Loading...
HomeMy WebLinkAboutItem 08 Approval of License Agreement Between Florida Central Railroad Company, LLC (FCEN) for the Clarke Road Force Main Relocation Project City of Ocoee ▪ 1 N. Bluford Avenue ▪ Ocoee, Florida 34761 Phone: (407) 905-3100 ▪ www.ocoee.org STAFF REPORT Meeting Date: January 6, 2026 Item #: 8 Contact Name: Department Director: Jen Bolling Contact Number: City Manager: Craig Shadrix Subject: Approval of License Agreement Between Florida Central Railroad Company, LLC (FCEN) for the Clarke Road Force Main Relocation Project. (Utilities Director Bolling) Background Summary: The 8” force main on North Clarke Road, north of A.D. Mims Road, has experienced several breaks and requires replacement to avoid future pipe breaks. The force main replacement has been split into two phases. Phase 1 was completed with the Clarke Road Widening project. Phase 2 runs approximately 550 feet north of Ocoee Vista Parkway and runs south to AD Mims Road and includes the relocation of the existing Florida Central Railroad (FCEN) crossing. Relocation of the railroad crossing removes the current point of connection from under pavement in the intersection of Wurst Road and Clarke Road into a grass area adjacent to Wurst Road. To construct any utilities under the railroad tracks, the City must first enter into a licensing agreement with FCEN. Past agreements with FCEN have required the City to pay an annual license fee that increases each year based on the Consumer Price Index (CPI). To avoid recurring yearly fees with escalation, staff is requesting approval of a one-time application fee of $1,500.00 and a one-time license fee of $24,400.00. The existing annually reoccurring licensing agreement will be terminated upon completion of the force main relocation and the the one-time license fee will provide the City with substantial savings over the lifetime of the agreement. Issue: Should the Honorable Mayor and City Commission approve the one-time license application and License Agreement between Florida Central Railroad Company, LLC (FCEN) for the Clarke Road Force Main Relocation Project? Recommendations: Staff recommends that the Honorable Mayor and City Commission approve the one-time application and License Agreement with FCEN for the Clarke Road Force Main Relocation Project at a total cost of $25,900.00. Staff also recommends that the City Manager be authorized to approve changes to this contract up to the limit of his purchasing authority. Attachments: 1. Agreement City of Ocoee ▪ 1 N. Bluford Avenue ▪ Ocoee, Florida 34761 Phone: (407) 905-3100 ▪ www.ocoee.org Financial Impacts: The City has adequate funding in the Capital Improvements Fund (G/L: 408-535-10-6302) under Job #P000339 for this agreement. Type of Item: Consent OCOE-62-205 657845.1 1 LICENSE AGREEMENT THIS LICENSE AGREEMENT is made and entered into as of this ___ day of __________, 2026 by and between FLORIDA CENTRAL RAILROAD COMPANY, LLC, a Florida corporation with an address of 3001 West Orange Avenue, Apopka, FL 32703 (“FCEN”) CITY OF OCOEE., a municipal corporation of Florida with an address of 1 North Bluford Avenue, Ocoee, FL 34761 (the “Licensee”). Preliminary Statement A. Licensee, for the economical and convenient conduct of Licensee’s business, desires to obtain from FCEN a license to use a portion of FCEN’s right of way leased to FCEN pursuant to a lease agreement between FCEN and CSX Transportation, Inc. (the “CSX Lease”), without establishing, claiming, or possessing any estate or interest therein (the “License”), for the benefit of License. B. FCEN has the right, power, and authority to enter into this License Agreement, pursuant to the CSX Lease. C. Licensee desires to construct and maintain an underground force sewer main, (the “Pipe”) within the License Area, defined below. NOW THEREFORE, in consideration of the mutual promises contained herein the parties agree as follows: 1. GRANT OF LICENSE FCEN hereby grants unto Licensee, its successors and assigns a License, with authority to enter upon, construct and maintain, pursuant to this License, the Pipe under the FCEN’s tracks and right of way near the intersection of Clarke Rd and A.D. Mims Rd. , in the vicinity of Railroad Mile Post AVB 834.98, DOT Crossing 914121Y Ocoee, Orange County, Florida (the “License Area”), described on Exhibit A, adhering to AREMA standards and the recommendations, if any, of the Intertek PSI report, which are attached hereto and incorporated herein. Original force main construction under License agreement dated 11/1/1990 incorporated here by reference shall be deemed cancelled and pipe shall be removed in its entirety or grouted in place. 2. SUBJECT TO MASTER LEASE AGREEMENT This License shall be subject to the terms and conditions of the CSX Lease, a memorandum of which is recorded in the public records. 3. STATUS OF SUBCONTRACTORS For purposes of this Agreement, all references to Licensee shall include Licensee, its contractors, subcontractors, agents, officers, employees, and others acting under its or their authority. OCOE-62-205 657845.1 2 4. USE Licensee shall use the License Area for the construction, maintenance and operation of the Pipe that are the subject of this Agreement only for the conveyance of sewer water within main, and any other purpose or use is prohibited. Notwithstanding any contrary provisions herein, Licensee agrees that this License shall not be used in any way that will inhibit the use of the License Area by FCEN, its successors or assigns. The Pipe shall be constructed, maintained and operated by Licensee in accordance with Exhibit A. 5. CONDUCT OF WORK All work connected with the construction, maintenance, repair, renewal, modification, relocation, reconstruction, or removal of the said Pipe shall be undertaken within the License Area. However, no such work shall be performed without prior written notice to, and approval of, FCEN's General Manager. Any and all work shall be performed in a manner satisfactory to the FCEN. All work shall be performed at times and in a manner which shall not disturb the reasonable operation of the business of FCEN. At the sole discretion of FCEN’s General Manager, flag protection services may be required during construction and periods of maintenance. Licensee, in accordance with Paragraph 14 below, shall be responsible for all costs and expenses of any flagging service. 6. FEE Licensee shall pay to FCEN for this License a one-time fee of Twenty-Four thousand four hundred Dollars ($24,400.00) per occupancy, (the “Fee”) plus Fifteen Hundred Dollars ($1,500.00) for application and document processing. Licensee shall pay the Fee to FCEN within thirty (30) days after presentation of an invoice. Notwithstanding any contrary provisions herein, Licensee shall not access, enter upon, or use the License Area until FCEN receives the Fee from Licensee. In the event FCEN terminates this License prior to the expiration of the Term, it will return a prorated portion of the Fee to Licensee. 7. TERM The term of this License Agreement shall run for a period of twenty (20) years from the above date. Thereafter, this Agreement shall automatically renew for successive five (5) year periods unless or until it is terminated as provided below. 8. TERMINATION Notwithstanding any contrary provisions contained herein, this Agreement may be terminated at any time by either FCEN or Licensee by giving to the other party twelve (12) months advance written notice of its intention to so terminate. In the event of termination, Licensee shall remove the Pipe and restore the License Area as nearly as possible to as good order and condition as when original entry was made thereon by OCOE-62-205 657845.1 3 said Licensee, at its sole expense, cost, and liability. Upon failure to do so, FCEN may at any time thereafter, remove the Pipe and repair the License Area at the sole expense, cost, and liability of Licensee. 9. GOVERNMENT REQUIREMENTS Installation of the Pipe pursuant to this License Agreement shall be performed in accordance with all appropriate governmental and administrative requirements for the use(s) for which such Pipe is to be maintained. 10. FCEN REGULATIONS Licensee agrees that it shall observe and obey all regulations of FCEN respecting the use of the License and the License Area. 11. NON-PERMANENT LOCATION Licensee recognizes that it may be in the best interest of FCEN to move the Pipe to other areas within FCEN's property, and therefore, Licensee agrees, at Licensee's cost and expense, to move or relocate the said Pipe at the reasonable request of FCEN. Licensee hereby agrees to effectuate and perform such move expeditiously and within reasonable constraints of time. 12. RISK, LIABILITY, INDEMNITY 12.1 To the extent permitted by applicable law and expressly limited to the amounts set forth in in §768.28, Fla. Stat. (2023), except Contractors on behalf of Licensee. Licensee shall defend, indemnify and save FCEN and its officers, shareholders, directors, affiliates, parents, employees, and agents harmless, from and against, any and all liability, loss, claim, suit, damage, charge, or expense (including reasonable attorney’s fees and experts) which any such party may suffer, sustain, incur or in any way be subjected to, on account of death of, or injury to, any person and damage to or loss of or destruction of any property, arising out of, or resulting from, or in any way connected with, the construction, presence, existence, repair, maintenance, replacement, operation, use, or removal of Licensee’s Pipe, the use of the License Area pursuant hereto or any structure in connection therewith, or restoration of the License Area to good order or condition. Other than the above limited indemnity not to exceed the amounts set forth in §768.28 Fla. Stat. (2023), nothing in this Agreement shall be construed as a waiver of Licensee's sovereign immunity. 12.2. Use of FCEN’s right of way involves certain risks of loss or damage as a result of FCEN’s operations. Licensee expressly assumes all risk of loss and damage to persons or Licensee’s property or Pipe, in, on, over or under the License Area, including loss of or any interference with use thereof, regardless of cause, including derailment, arising out of FCEN’s operations. For purposes of this section, Licensee’s property shall include the contents of the Pipe as well as property of third parties situated or placed upon FCEN’s right of way by Licensee or by such third parties at the request of or for the benefit of Licensee. OCOE-62-205 657845.1 4 12.3 Without limiting the generality of other provisions herein, Licensee also expressly assumes all risk of loss which may result from Licensee’s failure to maintain either the Pipe or the required depth and support for the Pipe. 12.4 Without limiting the generality of other provisions contained herein, Licensee assumes all responsibility for, and agrees to defend, indemnify and hold FCEN and its officers, shareholders, directors, affiliates, parents, employees, and agents harmless from (a) all claims, costs and expenses, including reasonable attorneys’ fees as a consequence of any pollution of air, water, land and/or ground water on or off the License Area, arising from, or in connection with, Licensee’s use of this License Area or resulting from the leaking, bursting, spilling, or escape of the material transmitted in or through Licensee’s Pipe; (b) any claim or liability arising under federal or state law dealing with pollution of air, water, land, and/or ground water arising from the circumstances referenced in (a) of this provision or the remedy thereof; and (c) any subsidence or failure of lateral or subjacent support of FCEN’s tracks caused by Licensee’s use of the License Area or the presence of Licensee’s facilities. 12.5 Obligations of Licensee hereunder to defend, indemnify and hold FCEN harmless shall also extend to companies or other legal entities that control or are under common control with FCEN and its/their respective officers, shareholders, directors, agents, and employees. 12.6 Nothing in this Agreement shall require Licensee to indemnify FCEN or its other subsidiaries or affiliates or hold them harmless from damages caused exclusively by FCEN’s own willful misconduct or gross negligence. 12.7. Licensee’s duty to defend, indemnify, and hold FCEN harmless shall survive the expiration and/or termination of this License Agreement. 13. NOTICES All notices on the part of Licensee to FCEN shall be given in writing to the General Manager, FLORIDA CENTRAL RAILROAD COMPANY, LLC., 3001 West Orange Avenue, Apopka, Florida 32703. All notices on the part of FCEN to Licensee shall be given in writing to the City of Ocoee, 1 N Bluford Avenue, Ocoee, Florida 34761 Attn: City Manager All notices shall be delivered in person, or via overnight courier, or email. 14. FCEN COSTS AND EXPENSES Licensee agrees to pay to FCEN all reasonable costs and expenses incurred by FCEN due to FCEN’s granting of this License or due to the use, maintenance, or existence of said License by Licensee. Such costs and expenses shall include, but are not limited to, FCEN’s cost of providing flag protection services pursuant to Paragraph 5 above. Licensee’s cost for such flag protection services shall be the then-current OCOE-62-205 657845.1 5 rate per day for the particular flag protection services that FCEN determines, in its sole discretion, are required after reviewing the needs of the work site. 15. NO WARRANTIES This License is herein granted without any warranty, express or implied, and Licensee hereby agrees that no damages shall be recoverable from FCEN because of any dispossession of Licensee or because of any failure of, defect in, cancellation of, or termination of, FCEN's property interest in the License Area. 16. ASSIGNMENT No assignment of rights or privileges hereunder by Licensee shall be valid unless the written consent of FCEN is first obtained. FCEN will consent to an assignment by the Licensee provided that the assignee assumes all obligations and duties of the Licensee to the reasonable satisfaction of FCEN, and the Licensee and the assignee execute FCEN’s usual and customary assignment and assumption agreement. 17. FUTURE PARTIES This License shall inure to the benefit of, and be binding upon, the Parties hereto and their respective, heirs, legal representatives, successors, and assigns. 18. REMEDIES The remedies under this Agreement are cumulative and shall not exclude any other remedies to which any party may be lawfully entitled. The failure or delay of any party to insist upon the strict or timely performance of a covenant hereunder or any obligation hereunder, shall not be a waiver of such party's right to demand strict compliance therewith in the future. 19. CAPTIONS All titles or captions are inserted for convenience only and they in no way shall be construed to define, limit, or describe the scope of this Agreement or any provision thereof. 20. SEVERABILITY If any clause or provision of this Agreement shall be deemed to be invalid or unenforceable under present or future laws, then, in that event it is the intention of the Parties that the remainder of this Agreement shall not be affected thereby. 21. CHOICE OF LAW This instrument is being delivered and is intended to be performed in the state of Florida and shall be construed and enforced in accordance with the laws of that state. Any aggrieved party may proceed to enforce its rights in the appropriate action at law or in equity. Venue for all suits arising out of this instrument shall lie exclusively in the Courts of Orange County, Florida. By execution or adoption of this agreement, each party hereby submits itself to the in personam jurisdiction of the Courts of Orange County, Florida. OCOE-62-205 657845.1 6 22. INSURANCE Licensee and its Contractors shall maintain insurance in the following amounts: (a) General liability insurance in the amount of Two Million dollars ($2,000,000); (b) Contractual liability in the amount of Two Million dollars ($2,000,000); (c) Worker's compensation, statutory limits or greater; (d) Automobile liability, One Million dollars ($1,000,000); and (e) Railroad Protective Liability with bodily injury protection of Two Million dollars ($2,000,000) and property damage of Two Million dollars ($2,000,000). All such insurance shall name FCEN as an additional insured. The original of the railroad protective liability policy shall be provided to FCEN and certificates of insurance evidencing Licensee’s compliance with subparagraphs (a), (b), (c), (d) and (e) above shall be forwarded to FCEN prior to any work commencing on or within the License Area. Notwithstanding anything to the contrary, the insurance required under subparagraph (e) shall only be required during installation of the Pipe and whenever the Pipe will be reconstructed, updated, maintained, or otherwise improved. 23. MODIFICATION All modifications or waivers to this License Agreement must be in writing and executed by both parties. 24. MERGER This Agreement represents the final, complete, and exclusive understanding of the Parties of the subject matter hereto. 25. LICENSEE’S AUTHORITY TO EXECUTE THIS AGREEMENT Licensee represents and warrants that it has taken all necessary actions required in order to enter into this License Agreement and cause it to be fully enforceable against Licensee, and that its agent below is authorized to execute this License Agreement. [END OF AGREEMENT EXCEPT FOR SIGNATURE PAGE AND EXHIBIT] OCOE-62-205 657845.1 7 IN WITNESS WHEREOF, the parties have executed this Agreement as a sealed instrument on the day, month and year first written above. Signed and delivered in the presence of: FLORIDA CENTRAL RAILROAD COMPANY, LLC. By:_______________________________ By: ________________________________ CITY OF OCOEE SIGNATURE PAGE (Florida Central Railroad Company - Lease Agreement - North Clark Rd Railroad Crossing) CITY: CITY OF OCOEE, FLORIDA By: Rusty Johnson, Mayor ATTEST: Melanie Sibbitt, City Clerk (SEAL) FOR USE AND RELIANCE ONLY BY THE CITY OF OCOEE, FLORIDA; APPROVED AS TO FORM AND LEGALITY this ____ day of _________________, 20____. FISHBACK DOMINICK By: __________________________ Richard Geller, City Attorney APPROVED BY THE CITY OF OCOEE COMMISSION AT A MEETING HELD ON ______________, 2025, UNDER AGENA ITEM NO. ____ 8 657845.1 OCOE-62-205 OCOE-62-205 657845.1 9 EXHIBIT A LICENSEE’S 2025 APPLICATION FOR PIPE CROSSING AND INTERTEK PSI GEOGECHNICAL REPORT (14 pages below) Jo b N o . - C I T Y O F O C O E E - P r o j e c t N a m e COMMISSIONER DISTRICT 1:SCOTT R. KENNEDY MAYOR: COMMISSIONER DISTRICT 2: COMMISSIONER DISTRICT 3: CITY OFFICIALS: RUSTY JOHNSON ROSEMARY WILSEN CITY MANAGER: GEORGE OLIVER III RICHARD FIRSTNER COMMISSIONER DISTRICT 4: CRAIG SHADRIX INDEX OF SHEETS: C-1 COVER SHEET C-2 GENERAL NOTES C-3 PLAN AND PROFILEC-4 PLAN C-6 PROFILE C-7 PLAN AND PROFILE C-5 C-8 City of Ocoee Clarke Road Force Main Relocation OCTOBER 2025 ASSISTANT CITY MANAGER:MICHAEL RUMER UTILITIES DIRECTOR:JENNIFER BOLLING, P.E. VICINITY MAP N.T.S. N PROJECT LOCATION 1117 East Robinson Street Orlando, FL 32801 Ph: 407.425.0452 www.cphcorp.com Building BetterCommunities Together Plans Prepared By: State of Florida Licenses: Engineer No. 3215 Surveyor No. LB7143 Architect. No. AA26000926 Landscape No. LC000298 J:\O6025\Civil\DWG\_Current_Plan_Set\O6025 Cover .dwg August 11, 2025 10 0 % S U B M I T T A L Sheet No.C-1ROBERTO MARCOS GONZALEZ, P.E. P.E. LIC. # 56875 C-9 DETAILS A D MIM S R D . C L A R K E R D . VISTAOCOEE PK W Y EXISTING LIFT STATION No. 32 C-10 STANDARD DETAILS RAILROAD CROSSING OWNER: CITY OF OCOEE 1 N. BLUFORD AVE. OCOEE, FL 34761 PH. 407.905.3100 CONTACT: CITY OF OCOEE UTILITIES DEPARTMENT 1800 A. D. MIMS RD. OCOEE, FL 34761 PH. 407.905.3159 KEY SHEET C-11 STANDARD DETAILS Drawing name: J:\O6025\Civil\DWG\_Current_Plan_Set\O6025 General Notes.dwg Oct 15, 2025 - 4:51pm zaadad Job No. Date: Checked by: Designed by: Drawn by: Sheet No.No.DateNo.Date Revision www.cphcorp.com C 2025 Revision 1 2 3 4 5 6 7 8 1117 East Robinson Street Orlando, FL 32801 Ph: 407.425.0452 Plans Prepared By: State of Florida Licenses: Engineer No. 3215 Surveyor No. LB7143 Architect. No. AA26000926 Landscape No. LC000298 Building BetterCommunities Together ROBERTO MARCOS GONZALEZ, P.E. P.E. LIC. # 56875 City of Ocoee Clarke Road Force Main Relocation Ocoee, Florida O6025 3/2025 RMG MEP GCM 10 0 % S U B M I T T A L GENERAL NOTES C-2 GENERAL PROVISIONS 1.THE CONTRACTOR SHALL OBTAIN FROM THE OWNER COPIES OF ALL AVAILABLE REGULATORY AGENCY PERMITS AND LOCAL AGENCY PERMITS. 2.ALL CONSTRUCTION PROJECTS 1 OR MORE ACRES IN SIZE THAT DISCHARGE TO OFFSITE AREAS ARE REQUIRED TO COMPLY WITH THE REQUIREMENTS OF THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) GENERAL PERMIT FOR STORMWATER DISCHARGE FROM SMALL AND LARGE CONSTRUCTION ACTIVITIES. IN ORDER TO MEET NPDES REQUIREMENTS, THE CONTRACTOR IS RESPONSIBLE FOR PREPARING A STORMWATER POLLUTION PREVENTION PLAN (SWPPP), IMPLEMENTING, INSPECTING, MAINTAINING, AND REPORTING ON ALL ELEMENTS OF THE SWPPP, COMPLETING AND SUBMITTING THE REQUIRED NOTICE OF INTENT (NOI) AND NOTICE OF TERMINATION (NOT) FORMS AS THE OPERATOR, AND PAYING ALL ASSOCIATED FEES. FOR PROJECTS LESS THAN 1 ACRE IN SIZE THAT ARE NOT REQUIRED TO COMPLY WITH THE NPDES GENERAL PERMIT, THE CONTRACTOR IS STILL RESPONSIBLE FOR IMPLEMENTING AND MAINTAINING EROSION AND SEDIMENT CONTROL MEASURES PRIOR TO AND DURING CONSTRUCTION IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS. 3.UNLESS OTHERWISE NOTED ON THE PLANS, THE CONTRACTOR SHALL USE THE GEOMETRY PROVIDED ON THE CONSTRUCTION PLANS. BENCHMARK INFORMATION SHALL BE PROVIDED TO THE CONTRACTOR BY THE OWNER OR OWNER'S SURVEYOR. ANY DISCREPANCIES BETWEEN FIELD MEASUREMENTS AND CONSTRUCTION PLAN INFORMATION SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER IMMEDIATELY. 4.CONTRACTOR SHALL PROVIDE A PRECONSTRUCTION VIDEO DOCUMENTING THE EXISTING CONDITIONS FROM RIGHT-OF-WAY TO RIGHT-OF-WAY ALONG PROJECT LIMITS. CONTRACTOR SHALL HAVE PROJECT SURVEYED AND STATION NUMBERS STAKES AND/OR PINS IN ASPHALT PRIOR TO PROVIDING A PRECONSTRUCTION VIDEO. 5.THE CONTRACTOR SHALL SUBMIT ELECTRONIC COPIES OF SHOP DRAWINGS TO THE ENGINEER AND CITY OF OCOEE UTILITIES ENGINEERING FOR APPROVAL PRIOR TO ORDERING THE MATERIALS REQUIRED FOR CONSTRUCTION. PRIOR TO SUBMISSION, THE CONTRACTOR SHALL THOROUGHLY CHECK SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES FOR COMPLETENESS AND FOR COMPLIANCE WITH THE CONSTRUCTION PLANS AND SHALL VERIFY ALL DIMENSIONS AND FIELD CONDITIONS AND SHALL COORDINATE THE SHOP DRAWINGS WITH THE REQUIREMENTS FOR OTHER RELATED WORK. THE CONTRACTOR'S RESPONSIBILITY FOR ERRORS AND OMISSIONS IN SUBMITTALS IS NOT RELIEVED BY THE ENGINEER'S AND CITY'S REVIEW OF SUBMITTALS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND CITY OF OCOEE UTILITIES ENGINEERING DEPARTMENT, IN WRITING AT THE TIME OF SUBMISSION, OF DEVIATIONS IN SUBMITTALS FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. 6.PROTECT BENCHMARKS, PROPERTY CORNERS, AND OTHER SURVEY MONUMENTS FROM DAMAGE OR DISPLACEMENT. IF MARKER NEEDS TO BE REMOVED IT SHALL BE REFERENCED BY LICENSED LAND SURVEYOR AND REPLACED, AS NECESSARY, BY SAME. 7.THE CONTRACTOR SHALL COORDINATE QUALITY CONTROL TESTING. AS A MINIMUM, TESTING SHALL INCLUDE A) PIPING AND STRUCTURAL EXCAVATION, BEDDING AND BACKFILL MATERIALS AND DENSITY TESTS; B) DETERMINATION OF COMPACTIVE EFFORT NEEDED FOR COMPLIANCE WITH THE DENSITY REQUIREMENTS; C) PORTLAND CEMENT CONCRETE AND ASPHALT PAVING QUALITY CONTROL TESTING INCLUDING DESIGN MIX REVIEW, MATERIALS, FIELD SLUMP AND AIR CONTENT, AND FIELD AND LAB CURED STRENGTH SAMPLES AND TESTING. 8.IN ADDITION TO QUALITY CONTROL TESTING, THE CONTRACTOR SHALL BE RESPONSIBLE FOR REQUIRED TESTING OR APPROVALS FOR ANY WORK (OR ANY PART THEREOF) IF LAWS OR REGULATIONS OF ANY PUBLIC BODY HAVING JURISDICTION SPECIFICALLY REQUIRE TESTING, INSPECTIONS OR APPROVAL. THE CONTRACTOR SHALL PAY ALL COSTS IN CONNECTION THEREWITH AND SHALL FURNISH THE OWNER AND ENGINEER THE REQUIRED CERTIFICATES OF INSPECTION, TESTING OR APPROVAL. 9.TESTING RESULTS SHALL BE PROVIDED TO THE OWNER/OPERATOR AND THE ENGINEER. ALL TEST RESULTS SHALL BE PROVIDED (PASSING AND FAILING) ON A REGULAR AND IMMEDIATE BASIS. ALL TESTING SHALL BE SCHEDULED AND PERFORMED IN THE PRESENCE OF A CITY INSPECTOR. ANY TESTING NOT WITNESSED BY A CITY INSPECTOR SHALL BE RETESTED. 10.THE ENTIRE PROJECT SITE SHALL BE THOROUGHLY CLEANED AT THE COMPLETION OF THE WORK. CLEAN ALL INSTALLED PIPELINES, STRUCTURES, SIDEWALKS, PAVED AREAS, ACCUMULATED SILT IN PONDS, PLUS ALL ADJACENT AREAS AFFECTED BY CONSTRUCTION, AS DIRECTED BY THE OWNER OR JURISDICTIONAL AGENCY. EQUIPMENT TO CLEAN THESE SURFACES SHALL BE SUBJECT TO APPROVAL BY THE OWNER. 11.CHAPTER 556, FLORIDA STATUTES, REQUIRES EXCAVATORS TO NOTIFY SUNSHINE STATE ONE CALL OF FLORIDA (SSOCOF) BEFORE BEGINNING ANY EXCAVATION IN THE STATE OF FLORIDA UNLESS A SPECIFIC EXEMPTION LISTED IN F.S. 556.108 APPLIES. AN EXCAVATOR MUST NOTIFY SSOCOF TWO FULL BUSINESS DAYS BEFORE EXCAVATING. EXCAVATORS MAY CALL 1-800-432-4770 DURING BUSINESS HOURS OR USE THE INTERNET TO PROVIDE NOTIFICATION INFORMATION. 12. ALL SODDING, SIDEWALK, AND ROADWAY RESTORATIONS SHALL BE COMPLETED 10 WORKING DAYS PRIOR TO FINAL WALKTHROUGH INSPECTION. 13. CONTRACTOR SHALL KEEP A COPY OF THE STAMPED APPROVED CONSTRUCTION PLANS ONSITE AT ALL TIME. UTILITY GENERAL NOTES 1.THE UTILITY DATA SHOWN ON THESE PLANS WAS LOCATED BY THE RESPECTIVE UTILITY, OR IS BASED ON UTILITY DRAWINGS, MAPS, OR FIELD RECONNAISSANCE. 2.THE LOCATIONS OF ALL EXISTING UTILITIES SHOWN ON THE PLANS HAVE BEEN DETERMINED FROM THE BEST INFORMATION AVAILABLE AND ARE GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THEIR ACCURACY. PRIOR TO THE START OF ANY CONSTRUCTION ACTIVITY, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE VARIOUS UTILITIES AND TO MAKE THE NECESSARY ARRANGEMENTS FOR ANY RELOCATIONS OF THESE UTILITIES WITH THE OWNER OF THE UTILITY. THE CONTRACTOR SHALL EXERCISE CAUTION WHEN CROSSING AN UNDERGROUND UTILITY, WHETHER SHOWN ON THE PLANS OR LOCATED BY THE UTILITY COMPANY. ANY UTILITIES, WHETHER SHOWN ON THESE PLANS OR NOT, THAT INTERFERE WITH THE PROPOSED CONSTRUCTION SHALL BE CLOSELY COORDINATED WITH THE ENGINEER AND THE RESPECTIVE UTILITY COMPANY FOR RELOCATION OR PROPER INSTRUCTION. 3.A SINGLE POINT UTILITY IDENTIFICATION SERVICE HAS BEEN SET UP FOR EXISTING UTILITIES. THE CONTRACTOR IS TO CONTACT THE SUNSHINE STATE ONE CALL CENTER BY DIALING “811” AT LEAST TWO (2) AND NO MORE THAN FIVE (5) WORKING DAYS PRIOR TO THE SPECIFIC CONSTRUCTION ACTIVITY FOR FIELD LOCATION. NOTE THAT NOT ALL UTILITIES PARTICIPATE IN THIS PROGRAM. THE CONTRACTOR SHOULD CONTACT ALL NON-PARTICIPATING UTILITIES SEPARATELY FOR FIELD LOCATION OF THEIR FACILITIES AT LEAST TWO (2) WORKING DAYS PRIOR TO CONSTRUCTION. PER FLORIDA STATUTE 553.851, THE CONTRACTOR OR EXCAVATOR IS REQUIRED TO NOTIFY THE GAS COMPANY TWO (2) WORKING DAYS PRIOR TO STARTING EXCAVATION. 4.THE FOLLOWING UTILITIES MAY HAVE FACILITIES IN THE VICINITY OF THE CONSTRUCTION AREA: CITY OF OCOEE DUKE ENERGY AMERICAN TRAFFIC SOLUTIONS CHARTER LAKE APOPKA NATURAL GAS CENTURYLINK FCEN RAILROAD 5.THE CONTRACTOR SHALL KEEP LOCATE TICKETS UP TO DATE AT ALL TIMES. 6.THE CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION WITH EACH UTILITY AND ALL COSTS ASSOCIATED WITH THE PROTECTION OF EXISTING FACILITIES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE NECESSARY RELOCATIONS OR OTHER CONSTRUCTION RELATED MATTERS WITH EACH UTILITY. 7.IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN IN SERVICE ALL EXISTING PIPING ENCOUNTERED DURING CONSTRUCTION UNLESS OTHERWISE INDICATED IN THE DRAWINGS. ANY PIPING WHICH CAN BE REMOVED DURING CONSTRUCTION WITHOUT UNDUE INTERRUPTION OF SERVICE MAY BE REMOVED AND REPLACED BY THE CONTRACTOR WITH THE PERMISSION OF THE OWNER AND THE ENGINEER. 8.TYPICAL DETAILS AS SHOWN ARE TO ILLUSTRATE THE ENGINEER'S INTENT AND ARE NOT PRESENTED AS A SOLUTION TO ALL CONSTRUCTION PROBLEMS ENCOUNTERED IN THE FIELD. THE CONTRACTOR MAY ALTER THE METHOD OF CONSTRUCTION TO SUIT FIELD CONDITIONS, PROVIDING HE SUBMITS A PROPOSAL FOR AN ALTERNATE METHOD TO THE ENGINEER FOR APPROVAL AND USES MATERIALS AS DESIGNATED IN THE SPECIFICATIONS. 9.FOR EACH RESPECTIVE PIPELINE CONSTRUCTION REQUIRED, THE CONTRACTOR SHALL FIELD VERIFY THE LOCATION, DEPTH, AND ALIGNMENT OF ALL EXISTING PIPES, CABLES, ETC. TO BE CROSSED OR CONNECTED TO. IF THE CONTRACTOR DEEMS NECESSARY (A) A CHANGE IN ALIGNMENT OR DEPTH, OR THE NEED FOR ADDITIONAL FITTINGS, BENDS, OR COUPLINGS, WHICH REPRESENT A DEPARTURE FROM THE CONTRACT DRAWING, OR (B) A NEED FOR RELOCATION OF EXISTING UTILITIES, THEN DETAILS OF SUCH DEPARTURES, RELOCATIONS, OR ADDITIONAL FITTINGS, INCLUDING CHANGES IN RELATED PORTIONS OF THE PROJECT AND THE REASONS THEREFORE, SHALL BE SUBMITTED WITH SHOP DRAWINGS. APPROVED DEPARTURES FOR THE CONTRACTOR'S CONVENIENCE SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER. 10.THE CONTRACTOR SHALL PROVIDE AT HIS OWN EXPENSE ALL NECESSARY TEST PUMPING EQUIPMENT, WATER, WATER METERS, PRESSURE GAUGES, AND OTHER EQUIPMENT, MATERIAL AND FACILITIES REQUIRED FOR ALL HYDROSTATIC, LEAKAGE, AND PRESSURE TESTING. THE CONTRACTOR SHALL CONTACT THE ENGINEER AND THE OWNER IN WRITTEN FORM, FORTY-EIGHT (48) HOURS IN ADVANCE OF PROPOSED TESTING. THE CONTRACTOR SHALL COMPLETE PRELIMINARY TESTING PRIOR TO SCHEDULING THE OFFICIAL PRESSURE TEST. THE CONTRACTOR SHALL NOTIFY THE CITY UTILITIES INSPECTOR IN WRITING 48 HOURS IN ADVANCE OF PROPOSED TESTING. 11.THE CONTRACTOR SHALL REFER TO THE CITY OF OCOEE ENGINEERING STANDARDS, APPROVED MATERIALS LIST, AND DETAILS. THE MOST STRINGENT STANDARDS BETWEEN THE CITY OF OCOEE AND FDEP SHALL BE FOLLOWED FOR ALL PUBLIC UTILITIES. 12.ALL IMPROVEMENTS TO BE DEDICATED AND/OR MAINTAINED BY THE CITY SHALL BE IN CONFORMANCE WITH THE CURRENT CITY OF OCOEE ENGINEERING STANDARDS MANUAL, MATERIALS LIST, AND DETAILS. ANY DEVIATION FROM THE CITY OF OCOEE ENGINEERING STANDARDS MUST BE REQUESTED AND APPROVED IN WRITING PRIOR TO CONSTRUCTION. FINAL PLAN APPROVAL DOES NOT PROVIDE EXEMPTION FROM THESE REQUIREMENTS. 13.CONTRACTOR SHALL DRILL AIR HOLES TO AVOID FRACKING DURING THE DIRECTIONAL DRILLING OPERATIONS. AS-BUILT DRAWING REQUIREMENTS 1.AS-BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER THREE WEEKS PRIOR TO FINAL INSPECTION. ALL AS-BUILT DATA SHALL BE PROVIDED BY A FLORIDA LICENSED SURVEYOR, SIGNED, SEALED AND DATED BY THE RESPONSIBLE PARTY. 2.AS BUILT NEED TO BE SUBMITTED TO THE CITY SIGNED AND SEALED IN ACCORDANCE WITH SECTION 3.01.05 OF THE ENGINEERING STANDARD MANUAL IN THE FOLLOWING FORMATS: ·ONE PDF COPY. ·ONE CAD COPY DRAWN IN STATE PLANE COORDINATES. 3.AS-BUILTS SHALL INCLUDE HDPE JOINT SEAMS SITE PREPARATION 1.UNLESS OTHERWISE DIRECTED BY THE OWNER OR ENGINEER, THE CONTRACTOR IS EXPECTED TO CONTAIN ALL CONSTRUCTION ACTIVITIES AS INDICATED ON THE DRAWINGS. ANY REPAIR OR RECONSTRUCTION OF DAMAGED AREAS SHALL BE REPAIRED BY THE CONTRACTOR ON AN IMMEDIATE BASIS. ALL COSTS FOR REPAIRS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND NO EXTRA COMPENSATION SHALL BE PROVIDED. 2.STAKE OUT THE CONSTRUCTION, ESTABLISH LINES AND LEVELS, TEMPORARY BENCH MARKS, BATTER BOARDS, CENTERLINES, BASELINES, AND REFERENCE POINTS FOR THE WORK, AND VERIFY ALL DIMENSIONS RELATING TO INTERCONNECTION WITH EXISTING FEATURES. REPORT ANY INCONSISTENCIES IN THE PROPOSED GRADES, LINES AND LEVELS, DIMENSIONS AND LOCATIONS TO THE ENGINEER BEFORE COMMENCING WORK. 3.PROTECT ALL TREES AND SHRUBS, PARTICULARLY THOSE TREES AND SHRUBS LOCATED ADJACENT TO WORK AREAS. 4.TREES TO REMAIN IN THE CONSTRUCTION AREA SHALL BE BOXED, FENCED OR OTHERWISE PROTECTED IN ACCORDANCE WITH DETAILS ON THE DRAWINGS. DO NOT PERMIT HEAVY EQUIPMENT OR STOCKPILES WITHIN BRANCH SPREAD 5.AREAS TO RECEIVE CLEARING AND GRUBBING SHALL INCLUDE ALL AREAS TO BE OCCUPIED BY THE PROPOSED IMPROVEMENTS, AREAS FOR FILL AND SITE GRADING, AND BORROW SITES. REMOVE TREES OUTSIDE OF THESE AREAS ONLY AS INDICATED ON THE DRAWINGS OR AS APPROVED IN WRITING BY THE ENGINEER. 6.CLEARING SHALL CONSIST OF REMOVING TREES AND BRUSH AND DISPOSAL OF OTHER MATERIALS THAT ENCROACH UPON OR OTHERWISE OBSTRUCT THE WORK. 7.EXERCISE EXTREME CARE DURING THE CLEARING AND GRUBBING OPERATIONS. DO NOT DAMAGE EXISTING STRUCTURES, PIPES OR UTILITIES. 8.GRUBBING SHALL CONSIST OF REMOVING AND DISPOSING OF STUMPS, ROOTS LARGER THAN 2" IN DIAMETER, AND MATTED ROOTS. REMOVE TO A DEPTH OF NOT LESS THAN 18" BELOW THE ORIGINAL SURFACE LEVEL OF THE GROUND. 9.ALL COMBUSTIBLE DEBRIS AND REFUSE FROM SITE PREPARATION OPERATIONS SHALL BE REMOVED TO LEGAL OFFSITE DISPOSAL AREAS. EXCAVATION, TRENCHING, AND FILL 1.THE CONTRACTOR SHALL RECOGNIZE AND ABIDE BY ALL OSHA EXCAVATION SAFETY STANDARDS, INCLUDING THE FLORIDA TRENCH SAFETY ACT (FS 553.60-553.64). ANY MATERIAL, CONSTRUCTION METHODS, OR MATERIAL COST TO COMPLY WITH THESE LAWS SHALL BE INCIDENTAL TO THE CONTRACT. 2.ROUGH EXCAVATE AND GRADE ANY PROPOSED STORMWATER PONDS AT THE START OF SITE GRADING ACTIVITIES. DIRECT SITE RUNOFF TO THE PONDS TO MINIMIZE RUNOFF TO OFFSITE AREAS. 3.POND CONSTRUCTION SHALL RESULT IN THE FINISHED POND HAVING SIDE SLOPES AND DIMENSIONS THAT ARE IN ACCORDANCE WITH THE CONSTRUCTION DRAWINGS. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO ENSURE THAT THESE REQUIREMENTS HAVE BEEN MET. IF THE CONSTRUCTED SIDE SLOPES ARE STEEPER THAN THE REQUIRED SIDE SLOPES, OR THE POND VOLUME IS NOT WITHIN THREE (3) PERCENT OF THE DESIGN VOLUME, THE CONTRACTOR MAY BE REQUIRED TO MAKE CORRECTIONS TO THE POND AT NO ADDITIONAL COST TO THE OWNER. 4.FIELD DENSITY TESTING FREQUENCIES: A) ONE TEST FOR EACH 10,000 SQUARE FEET OR FRACTION THEREOF PER LIFT OF GENERAL BACKFILLING, MINIMUM 2 TESTS EACH LAYER; B) ONE TEST FOR EACH 100 SQUARE FEET OR FRACTION THEREOF OF BACKFILL AROUND AND UNDER STRUCTURES; C) ONE TEST FOR EACH 300 LINEAL FEET OR FRACTION THEREOF PER LIFT OF GENERAL BACKFILLING IN THE PIPELINE TRENCH; D) ONE TEST PER LIFT PER EACH CHANGE IN TYPE OF FILL; E) ONE TEST PER 1000 SQUARE FEET OF PAVEMENT SUBGRADE, MINIMUM OF 2 TESTS. 5.IT IS INTENDED THAT PREVIOUSLY EXCAVATED MATERIALS CONFORMING TO THE FOLLOWING REQUIREMENTS BE UTILIZED WHEREVER POSSIBLE. A.ACCEPTABLE MATERIALS: AASHTO M145 CLASSIFICATION A-1, A-3, A-2-4, A-2-6; ASTM D2487 CLASSIFICATION GW, GP, GM, SM, SW, SP; UNLESS OTHERWISE DISAPPROVED WITHIN THE SOIL AND SUBSURFACE INVESTIGATION REPORTS. NO MORE THAN 12% OF ACCEPTABLE MATERIALS SHALL PASS THE NUMBER 200 SIEVE. B.UNACCEPTABLE MATERIALS: AASHTO M145 CLASSIFICATION A-2-5, A-2-7, A-4, A-5, A-6, A-7, A-8; ASTM D2487 CLASSIFICATION GC, SC, ML, MH, CL, CH, OL, OH, PT; UNLESS OTHERWISE APPROVED WITHIN THE SOIL AND SUBSURFACE INVESTIGATION REPORTS. 6.PROVIDE BARRIERS, WARNING LIGHTS AND OTHER PROTECTIVE DEVICES AT ALL EXCAVATIONS. 7.SIDEWALKS, ROADS, STREETS, AND PAVEMENTS SHALL NOT BE BLOCKED OR OBSTRUCTED BY EXCAVATED MATERIALS, EXCEPT AS AUTHORIZED BY THE ENGINEER, IN WHICH CASE ADEQUATE TEMPORARY PROVISIONS MUST BE MADE FOR SATISFACTORY TEMPORARY PASSAGE OF PEDESTRIANS, AND VEHICLES. MINIMIZE INCONVENIENCE TO PUBLIC TRAVEL OR TO TENANTS OCCUPYING ADJOINING PROPERTY. 8.FURNISH, INSTALL, AND MAINTAIN, WITHOUT ADDITIONAL COMPENSATION, SHEETING, BRACING, AND SHORING SUPPORT REQUIRED TO KEEP EXCAVATIONS WITHIN THE PROPERTY OR EASEMENTS PROVIDED, TO SUPPORT THE SIDES OF THE EXCAVATION, AND TO PREVENT ANY MOVEMENT WHICH MAY DAMAGE ADJACENT PAVEMENTS OR STRUCTURES, DAMAGE OR DELAY THE WORK, OR ENDANGER LIFE AND HEALTH. VOIDS OUTSIDE THE SUPPORTS SHALL BE IMMEDIATELY FILLED AND COMPACTED. 9.SHEETING, SHORING, AND BRACING USED FOR THE SUPPORT OF EXCAVATION NEAR OTHERS STRUCTURES, CURBING, ROADWAY, AND EXCAVATIONS OVER 20 FEET DEEP SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED BY THE STATE OF FLORIDA. 10.ALL EXCAVATIONS SHALL BE MADE BY OPEN CUT UNLESS OTHERWISE INDICATED. SLOPE SIDES OF TRENCHES IN ACCORDANCE WITH OSHA REQUIREMENTS AND THE RECOMMENDATIONS CONTAINED WITHIN THE PROJECT GEOTECHNICAL REPORT. 11.EXCAVATE TRENCHES TO DEPTH INDICATED OR REQUIRED FOR INDICATED FLOW LINES AND INVERT ELEVATIONS. OVER EXCAVATE TRENCHES A MINIMUM OF 2 FEET WHERE EXCAVATIONS OCCUR WITHIN UNSUITABLE SOILS, AND REPLACE OVER EXCAVATED MATERIAL WITH SUITABLE SOILS. 12.EXCEPT AS OTHERWISE INDICATED, EXCAVATE FOR PRESSURE PIPING SO TOP OF PIPING IS MINIMUM 3 FEET BELOW FINISHED GRADE. 13.TRENCH BOTTOMS AND THE BOTTOMS OF ALL STRUCTURES SHALL BE KEPT DRY, COMPACTED, AND STABLE TO A DEPTH TWO FEET BELOW THE BOTTOM OF THE TRENCH OR STRUCTURE. 14.ALL BEDDING, FILL, AND BACKFILL MATERIAL SHALL BE SUITABLE SOILS OR FLOWABLE FILL. WHERE TRENCH OR EXCAVATION IS WITHIN THE INFLUENCE AREA OF ROADWAYS, STRUCTURES, FOUNDATIONS, OR SLABS, PLACE BACKFILL IN LAYERS OF 8 INCH LOOSE DEPTH. IN ALL OTHER AREAS, PLACE FILL AND BACKFILL IN LAYERS OF 12 INCH LOOSE DEPTH. 15.MINIMUM DENSITY REQUIREMENT (ASTM D1557 OR AASHTO T180): BACKFILL AND FILL UNDER AND WITHIN THE INFLUENCE AREA OF ROADWAYS, STRUCTURES, SLABS, FOUNDATIONS = 98 PERCENT; BACKFILL AND FILL PLACED WITHIN PUBLIC ROAD RIGHT-OF-WAY AND UTILITY EASEMENTS = 95 PERCENT; BACKFILL AND FILL PLACED WITHIN POND AND ROAD EMBANKMENT = 95 PERCENT; BACKFILL AND FILL PLACED IN ALL OTHER AREAS = 90 PERCENT. UTILITY SEPARATION REQUIREMENTS 1.THE MOST STRINGENT STANDARDS BETWEEN THE CITY OF OCOEE AND FDEP STANDARDS SHALL BE FOLLOWED FOR ALL PUBLIC UTILITIES. 2.THE HORIZONTAL SEPARATION BETWEEN WATER MAINS AND SANITARY SEWER, STORM SEWER, WASTEWATER FORCE MAINS, STORMWATER FORCE MAINS, RECLAIMED WATER MAINS AND ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS SHALL BE IN ACCORDANCE WITH THE FOLLOWING: A. THE OUTSIDE OF WATER MAINS SHALL BE A MINIMUM OF THREE FEET FROM THE OUTSIDE OF ANY EXISTING OR PROPOSED STORM SEWER, STORMWATER FORCE MAIN, VACUUM TYPE SANITARY SEWER AND RECLAIMED WATER MAIN. B. THE OUTSIDE OF WATER MAINS SHALL BE A MINIMUM OF SIX FEET FROM THE OUTSIDE OF ANY EXISTING OR PROPOSED GRAVITY SANITARY SEWER AND WASTEWATER FORCE MAIN. THE MINIMUM HORIZONTAL SEPARATION DISTANCE BETWEEN THE OUTSIDE OF WATER MAINS AND THE OUTSIDE OF GRAVITY SANITARY SEWERS CAN BE REDUCED TO THREE FEET WHERE THE BOTTOM OF THE WATER MAIN IS AT LEAST SIX INCHES ABOVE THE TOP OF THE SEWER. C. THE OUTSIDE OF WATER MAINS SHALL BE A MINIMUM OF TEN FEET FROM ALL PARTS OF ANY EXISTING OR PROPOSED ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SUCH AS SEPTIC TANKS, DRAINFIELDS, AND GREASE TRAPS. ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS DO NOT INCLUDE PACKAGE SEWAGE TREATMENT FACILITIES AND PUBLIC WASTEWATER TREATMENT FACILITIES. 3.THE VERTICAL SEPARATION BETWEEN WATER MAINS AND SANITARY AND STORM SEWER, WASTEWATER OR STORMWATER FORCE MAINS, AND RECLAIMED WATER MAINS SHALL BE IN ACCORDANCE WITH THE FOLLOWING: A. WHEREVER POSSIBLE, WATER MAINS SHALL CROSS OVER EXISTING OR PROPOSED GRAVITY SANITARY SEWER, VACUUM TYPE SANITARY SEWER, AND STORM SEWER, SO THE OUTSIDE OF THE WATER MAIN IS AT LEAST EIGHTEEN INCHES ABOVE THE OUTSIDE OF THE SEWER. WHERE IT IS NOT POSSIBLE FOR THE WATER MAIN TO CROSS OVER EXISTING OR PROPOSED GRAVITY SANITARY SEWER, VACUUM TYPE SANITARY SEWER, AND STORM SEWER, THEN THE WATER MAIN CAN CROSS UNDER THESE TYPES OF PIPELINE SYSTEMS PROVIDED THE OUTSIDE OF THE WATER MAIN IS AT LEAST 12 INCHES BELOW THE OUTSIDE OF THE PIPELINE. AT THE CROSSING, THE PROPOSED PIPE JOINTS SHALL BE ARRANGED SO THAT ALL WATER MAIN JOINTS ARE AT LEAST THREE FEET FROM VACUUM TYPE SANITARY SEWER OR STORM SEWER JOINTS, AND AT LEAST SIX FEET FROM GRAVITY SANITARY SEWER JOINTS. B. WHEREVER POSSIBLE, WATER MAINS SHALL CROSS OVER EXISTING OR PROPOSED RECLAIMED WATER MAINS, WASTEWATER FORCE MAINS AND STORMWATER FORCE MAINS. WHETHER THE WATER MAIN CROSSES OVER OR UNDER THESE TYPES OF PIPELINE SYSTEMS, THE OUTSIDE OF THE WATER MAIN SHALL BE AT LEAST 18 INCHES FROM THE OUTSIDE OF THE EXISTING OR PROPOSED RECLAIMED WATER MAIN, WASTEWATER FORCE MAIN AND STORMWATER FORCE MAIN. AT THE CROSSING, THE PROPOSED PIPE JOINTS SHALL BE ARRANGED SO THAT ALL WATER MAIN JOINTS ARE AT LEAST THREE FEET FROM RECLAIMED WATER MAIN JOINTS AND STORMWATER FORCE MAIN JOINTS, AND AT LEAST SIX FEET FROM THE JOINTS OF WASTEWATER FORCE MAINS. 4. WHERE SEPARATION IN ACCORDANCE WITH CITY OF OCOEE DETAIL UT013 CAN NOT BE MET, A LESSER SEPARATION IN ACCORDANCE WITH 62.555.314 MAY BE ALLOWED. EOR SHALL REQUEST AN EXEMPTION TO THE CITY'S SEPARATION REQUIREMENTS IN WRITING. EROSION AND SEDIMENT CONTROLS 1.AN EROSION CONTROL PLAN SHALL BE PREPARED BY THE CONTRACTOR AND SUBMITTED TO THE ENGINEER FORAPPROVAL PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL EXECUTE ALL MEASURES NECESSARY TO LIMIT THE TRANSPORT OF SEDIMENTS OUTSIDE THE LIMITS OF THE PROJECT TO THE VOLUME AND AMOUNT AS THAT ARE EXISTING PRIOR TO THE COMMENCEMENT OF CONSTRUCTION PERIOD. PROVISION MUST BE MADE TO PRESERVE THE INTEGRITY AND CAPACITY OF CHECK WEIRS, SEDIMENT BASINS, SLOPE DRAINS, GRADING PATTERNS, ETC. REQUIRED TO MEET THIS PROVISION THROUGHOUT THE LIFE OF THE CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE HAY BALES, SILT BARRIERS, TEMPORARY GRASSING, ETC. AS REQUIRED TO FULLY COMPLY WITH THE INTENT OF THIS SPECIFICATION. A)STOCKPILING MATERIAL NO EXCAVATED MATERIAL SHALL BE STOCKPILED IN SUCH A MANNER AS TO DIRECT RUNOFF DIRECTLY OFF THE PROJECT SITE OR INTO ANY ADJACENT WATER BODY OR STORMWATER COLLECTION FACILITY. B)EXPOSED AREA LIMITATION THE SURFACE AREA OF OPEN, RAW ERODABLE SOIL EXPOSED BY CLEARING AND GRUBBING OPERATIONS OR EXCAVATION AND FILLING OPERATIONS SHALL BE CONTROLLED, SO THAT THIS OPERATION WILL NOT SIGNIFICANTLY AFFECT OFFSITE DEPOSIT SEDIMENTS. C)INLET PROTECTION INLETS AND CATCH BASINS SHALL BE PROTECTED FROM SEDIMENT LADEN STORM WATER RUNOFF UNTIL THE COMPLETION OF THE ALL CONSTRUCTION OPERATIONS THAT MAY CONTRIBUTE SEDIMENT TO THE INLET. D)TEMPORARY SEEDING AREAS OPENED BY CONSTRUCTION OPERATIONS THAT ARE NOT ANTICIPATED TO BE DRESSED OR RECEIVE FINAL GRASSING TREATMENT WITHIN THIRTY (30) DAYS SHALL BE SEEDED WITH A QUICK GROWING GRASS SPECIES WHICH WILL PROVIDE AND EARLY COVER, DURING THE SEASON IN WHICH IT IS PLANTED. TEMPORARY SEEDING SHALL BE CONTROLLED SO AS TO NOT ALTER OR COMPETE WITH PERMANENT GRASSING. THE RATE OF SEEDING SHALL BE 30 POUNDS PER ACRE. E)TEMPORARY SEEDING AND MULCHING SLOPES STEEPER THAN 6:1 THAT FALL WITHIN THE CATEGORY ESTABLISHED IN 4 ABOVE, SHALL ADDITIONALLY RECEIVE MULCHING OF APPROXIMATELY TWO (2) INCHES, LOOSE MEASURE, OF MULCH MATERIAL CUT INTO THE SOIL OF THE SEEDED AREA TO A DEPTH OF FOUR (4) INCHES. F)TEMPORARY GRASSING THAT SEEDED OR SEEDED AND MULCHED AREA(S) SHALL BE ROLLED AND WATERED AS REQUIRED TO ASSURE OPTIMUM GROWING CONDITIONS FOR THE ESTABLISHMENT OF A GOOD GRASS COVER. G)TEMPORARY RE-GRASSING IF, AFTER 14 DAYS, THE TEMPORARY GRASSED AREAS HAVE NOT ATTAINED A MINIMUM OF 75% GOOD GRASS COVER, THE AREA WILL BE REWORKED AND ADDITIONAL SEEDS APPLIED TO ESTABLISH THE DESIRED VEGETATION COVER. H)MAINTENANCE ALL FEATURES OF THE PROJECT SHALL BE CONSTRUCTED TO PREVENT EROSION AND SEDIMENT AND SHALL BE MAINTAINED DURING THE LIFE OF THE CONSTRUCTION SO AS TO FUNCTION PROPERLY WITHOUT THE TRANSPORT OF SEDIMENTS OUTSIDE THE LIMITS OF THE PROJECT. 2.TEMPORARY SILT FENCES AND STAKED SILT BARRIERS, SHALL BE IN ACCORDANCE WITH F.D.O.T. STANDARD SPECIFICATION, SEC. 104.6, 104.7 AND SEC. 985. 3.THE CONTRACTOR SHALL PREPARE A STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IN ACCORDANCE WITH THE EPA NPDES (NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM) REGULATIONS PRIOR TO CONSTRUCTION. THE CONTRACTOR MUST ALSO PREPARE AND SUBMIT A NOTICE OF INTENT (NOI) FORM TO FDEP 48 HOURS PRIOR TO COMMENCING CONSTRUCTION. 4.UNDER PROVISIONS OF THE CLEAN WATER ACT. OPERATOR(S) OF CONSTRUCTION SITES, PURSUANT TO CONDITIONS OF THE NPDES PERMIT, MUST SUBMIT A NOI TO OBTAIN COVERAGE UNDER THE NPDES STORM WATER CONSTRUCTION GENERAL PERMIT. 5.NOI'S MUST BE SENT TO THE FOLLOWING ADDRESS: NPDES STORMWATER PROGRAM 2600 BLAIR STONE ROAD MAIL STATION 2500 TALLAHASSEE, FL. 32399 PHONE: (850) 245-7522 UPON SUBMITTAL TO FDEP IN TALAHASSEE, THE CONTRACTOR SHALL ALSO SUBMIT A COPY TO THE CITY ENGINEER. TRAFFIC CONTROL 1.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING A TEMPORARY TRAFFIC CONTROL PLAN (TTCP) PRIOR TO CONSTRUCTION. THE TTCP (ALSO CALLED A MAINTENANCE OF TRAFFIC (MOT) PLAN) SHALL SHOW ALL PROPOSED TRAFFIC CONTROL SIGNS, PAVEMENT MARKINGS, AND BARRICADES, AND SHALL DETAIL ALL PROPOSED CONSTRUCTION SEQUENCING. THE TTCP PLAN AND INSTALLED TRAFFIC CONTROL MEASURES SHALL BE APPROVED BY THE CITY AND THE ENGINEER. ROADWAY LANE CLOSURES AND TEMPORARY DRIVEWAY CLOSURES SHALL BE RESTRICTED TO THE HOURS BETWEEN 9:00 A.M. AND 3:00 P.M. UNLESS OTHERWISE AUTHORIZED IN THE APPROVED TTCP PLAN. DRIVEWAY CLOSURES FOR THE PURPOSES OF DIRECTIONAL DRILL CONSTRUCTION SHALL NOT EXCEED TWENTY-FOUR (24) HOURS DURATION. 2.ALL TRAFFIC CONTROL MEASURES SHALL BE IN ACCORDANCE WITH FDOT STANDARD PLANS FOR ROAD CONSTRUCTION, INDEX NO.102-600 AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). ALL TRAFFIC CONTROL MEASURES SHALL BE INSTALLED PRIOR TO CONSTRUCTION AND MAINTAINED DURING CONSTRUCTION. 3.INSPECT TRAFFIC CONTROL DEVICES ON A DAILY BASIS TO ENSURE PLACEMENT OF BARRICADES AND FUNCTION OF LIGHTS IS MAINTAINED THROUGHOUT CONSTRUCTION. 4.CONTACT PROPERTY OWNERS AFFECTED BY CONSTRUCTION. PROVIDE A MINIMUM SEVENTY-TWO (72) HOURS ADVANCE NOTICE TO THE PROPERTY OWNERS AND THE CITY OF ALL PROPOSED TEMPORARY DRIVEWAY CLOSURES. MAINTAIN ACCESS FOR ALL PROPERTY OWNERS DURING CONSTRUCTION. 5.WET UNSTABILIZED AREAS AS NECESSARY TO CONTROL DUST. 6.ADJUST TRAFFIC CONTROL DEVICES AS REQUIRED UNDER EMERGENCY CONDITIONS. 7.THE CONTRACTOR IS EXPECTED TO COORDINATE ITS ACTIVITIES WITH OTHER CONTRACTORS WHO MAY BE WORKING IN THE IMMEDIATE VICINITY. 8.WHEN WORK OCCURS ALONG TWO LANE, TWO WAY ROADS AND IS WITHIN 15-FT OF ACTIVE ROAD TRAVEL WAY BUT NO CLOSER THAN 2-FT FROM THE TRAVEL WAY, SIGNAGE AND WARNING DEVICES ARE TO BE INSTALLED IN ACCORDANCE WITH FDOT INDEX NO. 102-600 AND 102-602. WHEN WORK OCCURS ALONG TWO LANE, TWO WAY ROADS BETWEEN THE ROAD CENTERLINE AND A LINE 2-FT OUTSIDE THE EDGE OF THE TRAVEL WAY, SIGNAGE AND WARNING DEVICES ARE TO BE INSTALLED IN ACCORDANCE WITH FDOT INDEX NO. 102-600 AND 102-603. 9.TYPE I OR TYPE II BARRICADES AT 20-FT CENTERS SHALL BE PLACED AND MAINTAINED ALONG THE EDGE OF THE ROAD WHEREVER HAZARDS EXIST AND TO BLOCK ENTRANCE INTO COMPLETED OR PARTIALLY COMPLETED PAVEMENTS UNTIL SUCH PAVEMENTS ARE OPEN TO PUBLIC USE. 10.WHERE A DROP-OFF CONDITION IN THE WORK ZONE OCCURS, IT SHALL BE MITIGATED IN ACCORDANCE WITH FDOT INDEX 102-600. REFER TO FDOT INDEX NO. 102-600 FOR THE DEFINITION OF A DROP-OFF. SM H TO P = 9 1 . 1 8 N I N V = 7 7 . 1 3 S I N V = 7 8 . 8 8 NE I N V = 7 7 . 5 7 W I N V = 7 7 . 0 9 B W B W B W B W B W B W B W B W B W B W B W B W BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BR W BR W BR W B R W BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRWBRWBRWBRWBRWBRWBRW B R W B R W BR W BR W BR W BW BW BW BW BW BW BW BW BW BW BW BW BR W BR W BW BW BW B W BW BW BW BW BW BW BW BW BW BW BW BW BW BW BWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBW BW BW BWBWBW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW B W B W B W B W B W BW BW BW S S S S 16 " B R M 16" BRM 16" BRM 16" BRM 16" BRM 16" BRM 16" BRM 16" BRM 12 BW 12 BW 8" S A N 16" BRW 12" BW 12" BRW 16 " B W 16 " B W 16 " B W 1 6 " R C M 16" BRW 12" BW 12" BW 12" PW 12" PW 12" BW 12" BW 12" BW 12" BW 12" BW 12" BW 16" BRW 8" BFM S S S 16" BRW S S BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM S S 8" BFM S BFM BFMBFMBFMBFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM B F M 152+00 153+0 0 154+00 155+00 156+00 157+00 158+00 159+00 160+00 161+00 162+00 163+00 164+00 165+00 166+00 167+00 168+00 169+00 170+00 171+00 172+00 173+00 174+00 175+00 176+00 177+00 178+00 179+00 180+00 181+00 182+00 183+00 BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BFM BFM BFM BFM BFM BFM BFM B F M Drawing name: J:\O6025\Civil\DWG\_Current_Plan_Set\O6025 Key Sheet.dwg Oct 22, 2025 - 4:26pm zaadad Job No. Date: Checked by: Designed by: Drawn by: Sheet No.No.DateNo.Date Revision www.cphcorp.com C 2025 Revision 1 2 3 4 5 6 7 8 1117 East Robinson Street Orlando, FL 32801 Ph: 407.425.0452 Plans Prepared By: State of Florida Licenses: Engineer No. 3215 Surveyor No. LB7143 Architect. No. AA26000926 Landscape No. LC000298 Building BetterCommunities Together ROBERTO MARCOS GONZALEZ, P.E. P.E. LIC. # 56875 City of Ocoee Clarke Road Force Main Relocation Ocoee, Florida O6025 3/2025 RMG MEP GCM 10 0 % S U B M I T T A L KEY SHEET C-3 SHEET C-4 SHEET C-5 SHEET C-7 A . D . M I M S R D . N CLARKE RD. EXISTING LIFT STATION No. 32 PLAN SHEET No.ID NUMBER 1 CONFLICT CROSSING TABLE BOTTOM OF EXISTING PIPE ELEVATION 2 3 C-5 4 C-5 5 C-7 6 84.95 (RWM) 81.76 (SAN) 89.0 (WM) 91.20 (RWM) 119.60 (SAN) C-4 C-4 CONFLICT ID NUMBER #1 (SEE SHEET C-3) CONFLICT ID NUMBER #2 (SEE SHEET C-3) CONFLICT ID NUMBER #3 (SEE SHEET C-3) CONFLICT ID NUMBER #4 (SEE SHEET C-3) CONFLICT ID NUMBER #5 (SEE SHEET C-3) CONFLICT ID NUMBER #6 (SEE SHEET C-3) TOP OF NEW FORCE PIPE ELEVATION SEPARATION 78.80 6.15' 78.80 2.96' 82.70 6.3' 87.00 4.20' 116.68 2.92' C-7 127.00 (WM)121.57 5.43' OC O E E VI S T A P K W Y PROPOSED 10" DR 11 HDPE FORCE MAIN PROPOSED 8" PVC FORCE MAIN WM EXISTING BURIED WATER LEGEND PROPOSED FORCE MAIN BTV EXISTING BURIED TV BRW EXISTING BURIED RECLAIMED WATER SAN EXISTING GRAVITY SANITARY SEWER BFO EXISTING BURIED FIBER OPTIC BFM EXISTING BURIED FORCE MAIN TO BE ABANDON IN PLACE BFM BRW BW SAN BTV BE EXISTING BURIED ELECTRICBE PROPOSED DIRECTIONAL FORCE MAIN EXISTING FORCE MAIN FM BFO EXISTING BURIED TELECOMM FM RIGHT OF WAY BT BE EXISTING BURIED TRAFFIC ELECTRICALBTE EXISTING WATER VALVE EXISTING BACK FLOW PREVENTER EXISTING FIRE HYDRANT 7 C-5 87.21 (SAN)83.76 3.45' CONFLICT ID NUMBER #7 (SEE SHEET C-5) 30 Scale 73 75 78 81 84 87 90 93 96 99 73 75 78 81 84 87 90 93 96 99 161+00 162+00 163+00 164+00 165+00 166+00 167+00 168+00 169+00 OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW O H W O H W O H W OH W OH W OH W OH W OH W B T V BTV BT V BT V BT V BT V BT V B F O BFO BF O BF O BF O BF O BF O B T BT BT BT BT BT BT BT B E BT BT BT BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BT BT BT BT BT BT B T B W B W BW B W B W BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBW BW BW BW BW BW BW BW BW BW 12" PW 12" PW 12" BW S 16" BRW BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM B T V BTV BT V BT V BT V BT V BT V B F O BFO BF O BF O BF O BF O BF O B T BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT B T B T V BTV BT V BT V BT V BT V BT V B F O BFO BF O BF O BF O BF O BF O B T BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT B T 8" BFM S BFM BFM BFM BFMBFMBFMBFMBFMBFMBFM BFM BFM BFM BFM BFM BFM 161+00 162+00 163+00 164+00 165+00 166+00 167+00 168+00 169+00 BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW B R W Drawing name: J:\O6025\Civil\DWG\_Current_Plan_Set\O6025 Plan and Profiles.dwg Oct 22, 2025 - 4:50pm zaadad Job No. Date: Checked by: Designed by: Drawn by: Sheet No.No.DateNo.Date Revision www.cphcorp.com C 2025 Revision 1 2 3 4 5 6 7 8 1117 East Robinson Street Orlando, FL 32801 Ph: 407.425.0452 Plans Prepared By: State of Florida Licenses: Engineer No. 3215 Surveyor No. LB7143 Architect. No. AA26000926 Landscape No. LC000298 Building BetterCommunities Together ROBERTO MARCOS GONZALEZ, P.E. P.E. LIC. # 56875 City of Ocoee Clarke Road Force Main Relocation Ocoee, Florida O6025 3/2025 RMG MEP GCM 10 0 % S U B M I T T A L PLAN AND PROFILE STA.161+00 TO STA. 169+00 C-4 N 0 Graphic Scale in Feet 30 30 60 N. CLARKE ROAD M A T C H L I N E S T A . 1 6 1 + 0 0 MA T C H L I N E S T A . 1 6 9 + 0 0 INSTALL ± 595 L.F. OF 10" DR 11 HDPE FORCE MAIN VIA DIRECTIONAL BORE RIGHT OF WAY RIGHT OF WAY EXISTING GRADE INSTALL 10" DR 11 HDPE FORCE MAIN DIRECTIONAL BORE GROUT FILL AND ABANDON IN PLACE ± 461 L.F. OF 8" FORCE MAIN SEE DETAIL A, ON SHEET C-9 SEE DETAIL B, ON SHEET C-9 EXISTING 8" SAN. SEWER EXISTING 8" SAN. SEWER EXISTING 16" RWM EXISTING 8" FM EXISTING 12" WM EXISTING 8" FORCE MAIN (SEE NORTH CLARKE ROAD WIDENING PLANS FOR DETAILS) MAINTAIN 3' MIN. HORIZONTAL SEPARATION FROM BRWM NOTES: 1.CONTRACTOR TO COORDINATE WITH THE CITY ON LOCATION OF LAYDOWN YARD FOR HDPE PIPE. 2.CONTRACTOR TO PROVIDED SIGNED AND SEALED DRILLING PLAN PRIOR TO CONSTRUCTION. 3.CONTRACTOR TO COORDINATE WITH THE CITY ON BYPASSING LIFT STATION No. 32 DURING THE PROPOSED CONNECTION USING PUMP TRUCKS. THE BYPASS SHALL BE PERFORMED BY GODWIN PUMPS (CONTACT: CHRIS DOVER, 386-234-0753, chris.dover@xylem.com) 4.CONTRACTOR SHALL COORDINATE WITH CITY TO REPLACE SIDEWALK PANELS WITH UNEVEN SURFACES/ CRACKS WITHIN THE PROJECT AREA CONFLICT ID NUMBER # 1 (SEE SHEET C-3) INSTALL 8" PLUG VALVE STA. 163+08 (52' RT.) INSTALL 8" 45° BEND 10' x 50' DIRECTIONAL DRILL PIT INSTALL (2) 8" 45° BENDS 10" 11.25° BEND FUSED END MECHANICAL JOINT INSTALL 10" x 8" REDUCER CONNECT TO 8" FORCE MAIN WITH 45° BEND INSTALL ± 14 L.F. OF 8" PVC FORCE MAIN GROUT FILL AND ABANDON IN PLACE ± 160 L.F. OF 8" FORCE MAIN STA. 163+05 (58' RT.) INSTALL 8" 45° BEND STA. 163+35 (57' RT.) INSTALL 10" FUSED END MECHANICAL JOINT STA. 163+31 (57' RT.) INSTALL 10" x 8" REDUCER STA. 163+26 (57' RT.) INSTALL 8" PLUG VALVE REMOVE AND REPLACE ±57 S.Y. OF SIDEWALK CONFLICT ID NUMBER # 2 (SEE SHEET C-3) 8' M I N . EXISTING FORCE MAIN (PREVIOUSLY GROUTED AND ABANDONED BY OTHERS) EXISTING BURIED WATER LEGEND PROPOSED FORCE MAIN EXISTING BURIED TV EXISTING BURIED RECLAIMED WATER EXISTING GRAVITY SANITARY SEWER EXISTING BURIED FIBER OPTIC EXISTING BURIED FORCE MAIN TO BE ABANDON IN PLACE BFM BRW BW SAN BTV EXISTING BURIED ELECTRICBE PROPOSED DIRECTIONAL FORCE MAIN EXISTING FORCE MAIN BFO EXISTING BURIED TELECOMM FM RIGHT OF WAY BT EXISTING BURIED TRAFFIC ELECTRICALBTE EXISTING WATER VALVE EXISTING BACK FLOW PREVENTER EXISTING FIRE HYDRANT 11° DRILL RIG ANGLE REPLACE ±22 SY OF ASPHALT ROADWAY AND ±25 LF OF CURB AS NECESSARY TO INSTALL FORCE MAIN 8" PVC OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW O H W O H W O H W V V OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW R R R R B E BE B E B E BE BE BE BE BE BE B E BE BE BE B E B E B E B E BE BE BE BE BE BE B E B E B E B E BE BE B E B E B E B E B E B E B E B E BT BT BT BT BT BT BT BT BT B T BTV BT V BT V BT V BT V BT V BT V B T V B T V BE BE B E B E BE BE BE BE BE BE BE BE BE BE BE BE BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW B R W B R W B R W B R W B R W B R W BR W B R W BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRW BRWBRWBRWBRWBRWBRW BW BW BW BW BW BW BW BW BW BW BR W BR W BR W BR W BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBW 16" BR M 16" BRM 16" BRM 16" BRM 12 BW 12 BW 12" BW S S BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BTBTBTBTBTBTBTBTBTBT B T BTBTBTBTBTBTBTBTBT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BT BTBTBTBTBTBTBTBTBTBT B T BTBTBTBTBTBTBTBTBT S S 169+00 170+00 171+00 172+00 173+00 174+00 175+00 176+00 177+00 BFM BFM BFM Drawing name: J:\O6025\Civil\DWG\_Current_Plan_Set\O6025 Plan and Profiles.dwg Oct 22, 2025 - 4:47pm zaadad Job No. Date: Checked by: Designed by: Drawn by: Sheet No.No.DateNo.Date Revision www.cphcorp.com C 2025 Revision 1 2 3 4 5 6 7 8 1117 East Robinson Street Orlando, FL 32801 Ph: 407.425.0452 Plans Prepared By: State of Florida Licenses: Engineer No. 3215 Surveyor No. LB7143 Architect. No. AA26000926 Landscape No. LC000298 Building BetterCommunities Together ROBERTO MARCOS GONZALEZ, P.E. P.E. LIC. # 56875 City of Ocoee Clarke Road Force Main Relocation Ocoee, Florida O6025 3/2025 RMG MEP GCM 10 0 % S U B M I T T A L PLAN STA.169+00 TO STA.177+00 C-5 0 Graphic Scale in Feet 30 30 60 N MA T C H L I N E S T A . 1 6 9 + 0 0 M A T C H L I N E S T A . 1 7 7 + 0 0 N. CLARKE RO A D O C O E E V I S T A P A R K W A Y M A R S H P A L M P A R K W A Y RIGHT OF WAY RIGHT OF WAY GROUT AND ABANDONED IN PLACE ±807 L.F. OF 8" FORCE MAIN SEE DETAIL C, ON SHEET C-9 SEE DETAIL D, ON SHEET C-9 SEE DETAIL E, ON SHEET C-9 CONFLICT ID NUMBER #3 SEE SHEET C-3) CONFLICT ID NUMBER #4 (SEE SHEET C-3) CONFLICT ID NUMBER #7 (SEE SHEET C-3) INSTALL ±867 L.F. OF 10" DR 11 HDPE FORCE MAIN VIA DIRECTIONAL BORE GROUT AND ABANDONED IN PLACE ±807 L.F. OF 8" FORCE MAIN NOTES: 1.CONTRACTOR TO COORDINATE WITH THE CITY ON LOCATION OF LAYDOWN YARD FOR HDPE PIPE. 2.CONTRACTOR TO PROVIDED SIGNED AND SEALED DRILLING PLAN PRIOR TO CONSTRUCTION. 3.CONTRACTOR TO COORDINATE WITH THE CITY ON BYPASSING LIFT STATION No. 32 DURING THE PROPOSED CONNECTION USING PUMP TRUCKS. THE BYPASS SHALL BE PERFORMED BY GODWIN PUMPS (CONTACT: CHRIS DOVER, 386-234-0753, chris.dover@xylem.com) 4.CONTRACTOR SHALL COORDINATE WITH CITY TO REPLACE SIDEWALK PANELS WITH UNEVEN SURFACES/ CRACKS WITHIN THE PROJECT AREA EXISTING BURIED WATER LEGEND PROPOSED FORCE MAIN EXISTING BURIED TV EXISTING BURIED RECLAIMED WATER EXISTING GRAVITY SANITARY SEWER EXISTING BURIED FIBER OPTIC EXISTING BURIED FORCE MAIN TO BE ABANDON IN PLACE BFM BRW BW SAN BTV EXISTING BURIED ELECTRICBE PROPOSED DIRECTIONAL FORCE MAIN EXISTING FORCE MAIN BFO EXISTING BURIED TELECOMM FM RIGHT OF WAY BT EXISTING BURIED TRAFFIC ELECTRICALBTE EXISTING WATER VALVE EXISTING BACK FLOW PREVENTER EXISTING FIRE HYDRANT 30 Scale 73 75 78 81 84 87 90 93 96 99 102 105 108 111 114 117 120 123 126 129 73 75 78 81 84 87 90 93 96 99 102 105 108 111 114 117 120 123 126 129 169+00 170+00 171+00 172+00 173+00 174+00 175+00 176+00 177+00 Drawing name: J:\O6025\Civil\DWG\_Current_Plan_Set\O6025 Plan and Profiles.dwg Oct 22, 2025 - 4:47pm zaadad Job No. Date: Checked by: Designed by: Drawn by: Sheet No.No.DateNo.Date Revision www.cphcorp.com C 2025 Revision 1 2 3 4 5 6 7 8 1117 East Robinson Street Orlando, FL 32801 Ph: 407.425.0452 Plans Prepared By: State of Florida Licenses: Engineer No. 3215 Surveyor No. LB7143 Architect. No. AA26000926 Landscape No. LC000298 Building BetterCommunities Together ROBERTO MARCOS GONZALEZ, P.E. P.E. LIC. # 56875 City of Ocoee Clarke Road Force Main Relocation Ocoee, Florida O6025 3/2025 RMG MEP GCM 10 0 % S U B M I T T A L PROFILE STA.169+00 TO STA.177+00 C-6 EXISTING GRADE INSTALL 10" DR 11 HDPE FORCE MAIN DIRECTIONAL BORE EXISTING 16" RWM SCALE: 1" = 30' HOR. 1" = 3' VERT. EXIS T I N G 8 " S A N . S E W E R EXISTING 8" WATER EXISTING 16" x 8" TEE EXISTING 16" x 8" TEE 8 ' M I N . EXISTING 8" FM OHW OHW OHW OHW OHW OHW OHW OHW OHW OH W OH W OH W OH W OHWOHW V TS B TS B TS B OH W OH W OH W OH W OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW R R R R SITE B E N C H M A R K # 4 1/2" IR O N R O D / C A P , "LB67 2 3 " ELEVA T I O N = 1 3 2 . 3 6 ' BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BFO BFO BFO BFO BFO BFO BFO BFO BFO BF O BF O BTV BTV BTV BF O BF O BFO BFOBFOBFO BFOBFOBFO B F OBFO CONDCONDCONDCONDCONDCONDCONDCONDCOND CONDCONDCONDCOND BFMBFMBFMBFMBFM BFM BFMBFMBFM BF M BF M BF M BEBEBEBEBEBEBE BE BEBEBE BF O BF O BF O BF O BF O BF O BF O BF O BF O BF O BF O BF O BF O BF O BTE BTE BT E BT E BT E BT E BT E BT E BT E BG BG BG BG BG BG BG BG BG BG BG BG BG BG B T E BT E BT E BT E BT E BT E BT E BT E BTE BTE BTE B T E BT E BT E BT E BT E BT E BT E BT E B T E B T E BT E BTE BTE BT E BT E BTEBTE B T E BTE BGBGBG B G B G BRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRWBRW BR W BR W BR W BR W BR W BR W BR W BR W BRW BFO BFO BFO BFO BFO BFO BFO BFO BFO BF O BF O BT V BT V BTVBTVBTVBTVBTVBTVBTVBTVBTV BT E BT E BT E BT E BTE BTE BTE BT E B T E B T E B T E BT E BT E BT E BT E BT E BT E BTE BT E BT E BT E BF O BF O BF O B F O BFO BFO B F O BF O BF O BF O BF O BF O BFO BWBWBW BW BW BWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBWBW BW BW BW BW BW BW BW BW BW BW B W B W BW BW BW BTE BTE BTE S 16" B R M 16" BRM 16" BRM16" BRM 8" S A N 12" BW 12" BRW 16 " B W 20 " B F W 16 " R C M 16" BRW 12" BW BTBT BT BTBTBTBTBTBT BT BTBT BT BTBTBTBTBTBTBTBTBTBTBTBTBTBTBTBTBT BTBT BT BTBTBTBTBTBT BT BTBT BT BTBTBTBTBTBTBTBTBTBTBTBTBTBTBTBTBT 177+00 178+00 179+00 180+00 181+00 182+00 BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM B F M B F M 30 Scale 108 111 114 117 120 123 126 129 132 135 108 111 114 117 120 123 126 129 132 135 177+00 178+00 179+00 180+00 181+00 182+00 182+50 Drawing name: J:\O6025\Civil\DWG\_Current_Plan_Set\O6025 Plan and Profiles.dwg Oct 22, 2025 - 4:47pm zaadad Job No. Date: Checked by: Designed by: Drawn by: Sheet No.No.DateNo.Date Revision www.cphcorp.com C 2025 Revision 1 2 3 4 5 6 7 8 1117 East Robinson Street Orlando, FL 32801 Ph: 407.425.0452 Plans Prepared By: State of Florida Licenses: Engineer No. 3215 Surveyor No. LB7143 Architect. No. AA26000926 Landscape No. LC000298 Building BetterCommunities Together ROBERTO MARCOS GONZALEZ, P.E. P.E. LIC. # 56875 City of Ocoee Clarke Road Force Main Relocation Ocoee, Florida O6025 3/2025 RMG MEP GCM 10 0 % S U B M I T T A L PLAN AND PROFILE STA.177+00 TO STA.182+50 C-7 0 Graphic Scale in Feet 30 30 60 MA T C H L I N E S T A . 1 7 7 + 0 0 N RIGHT OF WAY CLARKE ROAD A. D . M I M S RO A D STA. 179+50 (51' RT.) INSTALL 10" FUSED END MECHANICAL JOINT STA. 180+43 (57' RT.) INSTALL 8" 45° BEND 10' UTILITY EASEMENT STA. 181+10 (99' RT.) INSTALL 20" x 8" TAPPING SLEEVE & VALVE JACK AND BORE ± 41 L.F. OF 20" STEEL CASING (0.5" WALL THICKNESS) WITH ± 55 L.F. OF 8" RESTRAINED PVC FM CARRIER PIPE APPROXIMATE LOCATION OF 40' x 15' JACKING PIT JACK AND BORE RECEIVING PIT 10' x 15' INSTALL 279L.F. OF 10" DR 11 HDPE FORCE MAIN VIA DIRECTIONAL BORE INSTALL ± 211 L.F. OF 8" PVC FORCE MAIN EXISTING GRADE INSTALL 8" PLUG VALVE INSTALL 20" x 8" TAPPING SLEEVE & VALVE INSTALL (2) 8" 45° BENDS JACK AND BORE ± 41 L.F. OF 20" STEEL CASING (0.5" WALL THICKNESS) WITH ± 55 L.F. OF 8" RESTRAINED PVC FM CARRIER PIPE 60' RAILROAD RIGHT OF WAY INSTALL 10" DR 11 HDPE FORCE MAIN DIRECTIONAL BORE 10" 11.25° BENDS FUSED END MECHANICAL JOINT INSTALL 8" PLUG VALVE 60' RAILROAD RIGHT OF WAY INSTALL 10" x 8" REDUCER STA. 179+60 (52' RT.) INSTALL 8" PLUG VALVE STA. 179+54 (52' RT.) INSTALL 10" x 8" REDUCER INSTALL 8" PVC FORCE MAIN EXISTING 8" WATER MAIN 6. 9 ' STA. 181+00 (99' RT.) INSTALL 8" PLUG VALVE CONFLICT ID NUMBER #5 (SEE SHEET C-3) CONFLICT ID NUMBER #6 (SEE SHEET C-3) REMOVE AND REPLACE ±111 S.Y. OF SIDEWALK 10' x 50' DIRECTIONAL DRILL PIT STA. 180+35 (50' RT.) INSTALL 8" 45° BEND SEE SHEET C-8A FOR DETAILS EXISTIN G 8 " S A N . S E W E R APPROXIMATE ELEVATION EXISTING LOCATION OF FCEN ROAD RAIL JA C K & B O R E D E P T H GROUT AND ABANDONED IN PLACE ±410 L.F. OF 8" FORCE MAIN EXISTING 8" FM NOTES: 1.CONTRACTOR TO COORDINATE WITH THE CITY ON LOCATION OF LAYDOWN YARD FOR HDPE PIPE. 2.CONTRACTOR TO PROVIDED SIGNED AND SEALED DRILLING PLAN PRIOR TO CONSTRUCTION. 3.CONTRACTOR TO COORDINATE WITH THE CITY ON BYPASSING LIFT STATION No. 32 DURING THE PROPOSED CONNECTION USING PUMP TRUCKS. 4.CONTRACTOR SHALL COORDINATE WITH CITY TO REPLACE SIDEWALK PANELS WITH UNEVEN SURFACES/ CRACKS WITHIN THE PROJECT AREA 5.SEE DETAIL FOR CITY STANDARD AIR RELEASE VAULT. 6.CONTRACTOR TO PROVIDE TEMPORARY BYPASS (APPROVED BY THE CITY) AS NECESSARY TO INSTALL FORCE MAIN BETWEEN STA 179+50 AND STA 180+50. 7.CONTRACTOR TO INSTALL 48" ROOT BARRIER FOR LOCATION WHERE EXISTING LANDSCAPE IS CLOSE TO THE PROPOSED FORCE MAIN. 8.CONTRACTOR TO CLEAR AND GRUB EASEMENT AREA AS NECESSARY TO INSTALL FORCE MAIN. 20' x 25' TEMPORARY CONSTRUCTION EASEMENT STA. 180+41 (76' RT.) INSTALL 2" AIR RELEASE VALVE 11° DRILL RIG ANGLE EXISTING ARV VAULT (TO BE ABANDONED) EXISTING BURIED WATER LEGEND PROPOSED FORCE MAIN EXISTING BURIED TV EXISTING BURIED RECLAIMED WATER EXISTING GRAVITY SANITARY SEWER EXISTING BURIED FIBER OPTIC EXISTING BURIED FORCE MAIN TO BE ABANDON IN PLACE BFM BRW BW SAN BTV EXISTING BURIED ELECTRICBE PROPOSED DIRECTIONAL FORCE MAIN EXISTING FORCE MAIN BFO EXISTING BURIED TELECOMM FM RIGHT OF WAY BT EXISTING BURIED TRAFFIC ELECTRICALBTE EXISTING WATER VALVE EXISTING BACK FLOW PREVENTER EXISTING FIRE HYDRANT OHW OH W OH W OH W OH W OH W OHWOHWOHWOHWOHWOHW OH W OH W OH W OH W BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFOBFOBFOBFOBFOBFOBFO BFO BFO BFO BFOBFOBFOBFOBFOBFO B F O B F O B F O BFOBFOBFOBFO CONDCONDCONDCONDCONDCONDCONDCONDCONDCOND COND COND CONDCONDCONDCONDCONDCONDCONDCONDCONDCONDCONDCOND BFM BFM BFM BFMBFMBFMBFMBFMBFMBFM BFM BF M BF M BF M BEBEBEBEBEBEBEBEBEBEBEBEBE BE BE BE BE BE BEBEBEBEBEBEBEBEBE BF O BF O BF O BF O BF O BF O BF O BF O BF O BF O BF O BF O BF O BF O BTE BTE BTE BTE BTE BTE B T E BT E BT E BT E BT E BG BG BG BG BT E B T E BT E BT E BT E BT E BTE BTE BTE BTE BTE BTE BTE B T E BT E BTE BT E BT E BT E BT E BT E BT E BT E BT E BT E BT E BT E BR W BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BFO BTVBTVBTVBTVBTVBTVBTVBTVBTVBTVBTVBTVBTVBTVBTVBTVBTV BTV BTVBTVBTVBTVBTVBTV BT E BT E BT E BT E BT E BT E BTE BTE BTE BTE BTE BTE BTE BTE BTE BT E BTE BTE 16 " B W BTBTBTBTBTBTBTBTBTBT BT BT BT BT BTBTBTBTBT BT BT BT BT BTBTBTBTBTBTBTBT BTBTBTBTBTBTBTBTBTBT BT BT BT BT BTBTBTBTBT BT BT BT BT BTBTBTBTBTBTBTBT BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM BFM B F M B F M B F M B F M B F M B F M B F M 30 Scale 108 111 114 117 120 123 126 129 132 135 180+00 181+00 182+00 182+50 Drawing name: J:\O6025\Civil\DWG\_Current_Plan_Set\O6025 Plan and Profiles.dwg Oct 16, 2025 - 9:40am zaadad Job No. Date: Checked by: Designed by: Drawn by: Sheet No.No.DateNo.Date Revision www.cphcorp.com C 2025 Revision 1 2 3 4 5 6 7 8 1117 East Robinson Street Orlando, FL 32801 Ph: 407.425.0452 Plans Prepared By: State of Florida Licenses: Engineer No. 3215 Surveyor No. LB7143 Architect. No. AA26000926 Landscape No. LC000298 Building BetterCommunities Together ROBERTO MARCOS GONZALEZ, P.E. P.E. LIC. # 56875 City of Ocoee Clarke Road Force Main Relocation Ocoee, Florida O6025 3/2025 RMG MEP GCM 10 0 % S U B M I T T A L RAILROAD CROSSING C-8 0 Graphic Scale in Feet 10 10 20 MA T C H L I N E S T A . 1 7 8 + 0 0 N EXISTING GRADE INSTALL 8" PLUG VALVE INSTALL 20" x 8" TAPPING SLEEVE & VALVE INSTALL (2) 8" 45° BENDS 60' RAILROAD RIGHT OF WAY CUT AND CAPPED BOTH ENDS OF EXISTING ABANDON FORCE MAIN CLARKE ROAD A. D . M I M S RO A D STA. 180+43 (96' RT.) INSTALL 8" 45° BEND APPROXIMATE LOCATION OF 15' x 40' JACKING PIT JACK AND BORE RECEIVING PIT 10' x 15' STA. 181+10 (99' RT.) INSTALL 20" x 8" TAPPING SLEEVE & VALVE 8" PLUG VALVE CUT AND CAPPED BOTH ENDS OF EXISTING FORCE MAIN 10' UTILITY EASEMENT NOTES: 1.CONTRACTOR TO COORDINATE WITH THE CITY ON LOCATION OF LAYDOWN YARD FOR HDPE PIPE. 2.CONTRACTOR TO PROVIDED SIGNED AND SEALED DRILLING PLAN PRIOR TO CONSTRUCTION. 3.CONTRACTOR TO COORDINATE WITH THE CITY ON BYPASSING LIFT STATION No. 32 DURING THE PROPOSED CONNECTION USING PUMP TRUCKS. THE BYPASS SHALL BE PERFORMED BY GODWIN PUMPS (CONTACT: CHRIS DOVER, 386-234-0753, chris.dover@xylem.com) 4.CONTRACTOR SHALL COORDINATE WITH CITY TO REPLACE SIDEWALK PANELS WITH UNEVEN SURFACES/ CRACKS WITHIN THE PROJECT AREA 5.REFER TO ENGINEERING SPECIFICATIONS IN THE APPLICATION PACKAGE FOR ADDITIONAL INFORMATION AND GUIDANCE. 6.FOR JACK AND BORE INSTALLATIONS "THE FRONT OF THE CASING PIPE SHALL BE PROVIDED WITH MECHANICAL ARRANGEMENTS OR DEVICES THAT WILL POSITIVELY PREVENT THE AUGER FROM LEADING THE PIPE SO THAT NO UNSUPPORTED EXCAVATION IS AHEAD OF THE PIPE." 7.LOCATE CSX'S SIGNAL FACILITIES AND /OR WARNING DEVICES AT PROPOSED FACILITY CROSSING LOCATION. I.E. CANTILEVERS, FLASHERS, GATES AND SHOW CLEARANCES. 8.CASING PIPE ENDS MUST BE SEALED. 9.MINIMUM ALLOWABLE VERTICAL DISTANCE CSX RAIL IS 5.5 FT. 10.MINIMUM YIELD POINT STRENGTH OF 35,000 PSI ASTM A 252 GRADE 2 OF ASTM A 139 GRADE B. 0.344" WALL THICKNESS. 11.CONTRACTOR TO COORDINATE WITH PROPERTY OWNER FOR TEMPORARY CONSTRUCTION EASEMENT FOR JACK AND BORE. Sanitary Sewer Force Main 75 PSI X CSXT Pipeline Spec. Reference PIPELINE CONTENT DETAILS Commodity Description: Maximum Operating Pressure: Is Commodity Flammable: Yes No CARRIER/CASING PIPE DETAILS Carrier Pipe Casing Pipe Pipe Material: Material Specifications & Grade: Specified Minimum Yield Strength: Nominal Size Outside Diameter (Inches): Wall Thickness (Inches): Type of Seam: Type of Joints: Tunnel Liner Plates Required: Yes No Cathodic Protection: Yes No Type: _______________________ Protective Coating: Yes No Type: _______________________ Temp. Track Support or Rip-Rap Req.: Yes No Must Describe & Show on Dwg. X X X X 9.05 0.503 N/A Restrained Steel 35,000 PSI 20 0.344" N/A Welded ASTM A252 or ASTM A139 4,000 DR-18 PVC 60' RAILROAD RIGHT OF WAY JACK AND BORE ± 41 L.F. OF 20" STEEL CASING (0.5" WALL THICKNESS) WITH ± 55 L.F. OF 8" RESTRAINED PVC FM CARRIER PIPE 6. 9 ' JACK AND BORE ± 41 L.F. OF 20" STEEL CASING (0.5" WALL THICKNESS) WITH ± 55 L.F. OF 8" RESTRAINED PVC FM CARRIER PIPE STA. 180+35 (50' RT.) INSTALL 8" 45° BEND STA. 181+00 (99' RT.) INSTALL 8" PLUG VALVE INSTALL 8" PVC FORCE MAIN 14' GROUT AND ABANDONED IN PLACE ±65 L.F. OF 8" FORCE MAIN STA. 180+43 (50' RT.) INSTALL 8" 45° BEND STA. 180+47 (96' RT.) INSTALL 8" 45° BEND APPROXIMATE ELEVATION EXISTING LOCATION OF FCEN ROAD RAIL JA C K & B O R E D E P T H 20' x 25' TEMPORARY CONSTRUCTION EASEMENT EXISTING BURIED WATER LEGEND PROPOSED FORCE MAIN EXISTING BURIED TV EXISTING BURIED RECLAIMED WATER EXISTING GRAVITY SANITARY SEWER EXISTING BURIED FIBER OPTIC EXISTING BURIED FORCE MAIN TO BE ABANDON IN PLACE BFM BRW BW SAN BTV EXISTING BURIED ELECTRICBE PROPOSED DIRECTIONAL FORCE MAIN EXISTING FORCE MAIN BFO EXISTING BURIED TELECOMM FM RIGHT OF WAY BT EXISTING BURIED TRAFFIC ELECTRICALBTE EXISTING WATER VALVE EXISTING BACK FLOW PREVENTER EXISTING FIRE HYDRANT Drawing name: J:\O6025\Civil\DWG\_Current_Plan_Set\O6025 Plan and Profiles.dwg Oct 16, 2025 - 9:40am zaadad Job No. Date: Checked by: Designed by: Drawn by: Sheet No.No.DateNo.Date Revision www.cphcorp.com C 2025 Revision 1 2 3 4 5 6 7 8 1117 East Robinson Street Orlando, FL 32801 Ph: 407.425.0452 Plans Prepared By: State of Florida Licenses: Engineer No. 3215 Surveyor No. LB7143 Architect. No. AA26000926 Landscape No. LC000298 Building BetterCommunities Together ROBERTO MARCOS GONZALEZ, P.E. P.E. LIC. # 56875 City of Ocoee Clarke Road Force Main Relocation Ocoee, Florida O6025 3/2025 RMG MEP GCM 10 0 % S U B M I T T A L DETAILS C-9 BR W BR W BR W BR W BW BW BW BW BW BF M BF M BF M BF M BR W BR W BR W BR W B R W B R W BR W BR W BT BT BT BT BT BT BT BT BT B T B T B T B T B T B T B T B T B T B T B T B T B T B T N.T.S. 1 C-5 DETAIL - A C-9 AT STA. 164+77 N.T.S. 2 C-5 DETAIL - B C-9 N.T.S. 3 C-6 DETAIL - C C-9 AT STA. 167+50 AT STA. 171+00 N.T.S. 4 C-6 DETAIL - D C-9 N.T.S. 5 C-6 DETAIL - E C-9 AT STA. 174+00 AT STA. 176+24 EXISTING BURIED WATER LEGEND PROPOSED FORCE MAIN EXISTING BURIED RECLAIMED WATER BT EXISTING BURIED TELECOMM BFM BRW BW PROPOSED DIRECTIONAL FORCE MAIN EXISTING BURIED FORCE MAIN TO BE ABANDON IN PLACE EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF PAVEMENT EDGE OF PAVEMENT EXISTING 8" FORCE MAIN TO BE ABANDON IN PLACE 18" RCP 18" RCP 18" RCP 18" RCP 18" RCP NNN EXISTING STORM WATER INLETS N N 4.4' FROM STRUCTURE BOTTOM 4.3' FROM STRUCTURE B O T T O M ± 5.4' FROM STRUCTUR E B O T T O M ± 3.4' FROM STRUCTURE BOTTOM ± 3.9' FROM STRUCTURE BOTTOM DIRECTIONAL BORE DETAIL 1. DEPTH OF DIRECTIONAL BORE SHALL BE APPROVED ON A CASE BY CASE BASIS. 2. CONTRACTOR MUST COMPLY WITH ALL APPLICABLE FDOT, DEP, ACOE, AND WATER MANAGEMENT DISTRICT REQUIREMENTS. NOTES: 3' M I N I M U M CO V E R SCALE: NONE APPROPRIATE VALVE REQUIRED ON BOTH SIDES OF DIRECTIONAL BORE FUSED END MECHANICAL JOINT ADAPTER SDR-11 HIGH DENSITY POLYETHYLENE 10" x 8" REDUCER Drawing name: J:\O6025\Civil\DWG\_Current_Plan_Set\O6025 Standard Details.dwg Oct 16, 2025 - 9:47am zaadad Job No. Date: Checked by: Designed by: Drawn by: Sheet No.No.DateNo.Date Revision www.cphcorp.com C 2025 Revision 1 2 3 4 5 6 7 8 1117 East Robinson Street Orlando, FL 32801 Ph: 407.425.0452 Plans Prepared By: State of Florida Licenses: Engineer No. 3215 Surveyor No. LB7143 Architect. No. AA26000926 Landscape No. LC000298 Building BetterCommunities Together ROBERTO MARCOS GONZALEZ, P.E. P.E. LIC. # 56875 City of Ocoee Clarke Road Force Main Relocation Ocoee, Florida O6025 3/2025 RMG MEP GCM 10 0 % S U B M I T T A L STANDARD DETAILS C-10 Drawing name: J:\O6025\Civil\DWG\_Current_Plan_Set\O6025 Standard Details.dwg Oct 16, 2025 - 9:48am zaadad Job No. Date: Checked by: Designed by: Drawn by: Sheet No.No.DateNo.Date Revision www.cphcorp.com C 2025 Revision 1 2 3 4 5 6 7 8 1117 East Robinson Street Orlando, FL 32801 Ph: 407.425.0452 Plans Prepared By: State of Florida Licenses: Engineer No. 3215 Surveyor No. LB7143 Architect. No. AA26000926 Landscape No. LC000298 Building BetterCommunities Together ROBERTO MARCOS GONZALEZ, P.E. P.E. LIC. # 56875 City of Ocoee Clarke Road Force Main Relocation Ocoee, Florida O6025 3/2025 RMG MEP GCM 10 0 % S U B M I T T A L STANDARD DETAILS C-11