Loading...
HomeMy WebLinkAboutItem III (C) Acceptance and Authorization for Mayor and City Clerk to Execute Addendum to Perform Groundwater Modeling of Land Application of Treated Wastewater at the City's Effluent Disposal Site/Golf Course with LJ Nodarse & Associates, Inc. } / AGENDA 1-4-94 Item III C "CENTE j F GOOD LIVING-PRIDE OF WEST ORANGE" OCOo@ S.SCOTT VANDERGRIFT 6i. 1 COMMISSIONERS .0-1.44 f ° CITY OF OCOEE RUSTY JOHNSON ' M O. 150 N.LAI�SHORE DRIVE PAUL W.FOSTER v D OCOEE FLORIDA 34761-2258 VERN COMBS �+�. ?V (407)656 2322 JIM GLEASON yfE� Op G0OD N> CITY r-' ELL S MANAGER SFiAPIRO TO: The Honorable Mayor and Board of City Commissioners FROM: Montye Beamer, Director (1 j Administrative Services U � � Date: December 29, 1993 RE: ADDENDUM TO PERFORM GROUNDWATER MODELING OF LAND APPLICATION OF TREATED WASTEWATER AT THE CITY' S EFFLUENT DISPOSAL SITE/GOLF COURSE As indicated at the December 7 , 1993 Commission meeting, the first task for the geotechnical consultants would be to perform the groundwater modeling required by the Florida Department of Environment Protection (FDEP) for the treated wastewater at the City' s effluent disposal site/golf course . The three geotechnical consultants responded; their proposals are attached. On December 22 , 1993 these proposals were reviewed by the City Engineer and the City' s consulting engineer . The selection criteria included: ( 1 ) scope of services , ( 2 ) schedule , and ( 3 ) proposed fee . Ken Hooper summarized the findings . His letter is also attached. It is staff ' s recommendation to award Addendum 1 to L . J . Nodarse & Associates , Inc . in the amount of $14 ,760 . 00 with 196 hours for completion. This recommendation is due to the understanding exhibited in their proposal as to what will be necessary to satisfy FDEP in the required time frame; its detail demonstrates that it will also be the most cost-effective . ACTION REQUESTED The Mayor and City Commissioners ( 1 ) award Addendum 1 to L .J . Nodarse & Associates , Inc . in the amount of $14, 760 . 00 with 196 hours for completion and ( 2 ) authorize the Mayor and City Clerk to execute . PEC PROFESSIONAL ENGINEERING CONSULTANTS, INC. December 28, 1993 P-3178 Mr. James W. Shira, P.E. City Engineer/Utilities Director City of Ocoee 150 North Lakeshore Drive Ocoee, Florida 34761 Re: Proposal to Perform Groundwater Modeling of Land Application of Treated Wastewater at the City's Effluent Disposal Site/Golf Course Dear Mr. Shira: As requested, I have reviewed the proposals from the City's three (3) geotechnical consultants, Universal Engineering Sciences (UES),Professional Service Industries, Inc. (PSI), and L.J. Nodarse and Associates, Inc. (UN). Listed below are comments concerning the scope of services, schedule and proposed fee. SCOPE OF SERVICES All three geotechnical firms identified an acceptable scope of services to perform the groundwater modeling as requested in the City's Request for Proposals (RFP). All firms proposed to use the MODFLOW simulation model, including calibration and coordination with FDEP staff. The UN scope demonstrated an exceptional awareness of existing groundwater conditions, including a detailed description of the interaction of the depressional lakes (sinks) and the breaches in the semiconfining layers above the aquifer. UN also described their extensive experience with the MODFLOW model and its uses. Summary The scope of services as described by UN is exceptional in detail and demonstrates a very good knowledge of the existing conditions. SCHEDULE The City has committed to FDEP to complete the groundwater modeling and provide the results by March 31, 1994. Assuming a notice to proceed can be issued on January 5, 1994, the schedule requires for completion of this assignment no later than 12 weeks. engineers planners surveyors 200 East Robinson Street • Suite 1560 • Orlando, Florida 32801 • 407/422-8062 • FAX 407/849-9401 Mr. James Shim December 28, 1993 Page 2 The schedules as identified in each proposal are as follows: UES - 12 weeks PSI - 12 weeks UN - 7-9 weeks Summary Based on the proposals, all firms indicated the groundwater modeling could be completed within the mandated timeframe. PROPOSAL FEE Each firm identified a proposed fee to complete the assignment. UES - $18,860.00 - 284 hours PSI - $13,800.00 - 201 hours (indicated a range of $12,000 to $15,000 depending on FDEP's response) UN - $14,760.00 - 196 hours RECOMMENDATION Based on the scope of services as provided by the consultant, schedule and proposed fee, I recommend the City of Ocoee use the consulting firm of L.J. Nodarse and Associates, Inc. to complete the assignment concerning the modeling of the groundwater at the City Effluent Disposal Site/Golf Course. The defined scope of services should provide the most cost-effective groundwater analysis and meet the City's schedule for compliance with FDEP permit conditions. Very truly yours, PROFESSIONAL ENGINEERING CONSULTANTS, INC. 9'' '?Vcite.-----._ K nneth R. Hooper KRH/kh cc: Montye Beamer ADDENDUM TO CONTRACT FOR PROFESSIONAL GEOTECHNICAL ENGINEERING AND TESTING SERVICES ADDENDUM NO. 1 PROJECT: GROUNDWATER MODELING OF LAND APPLICATION OF TREATED WASTEWATER AT THE CITY'S EFFLUENT DISPOSAL SITE/GOLF COURSE CITY: OCOEE, FL GEOTECHNICAL ENGINEER: L. J . NODARSE & ASSOCIATES , INC . Execution of the Addendum by City shall serve as authorization of GEOTECHNICAL ENGINEER to provide for the above project , professional services as set out in the documents which are attached hereto and made a part hereof . ATTACHMENTS: [X] Technical & Fee Proposal , Groundwater Modeling of Land Application of Treated Wastewater dated December 15 , 1993 GEOTECHNICAL ENGINEER shall provide said services pursuant to this Addendum, its attachment and that certain Agreement of January 1994 , between CITY and GEOTECHNICAL ENGINEER which is incorporated herein by reference as if it had been set out in its entirety. Whenever the Addendum conflicts with said Agreement , the Agreement shall prevail . TIME FOR COMPLETION: The work authorized by this Addendum shall be completed within one hundred and ninety-six ( 196 ) hours from the date this Addendum is executed by the CITY. COMPENSATION: The CITY shall compensate Geotechnical Engineer a negotiated fixed fee in the amount of FOURTEEN THOUSAND SEVEN HUNDRED AND SIXTY DOLLARS ( $14 , 760 . 00 ) for the service required under this Addendum. GEOTECHNICAL ENGINEER shall perform all work required by this Addendum; but , in no event , shall GEOTECHNICAL ENGINEER be paid more than the fixed fee set forth above . IN WITNESS WHEREOF, the parties hereto have made and executed this Addendum on this _th day of January, 1994 , for the purposes stated herein. By: Its : (CORPORATE SEAL ) APPROVED: ATTEST: CITY OF OCOEE, FLORIDA Jean Grafton, City Clerk S . Scott Vandergrift , Mayor ( SEAL ) FOR USE AND RELIANCE ONLY BY APPROVED BY THE OCOEE CITY THE CITY OF OCOEE, FLORIDA COMMISSION AT A MEETING APPROVED AS TO FORM AND LEGALITY HELD ON , 1994 this _ day of January, 1994 . UNDER AGENDA ITEM NO. FOLEY & LARDNER By: City Attorney Geotechnical, Environmental & Materials Engineers December 15, 1993 Project No. 93-0597 LI Nodarse TO: CITY OF OCOEE &Associates,Inc. 150 N. Lakeshore Drive Ocoee, Florida 34761 ATTN: Mr. James W. Shira, P.E. City Engineer/Utilities Director RE: Technical & Fee Proposal, Groundwater Modeling of Land Application of Treated Wastewater Ocoee Public Golf Links Facility City of Ocoee, Florida Dear Mr. Shira: At your request, we are pleased to present this technical and fee proposal to perform the above-referenced services. This proposal describes our technical approach, the estimated professional time requirements, associated costs and schedule for completion of the work. In summary, we propose using the transient MODFLOW simulation to predict the percolative capacity of the site. The analysis will be performed in accordance with modeling protocol that is consistent with FDEP requirements. The estimated time to complete the modeling study and deliver the final report is 7 to 9 weeks from your authorization to proceed. We understand that a March 31, 1994 deadline has been established by FDEP and we will meet this deadline. Our estimated fee to complete this work is $14,760.00. An itemization of this fee is presented in the proposal. We trust that this proposal is in order and we look forward to assisting the city on this project. Please do not hesitate to contact us if there are any questions. Sincerely, L.J. Nodarse & Associates, Inc. DR 3 ( L.J.---3"e Devo Seereeram, Ph.D. David B. Twedell Hydrogeotechnology Consultant Senior Environmental Consultant 'Le' ; I. in al Nodarse, P.E. • ;e. len 11 807 South Orlando Avenue♦Suite A♦Winter Park, Florida 32789♦Telephone 407.740.6110♦Facsimile 407.740.6112 TABLE OF CONTENTS 1.0 INTRODUCTION 1 2.0 TECHNICAL APPROACH 1 2.1 General 1 2.2 Methodology 2 2.3 Conceptual Model 3 2.4 Model Design 7 2.5 Calibration . . . .. . . . . . . . . . . . . . . . . . . . 10 2.6 Sensitivity Analysis 10 2.7 Model Verification 10 2.8 Prediction . . . . . . . . . . . . . _ _ 11 2.9 Field Audit Recommendations . . . 11 2.10 Water Balance & Nutrient Balance 11 2.11 Final Report 11 3.0 SCHEDULE 11 4.0 ESTIMATED COST 12 1.0 INTRODUCTION The 240-acre Ocoee Golf Course site is a combination rapid rate/slow rate reclaimed wastewater land application scheme. Slow-rate irrigation of the 18-hole golf course is combined with rapid rate disposal via two on-site percolation ponds. This proposal focuses on the technical approach for modeling and predicting the ultimate disposal capacity of the site. The City of Ocoee has been requested by the Florida Department of Environmental Protection (FDEP) to perform such an analysis to satisfy the requirements for a mounding analysis as per Chapter 17-610("Reuse of Reclaimed Water and Land Application")of the Florida Administrative Code(F.A.C.). The City of Ocoee has committed to deliver a report on this study to the FDEP by March 31, 1994. In addition to a discussion of technical aspects of the assignment, this proposal is divided into 3 sections: • Technical Approach. • Schedule For Execution of Work • Professional Fees 2.0 TECHNICAL APPROACH 2.1 General There are many appropriate numerical models and approaches to applying these models to predict the disposal capacity of a wastewater land application facility. In general, the choice of a methodology and its approach is influenced by several factors, including: • the hydrogeologic setting of the site, • the complexity of the areal distribution of artificial recharge within the site, • the magnitude of the artificial recharge rate (i.e., slow-rate or rapid-rate), • the various mechanisms of disposal (i.e., evapotranspiration, lateral seepage, vertical leakage, etc.) • the field data available, and • the guidance of the regulatory agencies. The methodology and approach described hereunder applies specifically to the Ocoee Golf Course site and is tailored to address the needs of the Florida Department of Environmental Protection. • Project No. 93-0597 Page 2 2.2. Methodology The ground water flow model chosen for our evaluation is the USGS MODFLOW model created by McDonald and Harbaugh. Given its widespread use over the past 7 to 8 years, this computer-based methodology is now regarded as the de facto standard for three-dimensional finite difference modeling of effluent disposal facilities in Florida. The steps in a typical MODFLOW modeling protocol include: 1. Develop a conceptual model of the system: Hydrogeologic units and system boundaries are identified. Field data are assembled including data needed to assign values to aquifer parameters and hydrologic stresses. 2. Model design: The conceptual model is put into a form suitable for modeling. This step includes design of the grid, selecting time steps, setting boundary and initial conditions, and preliminary selection of values for aquifer parameters and hydrologic stresses. 3. Calibration: The purpose of the calibration is to establish that the model can reproduce field-measured heads. During calibration a set of values for aquifer parameters and stresses is found that approximates field-measured heads. Calibration is commonly done by trial and error adjustment of parameters, although automated methods are now being introduced into the practice. 4. Calibration sensitivity analysis: The calibrated model is influenced by uncertainty owing to the inability to define the exact spatial distribution of parameter values in the problem domain. There is also uncertainty over defmition of boundary conditions and stresses. A sensitivity analysis is performed in order to establish the effect of uncertainty on the calibrated model. 5. Model verification: The purpose of model verification is to establish greater confidence in the model by using the set of calibrated parameter values and stresses to reproduce a second set of field data. If a second set of field data does not exist, model verification is necessarily skipped. 6. Prediction: quantifies the response of the system to future events. The model is run with calibrated values for parameters and stresses, except for those stresses which are expected to change in the future. Estimates of the future stresses are needed to perform the simulation. Project No. 93-0597 Page 3 7. Reporting of modeling design and results: clear presentation of model design and results is essential for effective communication of the modeling effort. 8. Field Audit: A field audit is conducted as the future stresses modeled in the prediction simulation are actually approached. New field data are collected to determinewhether the prediction was correct. Typically the field audit will lead to new insights into system behavior which may lead to changes in model parameters and a more refined prediction. Each of the above steps, as they relate to the Ocoee Golf Course,are discussed in more detail below. 2.3 Conceptual Model A conceptual model is a pictorial representation of the ground water flow system, frequently developed in the form of a block diagram. The two steps in building a conceptual model are defining the hydrogeologic units and defining the flow system. Both of these steps are described below for the Ocoee Golf Course site, followed by a discussion of the relationship between the conceptual model and the digital model. 2.3.1 Hydrogeology The hydrogeology at the Ocoee Golf Course may be generalized as follows: Lithologic Unit Thickness Hydrogeologic Unit Clean Fine Sand 12 to 50 feet Permeable portion of surficial aquifer Cemented fine sand/ 20-30 feet Semi-confining unit "hardpan" type 1 Hawthorn Clays 75 to 120+ ft thick Semi-confining Hawthorn Group Ocala Group Limestone occurs at a depth of 160 to Floridan aquifer 220 ft below land surface The sixty (60) borings drilled throughout the site disclosed a stratigraphy that is very consistent within the site. There is an upper mantle of clean fine sand underlain by dense, much less permeable "hardpan" type soils. The permeability of the clean fine sands is in the range 40 to 90 ft/day, while the permeability of the hardpan is on the order of 0.02 ft/day. Since the hardpan is over 1000 times less permeable than the upper Project No. 93-0597 Page 4 sands, it acts as a semi-confining layer retarding the downward movement of ground water from the uppermost aquifer. The top of the hardpan layer is of the same general shape as the land surface topography. It is generally 12 to 18 feet below land surface in Site #5 and the interconnecting 30 acre tract, 20 feet below land surface west of the proposed beltway on Site#8, 30 to 50 feet deep on the eastern boundary of the site, and about 50 feet deep around the rim of the lakes. Underlying the hardpan soils are the Hawthorn. Group soils which are comprised of greenish gray clays with some beds ofsands and thin layers of shell, limestone and interspersed phosphate grains. The top of the Hawthorn is about 50 feet below land 'surface and extends to a depth of 160 feet to 200 feet below land surface where it contacts with the Ocala Group limestones of the Floridan aquifer. The top of the limestone is eroded in this area. The Hawthorn is at least 75 feet thick and is maybe over 120 feet thick. According to previous reports, the groundwater table contours generally mimic the ground surface contours. The pre-development groundwater table is generally 10 to 20 feet below land surface and is generally deepest in the eastern portion of the site. Lakes #1 and #2 act aspronounced internally drained sinks in the ground water flow regime. The potentiometric surface of the Floridan aquifer varies seasonally from +58 ft to +63 ft MSL as compared to water levels in Lakes #1 and #2 of +90 and +115 ft MSL respectively. These elevation differences are evidence that the on-site depressional lakes are not well connected to the Floridan aquifer. Water movement in the Floridan is to the north and northeast. Recharge maps published by St Johns River Water Management District indicate that the recharge from the surficial aquifer to the Floridan aquifer is 8 to 10 inches per year within the site. There are no adjacent surface water bodies with positive outfalls. Lake Sims and Trout Lake, approximately 1600 feet to the east of the site, are both internally drained but are better connected to the Floridan aquifer than the on-site depressional lakes. Lake Apopka, which is poorly connected to the Floridan aquifer, is over a mile to the west of the site and therefore outside the radius of influence of the hydraulic loading on the site. 2.3.2 Fate of Recharge Water At The Ocoee Golf Course Site Before describing the conceptual model, it is important to provide an explanation of the fate of the recharge water after it infiltrates into the ground. First, it is important to reiterate that the project site is located within a closed drainage basin. That means that there are no rivers, creeks, or other surface water bodies which can intercept ground water and discharge it outside the limits of the basin. Therefore, discharge of ground water from the surficial aquifer system within the basin is by evapotranspiration and by Project No. 93-0597 Page 5 vertical leakage to the Floridan aquifer. The latter component is much higher within the depressional Iakes where the semi-confining Iayers are partially breached. The portion of the recharge water not consumed by either evaporation or evapotranspiration will percolate downward below the soil-root zone. Infiltration will be rapid through the well-drained sand lithology present on-site. The water table will rise as a result of the increase in recharge. A ground water mound will form in the uppermost aquifer, inducing lateral flow away from the wetted area. As the ground water mound spreads beyond the limits of the wetted area, it starts filling the available soil void space above the preloading water table. The mound continues to spread until_ the lateral hydraulic gradients that develop can dissipate the artificial recharge. At the radius of influence or lateral extent of the mound, the water table level is close to the preloading Ievel (i.e., there is little or no mounding effect). Note that a considerable quantity of water can be stored in the soil voids above the water table especially on the "high and dry" sand hills which typify the site vicinity. The increase in head in the uppermost aquifer as a result of the mounding creates additional downward vertical leakage through the semi-confining unit (i.e.,the hardpan and Hawthorn clays) to the Floridan aquifer. This vertical leakage rate is, however, not uniform across the site. It is much greater where the semi-confining layers are breached such as in the on-site and off-site depressional lakes. In summary, the ultimate height and lateral extent of the groundwater mound due to the long-term application of effluent at the land surface depends upon several factors, including • the rate at which recharge water arrives at the water table • the thickness, fillable porosity, and hydraulic conductivity of the uppermost aquifer, • ambient groundwater levels in the surficial aquifer, • the leakage coefficient of the semi-confining unit, inter-aquifer head difference, and transmissivity of the underlying Floridan aquifer, • the areal distribution of the effluent application rate, and • the geometry of the hydraulically loaded area. 2.3.3 Relationship Between Conceptual Model and Numerical Model Based on the above discussions of the hydrogeologic units and the flow systems, the numerical model is formulated as follows: Simulation Type: Transient Model Type: Full Three-Dimensional . • Project No. 93-0597 Page 6 Model Layers: The model will be set up as a two-layered system: Layer #1 (unconfined): uppermost zone of clean fine sand semi-confining unit (not a model layer) Layer #2 (leaky confined): the Floridan limestone aquifer 2.4 Model Design 2.4.1 Model Grid The rectangular model grid will extend out at least 1000 feet from the edge of the wetted area. The project site will be centered in the grid. Nodal spacing will be selected during final design. 2.4.2 Boundary Conditions Specified head boundaries will be set in the grid cells and located about 1000 feet from the edge of the wetted area. This setback is considered large enough to prevent the boundary conditions from influencing the solution. Grid cells beyond this locus will be inactive while grid cells within the boundary cells will all be active variable head cells. The locations of the boundary and active cells will be the same in Layers #1 and #2. The head values in the boundary cells will be set as follows: Layer #1: annual average water table elevation Layer #2: annual average potentiometric surface elevation Since site-specific water table measurements will not be available at the off-site boundary cells, the water table elevations will be estimated by reviewing the SCS soil map units and the SJRWMD 1-foot topo of the area. For Layer #2, the specified heads in the boundary cells will be based on the USGS/SJRWMD Floridan aquifer potentiometric surface map for a selected normal rainfall year. In order to prevent artificial recharge stresses from migrating out to the boundary and causing a simulated effect that is unrealistic, the simulation will be terminated after a predetermined simulation time. This simulation time, however, will not be less than 2 years or such other simulation time mutually agreed upon with the FDEP. If a pump station is to be installed in Lake #1, "drain" cells (within Lake #1 in Layer#1) may be used to model the discharge/recirculation rates and to control the stage elevation. • • Project No. 93-0597 Page 7 2.4.3 Initial Conditions • Initial conditions refer to the head distribution throughout the system at the beginning of the simulation. It is standard practice to select as the initial condition, a steady-state head solution generated by the calibrated model. This initial head distribution represents dynamic average steady-state conditions where head varies spatially and flow into the system equals flow out of the system. 2.4.4 Preliminary Selection of Aquifer Parameter Values The list of aquifer parameters in Table 1 will be required for the conceptual model. _ TABLE 1: AQUIFER PARAMETERS REQUIRED FOR CONCEPTUAL MODEL LAYER # TYPE . I AQUIFER PARAMETERS 1 Unconfined or a. Hydraulic conductivity upper clean sand Water table b. Fillable porosity c. Base elevation of aquifer not a model layer Semi-confining unit . a. Vertical leakage coefficient 2 a. Transinissivity Floridan aquifer Leaky confined b. Storage coefficient There is considerable site-specific data on the hydraulic conductivity and base elevation of Layer #1. Kriging will be used to interpolate the base elevation of Layer#1 between the boring locations and areas of the model domain outside the site limits. There is much less uncertainty associated with estimating the fillable porosity of Layer #1. Values of fillable porosity of these fine sands are generally in the range 25% to 30%. Estimates of the Floridan aquifer parameters will be obtained from published data and any information available from the Water Management District and the FDEP. The vertical leakage coefficient will vary within the model domain. For example, it will be much higher in the depressional lakes. This parameter will be refined during the calibration, but the leakage coefficient will be initially selected to ensure that recharge from Layer #1 to Layer #2 is consistent with the published recharge rates of 8 to 10 inches per year. 2.4.5 Preliminary Selection of Natural Hydrologic Stresses Natural recharge to Layer #1 is equal to Rainfall Runoff and Evapotranspiration. On these excessively drained sand pine hills, the recharge to Layer #1 is generally about 15 inches per year with the following components: Project No. 93-0597 Page 8 Rainfall = 50 inches/year • Rainfall Runoff = 0.2 inches/year (Curve Number = 45) Evapotranspiration = 35 inches/year The evapotranspiration rate in the lakes and poorly drained soils around the lakes is about 50 inches/year. Recharge to Layer #1 will therefore be simulated as 15 inches/year on the excessively drained sandy soils and 0 inches/year in the lakes. It is important to note that this is annual rechargefromthe atmosphere to the water table aquifer (Layer #1) and not recharge to the Floridan aquifer. The evapotranspiration rates will increase in the postdevelopment condition due to the change in vegetative cover, the rise in water table, and the controlled rate and distribution of the reclaimed water spray. Postdevelopment evapotranspiration rates on an optimally irrigated golf course is close to 50 inches per year. Therefore, the increase in evapotranspiration of the irrigated turf grass (50 in/yr) over the predevelopment pine communities (35 in/yr) is on the order of 15 inches per year. This translates to a potential additional disposal capacity of 270,000 gpd over this 240 acre site. In order to take advantage of the increase in postdevelopment evapotranspiration, the MODFLOW Evapotranspiration Module will be used to automatically model the increase in evapotranspiration as the water table rises. 2.5 Calibration Calibration of a flow model refers to a demonstration that the model is capable of producing field-measured heads which are the calibration values.. Calibration is accomplished by finding a set of parameters, boundary conditions, and stresses that produce simulated heads that match actual field-measured values within a preestablished range of error. There are basically two ways of finding model parameters to achieve calibration; (1) manual trial and error adjustment of parameters and; (2)automated parameter estimation. The manual method is the one most preferred by the FDEP practitioners and will be the method used in this modeling effort. As requested by the FDEP, the field data used in the calibration will be the site-specific predevelopment ground water table contour map. 2.6 Sensitivity Analysis The purpose of a sensitivity analysis is to quantify the uncertainty in the calibrated model caused by uncertainty in the estimates of aquifer parameters, stresses, and boundary conditions. During a sensitivity analysis, calibrated values for hydraulic conductivity, storage parameters, recharge, and boundary conditions are systematically changed within previously established ranges. The magnitude of change in heads from the calibrated Project No. 93-0597 Page 9 solution is a measure of the sensitivity of the solution to that particular parameter. The results of the sensitivity analysis are measured by the effects of the parameter change on the average measure of error selected as the calibration criterion. 2.7 Model Verification Owing to uncertainties in the calibration, the set of parameter values used in the calibrated model may not accurately represent field values. Consequently, the calibrated parameters may not accurately represent the system under a different set of hydrologic stresses. During verification, values of parameters and hydrologic stresses determined during calibration will be used to simulate a transient response for which a set of field data exists. The hydraulic loading and observed ground water level responses of the golf course system and existing percolation ponds will be used for verification of the calibrated model parameters. 2.8 Prediction In the predictive simulation, the parameters determined during calibration and verification will be used to predict the response of the system to future events. It is at this point that the increase in evapotranspiration will be taken into account in the postdevelopment condition. In addition to the natural stresses, artificial recharge stresses will be applied to the calibrated/verified model to simulate the ultimate disposal capacity of the site. This exercise is a trial and error process where the recharge distribution is varied from zone to zone within the golf course until the ground water mound is within the level acceptable to the FDEP. Acceptable, in this sense, means that the mound does not rise to within 2 feet of the ground surface at any point. The results of the prediction will be the percolative capacity of the site and the approximate distribution of disposal capacity within the site. 2.9 Field Audit Recommendations The model domain will extend approximately 1000 feet beyond the limits of the property where detailed geotechnical data is not available. Therefore, by necessity, there will be extrapolation of aquifer parameters within this area. The model predictions will therefore reflect some judgement in estimating these parameters. Because it is desirable to maximize the disposal capacity of the site, it is recommended that the City of Ocoee implement a monitoring plan which will facilitate a field audit of the model predictions. Such a plan will allow the city to maximize the actual permitted disposal capacity of the site in the future. This operating plan will include ground water level observation wells to measure the mound and compare it to the model prediction. After approximately a year of loading • Project No. 93-0597 Page 10 at 75% of the permitted capacity, a field audit can be conducted to re-rate the site capacity based on actual performance. Our experience shows that this is the most effective and assured approach for maximizing the disposal capacity of a large facility, and is also preferred by the FDEP. 2.10 Water Balance and Nutrient Balance The following factors limit the effluent disposal capacity of a reclaimed water irrigation scheme: ■ Percolative (or hydraulic) capacity which is the ability of the sprayfield to be hydraulically loaded with effluent and excess rainfall, (i.e. precipitation-runoff- evapotranspiration) without creating adverse groundwater mounding impacts (i.e., seepage outcrops and ponding conditions). From a treatment and operational standpoint, it is desirable to maintain the ground water mound at a minimum depth of 2 feet below land surface. • Uptake of effluent chemical constituents (primarily nitrogen and phosphorus) by the vegetative cover and the soil plant-root zone to limit potential adverse groundwater quality impacts. • Holding pond capacity which is required for storage during periods of excess precipitation, down time for maintenance of the irrigation equipment, or other standby time. The FDEP, by rule, requires a minimum wet weather storage equivalent to 3 days of average daily flow. • "Hardware" and operational (management) limitations related to the capacity of the installed pumps and transmission lines and the available hours for irrigation, rotation schedule, etc. One result of the MODFLOW analysis will be the percolative capacity of the site. This percolative capacity will be used in a spreadsheet model for the water balance and nutrient balance computations for the golf course site. 2.11 Final Report A modeling report will be prepared in a format acceptable to the FDEP, and will include the following sections: • INTRODUCTORY MATERIAL • HYDROGEOLOGIC SETTING AND CONCEPTUAL MODEL • MODEL DESIGN AND RESULTS The Code Relationship Between Conceptual Model and Numerical Model Project No. 93-0597 Page 11 Model Calibration and Verification Sensitivity Analysis Predictions Water Balance and Nutrient Balance • MODEL LIMITATIONS • SUMMARY AND CONCLUSIONS • REFERENCES • APPENDICES • Note that field audit recommendations may be presented separately from the modeling report. 3.0 SCHEDULE The estimated time for completion of this study is 7 to 9 weeks from your authorization to proceed. In order to expedite completion of the project, we will need your assistance to obtain the following information: • Hydrologic monitoring data and flow records maintained by Robert Holland at the city's wastewater treatment plant • AUTOCAD data file in DXF format containing the as-built plans of the golf course • Stormwater management reports which describe control levels and control mechanisms for the on-site lakes Upon receiving authorization to proceed from the city, an initial meeting will be arranged with FDEP staff to present the Plan of Study (similar to that outlined in this proposal). Follow up meetings will be scheduled with FDEP staff as necessary to present details and obtain concurrence on key aspects of the model such as the grid layout, the calibration, etc., as the modeling progresses. We believe that by working closely with the FDEP during all phases of model set-up and calibration, we can ultimately reduce their response time to our request for permit modification. Project No. 93-0597 Page 12 4.0 ESTIMATED COST U Item// Task Description Unit Rate Quantity Amount A FIELD VISIT& DATA REVIEW A.1 Senior Engineer/Scientist hr $85.00 6 $510.00 B GROUND WATER MODELING B.1 Principal Engineer/Scientist hr $100.00 6 $600.00 B.2 Senior Engineer/Scientist hr $85.00 100 $8,500.00 C DOCUMENTING & REPORTING OF MODELING STUDY C.1 Principal Engineer/Scientist hr $100.00 6 $600.00 C.2 Senior Engineer hr $85.00 20 $1,700.00 C.3 Drafting Services hr $30.00 24 $720.00 C.4 Secretary hr $30.00 16 $480.00 D MEETING TIME & COORDINATION D.1 Principal Engineer/Scientist hr $100.00 8 $800.00 D.3 Senior Engineer/Scientist hr $85.00 10 $850.00 TOTAL $14,760.00 4 f � ~vim Professional Service Industries, Inc. Jammal & Associates Division December 21, 1993 Proposal No. 757-3-652 TO: The City of Ocoee 150 North Lakeshore Drive Ocoee, Florida 34761 Attention: Mr. James W. Shira, P.E. City Engineer/Utilities Director SUBJECT: Proposed Scope of Work and Cost Estimate, Evaluation of Effluent Disposal Via Spray Irrigation for City of Ocoee Golf Course Site, Ocoee, Florida Dear Mr. Shira: As requested, we have prepared our proposed scope of services to complete the mounding analysis for the above referenced site and provide input to modifications of the existing Florida Department of Environmental Protection (FDEP) permit for the site. Our proposed scope of work, related fees, and time schedule are presented herein. PROPOSED SCOPE OF WORK Based on our understanding of the project requirements and the project history,we envision that our work will consist of five tasks which will be performed sequentially. To summarize, Tasks 1 and 2 will consist of compiling and/or generating site- specific soil, surface water, groundwater level, and loading rate information as input to the preparation of groundwater level maps and formulating our approach to the project. Task 3 will consist of the formulation of our analysis methodology and subsequent presentation to and interaction with representatives of the FDEP. The implementation of our analysis/modeling, summary report preparation, and response to FDEP comments will comprise Tasks 4 and 5, respectively. A brief summary and schedule relative to each of the tasks follows. 1675 Lee Road • Winter Park, FL 32789 • Phone:407/645-5560 • Fax:407/645-1320 City of Ocoee Golf Course 'Proposal No. 757-3-652 -2 Task 1 Based on our understanding of the project history, Task 1 will consist of compiling previous site-specific subsoil and groundwater level reports and evaluations prepared by previous consultants (including our firm). As you are aware, the bulk of this work was completed during our earlier involvement with the project. Therefore,we do not envision that this task will require a significant amount of time and can be completed within one week of authorization to proceed. Task 2 We understand that the golf course will be open to the public on January 28, 1993. Recent visits to the site and discussions with the golf course architect and the City of Ocoee's general engineering consultant indicate that the site is being heavily irrigated as part of the "greening in" of the course. We are currently installing a total of ten monitoring wells that were required by the FDEP for the groundwater monitoring plan approved with the original permit application. Groundwater level data for these wells should be available by mid- January, 1994. The referenced monitoring wells will provide valuable insight into the groundwater level conditions on the site as they relate to the heavy irrigation required during the greening in period for the golf course. In addition to the data provided by these monitoring wells, we propose to install a number of temporary piezometers in areas of the site where groundwater level data is not available. Based on recent discussions with representatives of the FDEP, it was their impression that the temporary piezometers would be installed prior to commencement of the full evaluation of the site. These piezometers would be installed by hand, in areas that would not be considered a hinderance to course maintenance. The groundwater level data from the monitoring wells and temporary piezometers, combined with irrigation/loading data from the golf course architect will be compiled and utilized to prepare current groundwater level maps for the site. This task will require approximately four weeks to complete following authorization of the project. We understand that ground surface and well datum elevations at monitoring wells currently being installed by our firm will be determined by others. We would request that elevations at the proposed temporary piezometers by determined at the time the monitoring wells are surveyed. Tasks 3 and 4 Once groundwater level maps have been prepared for the current site conditions, we will formulate a modeling/analysis approach that will later be presented to the FDEP for their review and comment. It is possible that the evaluation of the site may not require a fully three-dimensional analysis. It is conceivable that groundwater level data from the monitoring wells and temporary piezometers, in concert with loading rate data, would allow us to determine a safe loading capacity for the site without performing a mounding analysis. City of Ocoee Golf Course Proposal No. 757-3-652 -3 Once we have formulated our analysis strategy, we will meet with representatives of the FDEP to discuss and present our proposed methodology and reach agreement as to specifics of the model/analysis. Once this agreement has been reached,we will begin our evaluations in earnest. While we are completing our evaluations,we will update the FDEP periodically to discuss the project status and to address any conditions which were not anticipated during our initial discussions/agreement. We anticipate Tasks 3 and 4 can begin within three to four weeks of authorization to proceed and can be completed within eight to ten weeks following project commencement. Task 5 Upon completion of our analysis, we will prepare a summary report for the City and FDEP summarizing our approach, the analysis and results, and our recommendations relative to the future utilization of the site. We will work very closely with the FDEP during this process to assure that by the time our final report is submitted for review, all concerns will have been addressed. Therefore, it is our opinion that final review and approval by the FDEP should take less than thirty days. Relative to project time frames, and in consideration of the other tasks involved in this project, we anticipate that we can submit the final report to the FDEP not more than 12 weeks following authorization for proceed. Level of Effort and Estimated Fees For this project, mainly three professionals will perform the work. For your review and consideration, we have broken down the anticipated involvement for each individual (in man-hours) for each task area. The following table summarizes the anticipated involvement, by task. Level of Effort S. E. Jammal, P.E. Doug Hearn, P.G. Scott Cavin, E.I. Task # (Principal Engineer) (Sr. Hydrogeologist) (Project Engineer) 1 1 4 -- 2 6 16 -- 3 12 28 -- 4 10 24 40 5 8 12 24 An outline of the proposed scope of services and related costs to complete all Tasks are provided on Attachment A. The anticipated fee for our involvement in the project is $13,800. Please note that due to unforeseen circumstances and/or revelations during the project, our fees may decrease if work items may be deleted. Therefore we anticipate that oI% IlaigaLfrs may vary between $12,000 and $15,000 for the work. rte• City of Ocoee Golf Course Proposal No. 757-3-652 -4 As described above, it is possible that a full-fledged mounding analysis with three- dimensional modeling may not be required for this project. In the event that the FDEP is willing and will approve a site rating based on recent historical data, the line item and related fees presented as Item 4.1.3 would be eliminated from our contract, a net savings of $2,000 from the estimated project total of $13,800. CLOSURE PSI/Jammal & Associates Division appreciates the opportunity to submit our proposal for Ocoee Golf Links project and trust that this proposal will address your needs and concerns for the project. Should you have any questions or require additional information, please contact the undersigned at (407) 645-5560. Sincerely, PSI/JAMMAL & ASSOCIATES DIVISION /#11 . _ .011. HeP.G. �� .E � . , : Seni e ' . s !eolo ist P4 i/s Y _ g a n neer Fl. '' -:istration No. 1279 Fl. Registration No. 16121 DJH/SEJ:jds Enclosure: Attachment A 7573652.001 Mme' [fi�rr 888 8 8808 88 888 888 888 8p88 888 8 O OO aM0 $ tO�fNNN p1p � No0N0 asit on NM ci NyO� O NpNOp 8 E. H(A N I H �41U H. �H4 Hy N H�y �HH mad '4 ([aye H H N W 0 -. O9 .o a0N .1. .I. VNg 'cm .P00N • V y Fa W 0 D F y 88 888 88 8 888 88 8 8 888 88 8 8 0.. w yO Of ..f O vlO viO v166 v1O NOO vO Q O c O O HHOy Hy4 04 Hy y 44 H gVI H V H o I- I W s e i 1 S s 2 s4w p n 0 y y m m' w 4 a 3 m A< a. 1 a YY QY E.a11 z. mslvYa a .ca Al .4 sY ` A .01 RF ttl Up3 U4V iUW a (4 Ld.Cd o A $ E. 0 < 2 o w a < H w �i 0 I Qao. W < w $ g i z a z 2 i a " El @ >. H il Ia a = dew a v . w = Qw a ss W U G7 o W ,,, q0 0 g..9. R w go o R: go E� go g0 A ! C37 FoW'S't C.3 A G5 p C5 �J E�", P. y =, a z G`5 C5 g V § 34 ' .pI a � a F`/.!� A a Y a pr; O c? Y Cwl FI Y m Ou0 Y '00 r1 Y '00. F Y i Q Y 'OO Y '00 4 "' ' 50iw W § 0,111.i1-. � "' °waw z w "' i °° `3 x< C°47 °° `3 5F a `U3 a `3 4 C7 a i w a o � M 0 3 -2Hq T. C 8 �..1 $ w $ oC7w 'o 3 �yW o . w 'o W U 3 ' 3 dA.a 2.EE o.°' c 1aac� lw a a oa .l is p� C u O A z v Q O •. l O. l C u OG u Q w�W'C 1121 OG Prv� �7 .. 0 z W Uav� p. H ' . iLv� <aWm U lY. Wv. FO4W0 W o. F .r N m ♦ h (< A _ yW w ...4e4 — — c W ^+ Nat '+ N .. NM .+ N ;'1'4 ^" N ^"^; N N CI �+ .+ NN N4N N N ,.4 �+ �+ N el N < W F �+ F N N N N N F ei M M Men en F F v1 of v1 of of of v1 j UNIVERSAL Offices in: •Orlando •Ocala ,ENGINEERING SCIENCES •GainesviIle •Fort Myers Consultants In:Geotechnical Engineering • •Merritt Island Environmental Sciences•Construction Materials Testing •Daytona Beach •West Palm Beach December 22, 1993 City of Ocoee 150 North Lakeshore Drive Ocoee, Florida 34761 Attention: Mr. James W. Shira, P.E., City Engineer/Utilities Director Reference: Proposal to Perform Groundwater Modeling City of Ocoee Public Golf Course and Reclaimed Water Disposal Site Ocoee, Florida Dear Mr. Shira: Universal Engineering Science (UES) is pleased to submit the scope of services, cost estimate, and schedule to complete the mounding analysis for the City of Ocoee's Public Golf Course Reclaimed Water Disposal Site. As described in our Statement of Qualifications and as presented in our presentation, UES has extensive experience in successfully completing mounding analyses for effluent disposal sites of similar nature to the golf course site. Mr. Thomas Zankert, P.G., who will be performing the computer modeling for the project, has been working on effluent disposal projects in Florida for the last eight years. He has a thorough working knowledge of the reuse rule (FAC 17-610) and of MODFLOW which is the model of choice for the mounding analysis. He has also established a good working relationship with FDEP personnel directly responsible for review and approval of the groundwater modeling. All of these aspects are essential to establish a defensible effluent disposal model for the golf course site and to resolve the pending permitting issues. PROJECT UNDERSTANDING Based upon our file review and our discussions with Mr. Ken Hooper, P.E. and Ms. Sarah Whitaker of the Florida Department of Environmental Protection Groundwater Section a groundwater mounding analysis is required to establish the permittable disposal capacity for the golf course site. The proposed effluent disposal capacity for the site is 2.25 mgd which will be applied by a combination of spray irrigation of the golf course and rapid infiltration via two existing and two proposed rapid rate percolation ponds at the site. The groundwater modeling efforts for the site were rejected by FDEP for reasons related to model set-up and calibration. In a Letter of Understanding, the City of Ocoee agreed to limit the disposal capacity of the golf course site to 1.0 mgd pending results of additional groundwater modeling efforts. The City also agreed to submit the results of the mounding analysis, and the necessary permit modifications, if required, to FDEP no later than March 31, 1994. 3532 Maggie Blvd. • Orlando, FL 32811 • (407) 423-0504 City of Ocoee Attention: Mr. James W. Shire, P.E., City Engineer/Utilities Director Reference: Proposal to Perform Groundwater Modeling City of Ocoee Public Golf Course and Reclaimed Water Disposal Site Ocoee, Florida December 22, 1993 Page 2 PROJECT APPROACH In order to establish the permittable effluent disposal capacity for the golf course site, UES proposes to perform a mounding analysis using the groundwater flow model MODFLOW. Based upon our experience and our discussions with Sarah Whitaker, MODFLOW is the model of choice. In the MODFLOW model structure one can account for site specific hydrogeologic features such as the shallow hardpan layer and the sink hole lakes, both which are important in the development of the groundwater mound in response to the application of the treated effluent. UES proposes to prepare a permittable mounding analyses to establish the effluent disposal capacity for the site by conducting the four following tasks. TASK 1 - Construct Conceptual Hydrogeologic Model For this task, UES will review and summarize existing site specific and regional hydrogeologic data from existing site specific reports and published data by the Florida Geologic Survey, the St. Johns River Water Management District and other governmental agencies. We also plan to review and analyze the water level data which the City has been collecting at the site. This data will be used for the set up and calibration of the model. Data to be compiled include information regarding site stratigraphy, depth and thickness of confining beds, hydraulic conductivities of the soils, water level data and variations, climatic data, and other data needed for input into the groundwater flow model. Based on this review, we will construct a conceptual model of the site which will be used to set up (and later defend) the model structure within MODFLOW. This task is extremely important since understanding the site specific hydrogeology is essential prior to attempting to construct a mathematical analog of the site. TASK 2 - Groundwater Modeling The initial task will be to set up the model and model grid. We plan to extend the model grid beyond the site boundaries to incorporate regional hydrogeologic boundaries such as lakes and groundwater divides. Using this approach will eliminate FDEP's concerns regarding influence of the boundary conditions on the predictive analyses. Upon completion of the model set up, we will present this data and the proposed modeling approach (including the treatment of the sink hole lakes in the model) to FDEP for discussion to minimize the inquiries on the modeling methodology after the results are presented to the agency. We will then proceed to calibrate the model using both predevelopment and postdevelopment pp (load test) water table data to assure that the model response reasonably simulates the " City of Ocoee Attention: Mr. James W. Shira, P.E., City Engineer/Utilities Director Reference: Proposal to Perform Groundwater Modeling City of Ocoee Public Golf Course and Reclaimed Water Disposal Site Ocoee, Florida December 22, 1993 Page 3 conditions observed in the field. In addition, we will perform a sensitivity analysis of the input parameters to assure that model set up and input will provide a defensible mounding analyses. Once the model is calibrated, we will run the predictive analyses to establish the site disposal capacity for both the golf course spray irrigation and the existing and proposed percolation ponds. The predictive analyses are only meaningful if the model is calibrated properly. We have allocated a total of 50 hours for calibration which should be adequate to calibrate the model to the degree acceptable to FDEP. TASK 3 - Report Preparation In order to speed up the permitting process and to minimize questions from FDEP, UES will prepare a report which will present the model set-up, assumptions, calibration procedures, and modeling results in an organized and concise manner. We also plan to present the results to FDEP personnel in a meeting prior to submitting the final report to address any questions that they may have. TASK 4 - Permitting Assistance UES is prepared to assist the City of Ocoee with the permit modification or negotiations with FDEP, if required. SCHEDULE In order to meet the City's March 31, 1994 deadline, we propose to conduct the above work according to the following schedule: Task Completion Date Review& Compile Existing Site Specific & Regional Hydrogeologic Data 1/22/94 Set-Up Model & Meet with FDEP to Present Approach 2/11/94 Groundwater Modeling 3/11/94 Draft Report to City of Ocoee 3/18/94 Final Report to FDEP 3/29/94 City of Ocoee Attention: Mr. James W. Shira, P.E., City Engineer/Utilities Director Reference: Proposal to Perform Groundwater Modeling City of Ocoee Public Golf Course and Reclaimed Water Disposal Site Ocoee, Florida December 22, 1993 Page 4 CLOSING The cost estimate to complete the above mentioned tasks is attached. If acceptable, we will perform the proposed work in accordance with our contract with the City of Ocoee and the attached Cost Estimate. Please be assured that UES understands the urgency of the pending permitting issues for the golf course, and we feel confident that using the proposed modeling approach and Mr. Zankert's modeling experience with MODFLOW at similar sites in Central Florida we will help resolve the pending permitting issues. UES appreciates the opportunity to provide the City of Ocoee with assistance on this project. If you have any questions during the review of this proposal please call us at 423-0504. Respectfully submitted: Universal Engineering Sciences __A-tNJ).241_,4- Thomas M. Zankert, P.G. Senior Hydrogeologist Martha D. Gia4:/.a-Q Project Coordinator TMZ:MDG:mec Enclosure: Exhibit I - Cost Estimate RP ,F 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8j 8 f Q O O O Ifp1 O O O O O O N 8 i O i § O CO IA !A V O N 2 Qm CI a a F 44 r479 Vl V! 40 49 1 4 ; f9 N 49 64 I 0i t 0. w Q a Q a , F G of m m m m v ` I\ N D Cl) N 1 W 1-- F CO 0 V 1 1- 1 �Q � O1 0 1— � RIA O O o N I Ma h O2v' a_1 o �. 1 • O GVW 1 li "A' --:eV - ! CO a co 1 .- ` co11) .- CI SR N QV ~ 0En cob i 8r aF44 CC C m 3 N O V & 8v m o o► • a• � 0. as as ,D b.V. E E E X a, ocn ascss 2 To os 2 or v fn y 2 C to C 8 aa a 8 cu �7• E p H o 43 o ° m 2, Z' o g r y c ° oo a ° c°( a oQ a ¢ d aQ , ¢ Q m ;