Loading...
HomeMy WebLinkAboutItem VI (E) Discussion: Florida Power Corporation - Clarcona/Crown Point Power SubStation AGENDA 5-3-94 1 "CENTER OF GOOD LIVING-PRIDE OF WEST ORANGE" Item VI E 9GOee S.SCOTT VANDERGRIFT CITY OF OCOEERUSTY SIO ON (Of/ r v � Q 150 N.LAKESHORE DRIVE PAUL W.FOSTER OCOEE FLORIDA 34761-2258 VERN COMBS l.1% ?� (407)656-2322 JIM GLEASON l�rP 0 f G00V N>> CITY MANAGER ELLIS SHAPIRO MFP-471 MEMORANDUM DATE: April 28, 1994 TO: The Honorable Mayor and Board of Ci Commissioners FROM: Russ Wagner, Director of Planning SUBJ: Clarcona-Crown Point Power Substation As indicated on the attached Fact Sheet and Study Area Map, Florida Power Corporation (FPC) is planning to construct a new 69 kV transmission line between an existing substation located near Clarcona-Ocoee Road and Apopka-Vineland Road and a new substation to be located near Fullers Cross Road and Ocoee-Apopka Road. As shown on the Study Area Map, FPC has identified a number of potential routes along which to extend the 69 kV line. As a practical matter, there are two main options . One route would extend through the city along Clarcona-Ocoee Road and Fullers Cross Road. The other route would largely go around the City borders on Apopka-Vineland Road to the east and McCormick Road to the north. It would then run south along Ocoee-Apopka Road to the Fullers Cross Road intersection. There are a number of issues concerning this project which the Commission may wish to consider: 1 . The southerly route would involve the installation of large scale electrical transmission lines extending through the middle of the entire northern residential development area of the City. 2 . The northerly route, while more costly in the beginning, would follow existing major roadways and impose less visual impacts on the future development areas of the City. 014 April 28, 1994 Page 2 3 . Clarcona-Ocoee Road will likely need to be upgraded and widened in the future as the northern portions of the City develop. This would necessitate modifications to the many sharp curves which exist along this roadway. If the power lines follow the existing rights-of-way, the power lines will need to be relocated to accommodate the corner modifications as well as future widening. 4 . The placement and visual character of the proposed substations should be considered relative to their impact on the future development areas of the City. 5 . Coordination with FPC at this juncture would help minimize potential adverse visual impacts resulting from this project and help encourage high quality development in the northern developing portions of the City. RW/emk • �• S. % Florida Power • Corporation FACT SHEET Clarcona-Crown Point 69 kV Transmission Line and Planned New Substation Project Description d A new transmission line and associated substation are needed to serve the rapidly growing area north of Ocoee and Winter Garden in Orange County. Existing facilities will not be able to provide reliable electric service to area customers by the winter of 1997/98. d FPC plans to build a 69 kV transmission line from the existing Clarcona Substation,near the intersection of Clarcona-Ocoee Road and S.R. 435, west to a new substation which is planned to be located in the vicinity of S.R. 437 and Fullers Cross Road. d The new line will be a single overhead 69 kV transmission circuit. d Total length of project is approximately 3.5 miles. pesign/Construction Anticipated muting may allow the transmission line to be generally constructed within or immediately adjacent to existing road rights-of-way, minimizing the need for clearing and impacts to wetlands or development. 1 Typical structures will be single wood poles approximately 75 feet tall. Concrete or steel poles will be used when additional height or strength are needed to meet design criteria. 1 Typical span lengths will be approximately 250 feet. 1 Minimum ground clearance of the transmission lines will be 45 feet. In some areas the transmission structures will be designed to accommodate underbuilt distribution circuits which will be a minimum of 15 feet above the ground. I Design will meet the requirements of the National Electrical Safety Code. Project Schedule 1 Public information open house: Thursday, April 21, 1994, at Ocoee Women's Club 1 Route approved by FPC: September 1994. I Permitting scheduled for 1995-96. 1 Construction now scheduled for mid 1997. 1 In-service date: November 1997. FPC Contacts 1 Michael Lamb, Real Estate Department, St. Petersburg. Phone: 813-866-5215. Bill Warren, Corporate Communications, Winter Park. Phone: 407-646-8266. • i •••••.•'• 'CU QNY13NIA-V)IdOdV 0 .• < 0 Z < -•, O w 'a� cc (L Z • J J • cc U O a Q Q Z Lu 0 co �— w co cc Z � < Z2Z -auNOWdO U 0 < 0 crOQO p dc Q ~ ,-. } z -�• "• . p -1 j ..'..., f•e 07' 0 • ■ -, v\ , ,. ■ % •; ro •���h g4—g. e 'cm N33np0w ' :0::;x.30 sittre, Enz. • ■ •C :.• ■ -__,- 'au N3oaVW • OP'• cc ' w r w ■ Cl)O. co i- -:c1• z w o1 ■ 2 ......... I •1 a . M w •_ Z • • �• `• U. 0 N �• ` Z I • . Q J �k4 b,s •'i . . • ..--.-..--.--rte- . }- Z • co • D0 p • p cn to .061 � '- CC ■ \'. _.0 ` ci za J L .tys `. 4:M••. ..• .._•.•'', , ... J i Er0 � O .• . • ',, , • `••` , a 0 zLi. = � • � 1. •� • �. _- - r-- o c� Z 3 v«v ars c, _ ':- 1t- w 1Z cc CO • " •�•••�l `• d 0 Y Q ` • Q • �• w� Ow � O �. �• .� I. co zcc QQ VOX D • ° > a w w I :.N., cn •'_•. o I • i U - I • cc -0--- i- . ' � co LL1 I . Z - INI D