Background Summary:
As part of the CRA Beautification Program along the SR 50 corridor, $45,000 has been included for a lighted
decorative fountain in this year's capital budget. Staff has researched many fountains in the area and
consulted with various fabricators. Fountain Design Group has been the City's main provider for fountain
maintenance and is the industry leader for custom fountains of the size and type needed for this installation.
As a result of our contacts with this company, the City has been offered the opportunity to purchase a custom
15 HP fountain with added jets and lights that had been ordered and then cancelled by a large south Florida
developer. As a result, the City will receive a discount of approximately $4,000.00 for a fountain that matches
our needs perfectly. Due to the need to properly locate the unit near the middle of Lake Bennet, the quote
includes the cost of upgraded copper wire to efficiently power the fountain. The cost also includes the control
panel for the fountain and electrical hook -up. However, the CRA will incur an additional cost to have our own
electrician provide a meter pedestal and disconnect to service the unit.
Issue:
Should the City Commission authorize the City Manager to approve the purchase of a decorative fountain for
Lake Bennet?
Recommendations:
Staff respectfully recommends that the Mayor and City Commissioners authorize the City Manager to approve
the single source purchase of a Libra 1500 Floating Fountain for $41,092 per the attached quote from Fountain
Design Group.
Attachments:
Quote from Fountain Design Group
Financial Impact:
$41,092.00 (CRA Capital Improvement Budget)
Type of Item: (please mark with an "x")
Public Hearing For Clerk's Dept Use:
Ordinance First Reading Consent Agenda
Ordinance Second Reading Public Hearing
Resolution Regular Agenda
X Commission Approval
Discussion & Direction
Original Document/Contract Attached for Execution by City Clerk
Original Document/Contract Held by Department for Execution
Reviewed by City Attorney N/A
Reviewed by Finance Dept. aQif N/A
Reviewed by 0 N/A
2
CAS( AMUN)1 N ! \/ |U\
1:W\ STAIN AFNt, v;|(()i|`. IN( .
7628 N.W 6th AVENUE BOCA RATON, FL. 33487 PROPOSAL # 104
SERVICE CENTERS : ORLANDO AND TAMPA
PHONE: (800) 446-1537 FAX (561) 994-3944 Date: 5-Oct-12
To. City of Ocoee Ship To: Lake Bennett
150 N Lakeshore Drive Ocoee, Fl.
Ocoee, FL 34761
Attn: Russ Wagner
Phone. 407-905'3100
Fax,
EmaUV nwaqnerpcL
Equipment: Libra 1500. Floating Fountain
Scope of Work:
We will deliver and install n the ake area desgnated by the aeria provided, one custom Libra 1S0O 208v
three phase floating fountain with eight 500 watt lights and 600' of power cables The tota amperage Ioad on this unit s
70 amps ( we recommend a 100 amp service to be provided with a neutral and ground )
The ocaton wII require a 600 cable run from our panet ocation. This will require a#2/4 power cable and (2)#4/3
lighting cables We will supply the necessary power cables, set our control panel in the approximate location designated
by your map, hot wre from the servce being provided. and provide a conduit to the lake edge and suppty any permits
required for this installation,
Once installation is completed ourteckn/oan will start, test, and adjust the fountain and thsptay if necessary,
*The Gity of Ocoee is to provide power (208 volt 3 phase) service to an area within 5' of our panel location with a
service disconnect Our electrical contractor will handle providing power from that disconnect to our controls.
FOUNTAIN COST $24.250D0
ADDITIONAL POWER CABLES AND ELECTRICAL HOOK UP 16,842.08
TOTAL COST $41,092.00
ro/m°nto"e"no"nvmn/vvvn.
Respectfully Sumniued,
FOL/NTAIN DESIGN GROUP
Acceptance of Proposa The above pnce, specifira|ionv, and condttions are sabsfactory and are hereby accepted.
Fountain Design Group, Inc is authonzed to cornplete the work as specified
Signature: Date of Acceptarice:
CONDITIONS
All work .sm ..^ workmanlike ..o"%e. *Na*nm.°" ',rn spec. nu,:n",."m/°,voua costs will ue executed only up,' written approval from the client,
and will become o"^uo.um.al+"rp" from the pm,'o.,vvmncov/"m*^rst
7628 NW 6th Avenue
Boca Raton, FL 33487
A, Cascade Fountains Phone 561 94 3939
A Division of Fountain Design Group, Inc. Fax 561
ToII Free 800 - 446 - 1537
Fountain -ETL Listed
o 6' rotocast floatation unit with
four water tight compartments for
ballast with exclusive "Anti Drum-
ming" design
III LIBRA B RA'1 500 0 15 HP 208 volt *, three phase
submersible fountain pump and
A center stream of water reaching a height of 40' - 45' with 6 stainless steel sealed motor
heavy water aeration jets reaching 15' - 20' and angled out- 0 custom stainless steel pump
mounting harness
wards. Spray height and angled outer jets are fully adjustable.
The fountain is accented with 3000 watts of quartz lighting. 0 Custom stainless steel intake
screen
q
0 1 1/8" brass clear stream jet
0 2" brass aerating jets surrounding
center jet
0 1 volt submersible
founta in watt lights , tempered lenses,
, ma y, mounted on stainless steel brackets
it
� . 0 Adjustable flow valves
. . >, <:r. # -4 -- - , - `" X 0 250' length of b/4 submersible
electrical su I cable um
� � � � ' ' ,., +: PPY , p P
, , 0 250' length of 6/3 submersible
" ' electrical supply cable, lights
, � - ' 0 Bronze underwater junction box
,, ' , with cord seals
0 Control panel
# Control Panel -ETL Listed
NEMA 3R Enclosure
Y. ffi .'• ii - Lightning protection
? Motor starter
^,� Overload heater
GFI circuit breaker - pump
GFI circuit breaker -light
24 -hour time clock - pump
24 -hour time clock - lights
*Available in 230V (3) phase and 460V (3) phase
Co
* This specification is subject to change without notice.