HomeMy WebLinkAboutItem #05 Approval of Additional Funds for 2015 AmbulanceContact Name:
Contact Number:
I k ks � k Z/�
Ocoee
florida
AGENDA ITEM COVER SHEET
Meeting Date: August 4, 2015
Item # 9"
John Miller Fire Chief
407 - 905 -3140
Reviewed By
Department Director:
City Manager:
Subject: Approval of additional funds for 2015 Ambulance.
Background Summary:
The approved city budget includes the purchase of an Ambulance which is in need of an additional $48,915.00
for the purchase, as not to exceed amount of $140,000.00 that was originally approved for financing. The
additional amount will come from the following accounts 001 - 522 -00 -1200 - $32,915.00 and 001 - 522 -00 -2200 -
$16,000.00.The increase is due to the new Ambulance National Standards requirement.
Issue:
Request the Commission to approve the additional amount for purchase of the Ambulance.
Recommendations
Staff recommends the approval of the Commission to approve the additional amount of funds needed.
Attachments:
See attached quote
Financial Impact:
The additional funds would be coming from accounts 001 - 522 -00 -1200 - $32,915 and 001 - 522 -00 -2200 -
$16,000.00.
Type of Item: (please mark with an 'x')
Public Hearing
Ordinance First Reading
Ordinance Second Reading
Resolution
Commission Approval
Discussion & Direction
For Clerk's Dept Use:
Consent Agenda
Public Hearing
Regular Agenda
Original Document/Contract Attached for Execution by City Clerk
Original Document/Contract Held by Department for Execution
Reviewed by City Attorney N/A
Reviewed by Finance Dept. _ N/A
Reviewed by () N/A
2
. .
July 28, 2015
John Miller, Fire Chief
City of Ocoee Fire Department
563 A Bluford Ave.
Ocoee, FL 34761
RE: Proposal — 2016 Ambulances — Ford F450 Type 1
Wheeled Coach Industries is pleased to submit this proposal to the City of Ocoee Fire Department to
purchase off of the Florida Sheriffs Association Bid # 15 -11 -0116, Specification # 1, and with changes as
specified in the attached line sheet specifications, for the following ambulance proposals:
2016 Ford F450,4x2,XLT, 63L 189" WB chassis with Wheeled Coach Industries Firemedic 1170F custom
ambulance conversion $163,265.00, FOB Ocoee, FL. (each).
Stryker Power -LOAD ILO Ferno Stat -Trac (does not include cot) $25,650 (each).
Proposed unit(s) will be completed within 100 calendar days after receipt of chassis. Proposal price
includes FSA fees. Payment terms proposed are net due upon delivery.
We appreciate the opportunity to submit this proposal and compete for your valued business. Should
you have any questions, or wish to review this proposal in detail, please feel free to contact me at 407-
782 -4120.
Sincerely,
Bill McCorkle
District Sales Manager, Wheeled Coach Industries
2737 N Forsyth Road
Winter Park, FL 32792
407 - 782 -4120 (cell)
800 - 513 -8198 (fax)
Bil I.mccorkle(@wheeledcoach.com
Cop-poi-ale Office: 2737 North Forsyth Road, Winter Park, FL 32792 ! Post Office Box 677339, Orlando, FL 32867 -7339
800- 342 -0720 • (407) 677 -7777 • Far: 407 -679 -1337 • htip:! /www.whccicdcoach.com
)z Wheeled
andf ovrwr*oHr QUOTATION
Ocoee Fire Department Wheeled Coach Industries, Inc
John Miller Bill McCorkle
Quote No: 15011 -0001
T1 -170: 210160 STD Model: Type 1 Ford - 170 "Module - #1170F
T1 -170: 0990029STL Ford, F- 450,189 "WB,4x2, XLT,170 ", #1170F
T1 - 170: 200011 STD Type 1 Ford - 170" Module - #1170F
V v vft.
_= Ford, F- 450,189 "WB,4x2, XLT,170 ", #1170F - 620.021 03/06/15== 1
CHASSIS: 1
00 -10 -3332 Ford 2016 F- 450,4x2,XLT, 6.7L, 17011, #1170F 2015 -5 1
189" wheelbase
Autothrottle OEM Ford
Alternator OEM Ford
Mirrors, OEM, Heated /Remote
Cab seats OEM Captains chairs(no armrests)
Note Liquid Spring Suspension System ILOS
CAB TO MODULE MOUNTING: 1
10 -10 -1001 Bellows, Passthru, Unigrip, F1 2008 +, Std 1
With Aluminum cab insert.
CHASSIS ADD -ONS: 1
1A -10 -0100 Lettering /Graphics, By Outside Vendor 1
(if rear chevron will be installed, add comment in paint area
of work order to delete any paint belts on rear of module!!!)
Location:
# of Days:
1A -10 -3700 Roof Reinforcement, Type 1 Ford I 1
Aluminum strips to reinforce cab roof
SUSPENSION: 1
1 F -30 -7540 Rear Suspension - Liquid Spring- F450, 4x2 ILOS 1
CHASSIS ADD ONS, MISC 1
2F -70 -4300 Seats, Cab, Reupholster,Gunmtl Gray,O/Vendor 1
Katzkin by D &B - Match FDNY color
2F -71 -7103 Cab Flooring, Black Rubber, 2009 +, F350/450, OEM 1
HEATING /AIR CONDITIONING: 1
51-1-12 -5000 Hoses, Heater, No Max, to Rear, STD 1
51-1-70 -0107 Heat/AC, F1, 2011 +, Combo, w /Coolbar 1
(new code)
with thermostat in action area.
12vdc External Condenser, in Coolbar mounted on front
of module. Painted. Specify paint code
Note: pick warning lights separately !!
WO #:
60 -22 -1030 Battery Sw, 5min Timer, F1, Fig 5B, Batt under Hood
Activated thru OEM ignition switch timer function upon
ignition "off'.
Momentary rocker switch, on driver's side of cab console,
to function as timer shutoff and also reactivate timer.
(2) OEM batteries under hood
ONLY Module power is turned on /off.
Chassis power is NOT turned off.
CONSOLES:
7U -10 -0602 Console, Center, Pass -thru, Mica Finish, F1, 2008+
Deleted
7U -10 -7000 Console, A/A, Wood, Angled
7U- 10 -SR01 Console, Center, Passthru, Aluminum, Scorpian coating, ILOS
(SO -CC- 331180)
Cab console to be formed aluminum construction, contoured, and painted with Scorpian black
coating. To include switch panel /siren control area, blank area for radio mounting, and (2) cup
holders and map storage. Design an area at the front of the console to accommodate any 12v
and USB power requirements.
Provide Eng design drawings of console and panels for customer approval.
** **CHANGE* * ** Remove cupholder inserts and blank panel forward of cupholders, punch new
larger panel with cupholders forward and leave panel blank over current cupholder holes. See
photo.
BULKHEAD CABINET:
TF -50 -1000 Bulkhead, Unigrip, Pass Thru, 1 53/170x67, Ford
WHEELCOVERS:
X5 -10 -3901 Covers,Wheel, Phoenix, F450,4X2 /4x4,1153/1170
with Air Max Valve Extenders, std
Requires stainless steel wheelwell covers attached
to squad bench and basewall cabts that will
protrude up to 1.5" into aisleway on each side.
Install anti -slip decal with Wheeled Coach logo
on curbside and rear stainless steel thresholds, STD
35 -10 -0320 Module Skins, 0.125 inch
35 -10 -0502 Headroom, 72 in. Type 1 - 170" module, #1170F/D
35 -11 -0200 Drop Skirt, 4 inches forward of rear wheels, Both sides
37 -00 -0350 Coating, Scorpion X02, Per Compt, (1), Std
light gray
37 -00 -0360 Coating, Scorpion, Rear Bumper Supports
37 -00 -0500 Compartments, Std, Floor 3" Drop Down from Door Opening
compts B1,B2,D,& E are STD drop down floor
37 -00 -0600 Compartments, Sweepout
- Compartments "A" & "F" are standard sweep out
1
1
1
1
1
1
1
2
_= Type 1 Ford - 170" Module - #1170F - 620.021 03/05/15 =_
35 -05 -0055
Type 1 - 170" Module - Standard Model Series
35 -05 -0060
Type 1 - 170" Module General Body Construction Spec
35 -05 -0065
Type 1 - 170" Module Vehicle Body Structure Spec
35 -05 -2000
INTERIOR CABINETS - Duralite Construction, Wood
MODULE BODIES:
35 -10 -0068
Aisle Space, 50 inches, STD, Type 1, Std Model Only
(49 -50" actual)
Requires stainless steel wheelwell covers attached
to squad bench and basewall cabts that will
protrude up to 1.5" into aisleway on each side.
Install anti -slip decal with Wheeled Coach logo
on curbside and rear stainless steel thresholds, STD
35 -10 -0320 Module Skins, 0.125 inch
35 -10 -0502 Headroom, 72 in. Type 1 - 170" module, #1170F/D
35 -11 -0200 Drop Skirt, 4 inches forward of rear wheels, Both sides
37 -00 -0350 Coating, Scorpion X02, Per Compt, (1), Std
light gray
37 -00 -0360 Coating, Scorpion, Rear Bumper Supports
37 -00 -0500 Compartments, Std, Floor 3" Drop Down from Door Opening
compts B1,B2,D,& E are STD drop down floor
37 -00 -0600 Compartments, Sweepout
- Compartments "A" & "F" are standard sweep out
1
1
1
1
1
1
1
2
WO #:
Duraseam Doors, with Hidden Jambs
- Magnetic door switches, Standard
39 -AO -0177
A, Compt,Single Door, Pureair, 170" Module, 72" HR, #1170F/D
39 -B1 -0155
B1, Compt, Std, 170" Module, 72" HR, #1170F/D
39 -62 -0177
B2, Compt, Std, 170" Module, 72 "H.R, #1170F/D
39 -DO -0355
D, Compt, 3/4, 170" Module, 72" H.R, #1170F/D
1
With Double Doors
39 -EO -0105 E, Compt, Std, 170" Module, #1170F/D
With Double Doors
39 -FO -0305 F, Compt, Std, Full Height, 170" Module, 72" H.R, #1170F/D
39 -FO -0600 With Dogleg for Stairchair in Compt "F"
FUEL FILL HOUSING:
3A -10 -1000 Housing, Fuel Fill, Cast, F1 /C1 /D1 /M2
EXTERIOR DIVIDERS:
3F -10 -1101 Divider, Vertical, B2, 3/16" Thick, Recessed Adj Track,Std Model only
(divider to be full depth if a shelf is requested)
compt "B2 ", centered.
SHELF- COMPARTMENT "A " /RF CABINET:
3F -20 -1000 Shelf, Adjustable,(1), RF Cabt Custom
(1) RF Compt "A " /cabt "E1" area, centered.
3F -20 -1500 Shelf, Additional, Adjustable, (1), RF Cab Custom
RF Compt "A " /cabt "E2" area, centered.
(change to cabt "E1" for combo unit cabt)
3F -30 -1000 Shelf, Custom, Adj, Cmpt "B ", (1)
SHELF- COMPARTMENT "D ":
3F-40 -3001 Shelf, Custom, Adj, Cmpt "D ", (1), Std Model only
at bottom of cabt "H" inside /outside access opening.
SHELF- COMPARTMENT "E ":
3F -50 -0100 Shelf, Fixed, Cmpt E, for Electrical storage, w/ Divider
Area to right of divider will be used for bio -waste in A/A if selected. If no bio - waste, area to be
left open for addt'I customer storage.
SHELF- COMPARTMENT "F ":
317-60 -6000 Shelf, Custom, Adj, Cmpt "F ", (1)
(2) Compt A
(1) Compt D
(1) Compt B
(1) Compt F
(1) Compt E
COMPARTMENT / SHELF, MISC:
3F -70 -1200 Upgrade,Shelf /Div to 3/16 ",W /1" Lips, ILOS
Location:
3F -70 -1710 Reinforcement, Compartment Wall, For SCBA Bracket
Compt D wall #2 approximately 6" above floor.
1
6
WINDOWS:
1
3P -10 -5201
Window, Upper, CS/Slider, Rr/Fixed, Priv Tint,PAN,Std Model only
1
MODULE ENTRY DOOR HANDLES:
1
3U -30 -8000
Handles, Patient Entry, Trimark Black/Chrome "SafePass" STD
1
EXTERIOR COMPT DOOR HANDLES:
1
3U -40 -0510
Handle, Module Compt, Trimark, Black/Chrome, STD
6
3U -40 -0514
Latch, Paddle, Trimark, For Trailing Door
1
compts "D" Wor "E"
WO #:
3U -60 -0100 ELECTRIC DOOR LOCK PACKAGE OPTIONS: Click to a
3U -60 -0500 Circuit, OEM Door Lock to activate Mod Doors(not Dodge)
3U -60 -1390 Door Locks,Electric, Trimark, (1)DOOR, Entry Door
Module entry doors.
3U -60 -1400 Door Locks,Electric, Trimark, (1)DOOR, Compt Door
All module compts(except battery compt) .
(unless other specified)
ELECTRICAL LOCKS SWITCHING:
3U -60 -1500 Switch, Momentary Rocker,Activate Elect Door Locks
(Note: will not lock/unlock Dodge cab doors)
Installed on C/S wall at head of S /B.
(unless otherwise specified)
3U -60 -1900 Switch, Stealth, Cab Doors (not Dodge)
In grille on passenger's side.
3U -60 -3000 Relay Control Circuit, Electric Locks
(Use dropdown menu to pick #3U -60 -2950 if keyless entry is required)
3U -60 -5200 Circuit, OEM Door Lock to activate Mod Doors(not Dodge)
DOOR HOLD OPENS:
40 -10 -1611 Hold Opens,Rr Doors, Cast, Grabber (2), 5.5 ", Std Model only
- Installed so doors will open as wide as possible
- Mount at top of doors.
- (relocate to bottom is backup camera is selected)
40 -10 -7200 Hold Open, Gas Strut, Ext Compt, 301b, Std
40 -10 -7205 Hold Open, Gas Strut, RF Compt, 301b, Std
DOOR PANELS:
45 -10 -4505 Panels, Entry, Durasafe, Stainless Steel, w/ Chevrons, STD
- Durasafe Design
- Aluminum Center Panels covered: white /red reflective tape
FENDER FLARES:
4A -10 -1001 Flare, Fender, Rear, Black Rubber, Std Model only
BUMPERS:
4F -10 -1101 Bumper,Rear,w/ Skids & Flip Up,F1 /C1,w /LED DOT Its,Std Model
w/ Gator Grip on flip up step.
RUNNING BOARDS:
4K -10 -2106 Running Boards, Standard,F450, w/ Gator Grip, #1153F/1170F
SKIRTRAILS
4U -10 -9210 Skirtrails, Extruded Rubberw /Refl Tape, 170 -175" Module
4U -10 -9500 Tape, Reflective, White, For Extruded Rubber Skirtrails
STONE GUARDS (FRONT):
4U -11 -2000 Stone Guard, Front, Dia Plate, 13.38"
KICKPLATES (w /STD. REAR STONEGUARDS):
50 -10 -2105 Kickplate, W /Recess, No Light Holes,Duraseam
55 -10 -3000 Holder, License Plate, Cast, C30002, STD
- in rear kick plate, centered
SILL PROTECTORS
55 -30 -4001 Sill Protectors, Stainless, All Compts, Std Model only
MODULE STEPWELL:
55 -90 -4000 Step, Electric, Kwikee Products
Constant hot, locate under C/S access door.
55 -90 -6000 Stepwell, Double Step, ILOS, Type 1
4
1
2
0
6
1
1
1
1
1
1
1
1
1
1
1
1
1
VVWM
5A -10 -1001 Mud Flaps, Rear, W /Logo, Std Model only
PAINT /BELTS:
5F -10 -3200 Paint, Entire Unit, 20% Upch
Color:
Sikkens paint code #
Send sprayout for approval to:
Do Not paint unit until sprayout is approved !!!!
5F -10 -4801 Paint, Belt, None, Std Model only
Cab & Module, all white, std.
DECAL PACKAGES INSTALLED:
5P -10 -5001 Roof Star, White Border, Installed, Std Model Only
ELECTRICAL SYSTEM: Circuitboard
61- 23 -SR01 Newmar StartGuard DC Power Conditioner
(SO -COND- 331034) #213254R -1 Newmar StartGuard Part #NS -12 -20
Mount in CB area
Input power constant hot, 12 gauge wire
Route 20 amp positive and negative output leads to CC & tag: NEWMAR STARTGUARD
12 gauge wire
Customer will connect their Panasonic Tough book to these leads
COAX CABLES /ANTENNAS:
65 -30 -1000 Coax Cable, RG58 /U, (1) Each, Standard, Terminate:
- From module roof port number #3 to behind passenger seat
standard - with 6' pigtails
65 -30 -6500 Base- Antenna, Motorola Mount, W /Coax
Mod roof port 1 to cab console
Mod roof port 2 to cab console
Mod roof port 3 to cab console
12VDC POWER SOURCES & OUTLETS:
6A- 22 -200E Outlet, Cigar Lighter, STD, (2), A/A
- on standard 20 -amp ignition hot circuit. ( "elect batt sw ")
6A -22 -2500 Outlet, Cigar Lighter, IATS, (1)
Constant hot.
(1) RF cabt wall #2 up high approx centered between
wall #1 and 110 VAC outlet.
(2)Front of CC, pass side /front, side by side, down low.
(1) Behind atten seat, down low on bulkhead cabinet
6A -22 -5100 Outlet, Dual USB Port, 5VDC, 2.1Amp output, Standard
Located on the passenger side of the center console, per Electrical Engineering
6A -22 -5150 Outlet, Dual USB Port, 5VDC, 2.1Amp output, IATS
Location console top next to std
POWER SOURCE, 12 VDC
6A -23 -0910 Power Source, 12VDC, 20A, Ignition /Shoreline Hot
20amp 12 volt DC circuit ran to two locations, (1) pre -wire coil and tagged in action area and (1)
pre -wire coil and tagged behind driver's seat.
6A -23 -1201 Power Source, 12 VDC,15 Amp ( + -), Std Model only
- Ignition hot, terminating in cab console
- with 6 foot tails (hot and ground).
3
WO #:
Hower Source, 12 VL)U,;3U Amp ( + -)
Ign hot - center console - for buss bar
6A -23 -3001 Power Source,12 VDC,30 Amp ( + -), Std Model only
- Constant Hot, to terminate center console
- with 6 foot tails (hot and ground).
6A -23 -3800 Power Source,12 VDC,40 Amp ( + -)
Prewire for Stryker Power -Load Powered by: Ignition /Shoreline Hot
ELECTRICAL ACCESSORIES
6E -10 -4450 Camera, (2), Backup, Safety Vision, w /Color LCD Monitor
Mount (1) camera exterior on rear of module, off center
toward driver's side.(if there's a center light)
Mount (1) camera interior above rear entry doors, off center
toward driver's side.
Mount monitor: per photo
SHORELINE INLETS:
6F -90 -4107 Super Auto Eject,20 amp, ILOS, Yellow, Std Model Only
- with yellow cover; mounted above compartment "E"
110 VAC OUTLETS:
6K -40 -1000 Outlet, 110 VAC, Duplex, (2), STD
- (1) outlet in action area
- (1) outlet in the RF Cabinet "E1 ", wall #2, upper right.
(change to cabt "E2" for Pureair 1 cabt)
6K -40 -2000 Outlet, 110 VAC, Duplex, IATS
- telemetry area, wall #2.
6U -10 -5000 Battery Charger, Conditioner, Progressive Dynamics, PD9130
Charger /Conditioner mounted in Comp "E"
INVERTERS:
7F -10 -0610 Indicator, Vanner Charger, Remote, #LSCR, LED
Located:
7F -10 -9000 Inverter /Charger, Vanner 20- 1050CUL -DC
- Mounted In EVS seat base
GAUGES /METERS:
DO -10 -1200 Meter, Analog, Volts, F1
DO -10 -6500 Alarm, Low Voltage, Audio/Visual
Light in cab console and Buzzer in cab.
SEQUENCING /LOAD MANAGEMENT:
DA -10 -4000 Switch, Emergency Master,Non Seq
SIREN SPEAKERS:
DF -10 -1241 Siren Speakers, Cast SAD/P3806-1 1 FSD-1, F1, 2011 +, Std
Thru Front Bumper
SIRENS:
DK -10 -1400 Siren, Whelen, WS- 295- SLSA1, Standard
DP -10 -91 SR Airhorn, Buell, 5440 comp, 10 & 12 inch horns, w /Box
(SO -AH- 331034)
Compressor located on frame rail in a small compressor
box next to air horn air tank.
Use light or medium locktite on airhorn trumpet threads.
Airhorns to be as recessed as possible!!!
ition hot, std.
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
VVUIf:
DP -11 -1000 Switch, Siren /Horn Thru Horn Ring
DP -11 -2500 Switches, Foot (2),(1) DrSide,(1) Pass
SWITCHES ADDITIONAL:
DU -10 -9000 Switch, Emergency Master
AUDIBLE ALARMS:
FO -11 -3501 Alarm, Back -Up, Auto Reset, Std Model only
VEHICLE EXTERIOR LIGHTING
FF -10 -6000 Cab Headliner Removal Fee, MAV
for lightbar installation
FU- 35 -SR01 (GTT) #794H Opti -Com with mount bracket.
(SO -OPTI- 331034) SR #SR# 213348 LED High Priority
Front of module below 9 Series warning light, driver's side.
SWITCHED: Sep switch, Primary only and in gear
1
1
1
1
1
1
1
1
WHELEN SUPER LED 9L FLASHING LIGHTS T1,3,9: 1
FU -40 -0107 Light, 9L, Super LED, Whelen, Red,Clear Lens,IATS, 90RR5FCR 4
In the following pattern(inner) - R,C,R,C,R,C,R
(2)On front 1 each side of center clear light -cool bar (Prim only)
(2)On rear to show through rear windows (Prim /Secon)
Modu Flash, internal flasher
FU -40 -0115 Light, 9L, Super LED, Whelen, Clear, IATS, 90CC5FCR
(2)On front in the following pattern (outer) (Cool bar) R,C,R,C,R,C,R
Primary only, Modu Flash, internal flasher
2
WHELEN SUPER LED 9L STEADY BURN LIGHTS T1,3,9: 1
FU -40 -0505 Light, 9L, Super LED, Whelen, Red,Clear Lens,ILOS, 90RR5SCR 8
(2) On front, upper outer corners
(2) Each side, standard locations
(2) On rear, upper outer corners
Connect to Whelen flasher /Prim /Secon
FU-40 -0510 Light, 9L, Super LED, Whelen,Amber,Clear Lens,ILOS, 90AA5SCR
Center rear
Connect to Whelen flasher /Prim /Secon
FU-40 -0514 Light, 9L, Super LED, Whelen, Clear, ILOS, 90CC5SCR
Center front (Cool bar)
Connect to Whelen flasher /Primary only
5 SERIES(TIR6) SPLIT LED LIGHTS:
H4- 05 -57SR Light, 5L TIR6, Whelen, Clear, Clear 50CO2ZCR, IATS
(SO -LT- 331034) Same as (SO -LT- 301070) AS95777
(1)Upper grille passenger
(1)Lower grille driver's side
Red grille lights to flash X pattern with clear grill lights
Wired through Whelen flasher - Primary only
5 SERIES(LIN6) NON -SPLIT LED LIGHTS: 1
H4 -06 -5713 Light, 5L LIN6, Whelen, Red, Clear Lens,50R02ZCR, ILOS 2
(new code)
Specify location, switching and lighthead flash pattern.
WHELEN 5E FLANGES /HOUSINGS: 1
H4 -10 -0045 Housing, 5L Series, #5LSMAC, (1) 8
114 -10 -0045 Housing, 5L Series, #5LSMAC, (1) 1
WO #:
INTERSECTION LIGHTS, FORD & Chevy Type 1, WHELEN 1
CORNER CAP LIGHTS 1
HF -11 -6049 Corner Cap Lts,Multi- LED,(2)Amber(2)Red w /Flashers,Std Model 1
- High intensity flashers; thru separate switch
CLEARANCE LIGHTS:
HF -12 -9100 Light, Clearance, Amber LED, ILOS
HF -12 -9601 Light, Clearance, Red LED, Std Model only
- On rear as clearance lights.
:3
1
3
3
SCENE AND LOAD LIGHTS 1
HK- 20 -110M Light, LED, Whelen, Clear, #9SCOENZR, 24 LED, [LOS, (1) W/ Chrome Flange 4
(new code)
(2) each side as scene lights
HK- 20 -130M Light, LED, Whelen, Clear, #9SCOENZR, 24 LED, [LOS, (1) W/ Chrome Flange 2
(new code)
(2) on rear as load lights
HK -20 -7100 Scene Lights, C /S, Activated W /C /S Door 1
HK -20 -7400 Rear Scene Lts Activate W /Rev Gear. 1
Rear load lights wired to reverse standard.
FLASH PATTERN WARNING LIGHTS: 1
HU -11 -2500 Brake Override Circuit 1
(Must use IATS Stop /tail lights with this option)
WARNING LIGHT FLASHERS 1
HU -24 -7500 Flasher, Whelen AFM -560, [LOS 1
Set flash pattern to Comet Flash unless
otherwise specified.
HARNESS LAYOUT: 1
J5 -12 -1000 Halogen, " E " Spec, Whelen 1
STOP/TURN /TAIL LIGHTS: 1
JA -10 -1200 Light, License Tag, (2), Trucklite #15205 LED, [LOS 1
JA- 10 -SR02 TecNiq #E96- WSOO -1 LED Docking Lights, Pair 1
SR #213218F
(1) mounted on each side of module just to the FRONT of the
rear wheels. Lights will activate in reverse.
JA -11 -0099 No Flanges or housings, Standard 1
JA -13 -8084 Tailight Pkg, Whelen, M6 LED Stop/Tail,Turn Arrow & Max Intensity Backup 1
- Brake- Alert Flash before the steady Burn
- Turn Arrow — sequential arrow
MODULE OVERHEAD HEADLINER: 1
JK -10 -5516 Headliner, Flat, Expanded PVC, 160 "+ MAV/Type 1, with (8) HVAC ducts 1
12VDC INTERIOR LIGHTING: 1
JP -10 -0611 Lights, Dome, LED, Whelen,White Fing, (4) S /S, (3) C /S, ILOS 1
NOTE: NO VISABLE FASTENERS OR HOLES.
JP -10 -0621 Light, Dome, LED, Whelen,White Fing,(1) IATS 1
Location ?
NOTE: NO VISABLE FASTENERS OR HOLES.
WO #:
JP -10 -7005 Light, Stepwell, Trucklite, 2in, Std
JP -10 -8020 Light, Kinequip #621224W, LED, In A/A ILOS
LIGHTS & MISCELLANEOUS:
JR -50 -1000 Spotlight, Handheld, 100,000 CP
JR -50 -2880 Lighting, Compt, LED Hi -Brite Flex, ILOS
both vertical edges near door jambs, compts "A ", "B1
"132 ", "D ", "E ", & "F ". Retain 2" 02 light.
JR -60 -2003 Timer, Momentary Sw,15 Minute, Constant Hot, Std Model only
(must have ECX timed battery switch with this option)
Mount switch on C/S wall at the head of the squad bench
in the standard location. Switch to allow activation and
also deactivation. Wire to fluorescent lights in liner.
JR -70 -0005 Light, in Circuit Board Area, for Electrical Troubleshooting
- with integral switch; wired constant hot.
CLOCKS:
LO -10 -1000 Clock, 4in , Battery Powered
LOCATION:
INTERCOMS:
LF- 10 -SR00 Firecom 5100D Intercom System for Single Radio Interface
(SO -FC- 331034) SR #213254R -1 BOM per Elec Eng see SR
5100D Intercom unit to mount in lower panel of cab console power from ignition hot Buss Bar in
cab console
Allow space for two -way radio speaker to be installed by radio installer
(1) HM -10 to mount in cab ceiling, toward rear, off center toward driver's side
(1) HM -10 to mount in cab ceiling, toward rear, off center toward passenger's side
(3) Hanger hooks ( #520 - 0676 -000)
(2) Dual Muff Headsets, FH -51 transmit
6C flat cable ( #108 - 0102 -00) Intercom interface cable in cab ceiling
Outside vendor to install radios and interface with Firecom system installed by W/C
LF- 10 -SR05 Cable, Interface, Firecom, for XTL5000 Motorola Remote
(SO -COM1- 331034) SR #213254R -1
Connect to Firecom 5100D in CC FireCom #110- 5136 -30
terminate in CC
SUCTION PUMPS:
LP -10 -0500 Suction Pump, Standard
INSULATION:
LU -10 -1000 Insulation, Fiberglass, Unfaced
LU -10 -3001 Insulation, Severe Weather Package
one inch block foam in modular walls and roof covered with reflective insulation.
Under Floor to be Spray Foam insulated after the production assembly process is complete by
24/7.
All edges of reflective insulation on walls and ceiling must be taped, std.
GRABRAIL(S) /GRABHANDLES:
NO -10 -9101 Grabrail, Overhead, 117 ",Handicap Style,Yellow,Std Model Only
WO #:
Yellow Powder Coat Finish
NO -10 -9703 Hand rai Is, (3),Custom "L" Shape, 1 ",Yellow, Entry Drs,Std Model
- Yellow Powder Coat Finish Stainless Steel Grab Handles
02 CYLINDER RACKS:
NA -10 -2500 Rack, Cylinder, Ziamatic, "M ", QRM -2
02 SYSTEMS COMPLETE:
NF -50 -1001 02 Sys,LF,(2)O2 /(1)Vac Port A/A,(1)O2 C /S, Std Model only
Ohio style
(2) oxygen outlets in action area
(1) vacuum port in action area
(1) oxygen outlet curbside wall at head of squad bench
02 SYSTEM PARTS:
PO -59 -7500 Regulator, Oxygen Cylinder, Preset 50PSI, Installed
(new code)
SUCTION CONTAINERS:
PA -10 -7001 Regulator /Holder, SSCOR 22000, Std Model only
COT MOUNTS:
PF -35 -3800 Cot Mount,Stat Track,Single Pos,35A/93ES,LT
Length of track is 103 ".
single position.
Location:
10
IV HOOKS: 1
PP -20 -8500 IV Hook, Cast, Fold Down Recessed, [LOS 2
KICK PLATES STAINLESS STEEL, ON CABINETS: 1
PU -10 -1000 Kickplate, Brushed S /S, Face Of Squad Bench 1
PU -10 -2000 Kickplate, Brushed S /S, On Face of Basewall 1
MISC. INSTALLED HARDWARE /EQUIPMENT: 1
R5 -10 -8000 Wrench, Oxygen, Tethered, Mods 1
in oxygen compt.
R5- 10 -SR01 Bracket for Lifepak 12, Ferno #M200
(SO -M200- 331034) Ref (SO -M200- 299031) SR #213254R -1
Extended action area See ref picture on the server for mounting location DSC04140.JPG.
R5 -11 -2010 Net, Squad Saver, at Head of Squad Bench, 2" Straps, Black
attached to floor at head of squad bench, CS wall and overhead liner with removable latches.
R5- 11 -SR02 Bracket, Zico, SCBA, Angled, for Scott 4500 PSI Cylinder
(SO- BRACK- 311072) SR# 214894F
(1) Zico Model SC- 50- H -5 -SF bracket with Zico Model CRS strap on Zico Model ABS angle
bracket in compartment D on wall #1. Height approximately 6" above floor. Make certain the
SCBA is angled toward the outside of the compartment.
(1) Zico Model SC- 50- H -5 -SF bracket with Zico Model CRS strap on Zico Model ABS angle
bracket in compartment D on wall #3. Height approximately 6" above floor. Make certain the
SCBA is angled toward the outside of the compartment.
DRI- DECK/TURTLETI LE:
RA -10 -2000 Dri Deck, Black, All compt. Floors and Shelves
HOLDER, CYLINDER:
RF -11 -5000 Holder, Cylinder, Single Floor, Ferno #521, Installed
TBD
WO #:
RK -13 -3500
Seat Belt, Across Compt Opening
RP -10 -1000
Reflector, 3 In, Red, Screw -On, (1)
T5 -25 -0500
MODULE INTERIOR
RU -05 -0000
Interior Cabinets - Duralite Construction, Wood
TK -10 -5010
MICA COLOR:
RU -10 -3010
Mica, Gray Pampas #4168 -01, High Gloss
TN -20 -1001
SUB FLOORING:
RZ -99 -0300
Floor, Interior, Non Wood, Type 1, ILOS
FLOORING:
TO -11 -8201
Flooring, Lonplate II,Gunpowder Grey #424TX, Std Model only
SEAMLESS ATTENDANT SEATS:
T5 -10 -5111
Seat, Attendant, EVS, Child,Gunmetal #1880CB, Std Model only
Vacuum formed EVS1880CB w/ 3 point seatbelt.
Integrated child safety seat.
Mounted metal box base.
T5 -11 -4505
Door, Diamond Plate, EVS Seat Base, w /Louvers
SEAMLESS UPHOLSTERY:
T5 -25 -0500
Uph, Smless, Gunmetal,No Bio,No Post & Wheel
02 DOOR:
TK -10 -5010
Lexan Flaps, Hinged Left Side, Fixed Right Side, Std
GLOVE HOLDERS:
TN -20 -1001
Cabinet, Glove Box Holder,(3),Above C/S door, Std Model only
(narrows cabt "E1" on Pureair 1 w /low headroom)
RIGHT FRONT CABINET:
TLIA 7 -1560 Cabinet, Right Front, 2001 Pureair, Modified VA Style, 72" H
E1 inside /outside access. Combo HVAC
RF CABINET DOORS W/2001 PUREAIR A/C
TU -21 -7350 Doors,Modified VA Style, E1 & E2, 2001
E -1 double doors.
HARDWARE,LATCHES AND LOCKS:
VO -10 -0500 Handle, C, Pull, Installed,(1) Ea,STD
-RF Cabinet(s)
VO -10 -2000 Latch, Plunger Roller, Installed
-RF Cabinet(s)
VO -11 -6200 Latch,Lever,No Key,For EVS Door only
VO -13 -9001 Latch, Lever, No Key, Installed, STD, 2001 Style RF Cabt
One (1) RF Cabinet Door E -1 Leading Door
SQUAD BENCH:
V5 -20 -8300 Squadbench,(2)D Cyl Storage,W /Biowaste, 165" -170" only
Eng note Ref Rev 04 unit # 311071 KENDALL SHARPS- A -GATOR SHARPS CONTAINER RED
1 GALLON 4.8in H x 7.25inD x 8.5inW 32 /CS
LID 170 INCH BOX:
V5 -64 -1501 Lid, Squad Bench, Single W /Bio- Waste, 170 ", Std Model only
HARDWARE:
V5 -80 -1005 Handle, Trimark, Squad Bench, STD
V5 -82 -2500 Strut, Gas, 60 LB, Installed, ILOS, Mods
CURBSIDE SPLINT CABINET 160 -170 inch Module
VA -40 -2950 Curbside Splint Cabt, None
CURBSIDE REAR CABINET:
VF -20 -4700 Cabinet, Curbside Rear, Standard, 170 ",72 "HR
CABINET H, BASEWALL 170 ", T11T3
VH -H2 -0400 H, Cabinet, Deleted
11
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
4
1
1
1
1
1
1
1
1
1
1
1
1
1
VH -12 -0400 I, Cabinet, Deleted
WO #:
CABINET M, BASEWALL 160" & 170 ", T1/T9
VH -M2 -0300 M, Cabinet, deleted
CABINET O, BASEWALL 160 - 170 ", T1/T3
VH -01 -0100 O, Cabinet, full height, std
CABINET CPR, BASEWALL, 149 " - 170 ", T1 & T3
VH -QO -0101 CPR, side seat, Std Model only
CABINET J, STREETSIDE UPPER 170 ", T1 /T3
VI -J2 -0300 J, Cabinet, 72" H.R.
CABINET K, STREETSIDE UPPER 160 - 170 ", T1/T3
VI -K1 -0205 K, Cabinet, 2/3 depth, 72" H.R.
CABINET L, STREETSIDE UPPER 160- 170 ", T1/T3
VI -L1 -0255 L, Cabinet, L1, L2, Combine 2 Equal Cab, 72" H.R., Full F
BASEWALL DOORS:
VK -16 -5000 Cab O, Gray Lexan Slider
VK -17 -6200 Restocking Feature, (1) cabinet, (2) Gas Strut, 20lbs,ILOS
With 2 Perko elbow latches for closure.
installed on the following cabinets:
J, K, L1, L2
TELEMETRY AREA WORK SURFACE
VP -10 -5461 Telemetry Tray, Poured, Gray
ACTION AREA WORK SURFACE
VP -10 -5918 A/A Tray, 160 " - 170 ",W /0 Bio,Poured, Gray, MAV/1 170F/1 170D
(new code)
It will be necessary for the right end of poured tray to
be cut off. There will be no raised ledge on right end
of poured tray. Caulk/sealant to be applied.
ACTION AREA 165/170 INCH BOX:
VP -15 -7005 Cab,A/A,Without Biowaste, 170" Type 1
(new code)
VU -14 -4000
Shelf, Interior, Adj, in Cabinet:
VU -14 -4000
Shelf, Interior, Adj, in Cabinet:
VU -15 -2000
Cab "J" Gray Lexan Slider
VU -15 -4000
Cab "K" Gray Lexan Slider
VU -15 -8000
Cab "L1" Gray Lexan Slider
VU -16 -3000
Cab "12" Gray Lexan Slider
SHIP LOOSE ITEMS:
YY -00 -0001 Bracket, Spare Tire Mounting, Ship Loose
YY -10 -6400 Ship Loose, W.C. Standard Items
YY -13 -3000 Spare Tire, OEM only, Ship Loose
WARRANTIES
ZZ -10 -0101
Warranty, Conversion, 12 Month
ZZ -10 -0201
Warranty, Paint, 60 month Prorated, Standard
ZZ -10 -0300
Warranty, Structural, 15 Years, Std., Mods
ZZ -10 -0601
Warranty, Limited Electrical
ZZ -10 -0701
Warranty, Cabinet Construction
ZZ -ZZ -0200
End Of Order
12
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
REVISIONS AND CHANGES TO THE FEDERAL KKK - 1822 -F SPECIFICATIONS
Over the past several months we have keptyou informed on the pending changes to the
KKK- A- 1822FAmbulance Specifications. We expect this newly updated document will
be aublished and effective on July 1. 2015 as Change Notice 8. Below is what our
manufacturers are stating need to be addressed at the time ofpurchase. Illinois'
position on the change is also attached.
NOTES FROM OUR MANUFACTURERS
We were previously notified that there would be three (3) major changes to include SAE J3026, SAE
13027 and SAE J3043. Of those additions we are now informed that SAE J3043 — Ambulance Equipment
Mount Device or Systems will not be included in the July 1, 2015 publication as initially announced.
Therefore, effective July 1, 2015 the following changes are being implemented. There are several
OPTIONS that will be credited to the standards change.
Changes in STANDARD offerings to comply with KKK- A -1822F — Change Notice 8, paragraphs
3.11.4, 3.11.4.1 and 3.11.4.2, SAE J3026 — Ambulance Patient Compartment Seating Integrity
and Occupant Restraint as published July 1, 2015. This addition will make STANDARD the
following items:
A. Squad Bench seating positions to become two (2) positions with 6 — Point Seatbelts.
B. CPR Side Option if selected will include a 6 — Point Seatbelt.
C. Primary Attendant seat at the head of the cot will have the current 3 — Point Seatbelt
2. Changes in STANDARD offerings to comply with KKK- A -1822F —Change Notice 8, paragraph
3.11.6, SAE J3027 — Ambulance Litter Integrity, Retention and Patient Restraint as published
July 1, 2015. This addition will make STANDARD the following item:
A. Modular units — Ferno Stat Trac, model 185MT — 96" length — STANDARD — CN8 Compliant
A1— Option to Ferno Stat Trac, model 185LT —102" length — CN8 Compliant
A2 — Option to Stryker Power Load, Model 6390 - no wheel guides — CN8 Compliant
A3 — Option to Stryker Power Load, Model 6390 - with wheel guides — CN8 Compliant
A4 - Option to Ferno 175 -1— CN8 Not Compliant
AS — Option to Ferno 175 -3 — CN8 Not Compliant
A6 — Option to Ferno 175 -4 — CN8 Not Compliant
A7 — Option to Ferno 175 -5 — CN8 Not Compliant
A8 — Option to Stryker 6370 — Single Position — CN8 Not Compliant
A9 — Option to Stryker 6371— Wall Mount — CN8 Not Compliant
A10 — Option to Stryker 6377 — Dual Position — CN8 Not Compliant
B. Van units — Ferno Stat Trac, model 185ST — 86" length — STANDARD — CN8 Compliant
B1— Option to Ferno 175 -1— CN8 Not Compliant
B2 — Option to Stryker 6371— Wall Mount — CN8 Not Compliant
3. Units ordered with Options other than the Stryker Power Load system or the Ferno Stat Trac
will require sending you an Exception Letter stating that the order does not conform to
Paragraph 3.11.6 of KKK- A -1822F as published on July 1, 2015. This Exception Letter will be
included in the Order Confirmation Process as part of the document package. It will also be
included in the Delivery Documents Package. This Exception Letter is RE UIRED for any
ambulance not fully meeting the KKK- A -1822F Standards and will be in your customer's
owner's manual /delivery document package.
4. We strongly recommend that you have a detailed conversation with your end - customer as to
this selection. In addition you should confirm with your State's EMS Regulatory Office that
this exception will not exclude the State's Ambulance Certification requirements to permit
licensure and operation in that State. You should send your end -use customer a copy of the
Exception Letter as part of your Order Confirmation Process with them.