revised Questionaire Bid Security (Bid Bond) Company Verification/License Check Exceptions Required Forms DESCRIPTION QTY. UNIT PRICE TOTAL PRICE UNIT PRICE TOTAL PRICE UNIT PRICE TOTAL PRICE UNIT PRICE TOTAL PRICE Mobilization/Demobilization 1 $75,128.00 $75,128.00 $59,998.40 $59,998.40 $50,000.00 $50,000.00 $57,000.00 $57,000.00 General Requirements, Bonds, and Permits 1 $92,870.00 $92,870.00 $28,332.23 $28,332.23 $20,000.00 $20,000.00 $18,000.00 $18,000.00 Maintenance of Traffic 1 $18,520.00 $18,520.00 $28,720.10 $28,720.10 $25,000.00 $25,000.00 $80,000.00 $80,000.00 Erosion Control 1 $27,210.00 $27,210.00 $13,881.17 $13,881.17 $20,000.00 $20,000.00 $5,000.00 $5,000.00 Construction Photographs and Audio - Visual Recording 1 $8,750.00 $8,750.00 $5,078.30 $5,078.30 $10,000.00 $10,000.00 $5,000.00 $5,000.00 Survery (Horizontal and Vertical Controls & As- Builts)1 $31,406.00 $31,406.00 $17,485.02 $17,485.02 $20,000.00 $20,000.00 $40,000.00 $40,000.00 Cut and Cap Exsisting 2" Galvanized Steel Water Main in Place 6 $1,780.00 $10,680.00 $2,404.21 $14,425.26 $15,000.00 $90,000.00 $2,000.00 $12,000.00 Removal and Disposal of 6" PVC Water Main 25 $60.00 $1,500.00 $198.78 $4,969.50 $100.00 $2,500.00 $60.00 $1,500.00 Furnish and Install 6" Dia. DI Water Main 3,050 $185.00 $564,250.00 $134.22 $409,371.00 $150.00 $457,500.00 $125.00 $381,250.00 Connections to 6" Dia. PVC and DI Water Main 1 $19,257.00 $19,257.00 $35,760.06 $35,760.06 $30,000.00 $30,000.00 $20,000.00 $20,000.00 6" Gate Valve and Box 11 $3,638.00 $40,018.00 $3,699.97 $40,699.67 $8,000.00 $88,000.00 $2,750.00 $30,250.00 General D.I. Fittings 0.5 $15,870.00 $7,935.00 $43,772.78 $21,886.39 $5,500.00 $2,750.00 $12,000.00 $6,000.00 6" Insertion Valve 2 $18,420.00 $36,840.00 $19,644.81 $39,289.62 $25,000.00 $50,000.00 $13,000.00 $26,000.00 Fire Hydrant Assembly 6 $11,814.00 $70,884.00 $7,529.47 $45,176.82 $4,500.00 $27,000.00 $8,000.00 $48,000.00 Double 1" P.E. Service 16 $4,419.00 $70,704.00 $2,451.34 $39,221.44 $2,500.00 $40,000.00 $4,000.00 $64,000.00 Single 1" P.E. Service 25 $3,876.00 $96,900.00 $2,138.97 $53,474.25 $2,000.00 $50,000.00 $3,500.00 $87,500.00 6" x 6" Tapping Sleeve and Valve 2 $9,477.00 $18,954.00 $14,057.26 $28,114.52 $20,000.00 $40,000.00 $6,000.00 $12,000.00 Remove and Replace Concrete Sidewalk 4" Thick 193 $175.00 $33,775.00 $216.06 $41,699.58 $100.00 $19,300.00 $200.00 $38,600.00 Remove and Replace Concrete Driveways 6" Thick 308 $180.00 $55,440.00 $201.25 $61,985.00 $150.00 $46,200.00 $225.00 $69,300.00 Remove and Replace Driveways (Non-Concrete) 261 $125.00 $32,625.00 $187.22 $48,864.42 $50.00 $13,050.00 $65.00 $16,965.00 Removal and Disposal of Exsisting Fire Hydrants 1 $4,777.00 $4,777.00 $3,865.60 $3,865.60 $3,000.00 $3,000.00 $1,750.00 $1,750.00 Removal and Replacement of Asphalt 500 $181.00 $90,500.00 $165.69 $82,845.00 $200.00 $100,000.00 $105.00 $52,500.00 General Restoration 1 $202,759.00 $202,759.00 $128,130.24 $128,130.24 $20,000.00 $20,000.00 $113,000.00 $113,000.00 Utility Coordination 1 $14,037.00 $14,037.00 $35,905.97 $35,905.97 $20,000.00 $20,000.00 $15,000.00 $15,000.00 TOTAL BASE BID $1,625,719.00 $1,289,179.56 $1,244,300.00 $1,200,615.00$444.00 *License check, submitted forms & references verified only on lowest three firms. *Bidders listed in alphabetical order *Yellow highlighted amounts represent discrepancies on the Bid Form *Missing forms are considered a minor irregularity. BID TABULATION  Cathcart Construction Company - Florida, LLC.J Malever Construction EZ Contracting, LLC.  Active Bid Bond Bid Bond Clearwater Solutions, LLC. Active 23 No No   1 ITB #26-001 FLEWELLING 2-INCH WATER MAIN REPLACEMENT PROJECT BID TABULATION 11/04/25 2:00 P.M. Acknowleged Addendum #1, 2, 3, & 4 Revised Questionaire Bid Security (Bid Bond) Company Verification/License Check Exceptions Required Forms DESCRIPTION QTY. Mobilization/Demobilization 1 General Requirements, Bonds, and Permits 1 Maintenance of Traffic 1 Erosion Control 1 Construction Photographs and Audio - Visual Recording 1 Survery (Horizontal and Vertical Controls & As- Builts)1 Cut and Cap Exsisting 2" Galvanized Steel Water Main in Place 6 Removal and Disposal of 6" PVC Water Main 25 Furnish and Install 6" Dia. DI Water Main 3,050 Connections to 6" Dia. PVC and DI Water Main 1 6" Gate Valve and Box 11 General D.I. Fittings 0.5 6" Insertion Valve 2 Fire Hydrant Assembly 6 Double 1" P.E. Service 16 Single 1" P.E. Service 25 6" x 6" Tapping Sleeve and Valve 2 Remove and Replace Concrete Sidewalk 4" Thick 193 Remove and Replace Concrete Driveways 6" Thick 308 Remove and Replace Driveways (Non-Concrete) 261 Removal and Disposal of Exsisting Fire Hydrants 1 Removal and Replacement of Asphalt 500 General Restoration 1 Utility Coordination 1 TOTAL BASE BID *License check, submitted forms & references verified only on lowest three firms. *Bidders listed in alphabetical order *Yellow highlighted amounts represent discrepancies on the Bid Form *Missing forms are considered a minor irregularity. BID TABULATION UNIT PRICE TOTAL PRICE UNIT PRICE TOTAL PRICE UNIT PRICE TOTAL PRICE $77,000.00 $77,000.00 $62,500.00 $62,500.00 $51,000.00 $51,000.00 $52,500.00 $52,500.00 $34,720.00 $34,720.00 $36,906.00 $36,906.00 $45,700.00 $45,700.00 $25,000.00 $25,000.00 $36,000.00 $36,000.00 $3,260.00 $3,260.00 $15,000.00 $15,000.00 $10,800.00 $10,800.00 $10,500.00 $10,500.00 $2,500.00 $2,500.00 $5,000.00 $5,000.00 $25,000.00 $25,000.00 $25,000.00 $25,000.00 $21,660.00 $21,660.00 $3,600.00 $21,600.00 $600.00 $3,600.00 $1,500.00 $9,000.00 $100.00 $2,500.00 $40.00 $1,000.00 $100.00 $2,500.00 $240.00 $732,000.00 $198.00 $603,900.00 $130.00 $396,500.00 $25,000.00 $25,000.00 $35,000.00 $35,000.00 $10,000.00 $10,000.00 $5,000.00 $55,000.00 $2,800.00 $30,800.00 $3,000.00 $33,000.00 $12,000.00 $6,000.00 $12,000.00 $6,000.00 $21,600.00 $10,800.00 $12,500.00 $25,000.00 $5,500.00 $11,000.00 $17,400.00 $34,800.00 $8,800.00 $52,800.00 $12,000.00 $72,000.00 $10,000.00 $60,000.00 $4,650.00 $74,400.00 $2,800.00 $44,800.00 $3,431.00 $54,896.00 $4,450.00 $111,250.00 $2,600.00 $65,000.00 $2,045.00 $51,125.00 $14,000.00 $28,000.00 $8,700.00 $17,400.00 $9,800.00 $19,600.00 $165.00 $31,845.00 $140.00 $27,020.00 $120.00 $23,160.00 $190.00 $58,520.00 $190.00 $58,520.00 $150.00 $46,200.00 $125.00 $32,625.00 $40.00 $10,440.00 $120.00 $31,320.00 $3,000.00 $3,000.00 $2,800.00 $2,800.00 $3,600.00 $3,600.00 $78.00 $39,000.00 $90.00 $45,000.00 $180.00 $90,000.00 $35,000.00 $35,000.00 $60,000.00 $60,000.00 $40,267.00 $40,267.00 $2,000.00 $2,000.00 $5,000.00 $5,000.00 $6,000.00 $6,000.00 $1,549,500.00 $1,264,000.00 $1,084,134.00  1 Schuller Contractors Incorporated   Bid Bond Active No Pabon Engineering, Inc. Prime Construction Group, Inc. 2 SECTION 00020 INVITATION TO BID Flewelling 2-Inch Water Main Replacement Project ITB #26-001 00020-1 ITB #26-001 Flewelling 2-Inch Water Main Replacement Project The City of Ocoee, Florida (“City”, “Owner”) is soliciting sealed Bids for the Project ITB #26-001 Flewelling 2-Inch Water Main Replacement Project. Description of Work: All Work for the Project shall be constructed in accordance with the drawings and specifications and the Contact Documents prepared by Hazen and the City of Ocoee Utilities Department. The proposed project will be awarded and constructed, in conformance with the plans, specifications, and City of Ocoee Engineering Standards Manual. Bids shall be deemed to include all items necessary for the furnishing, delivering, and installing of all materials, equipment, incidentals, and services, including all labor for the work which is generally described as the following: A. The Project consists of the installation of approximately 3,050 LF of 6” ductile iron water main and all associated valves, fittings, water services, stub-outs, fire hydrants, blow-offs, and connections to existing water mains. Additionally, the work includes the cutting, capping and abandoning in place of 2” galvanized steel water main. Surface restoration of all impacted facilities, including asphalt roadway trench repair, milling, resurfacing, and replacing asphalt, concrete sidewalk and curbing, driveways (concrete, stone, asphalt, pavers), striping, ADA ramps, sodding, landscaping, etc. Demolition, removal and reconnection of water services and meters. Deflection of existing or proposed utilities, testing, disinfection of new pipelines and dewatering as necessary for installation of new pipe and structures and all other work as shown in the Contract Drawings. B. All work must be in compliance with the City of Ocoee Engineering Standards Manual. See Section 02100. All work activities shall be required to be in accordance with the permits issued by the respective agencies. All work performed will be required to be done while maintaining the functional operation of the existing reclaim mains. The City is ONLY accepting electronic solicitation responses online through the City’s Euna Procurement platform at https://ocoee.bonfirehub.com. This link can also be accessed through the City’s website at https://www.ocoee.org/323/Purchasing under the Current Open Solicitations menu. All Bid submissions for this ITB MUST be submitted electronically through the Euna Procurement Platform. Bid submissions received in any other format will not be accepted; no paper, fax, or e-mailed submissions will be accepted. There is no charge for bidders to use the Euna e-procurement Flewelling 2-Inch Water Main Replacement Project ITB #26-001 00020-2 platform. Euna Procurement platform’s minimum system requirements: Microsoft Edge, Google Chrome, Safari, or Mozilla Firefox. JavaScript and browser cookies must be enabled. Registration with Euna Procurement is free and is required prior to submitting a bid. It is suggested that prospective bidders register no later than 24 hours in advance of the bid submission deadline to ensure proper registration. Should a Bidder need assistance with registering, please contact the Euna Procurement formally known as Bonfire, Support Desk by emailing support@gobonfire.com. Support by email is provided Monday to Friday from 8:00 a.m. – 8:00 p.m. EST/EDT. Upon completing the registration with Euna Procurement, bidders will be able to submit a bid securely, any time before the bid submission deadline, at https://ocoee.bonfirehub.com by clicking the “PREPARE YOUR SUBMISSION” under the solicitation. An instructional video is provided for an overview of the submission process. Once the bid has been submitted, the Bidder will receive a date/time stamp confirmation within the Euna Procurement platform and an email confirmation of the bid submission. Bids submitted on the Euna Procurement Platform will remain locked and inaccessible by City staff until the bid deadline. Bidders are encouraged to allow ample time to upload and submit their Bid as the system will automatically lock upon the bid submission deadline. The actual contract award will be made by the Ocoee City Commission at a later date. Please be aware that all City Commission meetings are duly noticed public meetings and all documents submitted to the City as a part of a bid constitute public records under Florida law. Bid Submission Deadline: Bids will only be accepted electronically through the Euna Procurement Platform until 2:00 p.m., local time, on November 4, 2025. Bidders shall submit one (1) complete electronic copy, preferably in a single file, of their Bid on the Bonfire Platform. Bids must be received by Bonfire no later than the bid submission deadline. It shall be the sole responsibility of the Bidder to have its Bid uploaded and submitted on the Bonfire Platform prior to the due date and time. Any attempt to submit a bid after the submission deadline will not be accepted under any circumstances. Any uncertainty regarding the time a bid is received will be resolved against the Bidder. A virtual public bid opening will be held at approximately 2:01 pm. or as soon thereafter. Once available, the details on how to access the virtual bid opening will be posted in the project file on Euna Procurement and available on the City’s website at https://www.ocoee.org/959/Public-Bid-Meetings. Deadline for Receipt of Questions: The City will receive questions regarding this ITB only through written inquires directed to Alexis Chentouf, Purchasing Technician at achentouf@ocoee.org OR through the questions and answer section of the project file on Euna Procurement until October 28, 2025 at 2:00 p.m., local time. Any clarifications/changes will be made by way of written addenda only, issued by Purchasing and posted on Euna Procurement. Bidders should not contact City staff, with the exception of the Purchasing Technician, or other City consultants for information regarding this ITB before the Bid award date. Any contact with any other member of City Staff, City Commission, or its agents during the solicitation, award, and protest period may be grounds for disqualification. Flewelling 2-Inch Water Main Replacement Project ITB #26-001 00020-3 Pre-Bid Conference: A non-mandatory pre-bid conference is scheduled for 10:00 a.m. local time on a Tuesday, October 21, 2025, at the City of Ocoee Commissions Chambers, 1 N. Bluford Ave, Ocoee, FL 34761. Bid Bond: A certified check or bid bond shall accompany each Bid. The certified check or bid bond shall be for an amount not less than five percent (5%) of the bid price, and shall be made payable to the City of Ocoee as a guarantee that the Bidder will not withdraw for a period of ninety (90) days after bid closing time. A copy of the bid security is to be included with the bid submitted electronically Bonfire. The original bid security is to be mailed within five (5) business days after the bid opening to: City of Ocoee, Finance Department/Purchasing, Attention: Alexis Chentouf, Purchasing Technician, 1 N. Bluford Avenue, Ocoee, FL 34761. Failure to provide the original will cause your bid to be deemed non-responsive. Convicted Vendor List (Public Entity Crime). A person or affiliate who has been placed on the convicted vendor list following a conviction for a public entity crime may not submit a Bid on an award to provide any goods or services to a public entity, may not submit a bid on an award with a public entity for the construction or repair of a public building or public work, may not submit bids on leases of real property to a public entity, may not be awarded or perform work as a Contractor, Supplier, Subcontractor, or Consultant under a award with any public entity, and may not transact business with any public entity in excess of the threshold amount provided in section 287.017 for Category Two for a period of 36 months from the date of being placed on the convicted vendor list. [See s. 287.133(2)(a), Florida Statutes.] Florida Public Records Law. In accordance with Chapter 119, Florida Statutes, and, except as may be provided by Chapter 119, Florida Statutes, and other applicable State and Federal Laws, all Bidders should be aware that the Bid and the responses thereto are in the public domain and are available for public inspection. Bidders are requested, however, to identify specifically any information contained in their bids that they consider confidential and/or proprietary and that they believe to be exempt from disclosure, citing specifically the applicable exempting law. All bids received in response to this Invitation to Bid become the property of the City and will not be returned. In the event of an award, all documentation produced as part of the contract will become the exclusive property of the City. Prohibition Against Considering Social, Political or Ideological Interests in Government Contracting: Bidders are hereby notified of the provisions of section 287.05701, Florida Statutes, as amended, that the City will not request documentation of or consider a Bidder's social, political, or ideological interests when determining if the Bidder is a responsible Bidder. Bidders are further notified that the City's governing body may not give preference to a Bidder based on the Bidder's social, political, or ideological interests. The City reserves the right to accept or reject any or all bids, to waive formalities, technicalities or irregularities, to request clarification of information submitted in any bid, or to re-advertise for new bids. The City may accept any item or group of items of any bid, unless the Bidder qualifies its bid by specific limitations. The City may accept one or more bids if, in the City’s discretion, the City determines that it is in the City’s best interest to do so. Flewelling 2-Inch Water Main Replacement Project ITB #26-001 00020-4 The City reserves the right to award the contract to the Bidder which, in the City’s sole discretion, is the most responsive and responsible Bidder. The City reserves the right, as an aid in determining which bid is responsible, to require a bidder to submit such additional evidence of Bidder’s qualifications as the City may deem necessary, and may consider any evidence available to the City of the financial, technical, and other qualifications and abilities of a Bidder, including past performance (experience) with the City and others. The City Commission shall be the final authority in the selection of any and all bids. END OF SECTION Mayor Commissioners Rusty Johnson Scott R. Kennedy, District 1 Rosemary Wilsen, District 2 City Manager Richard Firstner, District 3 Craig Shadrix George Oliver III, District 4 Addendum No.1 ITB #26-001 Flewelling 2-Inch Water Main Replacement Project Page 1 October 20, 2025 ADDENDUM NO. ONE (1) CITY OF OCOEE ITB #26-001 Flewelling 2-Inch Water Main Replacement Project This addendum shall modify and become a part of the original ITB Documents for ITB #26-001. This addendum consists of two (2) pages. Bidders should acknowledge receipt of this addendum in the space provided in the Bid Form. Failure to do so may subject the Bidder to disqualification. Answers to questions received and/or Amendments to the ITB Documents are as follows 1. Questions / Answers Q1. Is there a geotechnical report available for this project? A1. No. Q2. Does the city have a preferred method for the trenchless construction. Is pneumatic boring (Missile) acceptable or is directional drilling preferred? A2. The DIP water main installation method is by open cut only. Long services shall be installed by horizontal directional drill; the City does not permit the use of the missile method, as previous projects have experienced repeated issues with missiles becoming stuck beneath the roadway. Short services shall be installed by open cut. Q3. Is bedding required for the DI pipe? A3. It is not normally required for laying ductile iron pipe unless conditions are wet. It will be required for all areas dictated on the plans and specifications such as TEEs, hydrants, etc. Continue to Next Page Addendum No. 1 ITB #25-001 Transmission Main Interconnect to Orange County Utilities RCW System ARPA Project Page 2 Q4. In spec section 00100-9 12.12. the written value of the capped mobilization value is five percent, but the numeric valve is 4%. Section 1505-3 has it at 5%. Please clarify what is the capped value of the mobilization value for this project. A4. The mobilization is five percent (5%). Alexis Chentouf Alexis Chentouf Purchasing Technician cc: Jen Bolling, Utilities Director Mayor Commissioners Rusty Johnson Scott R. Kennedy, District 1 Rosemary Wilsen, District 2 City Manager Richard Firstner, District 3 Craig Shadrix George Oliver III, District 4 Addendum No.2 ITB #26-001 Flewelling 2-Inch Water Main Replacement Project Page 1 October 27, 2025 ADDENDUM NO. TWO (2) CITY OF OCOEE ITB #26-001 Flewelling 2-Inch Water Main Replacement Project This addendum shall modify and become a part of the original ITB Documents for ITB #26-001. This addendum consists of eight (8) pages. Bidders should acknowledge receipt of this addendum in the space provided in the Bid Form. Failure to do so may subject the Bidder to disqualification. Answers to questions received and/or Amendments to the ITB Documents are as follows 1.Questions / Answers Q1. Is there any property near the job that can be used for Lay down yard? A1. It will be the Contractor’s responsibility to find and secure a Lay Down Yard but the City will be open to the Contractor using the areas circled in red on the attachment below. This will be decided during the Pre-Construction Meeting. Q2. Is the city assuming responsibility for the meter connections? A2. The Contractor will be responsible for meter connections to the re-routed water services lines from the homes. Q3. What is the engineer's estimate for the scope of work on this project? A3. Approximately $1,700,000.00 Q4. Section 1001-34 has the contractor providing a furnished trailer for the exclusive use of the engineer. Please clarify if this is a requirement for this project. A4. Owner/Engineer’s field office is not required. Addendum No. 2 ITB #26-001 Flewelling 2-Inch Water Main Replacement Project Page 2 Q5. With the existing waterline located in the back property line. Who will be responsible to connect the new water service built during this project which will be located at the roadway R/W to the house's existing service located in the backyard / along the back property line? If this is done by others / residents will it be required to be done during the 270 construction days? If all the residents are not connected by that date will the contractor be responsible / compensated to come back and cap the back yard main service line once all the residents are connected in the block? A5. The City will be reaching out to plumbers to re-route the services from the back of the homes to the front at the point of connection for the new services. Q6. In section 500-6 - 7.9 The contractor shall perform work with a value not less than 30% of the contract value but in section 200-23 - 9 It says No more than 30% of the dollar value of the total bid for the work shall be performed by subcontractors. What is the % of the contract value that can be done by the prime contractor and all other subcontractors? A6. No more than 30% of the work shall be performed by subcontractors. Q7. In the questionnaire section page 301-18 it references contractors license number and how many years has your organization been in business as a general contractor? This type of project should allow for the use of a underground contractors license or a general contractor license be meet the license requirement of the prime contractor. Will a underground contractor license number and years of experience be acceptable on this questionnaire for this job? A7. Yes, the requirement shall be open to firms holding either an Underground Contractor’s License or a General Contractor’s License. Please refer to the revised Questionnaire form attached. Q8. Is trenchless required or can long services be done by open trench? A8. Trenchless is required for long services. Please see the answer on Addendum 1 for Q2 for more information. Q9. Does the City require project name, contract no., description, etc with the municipalities? A9. Yes. Q10. Who is responsible for landscaping and paver restoration? Will there be any storing or palletization? Page Continues Addendum No. 2 ITB #26-001 Flewelling 2-Inch Water Main Replacement Project Page 3 A10. The City does not require the Contractor to replace pavers removed in the ROW that conflict with construction nor does the City require the Contractor to restore landscaping planted by the resident in the City’s ROW that is within the path of construction. Material outside of the City’s ROW on the resident’s private property that is damaged by the Contractor will be the responsibility of the Contractor to repair/replace and any disputes shall be between the Contractor and the resident. Prior to Construction, the City will send Project Introduction Letters to residents regarding the removal and stockpiling of landscaping and pavers. It will be the resident’s responsibility to coordinate with the City regarding what will be kept and the stockpile location for the resident to re-install after the project. The Contractor shall take the upmost care in removing landscaping and pavers to be stockpiled as to not damage the material. Q11. For the project below 2 Insertion Valves are called out but I did not notice the manufacturer for these valves in the bid docs. What are the acceptable manufacturers for insertion valves for the City of Ocoee? A11. The City has used the Manufacturer Hydra-Stop for the Insertion Valves in recent projects. Q12. Will the contractor be able to have a daily flagging lane closure to install the pipe? A12. The contractor can have a one lane flagging operation to install the pipe. All TTC and site safety is the responsibility of the contractor. Any TTC set ups must be submitted with a timeline, reviewed, and approved by City Staff in advance of the work proposed. Q13. Will the contractor be able to close Center St with a detour to make each of the 3 connections to the existing waterline and do the road crossing on Center Street. A separate closure and detour would be used for the mill & repave operation at the 3 connection points A13. The City would consider a road closure on Center St to make the connections and repairs. Again, all TTC and site safety is the responsibility of the contractor. Any TTC set ups must be submitted with a timeline, reviewed, and approved by City Staff in advance of the work proposed. Q14. Does this project have any BABA or AIS requirements that requires the contractor to have to buy American made materials? A14. No, as this project is not State or Federal funded. Addendum No. 2 ITB #26-001 Flewelling 2-Inch Water Main Replacement Project Page 4 2. Section 00300 – Questionnaire • The revised Section 00300 will be attached to this addendum 3. Marked Plans for Approved Lay Down Areas • The marked drawings will be attached to this addendum. Alexis Chentouf Alexis Chentouf Purchasing Technician cc: Jen Bolling, Utilities Director Attachments: Questionnaire Marked Plans for Approved Lay Down Areas Flewelling 2-Inch Water Main Replacement Project ITB #26-001 00301-1 SECTION 00301 QUESTIONNAIRE Bidder shall fill out questionnaire form with all information pertinent to his/her company and the Flewelling 2-Inch Water Main Replacement Project. DATE: PROJECT IDENTIFICATION: City of Ocoee ITB #26-001 Flewelling 2-Inch Water Main Replacement Project NAME OF BIDDER: BUSINESS ADDRESS: TELEPHONE NO.: EMAIL CONTRACTOR'S FLORIDA LICENSE NO. The undersigned warrants the truth and accuracy of all statements and answers herein contained. Include additional sheets if necessary. 1. How many years has your organization been in business as a General/Underground Contractor? 2. Describe and give the date and owner of the last project the Bidder has completed, similar in type, size, and nature as the one proposed? 3. Has the Bidder ever failed to complete work awarded to you? If so, where, and why? 4. Name three (3) municipalities for which the Bidder has performed similar work and contact person: Flewelling 2-Inch Water Main Replacement Project ITB #26-001 00301-2 5. Has the Bidder personally inspected the site of the proposed Work? Describe any anticipated problems with the site and the proposed solutions? 6. Will the Bidder Subcontract any part of this Work? If so, describe which portions and the percentage of the project: 7. What equipment does the Bidder plan on using to complete the Work? 8. State the true and exact, correct, and complete name under which the Bidder does business. Bidder is: Page Continues Flewelling 2-Inch Water Main Replacement Project ITB #26-001 00301-3 9. Does the Bidder have any Exceptions to the terms of the Contract Documents? Yes No List any exceptions Bidder has to this scope of work or contract terms. (Note: Exceptions will not be considered after the bid has been awarded). The City reserves the right to accept or reject any requested exceptions. Please reference Section 100; Article 4.7, for further clarification. Note if Bidder leaves this question blank, Bidder agrees it has no exceptions. END OF SECTION Mayor Commissioners Rusty Johnson Scott R. Kennedy, District 1 Rosemary Wilsen, District 2 City Manager Richard Firstner, District 3 Craig Shadrix George Oliver III, District 4 Addendum No. 3 - ITB #26-001 Flewelling 2-Inch Water Main Replacement Project October 30, 2025 ADDENDUM NO. THREE (3) CITY OF OCOEE ITB #26-001 Flewelling 2-Inch Water Main Replacement Project This addendum shall modify and become a part of the original ITB Documents. This addendum consists of one (1) page. Bidders should acknowledge receipt of this addendum in the space provided in the Bid Form. Failure to do so may subject the Bidder to disqualification. Answers to questions received and/or Amendments to the ITB Documents are as follows Q1. There are several large trees that appear to be in the city right of way. Due to the close proximity to the new water main, these trees cannot be protected IAW the Root Pruning and Root Barrier Detail. Will the city remove these trees, or allow them to be removed? Would there be an allowance for this if the contractor has to remove them? A1. Procurement reached out to the prospective bidder to obtain more specific information regarding the trees in question; however, no response was received. Without knowing more specific information, the City cannot answer if a tree or multiple trees will be removed by the City or be allowed for removal. The Engineer of Record (EOR), the City, and the Contractor will work together to resolve any issues with root pruning or the installation of root barriers with the most cost-effective method. Q2. Are the meters and meter boxes provided and installed by the City?? A2. Please see Addendum 02, Answer #2. Q3. Which insertion valve does the City prefer? A3. Please see Addendum 02, Answer #11. Shannon Hopper Shannon Hopper, CPPB Purchasing Technician II cc: Jen Bolling, Utilities Director Mayor Commissioners Rusty Johnson Scott R. Kennedy, District 1 Rosemary Wilsen, District 2 City Manager Richard Firstner, District 3 Craig Shadrix George Oliver III, District 4 Addendum No. 4 - ITB #26-001 Flewelling 2-Inch Water Main Replacement Project November 3, 2025 ADDENDUM NO. FOUR (4) CITY OF OCOEE ITB #26-001 Flewelling 2-Inch Water Main Replacement Project This addendum shall modify and become a part of the original ITB Documents. This addendum consists of one (1) page. Bidders should acknowledge receipt of this addendum in the space provided in the Bid Form. Failure to do so may subject the Bidder to disqualification. Answers to questions received and/or Amendments to the ITB Documents are as follows Q1. Can you please provide clarification to question 2 in addendum 3 on who is furnishing the meters and meter boxes? Also, if the contractor is to furnish, please provide a model and manufacturer for the boxes and meters. A1. The City will furnish both the meters and meter boxes. Alexis Chentouf Purchasing Technician cc: Jen Bolling, Utilities Director REWI S S T FLEW E L L I N G A V E WE S T A V E SP R I N G A V E HI L L A V E OR A N G E A V E CA R D I N A L S T JA Y S T MALC O M R D E SILVER STAR RD STRAKE LAKE LIST OF DRAWINGS SHEET NUMBER SHEET TITLE GENERAL G-01 TITLE SHEET, LOCATION MAP AND LIST OF DRAWINGS G-02 GENERAL NOTES G-03 ABBREVIATIONS AND SYMBOLS CIVIL C-01 KEY MAP C-02 PLAN AND PROFILE STA 0+00 TO STA 4+50 C-03 PLAN AND PROFILE STA 4+50 TO STA 8+20 C-04 PLAN AND PROFILE STA 10+00 TO STA 15+15 C-05 PLAN AND PROFILE STA 15+15 TO STA 20+26 C-06 PLAN AND PROFILE STA 22+00 TO STA 26+60 C-07 PLAN AND PROFILE STA 26+60 TO STA 31+52 C-08 PLAN AND PROFILE STA 31+52 TO STA 34+00 C-09 EXISTING 2-INCH WATER MAIN ABANDONMENT LIMITS STANDARD DETAILS CD-01 CITY STANDARD DETAILS - SHEET 1 CD-02 CITY STANDARD DETAILS - SHEET 2 D-01 STANDARD DETAILS D-02 POLLUTION PREVENTION DETAILS D-03 MATERIAL QUANTITY TABLE UTILITIES DEPARTMENT CITY OF OCOEE ISSUED FOR BID SUBMITTAL FLEWELLING 2-INCH WATER MAIN REPLACEMENT HAZEN PROJECT NO.: 41154-004 AUGUST 2025 LOCATION MAP NOT TO SCALE PROJECT ENGINEER OF RECORD: MELANIE PECKHAM, PE No. 66487 HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 CITY COMMISSION RUSTY JOHNSON, MAYOR CRAIG SHADRIX, CITY MANAGER MICHAEL RUMER, ASSISTANT CITY MANAGER SCOTT R. KENNEDY, DISTRICT 1 COMMISSIONER ROSEMARY WILSEN, DISTRICT 2 COMMISSIONER, PRO-TEM RICHARD FIRSTNER, DISTRICT 3 COMMISSIONER GEORGE OLIVER III, DISTRICT 4 COMMISSIONER WATER MAIN CONSTRUCTION NOTES:GENERAL NOTES: 1.ALL MATERIAL USED IN THE CONSTRUCTION OF THIS PROJECT SHALL BE NEW AND IN ACCORDANCE WITH THE CITY OF OCOEE ENGINEERING STANDARDS MANUAL APPROVED MANUFACTURER'S LIST, DETAILS AND APPLICABLE FDEP REGULATIONS. WHERE REFERENCED STANDARDS CONFLICT, THE MORE STRINGENT STANDARDS SHALL APPLY. 2.CONTRACTOR SHALL CONTACT SUNSHINE 811 A MINIMUM OF 2-DAYS AND A MAXIMUM OF 5-DAYS PRIOR TO START CONSTRUCTION. 3.LOCATIONS, ELEVATIONS AND DIMENSIONS OF EXISTING UTILITIES, STRUCTURES AND OTHER FEATURES ARE SHOWN ACCORDING TO THE BEST INFORMATION AVAILABLE AT THE TIME OF THE PREPARATION OF THESE PLANS. THE CONTRACTOR SHALL VERIFY THE LOCATION, ELEVATIONS AND DIMENSIONS OF ALL EXISTING UTILITIES, STRUCTURES AND OTHER FEATURES AFFECTING HIS WORK PRIOR TO CONSTRUCTION. EFFORTS WERE MADE TO INDICATE CONFLICTS BUT SHALL NOT BE LIMITED TO CONFLICTS SHOWN ON THE PLANS. IF DISCREPANCIES ARE DISCOVERED IN THE FIELD, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE CITY CONSTRUCTION REPRESENTATIVE. 4.CONTRACTOR SHALL PROVIDE TEMPORARY SANITATION FACILITIES FOR CONSTRUCTION PERSONNEL’S USE AND PAY ALL FEES FOR RENT, PUMP OUT, AND MAINTENANCE OF THE UNITS. UNAPPROVED DUMPING OF WASTE INTO EXISTING SANITARY LINES IS NOT ALLOWED. 5.CONTRACTOR SHALL SECURE THE STAGING AREA SITE FROM THE PUBLIC THROUGHOUT THE DURATION OF THE CONSTRUCTION CONTRACT TO PREVENT THEFT AND PROTECT PUBLIC FROM ACTIVE WORK AREAS. OPEN TRENCHES AND EXCAVATIONS SHALL BE FILLED IN EACH DAY OR OTHERWISE PROPERLY TAPED OFF WITH WARNING SIGNS POSTED TO PROMOTE PUBLIC SAFETY. 6.CONTRACTOR SHALL VERIFY IN THE FIELD THE LOCATION AND ELEVATION OF ALL EXISTING UTILITY CONNECTION POINT(S) PRIOR TO STARTING CONSTRUCTION AND SHALL IMMEDIATELY NOTIFY THE CITY CONSTRUCTION REPRESENTATIVE OF ANY DISCREPANCIES FOUND. 7.CONTRACTOR TO ENSURE CONTINUOUS UTILITY SERVICES DURING CONSTRUCTION OF PROPOSED UTILITY. ANY INTENTIONAL SERVICE INTERRUPTION SHALL BE COORDINATED WITH AND APPROVED BY THE AFFECTED UTILITY. 8.CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO PROTECT EXISTING AND NEWLY CONSTRUCTED UTILITIES DURING CONSTRUCTION. SHOULD ANY UTILITY LINE OR COMPONENT BECOME DAMAGED OR REQUIRE RELOCATION, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY CONSTRUCTION REPRESENTATIVE. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE TO EXISTING UTILITIES CAUSED DURING HIS OPERATIONS WITH NO ADDITIONAL COMPENSATION. 9.CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO PROTECT EXISTING STRUCTURES WITHIN THE CITY RIGHT-OF-WAYS DURING CONSTRUCTION. STRUCTURES SHOWN ON THE PLANS TO BE REMOVED AND REPLACED SHALL BE RESTORED TO THE GREATER OF THE EQUIVALENT PRE-CONSTRUCTION CONDITION OR CURRENT CITY SPECIFICATIONS. STRUCTURES DAMAGED BY CONSTRUCTION THAT ARE NOT SHOWN ON THE PLANS TO BE REMOVED AND REPLACED SHALL BE REPAIRED BY THE CONTRACTOR WITH NO ADDITIONAL COMPENSATION. 10.CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ANY UNSUITABLE MATERIAL FROM THE CONSTRUCTION OPERATION. UNSUITABLE MATERIAL SHALL BE DISPOSED OF IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS. WHERE CONFLICTS EXIST BETWEEN REQUIREMENTS, THE MOST STRINGENT SHALL APPLY. 11.THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY AND THE CONTRACTOR IS SOLELY RESPONSIBLE FOR CONSTRUCTION SAFETY. CONTRACTOR IS RESPONSIBLE FOR ANY SPECIAL PRECAUTIONS THAT MAY BE REQUIRED IN THE VICINITY OF POWER LINES AND OTHER UTILITIES. 12.CONTRACTOR IS RESPONSIBLE FOR CLEARLY IDENTIFYING THE AREA OF CONSTRUCTION. CONTRACTOR SHALL PROVIDE, ERECT AND MAINTAIN EFFECTIVE BARRICADES, DANGER SIGNALS, SIGNS AND PEDESTRIAN DETOURS IN ALL AREAS WHERE REQUIRED FOR THE PROTECTION OF THE WORK AND THE SAFETY OF THE PUBLIC. 13.THE CONTRACTOR SHALL FURNISH, ERECT AND MAINTAIN ALL NECESSARY TRAFFIC CONTROL AND SAFETY DEVICES, IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF TRANSPORTATION ROADWAY AND TRAFFIC DESIGN STANDARDS, LATEST EDITION. THE CONTRACTOR SHALL SUBMIT A MAINTENANCE OF TRAFFIC PLAN (INCLUDING FDOT INDEX NUMBERS) FOR BOTH VEHICULAR AND PEDESTRIAN TRAFFIC FOR REVIEW PRIOR TO BEGINNING CONSTRUCTION. FOR ANY PORTION OF THE MAINTENANCE OF TRAFFIC PLAN THAT DEVIATES FROM THE FDOT STANDARD INDEX, THE CONTRACTOR SHALL SUBMIT A PLAN SIGNED AND SEALED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF FLORIDA. 14.THE CONTRACTOR SHALL TAKE ALL REASONABLE MEANS TO ELIMINATE THE TRANSPORT OF DUST FROM THE PROJECT SITE. SPECIAL MEASURES, SUCH AS PERIODICALLY APPLYING WATER TO THE WORK SITE TO PREVENT DUST SHALL BE INCORPORATED INTO THE CONTRACTORS WORK PLAN. THE CONTRACTOR SHALL ENSURE THAT ADJACENT PROPERTIES ARE NOT IMPACTED BY WIND EROSION OR EMISSIONS OF UNCONFINED PARTICULATE MATTER IN ACCORDANCE WITH RULE 62-296.320(4)(C)1. 15.ALL SECTION CORNERS OR PROPERTY CORNERS DISLOCATED OR DISTURBED BY THE CONSTRUCTION ACTIVITIES SHALL BE RESET BY A REGISTERED LAND SURVEYOR AT THE CONTRACTOR EXPENSE. 16.UNLESS OTHERWISE NOTED ON THE PLANS, FINAL GRADE SHALL GENERALLY BE THE SAME AS EXISTING GRADE. 17.THE CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING OF ALL MAINS IN ACCORDANCE WITH CURRENT STANDARDS OF LOCAL JURISDICTION. CONTRACTOR SHALL NOTIFY THE CITY CONSTRUCTION REPRESENTATIVE AT LEAST 48 HOURS IN ADVANCE OF PERFORMING TESTS. 18.CONTRACTOR SHALL MAINTAIN AS-BUILT INFORMATION ON A REGULAR BASIS DURING CONSTRUCTION. CONTRACTOR SHALL PROVIDE CERTIFIED UTILITY AS-BUILT DRAWINGS IN ACCORDANCE WITH SECTION 3.01.05 OF THE CITY OF OCOEE ESM UPON COMPLETION OF THE WORK. (SEE CONTRACT DOCUMENTS). 19.ALL POTABLE AND FIRE SYSTEM COMPONENTS SHALL REMAIN OPERATIONAL DURING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE TO THESE SYSTEMS. 20.UNLESS OTHERWISE SHOWN, ALL PIPE SHALL BE INSTALLED VIA OPEN CUT CONSTRUCTION. 21.THE CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES AND THE CITY OCOEE UTILITY INSPECTOR AT (407) 666-5209 AT LEAST 48 HOURS BEFORE BEGINNING CONSTRUCTION. CONTRACTOR TO COORDINATE WITH INDIVIDUAL UTILITY OWNERS FOR RELOCATION, SUPPORT OF POLES, ETC. THAT ARE NECESSARY FOR CONSTRUCTING THE PROJECT AS SHOWN IN THE PLANS. 22 THE CONTRACTOR SHALL COORDINATE WITH CITY OF OCOEE AND OBTAIN APPROVAL BEFORE BEGINNING ANY LANE CLOSING OPERATIONS. 23.CITY ROADS TO BE OPEN CUT SHALL BE TEMPORARILY RESTORED UTILIZING DETAILS IN THIS PLAN SET. FOR FINAL RESTORATION OF CITY ROADS, CONTRACTOR SHALL UTILIZE DETAIL PW002. ALL PAVEMENT MARKINGS SHALL BE REPLACED IN LIKE KIND AND WITH MATERIALS IN ACCORDANCE WITH CITY SPECIFICATIONS, LATEST EDITION. 24.ANY SIDEWALK BEING REMOVED SHALL BE REPLACED IN ACCORDANCE WITH A.D.A STANDARDS FOR RUNNING AND CROSS SLOPING REPAIRS SHALL BE PER CITY OF OCOEE STANDARD DETAIL THE CONTRACTOR SHALL PROVIDE ADEQUATE AS-BUILT SPOT ELEVATIONS TO DETERMINE CODE COMPLIANCE. 25.CONTRACTOR SHALL MAINTAIN ADA COMPLIANT PEDESTRIAN ACCESS DURING CONSTRUCTION 26.ASPHALT REPAIRS TO ADJACENT OPEN CUTS SHALL BE DONE AT THE SAME TIME TO AVOID MULTIPLE PATCHES AND JOINTS. 27.A PRECONSTRUCTION MEETING SHALL TAKE PLACE WITH CITY OF OCOEE STAFF, ENGINEER, UTILITY COMPANIES, AND CONTRACTOR BEFORE THE START OF CONSTRUCTION. 28.WATER AND WASTEWATER SYSTEMS SHALL NOT BE PLACED IN SERVICE (FOR TEMPORARY OR PERMANENT USE) UNTIL ALL TESTING AND INSPECTIONS HAVE BEEN COMPLETED. TEST REPORTS AND AS-BUILTS FOR THOSE SYSTEMS COMPLETED SHALL BE SUBMITTED AND CLEARANCE OBTAINED FROM APPLICABLE UTILITIES AND PERMITTING AGENCIES BEFORE ANY SUCH USE. 29.EXISTING DRAINAGE STRUCTURES WITHIN CONSTRUCTION LIMITS SHALL REMAIN UNLESS OTHERWISE NOTED. DRAINAGE STRUCTURES THAT HAVE NOT BEEN CALLED OUT TO BE REPLACED AND ARE DISTURBED BY THE CONSTRUCTION ACTIVITY SHALL BE REPLACED BY THE CONTRACTOR AT HIS SOLE EXPENSE. 30.ALL PIPING MATERIALS AND ANY MATERIALS THAT WILL BE IN DIRECT CONTACT WITH DRINKING WATER MUST CONFORM TO APPLICABLE AWWA AND NSF REQUIREMENTS. 31.ALL MATERIALS SHALL BE IN COMPLIANCE WITH CITY OF OCOEE STANDARDS. 32.ANY DEVIATION FROM THE CITY OF OCOEE ENGINEERING STANDARDS MUST BE REQUESTED AND APPROVED IN WRITING PRIOR TO CONSTRUCTION. 33.IN CASE OF EMERGENCY. CONTACT THE CITY OF OCOEE UTILITIES ADMINISTRATION AT (407) 905-3159 DURING BUSINESS HOURS OR THE CITY OF OCOEE EMERGENCY DISPATCH AT (407) 428-5766 AFTER BUSINESS HOURS. 34.CONTRACTOR SHALL REFER TO THE CITY OF OCOEE ENGINEERING STANDARDS MANUAL, LAND DEVELOPMENT CODE, APPROVED MATERIALS LIST AND CITY DETAILS. THE MOST STRINGENT STANDARD BETWEEN THE CITY OF OCOEE STANDARDS AND STANDARDS SET FORTH IN THESE NOTES SHALL BE FOLLOWED. 35.AS-BUILTS SHALL BE SUBMITTED TO THE CITY SIGNED AND SEALED IN ACCORDANCE WITH SECTION 3.01.05 OF THE ENGINEERING STANDARDS MANUAL IN THE FOLLOWING FORMATS: A. ONE PDF COPY B. ONE CAD COPY DRAWN IN STATE PLANE COORDINATES 36.ALL OPEN TRENCHES AND HOLES ADJACENT TO ROADWAY OR WALKWAY SHALL BE PROPERLY MARKED AND BARRICADED TO ASSURE THE SAFETY OF BOTH VEHICULAR AND PEDESTRIAN TRAFFIC. 37.ALL TRENCHES OR OTHER EXCAVATIONS NEAR WALKWAYS, IN ROADWAYS OR THEIR SHOULDERS ARE TO BE BACK FILLED AND PROTECTED AT THE END OF EACH DAY. 38.ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE STABILIZED WITHIN A REASONABLE PERIOD OF TIME TO ASSURE MINIMUM EROSION OF SOILS. ALL EXPOSED AREAS SHALL BE SODDED AS SPECIFIED WITHIN 30 DAYS OF FINAL GRADING. 39.CONTRACTOR TO EMPLOY BEST MANAGEMENT PRACTICES THROUGHOUT CONSTRUCTION IN ORDER TO ENSURE POLLUTION PREVENTION. CONTRACT TO COMPLY WITH ALL LOCAL STATE AND OTHER GOVERNMENTAL ENVIRONMENTAL REGULATIONS THROUGHOUT CONSTRUCTION. 40.ALL STATIONS, OFFSETS, AND ELEVATIONS ON THESE PLANS ARE APPROXIMATE AND MAY REQUIRE ADJUSTMENT BASED ON FIELD CONDITIONS. CONTRACTOR TO PROVIDE CONSISTENT WATER MAIN SLOPE BETWEEN ELEVATIONS INDICATED ON PLANS. 41.ANY DISTURBED RESIDENTIAL YARDS SHALL BE FINE GRADED AND SODDED WITH LIKE KIND SOD. ALL EDGES OF NEW SOD THAT ABUTS EXISTING SOD SHALL BE CUT IN SO THE EXISTING GROUND COVER AND THE NEW SOD ARE FLUSH WITH EACH OTHER. 42.THE CONTRACTOR SHALL REPLACE / REPAIR ANY RIGHT-OF-WAY OR PRIVATE PROPERTY IMPROVEMENTS DAMAGED DURING THE COURSE OF THE WORK. 43.THE CONTRACTOR SHALL FURNISH AND INSTALL FITTINGS, COUPLINGS, CONNECTIONS, SLEEVES, ADAPTERS, HARNESS RODS AND CLOSURE PIECES AS REQUIRED TO CONNECT PIPELINES OF DISSIMILAR MATERIALS AND/OR SIZES FOR A COMPLETE INSTALLATION. 44.PROJECT REQUIRES A PRE-CONSTRUCTION VIDEO FOLLOWING THE REQUIREMENTS LISTED IN THE PROJECT MANUAL. 45.CONTRACTOR SHALL COORDINATE WITH HOMEOWNERS REGARDING PAVER STOCKPILING WHERE IMPACTED BY THE WORK. 1.SURVEY FOR EXISTING SUBSURFACE FEATURES WAS PROVIDED BY ECHO UES, INC., 400 STATE ROAD 434, SUITE 1024, OVIEDO, FLORIDA 32765. DATED SEPTEMBER 2024. THE LAST DATE OF FIELD EFFORT WAS ON 09/24/2024.THE LAST DATE OF EFFORT FOR TEST HOLE COLLECTION WAS ON TBD. 2.THE HORIZONTAL POSITIONS FOR ALL FEATURES SHOWN ON THE MAP ARE RELATIVE TO THE FLORIDA STATE PLANE COORDINATE SYSTEM, NORTH AMERICAN DATUM OF 1983/2011 ADJUSTMENT (NAD 83/11), ZONE 901, FLORIDA EAST. HORIZONTAL CONTROL WAS ESTABLISHED USING THE FLORIDA DEPARTMENT OF TRANSPORTATION'S (FDOT) FLORIDA PERMANENT REFERENCE NETWORK (FRPN), A REAL TIME KINEMATIC (RTK) GLOBAL POSITIONING SYSTEM (GPS). 3.VERTICAL INFORMATION SHOWN HEREON IS RELATIVE TO SITE CONTROL AS PROVIDED BY CLIENT. 4.THE LOCATION OF ALL EXISTING UTILITIES, POWER, WATER, SEWER, PHONE, COMMUNICATION AND STORM DRAINAGE SHOWN ON THE PLANS HAVE BEEN DETERMINED FROM THE BEST INFORMATION AVAILABLE AND ARE GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR INACCURACY. PRIOR TO START OF ANY CONSTRUCTION ACTIVITY, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITIES AND TO MAKE THE NECESSARY ARRANGEMENTS FOR ANY RELOCATION OF THESE UTILITIES WITH THE OWNER OF THE UTILITY. THE CONTRACTOR SHALL EXERCISE CAUTION WHEN CROSSING UNDERGROUND UTILITIES, WHETHER SHOWN ON THE PLANS OR LOCATED BY THE UTILITY COMPANY. ALL UTILITIES WHICH INTERFERE WITH THE PROPOSED CONSTRUCTION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER/OWNER IMMEDIATELY. ANY FEES ASSOCIATED WITH UTILITY RELOCATIONS SHALL BE BORNE IN ACCORDANCE WITH THE RESPECTIVE UTILITY COMPANY STANDARDS. IF IT IS REQUESTED THAT UTILITY COMPANIES MOVE THEIR PARTICULAR UTILITIES, ANY DELAY OR INCONVENIENCE CAUSED TO THE CONTRACTOR BY THE RELOCATION OF THE VARIOUS UTILITIES SHALL BE INCIDENTAL TO THE CONTRACT AND NO EXTRA COMPENSATION WILL BE ALLOWED. G-02 GENERAL NOTES PROJECT SURVEY NOTES: A. POTABLE WATER, RECLAIMED WATER, SANITARY SEWER: CITY OF OCOEE (407) 905-3159 B. TELEPHONE: CENTURYLINK (850) 815-3144 C. TELEPHONE: CHARTER COMMUNICATIONS (813) 302-0800 D. ELECTRIC: DUKE ENERGY (407) 629-1010 E. FIBER: ZAYO GROUP (406) 496-6510 F. TELEPHONE: AT&T (800) 247-2020 UTILITY PROVIDERS: 1.EXISTING 2-INCH WM PLACED OUT OF SERVICE SHALL BE CUT AND CAPPED. 2.INSTALL NEW HYDRANTS AND NEW ISOLATION VALVES ON THE NEW WATER MAINS AS NOTED. 3.PRESSURE TEST AND DISINFECT EACH SECTION OF NEW WATER MAIN BETWEEN ISOLATION VALVES AND OBTAIN CLEARANCE FROM FDEP PRIOR TO MAKING CONNECTIONS TO CUSTOMERS. 4.CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING ALL BACTERIOLOGICAL TESTING PER FDEP REQUIREMENTS AND THESE CONTRACT DOCUMENTS. CONTRACTOR SHALL SCHEDULE A CERTIFIED WATER LAB TO PULL BACTERIOLOGICAL SAMPLES NO MORE THAN 24 HOURS AFTER DISINFECTING WATER MAINS. 5.CONTRACTOR SHALL COORDINATE WITH THE CITY AND RESIDENTS WHEN TRANSFERRING SERVICES FROM EXISTING MAINS TO NEW MAINS. NO SERVICES SHALL BE TRANSFERRED UNTIL NEW MAINS HAVE BEEN APPROVED FOR USE. WATER SERVICE SHALL BE MAINTAINED AT ALL TIMES. WHERE SHUTDOWN IS REQUIRED, THE LOSS OF SERVICE SHALL BE KEPT TO A MINIMUM, AND PRE-APPROVED BY ENGINEER AND OWNER. CONTRACTOR SHALL PROVIDE ADVANCE NOTICE TO THE CITY OF OCOEE AND SERVICE CONNECTIONS PRIOR TO ANY LOSS OF SERVICE. WHERE REMOVAL SEQUENCING REQUIRES TEMPORARY SERVICES BE INSTALLED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING SUCH SERVICES. 6.NOTIFY EACH CUSTOMER AT LEAST 48 HOURS BEFORE DISCONNECTING WATER SERVICE FOR THE REPLACEMENT OF EXISTING POTABLE WATER FEED. NOTIFICATION SHOULD BE MADE BY DOOR HANGERS WITH WORDING APPROVED BY THE CITY AND PROVIDE DATE AND TIME PERIOD THAT CAN BE EXPECTED FOR THE INTERRUPTION OF SERVICE. 7.AFTER ALL CUSTOMERS HAVE BEEN TRANSFERRED TO THE NEW WATER MAIN, CUT AND CAP THE CONNECTIONS TO THE EXISTING WATER MAIN AT THE TIE-IN POINT TO THE DISTRIBUTION SYSTEM BEFORE ABANDONING EXISTING MAINS. 8.SERVICE CONNECTION TO NEW WATER MAINS SHALL INCLUDE SERVICE SADDLES, CORP STOPS, POLY TUBING, ANGLED CURB STOPS AND RECONNECTION TO EXISTING METERS. 9.ALL NEW WATER MAINS REQUIRE A FULL DIAMETER FLUSH WITNESSED BY THE CITY OF OCOEE UTILITY INSPECTOR. PRELIMINARY PRESSURE TESTING IS REQUIRED PRIOR TO SCHEDULING ANY FORMAL TESTING WITH THE CITY'S UTILITY INSPECTOR. 10.CONTRACTOR SHALL CONTACT THE CITY OF OCOEE UTILITY INSPECTOR AT LEAST 48 HOURS PRIOR TO ALL PRESSURE TESTS AND DISINFECTION OF WATER MAINS. 11.ALL JOINTS OF WATER MAINS SHALL BE RESTRAINED. ASSUME THAT THE EXISTING PIPE IS NOT RESTRAINED. FOR TIE-INS, EXCAVATE EXISTING PIPE JOINTS, FITTINGS AND VALVES AND RESTRAIN IN ACCORDANCE WITH CITY STANDARD DETAILS. 12.MAXIMUM DEFLECTIONS AT PIPE JOINTS, FITTING AND LAYING RADIUS FOR THE VARIOUS PIPE LENGTHS SHALL NOT EXCEED 75 PERCENT OF THE PIPE MANUFACTURER'S RECOMMENDATION. PL O T D A T E : 8/ 1 4 / 2 0 2 5 3 : 1 8 p . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ G E N E R A L \ G - 0 2 S a v e d b y HP S a v e d a t e : 8/ 1 4 / 2 0 2 5 3 : 1 7 p . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP CJ CONSTRUCTION JOINT T.O.B. TS TRANS TOE T.O.P. TRANSFORMER TOE OF BERM TOP OF PIPE TOP OF BANK TAPPING SLEEVE UGE UG WTR VERT WATER VERTICAL UNDERGROUND UNDERGROUND ELECTRIC W WWF WL W WELDED WIRE FABRIC WITH WATER LEVEL WEST PL RADR RADIUS PROPERTY LINE INSIDE DIAMETERID RED REINF REQD REDUCER REQUIRED REINFORCING SHT SS SQ SPEC SECT SQUARE SPECIFICATION SHEET STAINLESS STEEL SECTION ISOLATION INTERIOR INSULATION INVERT JOINT JUNCTION BOX INSUL INT ISO INV JT JB LINE MANHOLE LOW POINT MAXIMUM MASONRY OPENING MECHANICAL MANUFACTURER LN LP MH MO MANUF MECH MAX LG LONG STL S STRUC STEEL STRUCTURAL SOUTH TOPT TB SWK THK TI TBD TEMP TEMPERATURE INDICATOR THICK TO BE DETERMINED TEMPORARY SIDEWALK TOP OF BERM MISCELLANEOUS NORTH NOT IN CONTRACT MOV MISC N NIC NUMBER OPENING NOT TO SCALE OVERHEAD WIRE ON CENTER PAGE OUTSIDE FACE OUTSIDE DIAMETER NTS NO OPNG OC OHW OD OF PG MOTOR OPERATED VALVE TYP TOC TOS TOP OF CONCRETE TOP OF SLAB TYPICAL POTABLE PRESSURE SWITCHPS POT TO THROUGHOUT MINIMUMMIN DOWN DRAIN DRAWING DN D DWG GENERAL ANCHOR BOLT ANGLE ALUMINUM AB ALUM DRIVEWAY EACH EAST EXPANSION BOLT EA E EM EB DW ECCENTRIC EACH FACE EACH WAY EQUIPMENT ELEVATION ELECTRIC EF EQUIP EOP ELELEV ECC ELEC EW ARCHITECTURAL ASPHALT BOTTOM BUILDING BOLLARDBOL BOTT ARCH BLDG ASPH CORROSION PROTECTIONCP CBS CLP CONCRETE LIGHT POLE CONCRETE BLOCK & STUCCO APPROX APPROXIMATE DIP DUCTILE IRON PIPE PIPING IPS IRON PIPE SIZE VALVES, FITTINGS, ETC. BV ARV CV CMP BFV CHECK VALVE AIR RELIEF VALVE BALL VALVE BUTTERFLY VALVE CORRUGATED METAL PIPE EXISTING FOOTING FLOOR FINISHFIN FL EXIST FTG FINISHED FLOOR GRADE GALVANIZED FRAME FE FF FR GR GALV CENTER LINE CONCRETE SLAB CENTER TO CENTER CHECKERED CL CS CC CHKD CONCRETE COLUMN DETAIL CONTINUOUS CONTRACTOR COL DET CONT CONTR CONC HIGH POINT HIGHH HP DIAMETER DIMENSION DIA DIM FH CPLG GV HB FLG FTG GATE VALVE HOSE BIB FIRE HYDRANT FLANGE FITTING COUPLING LR MJ NPT PV NATIONAL PIPE THREAD PLUG VALVE LONG RADIUS MECHANICAL JOINT SOV THD SOLENOID OPERATED VALVE THREADED ELECTRICAL METER EDGE OF PAVEMENT ABBREVIATIONS FIRE EXTINGUISHER, OR FLOW ELEMENT ANG HORIZONTALHORIZ EXPANSION JOINTEJ UNO UNLESS NOTED OTHERWISE TM TRANSMISSION MAIN (2) ON DRAWING C11 THIS DETAIL IDENTIFIED AS: (1) DETAIL CALL-OUT ON DRAWING C10 DETAIL IDENTIFICATION * NOTE: IF PLAN AND SECTION (OR DETAIL CALL-OUT AND DETAIL) ARE SHOWN ON SAME DRAWING, DRAWING NUMBER IS REPLACED BY A LINE. Legend CMP = Corrugated Metal Pipe CCR = Certified Corner Record CONC = Concrete TRAV = Traverse = Air Conditioning Unit = Benchmark = Electric Junction Box = Fiber Optic Marker = Fire Hydrant = Flat Grate Inlet = Gas Line Marker = Gas Meter = Gas Valve = Mailbox = Metal Light Pole = Metal Traffic Signal Pole = Parking Meter = Sign = Telephone Manhole = Telephone Pullbox = Telephone Riser = Televison Pullbox = Television Riser = Traffic Signal Panel = Transformer = Trashcan = Water Meter = Water Valve = Bottom of Bank = Top of Bank = Gas Line Paint Marks = Treeline = Maple (Diameter in inches) = Oak (Diameter in inches) = Pine Tree (Diameter in inches) = Reclaimed Water Line = Buried Electric Line = Monitoring Well = Backflow Preventer = Test hole BB TB G E F G G G PM T T T TV TV TR W RW E MW AVV AIR VACUUM VALVE ISV ISOLATION VALVE PRV PRESSURE RELIEF VALVE RW RECLAIMED WATER 1 M01 DETAIL 1 1/2" = 1'-0"M01 G-03 ABBREVIATIONS AND SYMBOLS DETAIL IDENTIFICATION GALVANIZED STEELGS PVC POLYVINYLCHLORIDE ASBESTOS CEMENTAC BACTERIOLOGICAL SAMPLING LOCATIONBSL PL O T D A T E : 8/ 1 4 / 2 0 2 5 3 : 1 8 p . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ G E N E R A L \ G - 0 3 S a v e d b y OS C A R S a v e d a t e : 6/ 5 / 2 0 2 5 1 2 : 3 8 a . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP 20+3010+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00 33+98 8+190+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W PL O T D A T E : 8/ 1 4 / 2 0 2 5 3 : 1 9 p . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ C I V I L \ C - 0 1 S a v e d b y HP S a v e d a t e : 6/ 2 4 / 2 0 2 5 1 0 : 0 9 a . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP 25 50'050 1"=50'-0" C-01 CIVIL KEY MAP PLAN 1" = 50' C-02 CARDINAL STREET C-03 C-04 C-05 C-06 C-07 C-08 ORANGE AVENUE JAY STREET CE N T E R S T R E E T F L E W E L L I N G A V E N U E NOTES: 1.KEY MAP FOR PROPOSED WORK ONLY. DEMOLITION LIMITS SHOWN ON DRAWING C-09. 0+00 1+00 2+00 3+00 4+00 W W W W W STA. 3+63, 17.47R NEW FH ASSEMBLY 6" GATE VALVE AND BOX STA 3+63, 15.42R 6" 45° BEND STA 0+19, 38.04 R 6" 45° BEND STA 0+43, 13.25 R 6" X 6" TEE STA 0+08, 38.20 R 6" X 6" HYDRANT TEE STA 3+63, 13.60 R STA. 2+61, 13.46R 0.5° VERT. DEFLECT STA. 1+86, 13.23R 1.5° VERT. DEFLECT 6" GATE VALVE AND BOX STA 0+10, 38.16R 6" DI WATER MAIN CLASS 350 STA. 0+13, 41.75R FIRE HYDRANT ASSEMBLY 6" MJ CONNECTION SLEEVE STA 0+08, 45.14 R 6" INSERTION VALVE WITH THRUST COLLAR STA 0+08, 24.40 R 6" INSERTION VALVE WITHOUT THRUST COLLAR STA 0+08, 67.56 R 36 " MI N . ST A . 0 + 4 3 6" 4 5 ° B E N D CL E L 1 3 9 . 4 7 ST A . 0 + 1 9 6" 4 5 ° B E N D CL E L 1 3 9 . 2 7 36 " MI N . 6" DI WATER MAIN CLASS 350 6" DI WA T E R M A I N C L A S S 3 5 0 ST A . 0 + 1 0 . 3 8 6" G A T E V A L V E A N D B O X CL . E L E V . 1 3 9 . 2 7 ST A . 0 + 0 8 6" X 6 " T E E CL E L 1 3 9 . 2 7 EX I S T . 2 " U G T IN V E L . U N K . EX I S T . 1 " U G T IN V E L . U N K . ST A . 3 + 6 3 6" X 6 " H Y D R A N T T E E CL E L 1 4 8 . 1 9 12 " MI N . 12 " MI N . EX I S T . U N K IN V E L . U N K . 12 " MI N . ST A . 2 + 6 1 0. 5 ° V E R T . D E F L E C T T. O . P . E L . 1 4 8 . 1 5 ST A . 1 + 8 6 1. 5 ° V E R T . D E F L E C T T. O . P . E L . 1 4 6 . 8 2 0+00 1+00 2+00 3+00 4+00 PL O T D A T E : 9/ 3 / 2 0 2 5 1 0 : 0 7 a . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ C I V I L \ C - 0 2 S a v e d b y HP S a v e d a t e : 9/ 3 / 2 0 2 5 1 0 : 0 7 a . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP 10 20'020 1"=20'-0" LEGEND CL UGE UGT GAS FOC CONCRETE ELEVATION OVERHEAD ELECTRIC EXISTING STORM SEWER LINE EXISTING SANITARY SEWER LINE EXISTING WATER LINE PROPOSED WATER MAIN EXISTING ELECTRIC LINE EXISTING TELEPHONE LINE EXISTING GAS LINE EXISTING FIBER OPTIC CABLE PROPERTY LINE EASEMENT LINE R/W RIGHT OF WAY CENTERLINE PALM TREE OAK TREE HOLLY TREE PINE TREE UNIDENTIFIED TREE TO BE REMOVED NOTES: 1.LOCATION AND ELEVATION OF ALL EXISTING UTILITIES SHOWN ON THESE PLANS ARE TO BE CONSIDERED APPROXIMATE AND SHOULD BE VERIFIED BY CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXISTING UTILITIES AND COORDINATING WITH UTILITY OWNERS DURING CONSTRUCTION. 2.STATIONING IS ALONG CENTERLINE OF PAVEMENT WITH OFFSETS. 3.ALL ASPHALT / CONCRETE SHALL BE SAW CUT WITH STRAIGHT LINES PRIOR TO EXCAVATION. 4.DIMENSIONS AND ELEVATIONS MAY VARY. DIMENSIONS AND ELEVATIONS ARE BASED ON AS-BUILT INFORMATION AND TOPOGRAPHIC SURVEY. 5.CONTRACTOR SHALL PROTECT AND/OR REMOVE AND REINSTALL MAILBOXES, SIGNAGE, FENCING, ETC. AS REQUIRED FOR THE WORK. ANY DAMAGED ITEMS AS A RESULT OF THE WORK SHALL BE REPLACED AT NO COST TO THE OWNER. NOT SHOWN FOR CLARITY. 6.REPLACE ALL SOD AND LANDSCAPING THAT IS DAMAGED DURING CONSTRUCTION AND REPAIR ALL EXISTING IRRIGATION. 7.CONTRACTOR SHALL ASSUME THE EXISTING MAINS ARE NOT RESTRAINED. FOR TIE-INS, EXCAVATE EXISTING PIPE JOINTS, FITTINGS AND VALVES AND RESTRAIN IN ACCORDANCE WITH CITY OF OCOEE ENGINEERING STANDARDS AND DETAILS. 8.ALL NEW MAINS TO BE FULLY RESTRAINED. CITY DETAILS UT004 AND UT005 TO BE USED FOR EXISTING MAINS ONLY. 9.CONTRACTOR SHALL REPLACE ALL SIDEWALK REMOVED FOR THE PROJECT JOINT TO JOINT PER FDOT INDEX 522-001. SIDEWALK REMOVAL LIMITS NOT SHOWN FOR CLARITY. 10.TREES ON PRIVATE PROPERTY TO BE PROTECTED. TREES WITHIN RIGHT OF WAY TO BE PROTECTED. IF TREES WITHIN RIGHT OF WAY CANNOT BE PROTECTED, CONTRACTOR SHALL REMOVE FOLLOWING OWNER APPROVAL. 11.CONTRACTOR SHALL COORDINATE LOCATION OF ALL WATER SERVICES WITH THE CITY. NO SURVEY AVAILABLE FOR SERVICES ON THE WEST SIDE OF THE RIGHT OF WAY. CONSTRUCTION OF WATER SERVICES SHALL INCLUDE NECESSARY PAVEMENT RESTORATION AND MOT. 12.LONG SIDE POLY SERVICES SHALL BE INSTALLED USING TRENCHLESS CONSTRUCTION METHODS TO NOT IMPACT THE ROADWAY. C-02 CIVIL PLAN AND PROFILE STA 0+00 TO STA 4+50 ST A 4 + 5 0 M A T C H L I N E S E E D W G C - 0 3 PLAN 1" = 20' ORANGE AVENUE CE N T E R S T R E E T EXISTING 6" PVC WATER MAIN 9 CD-02 KEY PLAN AREA DEPICTED REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT REMOVE AND STOCKPILE LANDSCAPING EXISTING TREES TO BE PROTECTED (SEE NOTE 10) PROTECT EXISTING UNK UTILITY EXISTING TREES TO BE PROTECTED PROFILE 1"=4'-0" VERTICAL 1"=20'-0" HORIZONTAL 150 155 145 140 135 150 155 145 140 135 600 CENTER STREET 607 ORANGE AVENUE 611 ORANGE AVENUE 615 ORANGE AVENUE EXISTING GRADE 3. 0 0 ' MI N . 3. 0 0 ' MI N . 440 LF OF OPEN CUT ORANGE AVENUE CARDINAL STREET JAY STREET F L E W E L L I N G A V E N U E CE N T E R S T R E E T CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES TO 604 CENTER STREET. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. REMOVE FIRE HYDRANT ASSEMBLY REMOVE, STORE, AND REINSTALL SIGN 14 CD-02 14 CD-02 14 CD-02 14 CD-02 14 CD-02 PROTECT EXISTING OHE PROTECT UGT REMOVE AND REPLACE ASPHALT PAVEMENT 504 CENTER STREET 606 ORANGE AVENUE 612 ORANGE AVENUE 614 ORANGE AVENUE CONSTRUCT DETECTABLE WARNING PER FDOT INDEX 522-002 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 3. 0 0 ' MI N . 464 LF OPEN CUT ON THIS SHEET 19 D-01 9 CD-02 EXISTING 6" PVC WATER MAIN TO BE REMOVED (APPROX. 25 LF) 6" DI WATER MAIN CLASS 350 6" DI WATER MAIN CLASS 350 CL CL8+195+00 6+00 7+00 8+00 W W W W W W W W 6" 45° BEND STA 7+95, 14.39 R 6" 45° BEND STA 7+98, 17.89 R ST A . 7 + 9 5 6" 4 5 ° B E N D CL E L 1 4 9 . 5 0 ST A . 7 + 9 8 6" 4 5 ° B E N D CL E L 1 4 9 . 5 0 36 " MI N . 6" DI WATER MAIN CLASS 350 5+00 6+00 7+00 8+00 PL O T D A T E : 8/ 1 4 / 2 0 2 5 3 : 2 0 p . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ C I V I L \ C - 0 3 S a v e d b y HP S a v e d a t e : 8/ 1 1 / 2 0 2 5 3 : 2 8 p . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP 10 20'020 1"=20'-0" C-03 CIVIL PLAN AND PROFILE STA 4+50 TO STA 8+20 ST A 4 + 5 0 M A T C H L I N E S E E D W G C - 0 2 PLAN 1" = 20' ORANGE AVENUE F L E W E L L I N G A V E N U E 3. 0 ' MI N . 3. 0 ' MI N . REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT REMOVE AND STOCKPILE PAVERS EXISTING 6" GATE VALVE REMOVE CAP AND BLOW-OFF ASSEMBLY AND CONNECT TO EXISTING 6 INCH DI WATER MAIN W/ MJ SLEEVE EXISTING FIRE HYDRANT 3. 0 ' MI N . KEY PLAN AREA DEPICTED PROFILE 1"=4'-0" VERTICAL 1"=20'-0" HORIZONTAL 150 155 145 140 135 150 155 145 140 135 621 ORANGE AVENUE 625 ORANGE AVENUE 627 ORANGE AVENUE 631 ORANGE AVENUE629 ORANGE AVENUE EXISTING GRADE 361 LF OF OPEN CUT REMOVE, STORE, AND REINSTALL SIGN CONNECT TO EXISTING WATER MAIN ORANGE AVENUE CARDINAL STREET JAY STREET F L E W E L L I N G A V E N U E CE N T E R S T R E E T CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. 11 CD-02 CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION.CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) 14 CD-02 14 CD-0214 CD-02 14 CD-02 14 CD-02 14 CD-02 14 CD-02 PROTECT EXISTING OHE LEGEND CL UGE UGT GAS FOC CONCRETE ELEVATION OVERHEAD ELECTRIC EXISTING STORM SEWER LINE EXISTING SANITARY SEWER LINE EXISTING WATER LINE PROPOSED WATER MAIN EXISTING ELECTRIC LINE EXISTING TELEPHONE LINE EXISTING GAS LINE EXISTING FIBER OPTIC CABLE PROPERTY LINE EASEMENT LINE R/W RIGHT OF WAY CENTERLINE PALM TREE OAK TREE HOLLY TREE PINE TREE UNIDENTIFIED TREE TO BE REMOVED CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) 14 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 618 ORANGE AVENUE 624 ORANGE AVENUE 626 ORANGE AVENUE 630 ORANGE AVENUE 361 LF OPEN CUT ON THIS SHEET NOTES: 1.LOCATION AND ELEVATION OF ALL EXISTING UTILITIES SHOWN ON THESE PLANS ARE TO BE CONSIDERED APPROXIMATE AND SHOULD BE VERIFIED BY CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXISTING UTILITIES AND COORDINATING WITH UTILITY OWNERS DURING CONSTRUCTION. 2.STATIONING IS ALONG CENTERLINE OF PAVEMENT WITH OFFSETS. 3.ALL ASPHALT / CONCRETE SHALL BE SAW CUT WITH STRAIGHT LINES PRIOR TO EXCAVATION. 4.DIMENSIONS AND ELEVATIONS MAY VARY. DIMENSIONS AND ELEVATIONS ARE BASED ON AS-BUILT INFORMATION AND TOPOGRAPHIC SURVEY. 5.CONTRACTOR SHALL PROTECT AND/OR REMOVE AND REINSTALL MAILBOXES, SIGNAGE, FENCING, ETC. AS REQUIRED FOR THE WORK. ANY DAMAGED ITEMS AS A RESULT OF THE WORK SHALL BE REPLACED AT NO COST TO THE OWNER. NOT SHOWN FOR CLARITY. 6.REPLACE ALL SOD AND LANDSCAPING THAT IS DAMAGED DURING CONSTRUCTION AND REPAIR ALL EXISTING IRRIGATION. 7.CONTRACTOR SHALL ASSUME THE EXISTING MAINS ARE NOT RESTRAINED. FOR TIE-INS, EXCAVATE EXISTING PIPE JOINTS, FITTINGS AND VALVES AND RESTRAIN IN ACCORDANCE WITH CITY OF OCOEE ENGINEERING STANDARDS AND DETAILS. 8.ALL NEW MAINS TO BE FULLY RESTRAINED. CITY DETAILS UT004 AND UT005 TO BE USED FOR EXISTING MAINS ONLY. 9.CONTRACTOR SHALL REPLACE ALL SIDEWALK REMOVED FOR THE PROJECT JOINT TO JOINT PER FDOT INDEX 522-001. SIDEWALK REMOVAL LIMITS NOT SHOWN FOR CLARITY. 10.TREES ON PRIVATE PROPERTY TO BE PROTECTED. TREES WITHIN RIGHT OF WAY TO BE PROTECTED. IF TREES WITHIN RIGHT OF WAY CANNOT BE PROTECTED, CONTRACTOR SHALL REMOVE FOLLOWING OWNER APPROVAL. 11.CONTRACTOR SHALL COORDINATE LOCATION OF ALL WATER SERVICES WITH THE CITY. NO SURVEY AVAILABLE FOR SERVICES ON THE WEST SIDE OF THE RIGHT OF WAY. CONSTRUCTION OF WATER SERVICES SHALL INCLUDE NECESSARY PAVEMENT RESTORATION AND MOT. 12.LONG SIDE POLY SERVICES SHALL BE INSTALLED USING TRENCHLESS CONSTRUCTION METHODS TO NOT IMPACT THE ROADWAY. 10+00 11+00 12+00 13+00 14+00 15+00 W W W W W W 6" DI WATER MAIN CLASS 350 6" X 6" TAPPING SLEEVE STA 10+07, 22.83 R 6" GATE VALVE AND BOX STA 10+10, 22.78R 6" GATE VALVE AND BOX STA 11+38, 21.34R 6" X 6" HYDRANT TEE STA 11+38, 19.58 R STA. 14+99, 12.00R 1° HORIZ. DEFLECTSTA. 11+39, 25.41R NEW FH ASSEMBLY 10+00 11+00 12+00 13+00 14+00 15+00 36 " MI N . 36 " MI N . 6" DI WATER MAIN CLASS 350 12 " MI N . 12 " MI N . ST A . 1 0 + 0 7 6" X 6 " T A P P I N G S L E E V E CL E L 1 4 3 . 7 6 ST A . 1 1 + 3 8 6" X 6 " H Y D R A N T T E E CL E L 1 4 7 . 6 8 ST A . 1 0 + 1 0 . 0 9 6" G A T E V A L V E A N D B O X CL . E L E V . 1 4 3 . 8 2 EX I S T . 2 " U G T TO P E L . 1 4 9 . 7 9 EX I S T . 3 6 " S D IN V E L . 1 3 7 . 6 6 ST A . 1 4 + 9 9 1° H O R I Z . D E F L E C T T. O . P . E L . 1 5 1 . 8 8 PL O T D A T E : 8/ 1 4 / 2 0 2 5 3 : 2 0 p . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ C I V I L \ C - 0 4 S a v e d b y HP S a v e d a t e : 8/ 1 1 / 2 0 2 5 3 : 3 0 p . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP 10 20'020 1"=20'-0" C-04 CIVIL PLAN AND PROFILE STA 10+00 TO STA 15+15 ST A 1 5 + 1 5 M A T C H L I N E S E E D W G C - 0 5 PLAN 1" = 20' 3. 0 ' MI N . REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT REMOVE AND REPLACE DETECTABLE WARNING PER FDOT INDEX 522-002 CONTRACTOR SHALL PROTECT EXISTING OH POWER POLE EXISTING 6" PVC WATER MAIN 9 CD-02 CARDINAL STREET CE N T E R S T R E E T KEY PLAN AREA DEPICTED 3. 0 ' MI N . PROFILE 1"=4'-0" VERTICAL 1"=20'-0" HORIZONTAL 150 155 145 140 700 CENTER STREET 603 CARDINAL STREET 609 CARDINAL STREET 613 CARDINAL STREET 617 CARDINAL STREET EXISTING GRADE 508 LF OF OPEN CUT 135 150 155 145 140 135 ORANGE AVENUE CARDINAL STREET JAY STREET F L E W E L L I N G A V E N U E CE N T E R S T R E E T CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) 11 CD-02 CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. 14 CD-02 14 CD-02 14 CD-02 14 CD-02 14 CD-02 REMOVE AND REPLACE CONCRETE CURB IN KIND PROTECT UGT CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) 14 CD-02 REMOVE AND REPLACE ASPHALT PAVEMENT 10+00 REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 508 LF OPEN CUT ON THIS SHEET 606 CENTER STREET 600 CARDINAL STREET 608 CARDINAL STREET 612 CARDINAL STREET 616 CARDINAL STREET LEGEND CL UGE UGT GAS FOC CONCRETE ELEVATION OVERHEAD ELECTRIC EXISTING STORM SEWER LINE EXISTING SANITARY SEWER LINE EXISTING WATER LINE PROPOSED WATER MAIN EXISTING ELECTRIC LINE EXISTING TELEPHONE LINE EXISTING GAS LINE EXISTING FIBER OPTIC CABLE PROPERTY LINE EASEMENT LINE R/W RIGHT OF WAY CENTERLINE PALM TREE OAK TREE HOLLY TREE PINE TREE UNIDENTIFIED TREE TO BE REMOVED NOTES: 1.LOCATION AND ELEVATION OF ALL EXISTING UTILITIES SHOWN ON THESE PLANS ARE TO BE CONSIDERED APPROXIMATE AND SHOULD BE VERIFIED BY CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXISTING UTILITIES AND COORDINATING WITH UTILITY OWNERS DURING CONSTRUCTION. 2.STATIONING IS ALONG CENTERLINE OF PAVEMENT WITH OFFSETS. 3.ALL ASPHALT / CONCRETE SHALL BE SAW CUT WITH STRAIGHT LINES PRIOR TO EXCAVATION. 4.DIMENSIONS AND ELEVATIONS MAY VARY. DIMENSIONS AND ELEVATIONS ARE BASED ON AS-BUILT INFORMATION AND TOPOGRAPHIC SURVEY. 5.CONTRACTOR SHALL PROTECT AND/OR REMOVE AND REINSTALL MAILBOXES, SIGNAGE, FENCING, ETC. AS REQUIRED FOR THE WORK. ANY DAMAGED ITEMS AS A RESULT OF THE WORK SHALL BE REPLACED AT NO COST TO THE OWNER. NOT SHOWN FOR CLARITY. 6.REPLACE ALL SOD AND LANDSCAPING THAT IS DAMAGED DURING CONSTRUCTION AND REPAIR ALL EXISTING IRRIGATION. 7.CONTRACTOR SHALL ASSUME THE EXISTING MAINS ARE NOT RESTRAINED. FOR TIE-INS, EXCAVATE EXISTING PIPE JOINTS, FITTINGS AND VALVES AND RESTRAIN IN ACCORDANCE WITH CITY OF OCOEE ENGINEERING STANDARDS AND DETAILS. 8.ALL NEW MAINS TO BE FULLY RESTRAINED. CITY DETAILS UT004 AND UT005 TO BE USED FOR EXISTING MAINS ONLY. 9.CONTRACTOR SHALL REPLACE ALL SIDEWALK REMOVED FOR THE PROJECT JOINT TO JOINT PER FDOT INDEX 522-001. SIDEWALK REMOVAL LIMITS NOT SHOWN FOR CLARITY. 10.TREES ON PRIVATE PROPERTY TO BE PROTECTED. TREES WITHIN RIGHT OF WAY TO BE PROTECTED. IF TREES WITHIN RIGHT OF WAY CANNOT BE PROTECTED, CONTRACTOR SHALL REMOVE FOLLOWING OWNER APPROVAL. 11.CONTRACTOR SHALL COORDINATE LOCATION OF ALL WATER SERVICES WITH THE CITY. NO SURVEY AVAILABLE FOR SERVICES ON THE WEST SIDE OF THE RIGHT OF WAY. CONSTRUCTION OF WATER SERVICES SHALL INCLUDE NECESSARY PAVEMENT RESTORATION AND MOT. 12.LONG SIDE POLY SERVICES SHALL BE INSTALLED USING TRENCHLESS CONSTRUCTION METHODS TO NOT IMPACT THE ROADWAY. 20+3016+00 17+00 18+00 19+00 20+00 W W W W W W W 6" 45° BEND STA 20+16, 26.55 R 6" 45° BEND STA 20+03, 13.26 R 6" X 6" HYDRANT TEE STA 15+91, 12.35 R 6" DI WATER MAIN CLASS 350 STA. 18+03, 13.09R 1° HORIZ. DEFLECT 20+3016+00 17+00 18+00 19+00 20+00 W W W W W W W 6" GATE VALVE AND BOX STA 15+91, 14.46R 6" GATE VALVE AND BOX STA 15+93, 12.36R STA. 15+91, 20.75R NEW FH ASSEMBLY 6" DI WATER MAIN CLASS 350 ST A . 2 0 + 0 3 6" 4 5 ° B E N D CL E L 1 5 2 . 1 7 ST A . 2 0 + 1 6 6" 4 5 ° B E N D CL E L 1 5 2 . 0 0 ST A . 1 5 + 9 1 6" X 6 " H Y D R A N T T E E CL E L 1 5 2 . 6 0 ST A . 1 5 + 9 2 . 8 7 6" G A T E V A L V E A N D B O X CL . E L E V . 1 5 2 . 6 1 36 " MI N . 36 " MI N . ST A . 1 8 + 0 3 1° H O R I Z . D E F L E C T T. O . P . E L . 1 5 2 . 6 6 6" DI WATER MAIN CLASS 350 ST A . 2 0 + 0 3 6" 4 5 ° B E N D CL E L 1 5 2 . 1 7 ST A . 2 0 + 1 6 6" 4 5 ° B E N D CL E L 1 5 2 . 0 0 ST A . 1 5 + 9 1 6" X 6 " H Y D R A N T T E E CL E L 1 5 2 . 6 0 ST A . 1 5 + 9 2 . 8 7 6" G A T E V A L V E A N D B O X CL . E L E V . 1 5 2 . 6 1 36 " MI N . 36 " MI N . ST A . 1 8 + 0 3 1° H O R I Z . D E F L E C T T. O . P . E L . 1 5 2 . 6 6 16+00 17+00 18+00 19+00 20+0016+00 17+00 18+00 19+00 20+00 PL O T D A T E : 8/ 1 4 / 2 0 2 5 3 : 2 1 p . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ C I V I L \ C - 0 5 S a v e d b y HP S a v e d a t e : 8/ 1 4 / 2 0 2 5 3 : 1 0 p . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP 10 20'020 1"=20'-0" C-05 CIVIL PLAN AND PROFILE STA 15+15 TO STA 20+26 ST A 1 5 + 1 5 M A T C H L I N E S E E D W G C - 0 4 PLAN 1" = 20' LEGEND CL CONCRETE ELEVATION OVERHEAD ELECTRIC EXISTING STORM SEWER LINE EXISTING SANITARY SEWER LINE EXISTING WATER LINE PROPOSED WATER MAIN EXISTING ELECTRIC LINE EXISTING TELEPHONE LINE EXISTING GAS LINE EXISTING FIBER OPTIC CABLE PROPERTY LINE EASEMENT LINE R/W RIGHT OF WAY CENTERLINE PALM TREE OAK TREE HOLLY TREE PINE TREE UNIDENTIFIED TREE TO BE REMOVED UGE UGT GAS FOC COORDINATE WITH HOMEOWNER ON GRAVEL/SOD DRIVEWAY RESTORATION TO MATCH EXISTING CONDITIONS. REMOVE AND REPLACE GRAVEL DRIVEWAY TO MATCH EXISTING CONDITIONS. REMOVE AND REPLACE GRAVEL DRIVEWAY TO MATCH EXISTING CONDITIONS EXISTING 6" GATE VALVE EXISTING FIRE HYDRANT REMOVE CAP AND BLOW-OFF ASSEMBLY AND CONNECT TO EXISTING 6 INCH DI WATER MAIN W/ MJ SLEEVE REMOVE AND REPLACE GRAVEL DRIVEWAY TO MATCH EXISTING CONDITIONS. 9 CD-02 F L E W E L L I N G A V E N U E CARDINAL STREET REMOVE AND STOCKPILE LANDSCAPING AND TREES REMOVE AND STOCKPILE PAVER BLOCKS REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT 3. 0 ' MI N . KEY PLAN PROFILE 1"=4'-0" VERTICAL 1"=20'-0" HORIZONTAL 150 155 145 140 160 150 155 145 160 621 CARDINAL STREET617 CARDINAL STREET 625 CARDINAL STREET 629 CARDINAL STREET 633 CARDINAL STREET 637 CARDINAL STREET EXISTING GRADE REMOVE, STORE AND REINSTALL SIGN 508 LF OF OPEN CUT CONNECT TO EXISTING WATER MAIN CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) ORANGE AVENUE CARDINAL STREET JAY STREET F L E W E L L I N G A V E N U E CE N T E R S T R E E T 14 CD-02 14 CD-02 14 CD-02 14 CD-02 14 CD-02 14 CD-02 14 CD-02 AREA DEPICTED REPLACE SOD DRIVEWAY 508 LF OPEN CUT ON THIS SHEET 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 632 CARDINAL STREET628 CARDINAL STREET624 CARDINAL STREET 620 CARDINAL STREET 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 NOTES: 1.LOCATION AND ELEVATION OF ALL EXISTING UTILITIES SHOWN ON THESE PLANS ARE TO BE CONSIDERED APPROXIMATE AND SHOULD BE VERIFIED BY CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXISTING UTILITIES AND COORDINATING WITH UTILITY OWNERS DURING CONSTRUCTION. 2.STATIONING IS ALONG CENTERLINE OF PAVEMENT WITH OFFSETS. 3.ALL ASPHALT / CONCRETE SHALL BE SAW CUT WITH STRAIGHT LINES PRIOR TO EXCAVATION. 4.DIMENSIONS AND ELEVATIONS MAY VARY. DIMENSIONS AND ELEVATIONS ARE BASED ON AS-BUILT INFORMATION AND TOPOGRAPHIC SURVEY. 5.CONTRACTOR SHALL PROTECT AND/OR REMOVE AND REINSTALL MAILBOXES, SIGNAGE, FENCING, ETC. AS REQUIRED FOR THE WORK. ANY DAMAGED ITEMS AS A RESULT OF THE WORK SHALL BE REPLACED AT NO COST TO THE OWNER. NOT SHOWN FOR CLARITY. 6.REPLACE ALL SOD AND LANDSCAPING THAT IS DAMAGED DURING CONSTRUCTION AND REPAIR ALL EXISTING IRRIGATION. 7.CONTRACTOR SHALL ASSUME THE EXISTING MAINS ARE NOT RESTRAINED. FOR TIE-INS, EXCAVATE EXISTING PIPE JOINTS, FITTINGS AND VALVES AND RESTRAIN IN ACCORDANCE WITH CITY OF OCOEE ENGINEERING STANDARDS AND DETAILS. 8.ALL NEW MAINS TO BE FULLY RESTRAINED. CITY DETAILS UT004 AND UT005 TO BE USED FOR EXISTING MAINS ONLY. 9.CONTRACTOR SHALL REPLACE ALL SIDEWALK REMOVED FOR THE PROJECT JOINT TO JOINT PER FDOT INDEX 522-001. SIDEWALK REMOVAL LIMITS NOT SHOWN FOR CLARITY. 10.TREES ON PRIVATE PROPERTY TO BE PROTECTED. TREES WITHIN RIGHT OF WAY TO BE PROTECTED. IF TREES WITHIN RIGHT OF WAY CANNOT BE PROTECTED, CONTRACTOR SHALL REMOVE FOLLOWING OWNER APPROVAL. 11.CONTRACTOR SHALL COORDINATE LOCATION OF ALL WATER SERVICES WITH THE CITY. NO SURVEY AVAILABLE FOR SERVICES ON THE WEST SIDE OF THE RIGHT OF WAY. CONSTRUCTION OF WATER SERVICES SHALL INCLUDE NECESSARY PAVEMENT RESTORATION AND MOT. 12.LONG SIDE POLY SERVICES SHALL BE INSTALLED USING TRENCHLESS CONSTRUCTION METHODS TO NOT IMPACT THE ROADWAY. 22+00 23+00 24+00 25+00 26+00 36 " MI N . 36 " MI N . 12 " MI N . 12 " MI N . 12 " MI N . 12 " MI N . 6" DI WATER M A I N C L A S S 3 5 0 ST A . 2 2 + 0 2 6" X 6 " T A P P I N G S L E E V E CL E L 1 4 6 . 2 3 EX I S T . 3 6 " S D IN V E L . 1 3 7 . 5 2 EX I S T . 2 " U G T AP P R O X . T O P E L . 1 4 6 . 8 6 EX I S T . 2 " U G T AP P R O X . T O P E L . 1 5 0 . 3 1 EX I S T . 2 " U G T TO P E L . 1 5 0 . 3 1 ST A . 2 3 + 9 5 1° V E R T . D E F L E C T T. O . P . E L . 1 5 0 . 2 8 ST A 2 2 + 5 6 6" 1 1 . 2 5 ° B E N D CL 1 4 6 . 1 4 ST A 2 2 + 8 2 6" 1 1 . 2 5 ° B E N D CL 1 4 6 . 8 8 22+00 23+00 24+00 25+00 26+00 W W W W W W 6" X 6" TAPPING SLEEVE STA 22+02, 20.08 R 6" GATE VALVE AND BOX STA 22+03, 20.07R 6" 11.25° BEND STA 22+56, 19.18 R 6" 11.25° BEND STA 22+82, 13.78 R STA. 23+95, 13.95R 1° VERT. DEFLECT 6" DI WATER MAIN CLASS 350 PL O T D A T E : 8/ 1 4 / 2 0 2 5 3 : 2 1 p . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ C I V I L \ C - 0 6 S a v e d b y HP S a v e d a t e : 8/ 1 1 / 2 0 2 5 3 : 4 6 p . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP 10 20'020 1"=20'-0" C-06 CIVIL PLAN AND PROFILE STA 22+00 TO STA 26+60 KEY PLAN ORANGE AVENUE CARDINAL STREET JAY STREET F L E W E L L I N G A V E N U E CE N T E R S T R E E T PROFILE 1"=4'-0" VERTICAL 1"=20'-0" HORIZONTAL 150 145 140 155 EXISTING GRADE 135 150 145 140 155 135 459 LF OF OPEN CUT LEGEND CL UGE UGT GAS FOC CONCRETE ELEVATION OVERHEAD ELECTRIC EXISTING STORM SEWER LINE EXISTING SANITARY SEWER LINE EXISTING WATER LINE PROPOSED WATER MAIN EXISTING ELECTRIC LINE EXISTING TELEPHONE LINE EXISTING GAS LINE EXISTING FIBER OPTIC CABLE PROPERTY LINE EASEMENT LINE R/W RIGHT OF WAY CENTERLINE PALM TREE OAK TREE HOLLY TREE PINE TREE UNIDENTIFIED TREE TO BE REMOVED NOTES: 1.LOCATION AND ELEVATION OF ALL EXISTING UTILITIES SHOWN ON THESE PLANS ARE TO BE CONSIDERED APPROXIMATE AND SHOULD BE VERIFIED BY CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXISTING UTILITIES AND COORDINATING WITH UTILITY OWNERS DURING CONSTRUCTION. 2.STATIONING IS ALONG CENTERLINE OF PAVEMENT WITH OFFSETS. 3.ALL ASPHALT / CONCRETE SHALL BE SAW CUT WITH STRAIGHT LINES PRIOR TO EXCAVATION. 4.DIMENSIONS AND ELEVATIONS MAY VARY. DIMENSIONS AND ELEVATIONS ARE BASED ON AS-BUILT INFORMATION AND TOPOGRAPHIC SURVEY. 5.CONTRACTOR SHALL PROTECT AND/OR REMOVE AND REINSTALL MAILBOXES, SIGNAGE, FENCING, ETC. AS REQUIRED FOR THE WORK. ANY DAMAGED ITEMS AS A RESULT OF THE WORK SHALL BE REPLACED AT NO COST TO THE OWNER. NOT SHOWN FOR CLARITY. 6.REPLACE ALL SOD AND LANDSCAPING THAT IS DAMAGED DURING CONSTRUCTION AND REPAIR ALL EXISTING IRRIGATION. 7.CONTRACTOR SHALL ASSUME THE EXISTING MAINS ARE NOT RESTRAINED. FOR TIE-INS, EXCAVATE EXISTING PIPE JOINTS, FITTINGS AND VALVES AND RESTRAIN IN ACCORDANCE WITH CITY OF OCOEE ENGINEERING STANDARDS AND DETAILS. 8.ALL NEW MAINS TO BE FULLY RESTRAINED. CITY DETAILS UT004 AND UT005 TO BE USED FOR EXISTING MAINS ONLY. 9.CONTRACTOR SHALL REPLACE ALL SIDEWALK REMOVED FOR THE PROJECT JOINT TO JOINT PER FDOT INDEX 522-001. SIDEWALK REMOVAL LIMITS NOT SHOWN FOR CLARITY. 10.TREES ON PRIVATE PROPERTY TO BE PROTECTED. TREES WITHIN RIGHT OF WAY TO BE PROTECTED. IF TREES WITHIN RIGHT OF WAY CANNOT BE PROTECTED, CONTRACTOR SHALL REMOVE FOLLOWING OWNER APPROVAL. 11.CONTRACTOR SHALL COORDINATE LOCATION OF ALL WATER SERVICES WITH THE CITY. NO SURVEY AVAILABLE FOR SERVICES ON THE WEST SIDE OF THE RIGHT OF WAY. CONSTRUCTION OF WATER SERVICES SHALL INCLUDE NECESSARY PAVEMENT RESTORATION AND MOT. 12.LONG SIDE POLY SERVICES SHALL BE INSTALLED USING TRENCHLESS CONSTRUCTION METHODS TO NOT IMPACT THE ROADWAY. ST A 2 6 + 6 0 M A T C H L I N E S E E D W G C - 0 7 PLAN 1" = 20' EXISTING 6" PVC WATER MAIN JAY STREET CE N T E R S T R E E T 3. 0 ' MI N . PROTECT UGT EXISTING TREES TO BE PROTECTED (SEE NOTE 10) REMOVE AND STOCKPILE BRICK PAVERS REMOVE AND STOCKPILE BRICK PAVERS REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT 3. 0 ' MI N . 800 CENTER STREET 605 JAY STREET 609 JAY STREET 613 JAY STREET 3. 0 ' MI N . CONTRACTOR TO COORDINATE POLE HOLD CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. 11 CD-02 CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) PROTECT EXISTING VINYL FENCE CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. REMOVE AND REPLACE CONCRETE CURB IN KIND REMOVE, STORE, AND REINSTALL SIGN PROTECT UGT 14 CD-02 14 CD-02 14 CD-02 14 CD-02 14 CD-02 REMOVE AND REPLACE DETECTABLE WARNING PER FDOT INDEX 522-002 704 CENTER STREET 604 JAY STREET 608 JAY STREET 612 JAY STREET REMOVE AND REPLACE ASPHALT PAVEMENT 459 LF OPEN CUT ON THIS SHEET EXISTING LANDSCAPING AND TREES TO BE PROTECTED (SEE NOTE 10) 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 2. 1 3 ' 3. 0 ' MI N . AREA DEPICTED 6" GATE VALVE AND BOX STA 26+78, 13.95R 6" GATE VALVE AND BOX STA 30+58, 16.85R 6" GATE VALVE AND BOX STA 26+76, 16.16R STA. 26+76, 20.12R NEW FH ASSEMBLY STA. 30+58, 21.63R NEW FH ASSEMBLY 6" DI WATER MAIN CLASS 350 27+00 28+00 29+00 30+00 31+00 W W W W W W W STA. 27+61, 13.79R 1° VERT. DEFLECT STA. 29+74, 14.01R 1° VERT. DEFLECT 6" X 6" HYDRANT TEE STA 30+58, 13.77 R6" X 6" HYDRANT TEE STA 26+76, 13.93 R ST A . 2 6 + 7 7 . 8 7 6" G A T E V A L V E A N D B O X CL . E L E V . 1 5 3 . 6 6 36 " MI N . 6" DI WATER MAIN CLASS 350 EX I S T . 2 " U G T AP P R O X . T O P E L . 1 5 3 . 8 3 EX I S T . 2 " U G T AP P R O X . T O P E L . 1 5 3 . 9 7 EX I S T . 2 " U G T AP P R O X . T O P E L . 1 5 3 . 7 2 12 " MI N . 12 " MI N . 12 " MI N . ST A . 2 7 + 6 1 1° V E R T . D E F L E C T T. O . P . E L . 1 5 5 . 0 0 ST A . 2 9 + 7 4 1° V E R T . D E F L E C T T. O . P . E L . 1 5 6 . 0 6 ST A 3 0 + 5 8 6" X 6 " H Y D R A N T T E E CL 1 5 5 . 6 9 ST A 2 6 + 7 6 6" X 6 " H Y D R A N T T E E CL 1 5 3 . 6 3 27+00 28+00 29+00 30+00 31+00 PL O T D A T E : 8/ 1 4 / 2 0 2 5 3 : 2 2 p . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ C I V I L \ C - 0 7 S a v e d b y HP S a v e d a t e : 8/ 1 4 / 2 0 2 5 3 : 1 6 p . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP 10 20'020 1"=20'-0" C-07 CIVIL PLAN AND PROFILE STA 26+60 TO STA 31+52 ST A 2 6 + 6 0 M A T C H L I N E S E E D W G C - 0 6 ST A 3 1 + 5 2 M A T C H L I N E S E E D W G C - 0 8 PLAN 1" = 20' 9 CD-02 9 CD-02 JAY STREET KEY PLAN AREA DEPICTED REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT EXISTING TREES TO BE PROTECTED PROTECT UGT REMOVE AND REPLACE CONCRETE WALK REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT REMOVE AND REPLACE GRAVEL DRIVEWAY TO MATCH EXISTING CONDITIONS. MAILBOX SECURITY CAMERA AND UNDERGROUND ELECTRIC TO BE PROTECTED PROFILE 1"=4'-0" VERTICAL 1"=20'-0" HORIZONTAL 150 160 145 140 155 150 160 145 140 155 617 JAY STREET 621 JAY STREET 625 JAY STREET 629 JAY STREET 633 JAY STREET EXISTING GRADE 489 LF OF OPEN CUT 3. 0 0 ' MI N . CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. ORANGE AVENUE CARDINAL STREET JAY STREET F L E W E L L I N G A V E N U E CE N T E R S T R E E T 14 CD-02 14 CD-02 14 CD-02 14 CD-02 14 CD-02 14 CD-02 14 CD-02 489 LF OPEN CUT ON THIS SHEET 616 JAY STREET 624 JAY STREET 626 JAY STREET 628 JAY STREET 632 JAY STREET 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 11 CD-02 LEGEND CL UGE UGT GAS FOC CONCRETE ELEVATION OVERHEAD ELECTRIC EXISTING STORM SEWER LINE EXISTING SANITARY SEWER LINE EXISTING WATER LINE PROPOSED WATER MAIN EXISTING ELECTRIC LINE EXISTING TELEPHONE LINE EXISTING GAS LINE EXISTING FIBER OPTIC CABLE PROPERTY LINE EASEMENT LINE R/W RIGHT OF WAY CENTERLINE PALM TREE OAK TREE HOLLY TREE PINE TREE UNIDENTIFIED TREE TO BE REMOVED NOTES: 1.LOCATION AND ELEVATION OF ALL EXISTING UTILITIES SHOWN ON THESE PLANS ARE TO BE CONSIDERED APPROXIMATE AND SHOULD BE VERIFIED BY CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXISTING UTILITIES AND COORDINATING WITH UTILITY OWNERS DURING CONSTRUCTION. 2.STATIONING IS ALONG CENTERLINE OF PAVEMENT WITH OFFSETS. 3.ALL ASPHALT / CONCRETE SHALL BE SAW CUT WITH STRAIGHT LINES PRIOR TO EXCAVATION. 4.DIMENSIONS AND ELEVATIONS MAY VARY. DIMENSIONS AND ELEVATIONS ARE BASED ON AS-BUILT INFORMATION AND TOPOGRAPHIC SURVEY. 5.CONTRACTOR SHALL PROTECT AND/OR REMOVE AND REINSTALL MAILBOXES, SIGNAGE, FENCING, ETC. AS REQUIRED FOR THE WORK. ANY DAMAGED ITEMS AS A RESULT OF THE WORK SHALL BE REPLACED AT NO COST TO THE OWNER. NOT SHOWN FOR CLARITY. 6.REPLACE ALL SOD AND LANDSCAPING THAT IS DAMAGED DURING CONSTRUCTION AND REPAIR ALL EXISTING IRRIGATION. 7.CONTRACTOR SHALL ASSUME THE EXISTING MAINS ARE NOT RESTRAINED. FOR TIE-INS, EXCAVATE EXISTING PIPE JOINTS, FITTINGS AND VALVES AND RESTRAIN IN ACCORDANCE WITH CITY OF OCOEE ENGINEERING STANDARDS AND DETAILS. 8.ALL NEW MAINS TO BE FULLY RESTRAINED. CITY DETAILS UT004 AND UT005 TO BE USED FOR EXISTING MAINS ONLY. 9.CONTRACTOR SHALL REPLACE ALL SIDEWALK REMOVED FOR THE PROJECT JOINT TO JOINT PER FDOT INDEX 522-001. SIDEWALK REMOVAL LIMITS NOT SHOWN FOR CLARITY. 10.TREES ON PRIVATE PROPERTY TO BE PROTECTED. TREES WITHIN RIGHT OF WAY TO BE PROTECTED. IF TREES WITHIN RIGHT OF WAY CANNOT BE PROTECTED, CONTRACTOR SHALL REMOVE FOLLOWING OWNER APPROVAL. 11.CONTRACTOR SHALL COORDINATE LOCATION OF ALL WATER SERVICES WITH THE CITY. NO SURVEY AVAILABLE FOR SERVICES ON THE WEST SIDE OF THE RIGHT OF WAY. CONSTRUCTION OF WATER SERVICES SHALL INCLUDE NECESSARY PAVEMENT RESTORATION AND MOT. 12.LONG SIDE POLY SERVICES SHALL BE INSTALLED USING TRENCHLESS CONSTRUCTION METHODS TO NOT IMPACT THE ROADWAY. 6" X 1" SERVICE WET TAP 11 CD-02 6" DI WATER MAIN CLASS 350 CL CL CL 32+00 33+00 33+98 W W STA. 32+45, 13.55R 1° HORIZ. DEFLECT 6" DI WATER MAIN CLASS 350 36 " MI N . EX I S T . 2 " U G T AP P R O X . T O P E L . 1 5 3 . 5 5 12 " MI N . ST A . 3 2 + 4 5 1° H O R I Z . D E F L E C T T. O . P . E L . 1 5 5 . 7 5 32+00 33+00 34+00 PL O T D A T E : 8/ 1 4 / 2 0 2 5 3 : 2 2 p . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ C I V I L \ C - 0 8 S a v e d b y HP S a v e d a t e : 8/ 1 1 / 2 0 2 5 3 : 5 2 p . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP 10 20'020 1"=20'-0" C-08 CIVIL PLAN AND PROFILE STA 31+52 TO STA 34+00 ST A 3 1 + 5 2 M A T C H L I N E S E E D W G C - 0 7 PLAN 1" = 20' REMOVE AND REPLACE GRAVEL DRIVEWAY TO MATCH EXISTING CONDITIONS. EXISTING 6" DI WATER MAIN AND GATE VALVE EXISTING FIRE HYDRANT REMOVE CAP AND BLOW-OFF ASSEMBLY AND CONNECT TO EXISTING 6 INCH DI WATER MAIN W/ MJ SLEEVE JAY STREET F L E W E L L I N G A V E N U E REMOVE AND REPLACE CONCRETE DRIVE JOINT TO JOINT ORANGE AVENUE CARDINAL STREET JAY STREET F L E W E L L I N G A V E N U E CE N T E R S T R E E T KEY PLAN AREA DEPICTED PROFILE 1"=4'-0" VERTICAL 1"=20'-0" HORIZONTAL 150 160 145 140 155 150 160 145 140 155 637 JAY STREET 641 JAY STREET 645 JAY STREET EXISTING GRADE 3. 0 0 ' MI N . 233 LF OF OPEN CUT CONNECT TO EXISTING WATER MAIN CONSTRUCT DOUBLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. 11 CD-02 CONSTRUCT SINGLE WATER MAIN SERVICE WITH TRAFFIC BEARING METER BOXES. CONNECTION WILL BE PROVIDED BY OTHERS. CONTRACTOR TO COORDINATE WITH CITY ON METER LOCATION. (SEE NOTE 12) 11 CD-02 14 CD-02 14 CD-02 233 LF OPEN CUT ON THIS SHEET 6" X 1" SERVICE WET TAP 11 CD-02 6" X 1" SERVICE WET TAP 636 JAY STREET 640 JAY STREET LEGEND CL UGE UGT GAS FOC CONCRETE ELEVATION OVERHEAD ELECTRIC EXISTING STORM SEWER LINE EXISTING SANITARY SEWER LINE EXISTING WATER LINE PROPOSED WATER MAIN EXISTING ELECTRIC LINE EXISTING TELEPHONE LINE EXISTING GAS LINE EXISTING FIBER OPTIC CABLE PROPERTY LINE EASEMENT LINE R/W RIGHT OF WAY CENTERLINE PALM TREE OAK TREE HOLLY TREE PINE TREE UNIDENTIFIED TREE TO BE REMOVED NOTES: 1.LOCATION AND ELEVATION OF ALL EXISTING UTILITIES SHOWN ON THESE PLANS ARE TO BE CONSIDERED APPROXIMATE AND SHOULD BE VERIFIED BY CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXISTING UTILITIES AND COORDINATING WITH UTILITY OWNERS DURING CONSTRUCTION. 2.STATIONING IS ALONG CENTERLINE OF PAVEMENT WITH OFFSETS. 3.ALL ASPHALT / CONCRETE SHALL BE SAW CUT WITH STRAIGHT LINES PRIOR TO EXCAVATION. 4.DIMENSIONS AND ELEVATIONS MAY VARY. DIMENSIONS AND ELEVATIONS ARE BASED ON AS-BUILT INFORMATION AND TOPOGRAPHIC SURVEY. 5.CONTRACTOR SHALL PROTECT AND/OR REMOVE AND REINSTALL MAILBOXES, SIGNAGE, FENCING, ETC. AS REQUIRED FOR THE WORK. ANY DAMAGED ITEMS AS A RESULT OF THE WORK SHALL BE REPLACED AT NO COST TO THE OWNER. NOT SHOWN FOR CLARITY. 6.REPLACE ALL SOD AND LANDSCAPING THAT IS DAMAGED DURING CONSTRUCTION AND REPAIR ALL EXISTING IRRIGATION. 7.CONTRACTOR SHALL ASSUME THE EXISTING MAINS ARE NOT RESTRAINED. FOR TIE-INS, EXCAVATE EXISTING PIPE JOINTS, FITTINGS AND VALVES AND RESTRAIN IN ACCORDANCE WITH CITY OF OCOEE ENGINEERING STANDARDS AND DETAILS. 8.ALL NEW MAINS TO BE FULLY RESTRAINED. CITY DETAILS UT004 AND UT005 TO BE USED FOR EXISTING MAINS ONLY. 9.CONTRACTOR SHALL REPLACE ALL SIDEWALK REMOVED FOR THE PROJECT JOINT TO JOINT PER FDOT INDEX 522-001. SIDEWALK REMOVAL LIMITS NOT SHOWN FOR CLARITY. 10.TREES ON PRIVATE PROPERTY TO BE PROTECTED. TREES WITHIN RIGHT OF WAY TO BE PROTECTED. IF TREES WITHIN RIGHT OF WAY CANNOT BE PROTECTED, CONTRACTOR SHALL REMOVE FOLLOWING OWNER APPROVAL. 11.CONTRACTOR SHALL COORDINATE LOCATION OF ALL WATER SERVICES WITH THE CITY. NO SURVEY AVAILABLE FOR SERVICES ON THE WEST SIDE OF THE RIGHT OF WAY. CONSTRUCTION OF WATER SERVICES SHALL INCLUDE NECESSARY PAVEMENT RESTORATION AND MOT. 12.LONG SIDE POLY SERVICES SHALL BE INSTALLED USING TRENCHLESS CONSTRUCTION METHODS TO NOT IMPACT THE ROADWAY. W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W WW W W W WW WW W W WW W W W W WW W W W W W W W W PL O T D A T E : 8/ 1 4 / 2 0 2 5 3 : 2 3 p . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ C I V I L \ C - 0 9 S a v e d b y HP S a v e d a t e : 8/ 1 1 / 2 0 2 5 3 : 5 8 p . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP 100'0100 1"=100'-0" 50 C-09 CIVIL EXISTING 2-INCH WATER MAIN ABANDONMENT LIMITS PLAN 1" = 100' CA R D I N A L S T R E E T JA Y S T R E E T CENTER STREET OR A N G E A V E N U E EXISTING 2" WATER MAIN ABANDONMENT LIMITS (ABANDON IN PLACE) (SEE NOTES) EXISTING 2" WATER MAIN ABANDONMENT LIMITS (ABANDON IN PLACE) (SEE NOTES) EXISTING 2" WATER MAIN ABANDONMENT LIMITS (ABANDON IN PLACE) (SEE NOTES) FLEW E L L I N G A V E N U E NOTES: 1.CONTRACTOR SHALL COORDINATE WITH CITY OF OCOEE FOR ABANDONMENT/REMOVAL OF WATER METERS. 2.WATER MAIN ABANDONMENT SHALL BE COMPLETED AFTER THE NEW WATER MAIN, WATER SERVICES AND WATER METERS HAVE BEEN CONSTRUCTED AND CLEARED FOR SERVICE. 3.EXISTING WATER MAIN AND WATER METER LOCATIONS ARE NOT SURVEYED AND ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM LOCATIONS PRIOR TO BEGINNING WORK. CUT AND CAP 2-INCH WATER MAIN CUT AND CAP 2-INCH WATER MAIN CUT AND CAP 2-INCH WATER MAIN HI L L A V E N U E CUT AND CAP 2-INCH WATER MAIN CUT AND CAP 2-INCH WATER MAIN DETAIL NTS 1 - DETAIL NTS 2 - DETAIL NTS 3 - CD-01 CITY STANDARD DETAILS SHEET 1 Typical Cross Section Stage 1 Stage 2 Varies Straight and Smooth Saw Cut Existing Surface Treatment Extent of Pavement Replacement Replacement Base 1/2 of Pipe Diameter or 1' Min. 18"6" Curb Stage Compactions: 1.Backfilling of trench shall be in six inch (6") maximum lifts. 2.Stage 1: Backfilling trench in Stage 1 shall use proper mechanical equipment to insure proper compaction throughout, including pipe haunches. 3.Stage 2: Backfilling trench in Stage 2 shall be to bottom of sub-grade. NOTES: 1.All work and material for the Flexible Pavement Reconstruction shall be in accordance with the most current City of Ocoee - Engineering Standards Manual (available at OCOEE.ORG). 2.Any conflict between ESM specification and this sheet's specifications shall be resolved by the more stringent requirement. 3.Replacement asphalt shall match the existing structural and friction courses for type and thickness in accordance with requirements as set forth by the ESM. 4.Replacement asphalt shall be installed the to the full width of the travel lane. 5.Backfill and base material shall be clean and homogenous compacted to 98% of the maximum density per AASHTO T-180. Tack shall be added to the new base material prior to installing the replacement asphalt. 6.Base course shall be prepared in 6" lifts maximum, and thoroughly compacted. 7.Where trench line abuts existing curb(s), construct clean butt joint with curb. In the event curb is undermined and/or compromised, curb shall be replaced. Butt-Joint Detail CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:July 2022 N/A PW002 DETAIL NO. Open Cut Flexible Pavement Replacement CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:July 2022 N/A PW003 DETAIL NO. Driveway Approach Right-of-Way Line Driveway Roadway Curb & Gutter 1 2 3 4 3 5 1 Legend Driveway: approach and sidewalk 6" Thick - fc' = 3,000 psi @ 28 days, fiber reinforced concrete 2 Sidewalk: 4" Thick - fc' = 3,000 psi @ 28 days 3 Expansion Joint: bituminous fiber board material 1/2" thick and full depth 4 Construction Joint: tooled, dummy or sawed (1" depth minimum, spacing equal width of sidewalk) 5 Approach Transition: Flair Curb shall be dropped if not mountable Curb shall be dropped through driveway with 3' transitions each end of driveway for non-mountable curb. All wooden stakes used in form work if left in place, shall have 2" or more of concrete cover. Notes: NOTES: 1. Pipe bedding material and trench backfill shall be select common (clean) fill compacted to 95% (98% in roadway) of the maximum density as per AASHTO T-180. 2. Contractor shall install crushed rock (or equivalent bedding material) where pipe bedding does not provide solid support (yielding or plastic). Depth of material shall be a minimum of 6", or as needed, to provide non-yielding support for the pipe. All unsuitable material shall be removed from pipe bedding unless special provisions are approved by the City. 3. Excavated trench width at pipe haunch shall be sufficient in size for haunch compaction, but shall be no greater than 15" on each side of pipe for pipes less than 24" in diameter (24" for pipes 24" in diameter or greater.) 4. Water shall not be permitted in trench line during construction. 5. Pipe line shall be installed with bell fitting facing upgrade. 6.Gravity sewer shall have a 6" minimum rock bed. Crown trench in unimproved areas (3" min.) Clean Fill Undisturbed Earth 12" (typ.) Trench Width Varies Based on Pipe Dia. Existing Grade Pi p e B e d d i n g Tr e n c h B a c k f i l l Rock Bedding (See Notes 2 and 6) Pipe Diameter *a *a See Note 3 *a CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:September 2019 N/A UT001 DETAIL NO. Pipe Bedding and Trench DETAIL NTS 4 - NOTES: 1.The restraint values as indicated by the "Restraint Table" are minimum values.Design engineer shall be responsible for confirming field conditions, and make adjustments accordingly. 2.All fittings shall have restrained joints unless otherwise indicated. 3.No restraints required if continuous pipe length is greater than value provided in "Restraint Table" above. 4.Where two or more fittings are laid in-line, use greatest restraint length for coverage. 5.For in-line valves and through run of tees: outside limits of restrained joints from other fittings need not be restrained unless otherwise indicated. 6.Lengths shown in the table have been calculated in accordance with the procedures outlined in "Thrust Restraint Design for Ductile Iron Pipe" as published by DIPRA, with the following assumptions: Working Pressure: 150 PSI Soil Designation: SM (Silty Sand, Sand-Silt Mix.) Laying Conditions: 5 7.For pipe encased in polyethylene, use values given in parentheses or increase the given value by 150%. 8.For pipe sizes not included in the Restraint Table or pipe material not adhering to given conditions, design engineer shall determine and specify pipe lengths which shall be approved by the City. 4"6"8"10"12"16" 15 21 27 32 37 47 7 5 11 13 16 20 5 5 6 7 8 10 5 5 5 5 5 6 30 47 64 81 98 133 Fittings Pipe Size D.I.P. Restraint Table 90° Bend 45° Bend 22 1/2° Bend 11 1/4° Bend Plug or Branch of Tee Minimum Length (FT) to be Restrained on Each Side of Fitting(s) CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:April 2019 N/A UT005 DETAIL NO. Ductile Iron Pipe Restraint Table NOTES: 1.PVC extensions shall not be used on valve box. 2.The actuating nut for valves shall be no deeper than 24" from ultimate finished grade. 3.Valve assembly shall include center spacing guide from the City's Approved Materials List. 4.Where valve nut is more than 36" below grade, valve assembly shall include an extension from the City's Approved Materials List. 5.Valve collar shall be 24" x 24" x 6" square pad and concrete for collar shall be fc' of 3,000 psi minimum @ 28 days for non-pavement areas. 6.Valve Marker shall be from the City's Approved Materials List and shall include "City of Ocoee", main type, size, material, turns to open or close valve, and direction of rotation. 7.Valve Box shall not be located in pavement, sidewalk, or driveway unless approved by the City. If approved, Contractor/Developer shall reach out to the Utilities Department on the location of the Valve Tags. 8.For Valve Box approved in pavement, a disk valve marker shall hang in the valve box anchored to the locating wire. Pipe/Main 6" FDOT #57 Stone Valve Adjustment Ring Actuating Nut for Valve Concrete Collar (See note 5) Finished Grade Adjustable cast iron valve box Valve box shall rest on bedding rock, not on valve or pipe, and shall be centered on operating nut. Valve I.D. Marker (See note 6) ##"DIP CCW OP E N ##T U R N S W A T E R MAI N 24" 24" 12" #4 bar with 2" minimum concrete cover CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:June 2021 N/A UT009 DETAIL NO. Valve Box and Cover ##"DIP CCW OP E N ##T U R N S W A T E R MAI N 1 4" See Note 8: C I T Y OF OCOE E C I T Y OF OCOE E DETAIL NTS 5 - DETAIL NTS 6 - DETAIL NTS 7 - DETAIL NTS 8 - Main (type) PIPE LETTERING NOTES: 1.Lettering shall be per the American Water Works Association. 2.Lettering shall be a minimum of 3/4" in height and shall be be facing up when the pipe is installed. 3.Lettering must be permanently imbedded into the pipe/main, not painted or stenciled. 4.Lettering shall be of contrasting color to pipe/main color. Pipe/Main color based on use. Main (type) See Note 2 for lettering size and orientation. Pipe Marking (Lettering) N.T.S. Diameter = 2.5" to 4" 3" Tape centered along the top half of pipe. Main (type)Main (type)Main (type) Diameter = 6" to 16" Two (2) 6" Tapes along both sides of top half of pipe. Main (type)Main (type)Main (type) Main (type)Main (type) Main (type)Main (type)Main (type) Main (type)Main (type) Main (type)Main (type)Main (type) Diameter = 20" and larger Three (3) 6" Tapes along top and both sides of top half of pipe. Warning Tape N.T.S. WARNING TAPE NOTES: 1.Tape color shall be in accordance with (same) as main/pipe color. 2.Tape lettering shall be at least 1" in height with no greater than 12" in spacing. 3.Warning tape shall extend total length of pipe. Main (type) Main (type) CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:April 2019 N/A UT011 DETAIL NO. Pipe Identification & Warning Tape 4"6"8"10"12"16" 18 24 32 38 44 55 10 10 13 16 18 23 10 10 10 10 10 11 10 10 10 10 10 10 30 47 64 81 98 133 Fittings Pipe Size PVC/HDPE Restraint Table 90° Bend 45° Bend 22 1/2° Bend 11 1/4° Bend Plug or Branch of Tee Minimum Length (FT) to be Restrained on each side of Fitting(s) NOTES: 1.The restraint values as indicated by the "Restraint Table" are minimum values. Design engineer shall be responsible for confirming field conditions, and make adjustments accordingly. 2.All fittings shall have restrained joints unless otherwise indicated. 3.No restraints required if continuous pipe length to fitting is greater than value provided in "Restraint Table" above. 4.Where two or more fittings are laid in-line, use greatest restraint length for coverage. 5.For in-line valves and through run of tees: outside limits of restrained joints from other fittings need not be restrained unless otherwise indicated. 6.Lengths shown in the table have been calculated in accordance with the procedures outlined in "Thrust Restraint Design for Ductile Iron Pipe" as published by DIPRA, with the following assumptions: Working Pressure: 150 PSI Soil Designation: SM (Silty Sand, Sand-Silt Mix.) Laying Conditions: 5 7.For pipe sizes not included in the Restraint Table or pipe material not adhering to given conditions, design engineer shall determine and specify pipe lengths which shall be approved by the City. 20" 74 31 15 10 167 CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:April 2019 N/A UT004 DETAIL NO. PVC/HDPE Pipe Restraint Table PL O T D A T E : 8/ 1 4 / 2 0 2 5 3 : 2 3 p . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ C I V I L \ C D - 0 1 S a v e d b y OS C A R S a v e d a t e : 6/ 1 0 / 2 0 2 5 3 : 2 6 p . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:JUNE 2020 N/A PW005 DETAIL NO. Sidewalk, Curb, and Pavement Detail NOTES: 1.Tooled Control Joints at 5' O.C. max. 2.Expansion Joints at 25' O.C. max. 3.Joints shall be constructed within 24 hours of pouring concrete 4.Sidewalks shall be Class I, 3000psi 5.Sub-grade or base shall be compacted to a minimum density of 98% of the maximum density as determined by AASHTO T-180 for sidewalks/bike paths and curbs. 6.Refer to plans for sidewalk width. Sidewalk shall be a minimum of 5' if a width is not specified on the plans. 7.Refer to the plans for the curb height. If no curb height is specified, use 6" 4" 4" Concrete over compacted fill. 1/4" Per Foot Cross Slope 1" Prior to seeding or planting 2" Prior to sodding See Note 6 6" See Note 7 CD-02 CITY STANDARD DETAILS SHEET 2 Hose Nozzle Pumper Nozzle Facing Street Hydrant Operating Nut 6" Bedding Rock 18" Min. Above Finished Grade 24" MJ Hydrant Anchoring Tee CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:June 2021 n/a UT201 DETAIL NO. Fire Hydrant Assembly Resilient Seat Gate Valve and Box (See Detail UT009) 36 " M i n . Compacted Backfill Maximum 6" Clearance Between Concrete and Bottom of Nuts/Bolt 3 ' to 5 ' Expansion Fiber Material (TYP) Concrete Sidewalk Note: 1.Hydrants shall be painted with double coat enamel paint per the following: ·Public Potable Water - Safety Yellow Pantone 13-0630TN ·Reclaimed Water - Purple Pantone 522 C ·Private Fire - Cherry Red HDC-MD-16 2.Concrete shear pad shall abut between sidewalk and curb. Where sidewalk is not present, concrete shear pad shall be approx. 7.5' x 3.5' min. 3.Concrete shall be 6" thick with fibermesh and shall be fc' of 3,000 psi minimum at 28 days. 4.Any deviation from this detail shall be made known to the City for approval. W W Standard Configuration Alternate Configuration Edge of Pavement Edge of Pavement Sidewalk Sidewalk Water/Reclaim Main Water/Reclaim Main Fire Hydrant Assembly Fire Hydrant Assembly 90° Bend DETAIL NTS 9 - DETAIL NTS 10 - DETAIL NTS 11 - DETAIL NTS 12 - DETAIL NTS 13 - DETAIL NTS 14 - DETAIL NTS 15 - DETAIL NTS 16 - Stainless Steel Tapping Sleeve NOTES: 1.All Sleeves and Valves shall be water tested before tap. 2.No Wet Tap on Asbestos Cement water mains. 3.For Valve Box and Cover, see Ocoee UT009 Valve Box and Cover Detail. Resilient Seat Tapping Valve Test PlugRestrained Mechanical Joint New Main Active Main Flange Gasket CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:Feb. 2020 N/A UT205 DETAIL NO. Stainless Steel Tapping Saddle and Gate Valve Assembly Water and Reclaim NOTES: 1.All fittings shall be brass with compression-pack joint type connections. 2.No service line shall extend or terminate under a driveway. 3.Meter end of service shall terminate with curb stop (90°) for single service and dual horn and curb stops (90°)for dual services. 4.Meter end of service shall terminate 3' past meter location where service shall, unless directed otherwise, extend 3' above finished grade tied to a 2" x 4" x 4' stake. If directed, service connection shall be buried and located with an 2" x 4" x 4' painted marker. Stake or marker shall indicate lot(s) to be served. 5.Concrete curb shall be marked (stamped or saw-cut) with "W" locating service. 6.Service connection to the main shall use approved saddle, and tapping of main shall be by a method where a solid coupon is removed. 7.Services installed under finished or existing pavement shall be directionally drilled. 8.Upon approval, direct tap (no saddle) may be used on Ductile Iron Pipe. 9.Service color shall be blue for potable water and purple (magenta) for reclaimed water. Tapping Section WA T E R M A I N AWWA Type CC Threads #10 THHN Tracing Wire, Color to Match Service Water Main Corporation Stop (Ford F1000-4NL) & Fittings (normally open) Service, Polyethylene Tubing, 1" min. To Meter/Box Assembly Double Strap Stainless Steel Saddle 30° to 45° Service View with Single Meter Double Meter ConfigurationSingle Meter Box and Water Meter (By City) Coil Excess Tracing Wire in Box Service Polyethylene Tubing Curb Stop (See Note 3) #10 THHN Tracing Wire to Match Use in Color Brass Corporation Stop (1" Min.) Double Meter Box and Water Meter (By City) 90° Angled Curb Stops at Ends of Horn U-Branch Brass Horn (1" x 3/4" x 3/4") Installed Upright CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:Sep. 2019 N/A UT206 DETAIL NO. Water and Reclaim Service Connection NOTES: 1.Pipes/mains in this detail are for representation purposes only. Refer to plan or utility sheets for pipes/main material, size, and configuration. 2.For meter configuration, including fittings and box, see City of Ocoee Meter and Meter Box Details UT207 for Single Family and UT208 for Commercial/Multi-Family. 3.Unless directed by City, reclaimed and potable meter boxes shall be separated by placing the boxes at opposite property lines. 4.Meters should be centered in grassed parkway, if possible, offset from front of sidewalk 2', and such that private service will not cross adjacent lot. Meter Location Plan View Pipe/Main Property Lined Right-of-Way Single Service Double Service Single Service (typ.)Single Service (typ.) Sidewalk Curb Typical Meter Layout Right-of-Way Line Sidewalk Grassed Parkway Main Curb Private Services CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:April 2019 N/A UT207 DETAIL NO. Meter & Service Locations PL O T D A T E : 8/ 1 4 / 2 0 2 5 3 : 2 3 p . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ C I V I L \ C D - 0 2 S a v e d b y OS C A R S a v e d a t e : 6/ 5 / 2 0 2 5 5 : 3 9 p . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP NOTES: 1.Water Service shall be 1" diameter P.E. minimum. 2.Service curb stop shall be bullet locked using High Field Manufacturing Cap Seal # 93210130, Bullet Stud 93210140 and Base 93210120. 3.Service shall extend 4' above finished grade and shall be no more than 2' from back of curb. 4.Top of stake shall be painted the color of the Utility Service and labeled with the Lot Number(s)/Address(es) it serves. 5.When water service will be used for Bacteriological Testing, a hose bib shall be installed on the Curb Stop. 6.Meter shall be installed by the City unless authorization has been given by the City (UT208b) 7.Private connection to the meter shall be the responsibility of the Owner/Owner's Contractor. 90° Compression Curb Stop Fitting Ford KV43-342W-NL Service from Main (P.E.) Double Meter Curb Stop Service from Main (P.E.) Dual Horn Brass with 90° Curb Stops (Ford UV43-42W-NL) Bullet Lock CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:June 2021 N/A UT208a DETAIL NO. Single Family Residential Service Single Meter Curb Stop Weather Protected Heavy Duty Tape 2" x 3" x 5' Wooden Stake Curb Existing Grade Sidewalk 6" minimum below grade NOTES: 1.Provide temporary pipe supports as required. 2.Do not use galvanized pipe or accessories. Polyethylene pipe can be used with approval by the City 3.A temporary jumper connection is required at all connections between existing active water mains and proposed new water main improvements. 4.The detail shown is to be used for filling any new water main of any size from existing active water mains and for flushing of new mains up to 8" diameter (2.5 fps min velocity) and for pulling bacteriological samples from any new water main of any size. 5.The jumper connection shall be maintained until after filling, flushing, testing, and disinfection of the new main has been successfully completed; and clearance for use from Florida Department of Environmental Protection (FDEP) and other pertinent agencies has been received. 6.Pipe and fittings used for connection of the new pipe to the existing pipe shall be disinfected prior to installation in accordance with AWWA C651, 2014 edition. 7.Swab or spray the exterior of the main to be tapped and the tapping saddle with 1% Hypochlorite solution. 8.The contractor shall reach out to the City to rent a City Hydrant Meter Assembly. 9.All installation and maintenance of the temporary jumper connection and associated hydrant meter assembly, fittings and valves, etc., shall be the responsibility of the contractor. CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:March 2020 N/A UT211 DETAIL NO. Temporary Jumper Connection Threaded Nipple Final Grade 2" Corporation stop (TYP.) Existing Main 2" Service Saddle (TYP.) 12" Min Hydrant Meter Assembly 90° Bend 2" Pipe 2" Ball Corp Stop New Main Tie in valve shall be closed and Locked. City of Ocoee to be provided locking mechanism. Valve shall be operated by City of Ocoee personnel only. NOTES: 1.This detail shall only be used when the Contractor/Developer has been given special permission by the City to place City Meters. 2.Water Service shall be 1" diameter P.E. minimum. 3.Service curb stop shall be bullet locked using High Field Manufacturing Cap Seal # 93210130, Bullet Stud 93210140 and Base 93210120. 4.Private connection to the meter shall be the responsibility of the Owner/Owner's Contractor. Side Single Meter View Reclaimed Meter Connection Use Brass Meter Connection (substitute for Dual Check Valve.) Meter Box MXU (FlexNet Radio Unit) Meter Existing Grade Private Connection 3/4" Brass Meter Connection 90° Compression Curb Stop Fitting Ford KV43-342W-NL Service from Main (P.E.) Dual Check Valve (Potable Water), Ford HHCH31-323-NL Dual Meter Front ViewService from Main (P.E.) Dual Horn Brass with 90° Curb Stops, Ford UV43-42W-NL Bullet Lock CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:February 2021 N/A UT208b DETAIL NO. Single Family Residence Meter Configuration NOTES: 1.The table above represents the minimum separation requirements as described in the City's Engineering Standards Manual. The most stringent requirements between the City's Standards and the guidelines set forth in the Florida Administrative Code 62-555.314 (F.A.C). shall apply between newly proposed utility lines and existing or proposed utility lines. 2.Joint spacing shall be based on one full length water main pipe centered above or below other pipes. The joint shall be no less than the required distance from the center of the crossing of the two pipes. (The water pipe shall be above the other pipe unless otherwise approved by the City.) 3.Where the City's minimum vertical and horizontal separation from potable water cannot be achieved from the outside of the potable water pipe and the outside of the other pipe/main, preferred separation in accordance with F.D.E.P. rules of the Florida Administrative Code 62-555.314 (F.A.C.) and 62-604.400 (F.A.C.) may be allowed upon approval by the City's Utilities Department. a.If it is not technically feasible or economically sensible to comply with the requirements set forth in 62-555.314 (F.A.C.), technical or economic justification for each exception must be submitted to F.D.E.P. with alternative construction features. Proof of F.D.E.P.'s approval for exceptions shall be submitted to the City. 4.For the purpose of this table, reclaimed water shall mean unrestricted public access reuse water as defined by F.A.C. 62-610. Other types of reclaimed water, not treated to public contact levels, shall be considered raw sewage, and the separation list for sanitary sewer shall apply. 5.Alternative water, such as storm water used for irrigation, shall be considered reclaimed water for separation requirements. 6.Pipe separation distance provided above shall mean the horizontal and/or vertical distance measured for the outside dimension of each pipe/main. 7.All Sanitary and Storm Structures shall follow separation requirements above. 8.Potable water pipes shall be laid above all pipes conveying raw sewage whenever they cross. 9.All utilities shall be installed with 36" of cover over the top of pipe. Cover shall be measured with current or future grading to ensure the 36" coverage. 10.No potable water pipe may pass through a sanitary sewer structure. Penetration through storm sewer must be approved by the City and is subject to special conditions and materials. 11.Structural shall refer to foundations, walls, etc. Additional separation shall be required by the City for construction of, including, but not limited to: live loads, multi-story commercial buildings, superstructures, embankments, retaining walls, bridges, railroads, high voltage transmission mains, gas mains, etc. Pipes/Mains Separation Requirement Table (See Note 11 for Structural) Potable Reclaimed Sanitary Sewer Storm Sewer Potable Reclaimed Horiz.Vert.Horiz.Vert.Horiz.Vert.Horiz.Vert. Sanitary Sewer Storm Sewer 3'12"3' 3'3'3' 3'3' 3'3'3' 18"18" 12" 12" 12" 12" 12" 12" 18" 18" 10' 12" 10' CONSTRUCTION DETAILS CITY OF OCOEE SCALE:DATE:November 2022 N/A UT013 DETAIL NO. Pipe Separation Requirement Table Joint Spacing Requirement Table (See Note 2) Potable Reclaimed Sanitary Sewer Storm Sewer Potable 3'3'6' Horiz. 10' Structural 10' 10' 10' D-01 STANDARD DETAILS FRAME & LID TO BE REMOVED ABANDONED EXISTING VALVE TO REMAIN IN PLACE VALVE BOX TO BE REMOVED CONC. COLLAR TO BE REMOVED TURN VALVE TO OPENED POSITION RESTORE TO EXISTING CONDITIONS 1. EXISTING MAIN LINE VALVES SHALL BE ABANDONED AS FOLLOWS: BACKFILL AND SURFACE RESTORATION PER TRENCH DETAILS 1.2 GRASS AREAS = REMOVE UPPER SECTION OF VALVE BOX, BACKFILL AREA, COMPACT TO SPECIFICATION (95% DRY DENSITY MIN.) AND REPLACE SOD. 1.1 PAVED AREAS = REMOVE VALVE BOX AND FILL WITH CONCRETE TO FLUSH WITH PAVEMENT BASE. SAW CUT PAVEMENT AND INSTALL ASPHALT PATCH. NOTES: EXISTING TREE * * ROOT PRUNING NOTES: EXISTING GRADE 1.ALL TREE AND ROOT PRUNING SHALL BE PERFORMED ACCORDING TO THE ANSI A300 ROOT PRUNING STANDARDS AND SHALL BE DONE BY AN INTERNATIONAL SOCIETY OF ARBORICULTURE (ISA) CERTIFIED ARBORIST LICENSED IN FLORIDA. PRUNING OPERATORS SHALL MEET WITH THE ENGINEER/OWNER PRIOR TO ANY PRUNING. 2.CUTS ARE TO BE MADE CLEANLY WITH A SHARP ROOT PRUNING TOOL (SUCH AS A DOSCO OR VERMEER ROOT PRUNER). 3.INSTALL ORANGE PLASTIC MESH TREE BARRIER, WITH REBAR SUPPORTS, AT POINT OF PRUNING AND CONTINUE COMPLETELY AROUND TREE, PROTECTING THE AREA WITHIN THE DRIP LINE (EXTENT OF OUTER BRANCHES). POINT AT WHICH ROOTS ARE PRUNED PRIOR TO EXCAVATION IF WITHIN 6' OF TRUNK CONSULT PROJECT ENGINEER DEPTH OF EXCAVATION ROOT BARRIER NOTES: 1.ROOT BARRIER IS REQUIRED FOR LOCATIONS WHERE TREE(S) AND/OR ASSOCIATED ROOTS ARE LOCATED WITHIN 10 FEET OF A REQUIRED IMPROVEMENT. 2.ROOT BARRIER SHALL BE INSTALLED 15 FEET ON CENTER OF TREES AND/OR ROOTS. 3.ROOT BARRIER SHALL BE MINIMUM 48" DEEP. ROOT BARRIER MATERIAL SHALL BE HDPE OR AS APPROVED BY ENGINEER. 4' MIN PROPOSED PIPE CO V E R (S E E P L A N S ) ROOT BARRIER (SEE NOTES) DETAIL EXISTING VALVE ABANDONMENT NTS 17 - DETAIL ROOT PRUNING AND ROOT BARRIER DETAIL NTS 18 - PL O T D A T E : 8/ 1 4 / 2 0 2 5 3 : 2 3 p . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ C I V I L \ D - 0 1 S a v e d b y HP S a v e d a t e : 6/ 2 6 / 2 0 2 5 9 : 2 4 a . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP 1. EXIST GATE VALVE SHALL BE CLOSED PRIOR TO ABANDONING. 2. EXIST HYDRANTS SHALL NOT BE REMOVED FROM SERVICE PRIOR TO PLACING NEW HYDRANTS INTO SERVICE. 3. ALL MATERIALS REMOVED SHALL BE PROPERLY DISPOSED OF BY THE CONTRACTOR. OWNER MAINTAINS RIGHT TO SALVAGE MATERIAL. 6. WHEN EXISTING HYDRANT IS PRESENT IN AN EXISTING SIDEWALK, SAW CUT, AND REMOVE THE EXISTING SIDEWALK AND CURB AT JOINTS AND RESTORE AREA TO CONDITION EXISTING PRIOR TO HYDRANT REMOVAL. EXIST HYDRANT TO BE REMOVED (SEE NOTE 2) LEGEND EXISTING PROPOSED TO BE REMOVED. INSTALL MJ RESTRAINED PLUG IF EXISTING WM TO REMAIN IN SERVICE (SEE NOTE 4) 7. CONTRACTOR SHALL COORDINATE GROUT FILL/ABANDONMENT OF WATER MAIN WITH FIRE HYDRANT REMOVAL/DISPOSAL, AS APPLICABLE. 4. POUR THRUST BLOCK BEHIND NEW PLUG OR CAP IF EXISTING PIPING IS UNRESTRAINED AND MAIN WILL REMAIN IN SERVICE. ALTERNATIVELY, RESTRAIN VALVE TO TEE. EXIST MAIN 5. UNTIL FIRE HYDRANT IS PHYSICALLY REMOVED, ANY HYDRANT THAT BECOMES NON-USABLE SHALL BE COVERED AND MARKED "ABANDONED". NOTES: EXIST VALVE BOX AND SETTING TO BE REMOVED EXIST GATE VALVE TO REMAIN (SEE NOTE 1) BACKFILL AND SURFACE RESTORATION PER TRENCH DETAILS REMOVE EXIST PIPE REMOVE BOLLARDS IF PRESENT RESTORE TO EXISTING CONDITIONS DETAIL EXISTING FIRE HYDRANT REMOVAL NTS 19 - D-02 POLLUTION PREVENTION DETAILS BALE W I D E 18" TY P . 4" MI N . BALE L E N G T H 36" TY P . BACK F I L L A N D C O M P A C T EXCA V A T E D T R E N C H S O I L BIND I N G W I R E O R T W I N E FLOW BALE WIDTH 18" TYP. 2"x2"X48" STAKES BACKFILL AND COMPACT EXCAVATED TRENCH SOIL FLOW 4" MIN. 30 " M I N . 18 " T Y P . SECTION NTS A - NOTE: ANCHOR HAY BALES WITH 2-2"x2"X48" STAKES PER BALE. HAY BALE INSTALLATION NOTES: 1.SEE CIVIL PLAN VIEW FOR LOCATIONS OF HAY BALES. 2.HAY BALES SHALL CONSIST OF CERTIFIED WEED FREE STRAW OR HAY LOCAL JURISDICTIONS MAY REQUIRE PROOF THAT BALES ARE WEED FREE. 3.HAY BALES SHALL CONSIST OF APPROXIMATELY 5 CUBIC FEET OF STRAW OR HAY AND WEIGH NOT LESS THAN 35 POUNDS. 4. WHEN HAY BALES ARE USED IN SERIES AS A BARRIER, THE END OF EACH BALE SHALL BE TIGHTLY ABUTTING ONE ANOTHER. 5. HAY BALE DIMENSIONS SHALL BE APPROXIMATELY 36" X 18" X 18". 6.A UNIFORM ANCHOR TRENCH SHALL BE EXCAVATED TO A DEPTH OF 4". BALES SHALL BE PLACED SO THAT BINDING TWINE OR WIRE IS HORIZONTALLY ENCOMPASSING THE SIDES OF THE BALE(S). ALL EXCAVATED SOIL SHALL BE PLACED ON THE UPHILL SIDE OF THE BALE(S) AND COMPACTED. 7.TWO (2) WOODEN STAKES SHALL BE USED TO HOLD EACH BALE IN PLACE. WOODEN STAKES SHALL BE 2" X 2" X 48". WOODEN STAKES SHALL BE 30" INTO THE GROUND. 50 100 150 200 250 300 350 4000 1 2 3 4 5 6 SPACING (In Feet) CHART 1: SILT FENCE SPACING SL O P E ( I n % ) TYPE III SILT FENCE 6' MAX. 12 " M I N . 15 " TO 1 8 " 8" 3' O R M O R E ELEVATION SECTION GROUND SURFACE POST OPTIONS SOFTWOOD 2 1/2" DIA. SOFTWOOD 2" x 4" HARDWOOD 1 1/2" x 1 1/2" STEEL 1.33 LBS / FT FILTER FABRIC (IN CONFORMANCE WITH SEC. 985 FDOT SPEC.)20°± VE R T I C A L FILTER FABRIC SILT FLOW OPTIONAL POST POSITIONS PRINCIPLE POST POSITION (CANTED 20° TOWARD FLOW) NTS TYPE III SILT FENCE NTS HAY BALE PROTECTION AROUND INLETS OR SIMILAR STRUCTURES FILTE R F A B R I C FDOT # 1 C O A R S E A G G R E G R A T E R = 2 0 ' 0 " HARD S U R F A C E P U B L I C R O A D 12'- 0 " ( M I N . ) 6" MINIMUM THICKNESS 10'50' M I N I M U M NOTES: 1.THE ENTRANCE SHALL BE MAINTAINED A CONDITION THAT WILL PREVENT TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHTS-OF-WAY. THIS MAY REQUIRE TOP DRESSING. REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. 2.WHEN NECESSARY , WHEELS SHALL BE CLEANET PRIOR TO ENTRANCE ONTO PUBLIC RIGHT-OF-WAY. 3.WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN AREA STABLIZED WITH CRUSHED STONE THAT DRAINS INTO AN APPROVED SEDIMENT TRAP OR SEDMENT BASIN. PL O T D A T E : 8/ 1 4 / 2 0 2 5 3 : 2 4 p . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ C I V I L \ D - 0 2 S a v e d b y OS C A R S a v e d a t e : 6/ 4 / 2 0 2 5 1 1 : 5 9 p . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP D-03 MATERIAL QUANTITY TABLE PL O T D A T E : 9/ 3 / 2 0 2 5 1 0 : 1 1 a . m . B Y : HP Fi l e : C: \ U S E R S \ H P \ D C \ A C C D O C S \ H A Z E N A N D S A W Y E R \ 4 1 1 5 4 - 0 0 4 _ F L E W E L L I N G 2 - I N C H W M R E P \ P R O J E C T F I L E S \ 0 1 _ D E S I G N \ C I V I L \ D - 0 3 S a v e d b y HP S a v e d a t e : 9/ 3 / 2 0 2 5 1 0 : 1 0 a . m . MELANIE PECKHAM PE. No. 66487 FLEWELLING 2-INCH WATER MAIN REPLACEMENT CITY OF OCOEE UTILITIES DEPARTMENT 41154-004 AUGUST 2025M. PECKHAM IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE CHECKED BY: DRAWN BY: DESIGNED BY: PROJECT ENGINEER: REV ISSUED FOR DATE BY 0 1"1/2" CONTRACT NO.: HAZEN NO.: DATE: DRAWING NUMBER:HAZEN AND SAWYER 2420 S. LAKEMONT AVENUE, SUITE 325, ORLANDO, FLORIDA 32814 C. LOMBANA M. FORTIN T. BOMARITO 1 CONCEPTUAL ALIGNMENT 10/2024 MP 2 60% DESIGN 01/2025 MP 3 100% DESIGN 06/2025 MP 4 ISSUED FOR BID 08/2025 MP