Loading...
HomeMy WebLinkAboutResolution - Regulates Mechanical Contractors H r > l /P<:ddl14t S ~ L C'l-t C/ I? Gc d'7 6 He, yo ~ cJ /187 8rJ RESOLUTION CITY OF OCOEE, FLORIDA \ t << A RESOLUTION AMMENDING ORDINANCE NUMBER 639, OF THE CITY OF OCOEE, FLORIDA, WHICH CONTROLS AND REGU- LATES MECHANICAL CONTRACTORS AND MECHANICAL INSTALLATIONS, BY CHANGING THE STANDARDS ADOPTED FROM THOSE OF THE SOUTHERN STAN- DARD MECHANICAL CODE, 1973 EDITION, TO THOSE OF THE STANDARD MECHANICAL CODE, 1979 EDITION, AND PROVIDING FOR AN EFFECTIVE DATE. e BE IT RESOLVED by the Board of City Commissioners of the City of Ocoee, Florida, as follows: Section 1. That Section Forty One of Ordinance number 639 be amended to read as follows: "SECTION FORTY ONE. Standards Adopted. There is hereby adopted by the City for the purpose of establishing and prescribing installations, extension, repair, alteration, maintenance and removal of all mechanical systems and devices within the jurisdiction of the City, those certain standards known as the Standard Mechanical Code, 1979 Edition, and other regulations that may be adopted by resolution of the Board of City Com- missioners. "In no case shall any insulation be installed which is of itself combustible or is covered with a combustible material. "In every case where no specific type or class of materials, or no specific standards of construction are prescribed herein, then conformity with the reference standards as listed in the Appendix of the American Society of Heating, Refrigeration and Air Conditioning Engineers Standards shall be prima facie evidence of conformity with approved standards of construction for safety to health, life and property. "Suspension of air handling units, furnaces or similar equipment in attics must be from top chord of trusses with properly designed hanger to support the load. "All such units must have an emergency drain pan two (2") inches wider than unit on all sides and two(2") inches in depth installed underneath the unit; A drain not smaller than three-fourths inch in diameter from this pan must terminate at a readily visible point outside the building or approved suitable safety switch in the drain pan. e "A service platform not less than two (2') feet wide by six (6') feet, zero (0") inches, long shall be provided on the service side of the equipment connected to the attic access by not less than two(2') feet,zero (0") inches, wide by one-half inch thick wood walk. "The installing contractor shall ascertain that roof framing or existing building is capable of safely carrying the opera ting wei gh t of the equipmen t to be se t . " Section 2.That this resolution shall be effective immediately upon passage by the Board of City Commissioners of the City of Ocoee, Florida. Done and Resolved at the regular meeting of the Board of City Commissioners held on May 6, 1980. ATTEST: ~Q-~ -cT ERK 7#~ ~,,,.-.~ M~Y~ -