Loading...
VII(A) Adair Point Final Subdivision Plan LS-02-008Mayor S. Scott Vandergrift Interim Citv Manager V. Eugene Williford _ _ r eater of Good r,-_ _ STAFF REPORT Agenda 05-04-04 Item VII A Co"missioners Danny Howell. District 1 Scott Anderson, District 2 Rusty Johnson, District 3 Nancy J. Parker, District 4 DATE: April 23, 2004 TO: The Honorable Mayor and City Commissioners FROM: Thomas Grimms, AICP, Senior Planne iirector/THROUGH: Russ Wagner, AICP, Community Development SUBJECT: Adair Pointe Subdivision Final Subdivision Plan Project # LS -02-008 ISSUE: Should the Mayor and City Commissioners approve the Final Subdivision Plan for Adair Pointe Subdivision? BACKGROUND: The Adair Pointe property includes 11 lots on about 3.52 acres of land. The property is located on the east side of Adair Street approximately 1,400 feet north of Wurst Road, between Vignetti Park and Sorenson Field. The subject property is currently undeveloped and is covered with trees. The surrounding land to the north is developed with garden apartments, zoned R-3; to the south is the Glad Tidings Church, zoned R-2; to the east are the ball fields of Sorensen Park, zoned R-1; to the west are single-family residential units, zoned R-1. DISCUSSION: In the Annexation Agreement, the property owner agreed to provide additional road right-of-way for Adair Street. Sheet C-3 of the Final Subdivision Plan shows the 25 feet of additional right-of-way dedicated by the Applicant to the City. This subdivision will not be gated. There will be a 6 -foot brick wall with appropriate landscaping on both sides of the entrance with the wall extending northward along Adair Street to the north boundary of the subdivision. Water and wastewater will be provided by the City. The developer was granted one waiver from the normal Code requirement of one (1) recreational amenity for a subdivision with 10- 50 lots. April 23, 2004 Honorable Mayor and City Commissioners Page 2 of 2 The justification listed in the waiver table on Sheet C-3 for not having any recreational amenity located within subdivision is that the developer would pay fees in lieu of installing recreational facilities inside the subdivision. DEVELOPMENT REVIEW COMMITTEE RECOMMENDATION: The Development Review Committee met on March 23, 2004 and reviewed the Adair Pointe Final Subdivision Plan. There was discussion of the various comments by the City Attorney, which were the only outstanding comments. The DRC voted unanimously to recommend approval of the Final Subdivision Plan subject to the comments of the City Attorney being incorporated into a revised Final Subdivision Plan prior to the Planning and Zoning Commission meeting. Staff has reviewed the revised Final Subdivision Plan, date-stamped April 7, 2004, and finds that all of the City Attorney's comments have been addressed. PLANNING AND ZONING COMMISSION RECOMMENDATION: On April 13, 2004, the Planning and Zoning Commission considered the proposed Final Subdivision Plan for Adair Pointe. The City Staff and the Developer's Engineer answered questions about recreation amenities, as well as about existing trees on the site and tree protection. The idea of requiring more trees to be planted to replace the large number of trees being removed, or requiring larger trees to be planted was discussed. There seemed to be a consensus that the City should consider requiring developers to replace trees that must be removed to accommodate new development. When the discussion was finished, the Planning and Zoning Commission voted unanimously to recommend approval of the proposed Final Subdivision Plan for Adair Pointe, per the Staff recommendation, with five (5) trees [4" DBH] to be planted along the north side of the retention pond, instead of two (2) trees as currently shown on the plan. STAFF RECOMMENDATION: Based on the recommendations of the Development Review Committee and the Planning and Zoning Commission, the Staff recommends that the Mayor and City Commissioners approve the Final Subdivision Plan for Adair Pointe Subdivision to the City Commission, as date stamped received by the City on April 7, 2004, with five (5) trees [4" DBH] to be planted along the north side of the retention pond, instead of two (2) trees as currently shown on the plan. Attachments: Location Map Adair Pointe Final Subdivision Plan, date stamped April 7, 2004 O:\Staff Reports\2004\SR04029 CC.doc CE ■IF T; a 11'=fT11 11 I III No 0 mimmimm mm m M mm mm mmlm��m om ME Oil mm mm mm 1■������:Tr1 STT` r wowr all I w�w-ft Mm .R �. ■• .■ .. •• .E 00 ... •_. M -AIF . m MIN mm mm =� wo .. ...m m/ ■'gym ■ nil COVER 2 EXISTING SITE SURVEY 3 SITE PLAN 4 GRADING AND DRAINAGE PLAN 8 DETAILS & CONDITIONS OF APPROVAL 7 DRAINAGE DETAILS 8 UTILITY DETAILS 9 TREE PROTECTION PLAN Ll LANDSCAPE PLAN LEGAL DESCRIPTION: COMMENCE AT THE NORTHWEST CORNER OF THE NORTHEAST 1/4 OF SECTION 8, TOWNSHIP 22 SOUTH, RANGE 28 EAST, ORANGE COUNTY, FLORIDA; THENCE RUN S.00o56'08"E. ALONG THE WEST LINE OF SAID NORTHEAST 1/4, A DISTANCE OF 1233.04 FEET TO THE NORTH LINE OF THE SOUTHWEST 1/4 OF THE NORTHEAST 1/4 OF SAID SECTION 8; THENCE RUN N.89m33'16"E. ALONG SAID NORTH LINE 25.00 FEET TO THE POINT OF BEGINNING; THENCE CONTINUE N.89m33'16"E. AND ALONG SAID NORTH LINE 565.40 FEET TO THE EAST LINE OF THE WEST 590.4 FEET OF THE SOUTHWEST 1/4 OF THE NORTHEAST 1/4 OF SAID SECTION 8; THENCE RUN S.00o56'08"E. ALONG SAID EAST LINE, A DISTANCE OF 295.20 FEET; THENCE RUN S.89o33'16"W. 363.30 FEET; THENCE RUN N.00o56'08"W. 91.70 FEET; THENCE RUN S.89o33'16"W. 202.10 FEET TO A POINT LYING 25.00 FEET EAST OF THE AFOREASAID WEST LINE OF THE NORTHEAST 1/4 OF SECTION 8; THENCE RUN N.00o56'08"W. PARALLEL WITH SAID WEST LINE 203.50 FEET TO THE POINT OF BEGINNING. - L7 L7 CITY OF 0 COn..,n OCTOBER., 2003 DEVELOPER - APPLICANT MUNIAN DEVELOPMENTS, INC. 7421 CLARCONA ROAD ORLANDO, FLORIDA 32818 407-296-2002 OWNER FRANKEN PROPERTIES, JV. 8609 • : PARK ORLANDO, FLORIDA 407-578-5830 ENGINEER PECHT-EVANS ENGINEERING, INC. 501 EAST JACKSON STREET, SUITE 202 ORLANDO, FLORIDA 32801 (407)872-1515 SURVEYOR SWAGGERTY LAND SURVEYING, INC. 1450 KASTNER PLACE, SUITE 100 SANFORD, FLORIDA 32772 407-322-4630 GEOTIECH ANDREYEV ENGINEERING, INC. 4500 ORANGE BOULEVARD SANFORD, FLORIDA 32771 407-330-7763 pfOPECHT NEEVANS f MEMENGINEERING, INC.( 501 EAST JACKSON ST. STE. 202 ORLANDO, FLORIDA 32801 (407) 872-1516 AUTHORIZATION NO. 00006788 VICINITY MAP N.T.S. WATER: CITY OF OCOEE SEWER: CITY OF OCOEE TELEPHONE: SPRINT ELECTRIC: PROGRESS ENERGY CABLE: TIME WARNER COMMUNICATIONS GAS: 11 PEOPLE'S GAS SYSTEMS ENGINEER'S CERTIFICATION CONSTRUCTION PLANS WERE PREPARED IN ACCORDANCE WITH THE "MANUAL OF UNIFORM MINIMUM STANDARDS FOR DESIGN, CONSTRUCTION AND MAINTENANCE FOR STREETS AND HIGHWAYS, STATE OF FLORIDA" (FDOT GREEN BOOK) AND ORANGE COUNTY REGULATIONS AND SPECIFICATIONS. i 0 G� CLARCONA—OC OEE ROAD w w O U w O a ti a z Z NICOLE BOULEVARD o Q . z MARL NE DRIVE NORTHERN co DURANGO 1 BOB SITE to w SORENSEON LANE Qf WURST ROAD w I Z vi z o Q Q wcd o Q � Y O Q Y Q J v w U U C� SILVER STAR ROAD VICINITY MAP N.T.S. WATER: CITY OF OCOEE SEWER: CITY OF OCOEE TELEPHONE: SPRINT ELECTRIC: PROGRESS ENERGY CABLE: TIME WARNER COMMUNICATIONS GAS: 11 PEOPLE'S GAS SYSTEMS ENGINEER'S CERTIFICATION CONSTRUCTION PLANS WERE PREPARED IN ACCORDANCE WITH THE "MANUAL OF UNIFORM MINIMUM STANDARDS FOR DESIGN, CONSTRUCTION AND MAINTENANCE FOR STREETS AND HIGHWAYS, STATE OF FLORIDA" (FDOT GREEN BOOK) AND ORANGE COUNTY REGULATIONS AND SPECIFICATIONS. r r APO 1 200 i w a ti Z . z co to vi a wcd a. 0 v o r r APO 1 200 - NORTH 1/4 CORNER OF ScCilal\E 8_22_28 1f (REC. N.&D. IN PAVEMENT CUT-OUT) { BYP+iC T STORM M.ANHOLF N. RIM=168.90 INV.=157.4:? SANITARY SEWER - ` � � . MANHOLE 52 -CVP N. Rttt=SG8.30 IkJOUH LINEOF ;HE N.E•1.1 OF S_- INLV = 157.49 -, `ti F-1, � 1 t Cs 1 t TAX S guy a c t 1 I co va <a E �WOFENCE Platted) 0f�7 . R-3 MULTIFAMILY CHAIN LINK (No' ?atIi, wa FENCE L 1S L- { i 1 L. b't PJ.V;l. CORNER OF THE S.'N.5 j4 OF THE ••`--_ _ _.._ r { - N.E.1!`4 OF SECTION 8-22-2Fs { 3 F 1 F REC.N,&D. (LS.1263) ALSO REC, N,& - .. _c .,, � , __..., .- 1V0R?-,-t 1.11\++,: {,: ;ti>* S.t'% 9 '� OF i� Eu.E.1! G= S_ ';^;; `y -''i (,L.a,1993) 0,09 S. AND 0.20 E. { ;, R5P3fAL7 � � � END OF FENCE ( DRIVE I tr f N 89033'1 CE 590.40' 1100D POWER I t -•r i <a .. POET (;Yp) \4 ( Cl' `:e' rs m 'r'' 11 ,,4• ,tJ' '__ it TELEPHONE RISER o,i} Cit { v ;y��+.o,�" 145 "+�' ✓ p�F• .,y;� i3, _ , . 1 i + {} C�1 i 4>t, ;� ,C•i- ,,'� H:� n ,< ' {}i3�� CONCR Eco � 'SCI" iJl I { f l 1 f �r DRIVE ij I � � /�� j�sss ^j� `\�` ^1'J •.,�Y' :t L t� ll R-1 `EN } { SINGLE FAMILY RESIDENTIA 1 C.E. MAILBOX ? & PLANTER E C±07 107 3 f: , t o i Pi •�/1l`'Y-es Vi+#,a 1' '� t�+. ya•. 4"' 1 IVO { FATE? It ! fiI Q i;'' �}• ',' { (u3 GR c i LO3 ` G' G vi ��•`.' a!�:-c.�5',J?s.s .�,r,iaaa�1M�7 ' ;,�+• F� f �7oG1�• , 00 GN04 P FIRE HYDRANT g J�1e GV SANITARY SEWER F MANHOLE hQLtGNT POLE `vim GCONC. SIREET _ N. Y On LLJ N+.NV.=FA 0 LO �WATER VALVE G: t} rr. Q) f i j iE ' j Q 2' I1,LtuMI { I 11 p a t a s_ CUAN F.E , ECS 1o� & k` / } 9 L7 PG•* '2 2 ,�Cy .t .` `+• ' .�"\� y",`,'U :`A`0"V r -•--^...-._.i- t ....._ r'1SPF1ALi t a P crs ! 9 1 11 n ?' • ,x! ^t, G K�.y.. 3, l PAVEMENT ( u aC' >r rsC3' {# Com`{ ,J -1 NORTHERN T o-^ -t - 3 j _ f i jr to ;�� `f �(' i o'�G G P 't D 'V RA N S..H `v= � { f �„ / � �p �a,�{'I' a. ,C`� 4 c,�� „� �I M fl t 1 2` 'h1A,4i! '` 5l i' { 4 4 lfG 1& 1 Ei' � • 3 fr r• as VE i� T+' CURE �' U 3 x iii ��1 t t /�i t i$ .53L \� aCf' r�� r,• 00'% R {`,` E -167,51 \! t SITE BFNC H ItARK 1 V! t r / at T_ t { t 6 .$Ii 1 z Sia' (�• 6 pmt' iu ' ELEVATION 168.95 Ns NORTH RIM OF SAN37ARY T?fVOVR,57.9A9NHOLE ' SEINER MANHOLE LV� Eaf,qqhOr R04=963.53 y ia 0. >N c2 �� 1 8,35 AN.&S / 554.98 { _ 3 +- ri E,:7�8' 'VVi0E ROUGH A P A_T RATER 6 ri�R tia>a�-' ✓;n' y 6,U�•^ � i r i25 MPH SPIED va,tJ tz7c 6' 0' c` 1/ l Mf (hCa }5' LIMIT S!sld "yi4r7 �Fl WOOD j ?7 61 ? ��i � �' � ' 1d.r3Sai3'16 C 2Q5.?}C2' \ �\ n SHED � ON-LtPj ��,/// 7f /.r y cA t SET a; E"1.R. 1 kr � i '1 �•�,, t...... U I ! ( 2- i' (EAST D.�Y �{T4 35 8 i5 (L.S.3764) IES F I 1 1668 80-8.37 f$ 1 PARCEL S 89ra3316 W / 227.10f r a) i f 1521.5 i SQ. FFc? " •--�" (L.5.2.^c8a) ��. POINT OF REG `4lfi�i r 0 ! h•+1 w ALSO REI. 9 1j2"1.P.EPSO j o - FOR LESS OU %111 1 -1 � 04 it �! -CHAIN LINK 1 ENCE 1.9' VIEST ;✓., REC. N.&D. (L.&I263) 1 rr�g ! !! �m r (TYPICAL) T LESS OUT PARCEL, 023 ��~ RSm I ' 11 bu-1 (1 i �% Platted) �co Lo \ m ti..y L`a ' r,. SOIL TYPES ® BASS I NGER GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch { I 1 •� � �.:� SITE BENCHMARK #2 f FLEIVATIOIN 967.89 TOP OF 4" x 4" C.M. 41� 1tJ�4 \CO�b s' t l • I -FENCE: CORMSP 0.5'S. & N Z �3 • ri 1�` ave Ft ' 0 CC -41 00 e ® «i x s ao o =cm LLj W 01. Q z i' 00 SOIL TYPES ® BASS I NGER GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch { I 1 •� � �.:� SITE BENCHMARK #2 f FLEIVATIOIN 967.89 TOP OF 4" x 4" C.M. 41� 1tJ�4 \CO�b s' t l • I -FENCE: CORMSP 0.5'S. & ■ N Z �3 N CC -41 00 e ® «i x s ao o =cm LLj W a Q z i' 00 10 d ®_ Q , ,rc+sr. ce 9 � fr Si (!3j U R- Ag 0 01 �� r F L4mJ ® v Z 0 ti W 'C CC i l O r Ci L9: Lm 10 Na v 4 G: c 4G' mfr .,v ■ :C`., R-1 ORANGE COUNTY I .. Q , SINGLE FAM l � o�h�t 1�,,•�•• Gars y I (WEST i D. t h { d._ 5,89o33''i6"W. 245.00' M. /' 7.E`�„ '�S�M �a 1 � h2 iW s4 1 y� s y C} a Sr 569.3 t .__� ._____.- - t �._. '` on.153.2 •`, 3 ;x � . ,3rv^.,�r•, t „ 1i i \tom t, *: 1 % �. `•- ,s \ ,\� .z G k. REC, 4.6d. (L.S.12o SET 5 L`i R- G » r ` S 4'X4 LS, i E I1 ��'' s 75- r°` ' t _ °, ,. :.x. A. S 89;x3316 W 363.30 _'" j�., .(L,s. Y _ ,:: �� L� r ..Ji..i t s ,. _ s t) „7 1 aOF''�,'S;»rye""'_`.-,._......__.'%4{�cra�._..._._._. ;'._._._......._.._...._...__.__"_,_-,�..'__._..__l.._„_._.--------- t-..., ; 3-•T ray f 2,g1.7� "F.(7c�iS0v:fi . gam, p ,C; C'1 3 { . � .f- Y ii li ca { � €� tTi trr x- ....__..__. "' - p ALSi r REC. i < I.r �' \.R-1 ORANGE COUNTY �^.✓ t { PEC:4`i.4 t�'" i`t-1E_ ',-. S . {E zALSO'' + __- , t-•, r 1:. !' -•P=; '; 5;4'C�' Vit; t"S!- .1-tF. (v...�,.]�� D t A > REt:,1 -_VAI�L'•11`1'T'• RE ID t i (Not, Matte }: ___ _l art 1.'_�_ .t>: ' :.:,/,", S ENTIAL Platted) _- x _ ?'l< c?: C.2°Eis. It 'i 1.1 r' L r;,: e { t i.; 2-..',2 - 1 { 1 ?c CHAIN LINE; FENCE (TYPICAL) 1 i l� cu C) o �1 N Z �3 N CC -41 00 e ® C%j z_ :C`., R-1 ORANGE COUNTY I .. Q , SINGLE FAM l � o�h�t 1�,,•�•• Gars y I (WEST i D. t h { d._ 5,89o33''i6"W. 245.00' M. /' 7.E`�„ '�S�M �a 1 � h2 iW s4 1 y� s y C} a Sr 569.3 t .__� ._____.- - t �._. '` on.153.2 •`, 3 ;x � . ,3rv^.,�r•, t „ 1i i \tom t, *: 1 % �. `•- ,s \ ,\� .z G k. REC, 4.6d. (L.S.12o SET 5 L`i R- G » r ` S 4'X4 LS, i E I1 ��'' s 75- r°` ' t _ °, ,. :.x. A. S 89;x3316 W 363.30 _'" j�., .(L,s. Y _ ,:: �� L� r ..Ji..i t s ,. _ s t) „7 1 aOF''�,'S;»rye""'_`.-,._......__.'%4{�cra�._..._._._. ;'._._._......._.._...._...__.__"_,_-,�..'__._..__l.._„_._.--------- t-..., ; 3-•T ray f 2,g1.7� "F.(7c�iS0v:fi . gam, p ,C; C'1 3 { . � .f- Y ii li ca { � €� tTi trr x- ....__..__. "' - p ALSi r REC. i < I.r �' \.R-1 ORANGE COUNTY �^.✓ t { PEC:4`i.4 t�'" i`t-1E_ ',-. S . {E zALSO'' + __- , t-•, r 1:. !' -•P=; '; 5;4'C�' Vit; t"S!- .1-tF. (v...�,.]�� D t A > REt:,1 -_VAI�L'•11`1'T'• RE ID t i (Not, Matte }: ___ _l art 1.'_�_ .t>: ' :.:,/,", S ENTIAL Platted) _- x _ ?'l< c?: C.2°Eis. It 'i 1.1 r' L r;,: e { t i.; 2-..',2 - 1 { 1 ?c CHAIN LINE; FENCE (TYPICAL) 1 i l� cu C) o �1 :n.-+.; - 6%.:,c-5t3f>.86 8 ,J,> 9Fs9.04 5a"8.78-' f i i J� /`,, PARCEL j �,tl 5 - 68 �� - _.... c .o_ _.__..__..--.._------ 8,510 . :.x.65 ci..�- 68.83 16&74- 'X�- ''- { (, .?1 t afia�t ii a (j L7m.45 1 1' ^ ^.5i` ~., ri'it ' ;� �•r. rn 1 s t ASPHALT PAVEMENT _ r 4T CUIl 1RL= ;c 4 STORM MANHOL1 ����� Platted) �E-- <s• - N. RIM=168.21 68.21 } INV.=160.5 3 -LBO { LB®B®RNs®N LANE a I R-1 NON AGRICULTURAL y189,60 .�n 6 N Z O N CC -41 00 e ® C%j z_ ao o =cm LLj W a Q z i' 00 10 d ®_ Q ce 9 � fr Si (!3j U jr4. 40 rL,LII ONO 0 01 �� r F L4mJ ® v Z 0 ti W 'C CC V. 0 O L9: Lm 10 :n.-+.; - 6%.:,c-5t3f>.86 8 ,J,> 9Fs9.04 5a"8.78-' f i i J� /`,, PARCEL j �,tl 5 - 68 �� - _.... c .o_ _.__..__..--.._------ 8,510 . :.x.65 ci..�- 68.83 16&74- 'X�- ''- { (, .?1 t afia�t ii a (j L7m.45 1 1' ^ ^.5i` ~., ri'it ' ;� �•r. rn 1 s t ASPHALT PAVEMENT _ r 4T CUIl 1RL= ;c 4 STORM MANHOL1 ����� Platted) �E-- <s• - N. RIM=168.21 68.21 } INV.=160.5 3 -LBO { LB®B®RNs®N LANE a I R-1 NON AGRICULTURAL y189,60 .�n 6 U N Z O CC -41 00 e ® C%j z_ ao o =cm LLj y�� �/ a Q z i' 10 d ®_ toz ce 9 � fr v (!3j U jr4. 40 rL,LII ONO 0 o F U N Z O 000 N e ® �0 z_ ao o =cm LLj y�� �/ Qi✓i Q z i' 10 ®_ toz 9 ®N CC O U W (!3j U jr4. 40 rL,LII ONO L4mJ ® v Z 0.4 W 'C CC V. 0 O L9: Lm 10 0 Q 3f ii. z OCIO �? ®.e Z Z, (A IL J _ 0 z IL 0. iD DRAWN: ET CHECKED: TT DATE: OCTOBER 200$ SCALE: °I If -$0' CAD NAME: SURVEY JOB #: 11004 SHEET #: OF 9 SHEETS WAIVER TABLE 0 WAIVER REQUEST 1 I I I TAX PARCEL 013 I (Not Platted) j CHAIN LINK — FENCE � 1 IJ / ASPHALT II DRIVE ' CONCRETE DRIVE II I I I I LOT 62 R-1 lo) SINGLE FAMILY RESIDENTIAL ISI Izl I II OR J 1 - WOOD FENCE j E TAX PARCEL 071 (Not Platted) R-3 MULTIFAMILY SITE DATA PARCEL ID: 08-22-28-0000-00-042 PROPOSED ZONING: R-1 LANDUSE: RESIDENTIAL (SINGLE-FAMILY) MINIMUM LOT AREA: 7,000 FT MINIMUM LOT WIDTH: 70 FT MINIMUM LIVING AREA: 1,000 FT DENSITY: NO. OF UNITS - 11 GROSS AREA - 3.52 UNITS/ACRE - 3.13 AREA CALCULATIONS: TOTAL PARCEL AREA - 3.52 ACRES STREETS AREA - 0.05 ACRES NO WETLANDS OR 100 YEAR FLOOD PLAIN ON SITE 92111101001M.121109 • MAX IMPERVIOUS - SECTION SUBSECTION CODE STANDARD PROPOSED STANDARD JUSTIFICATION ARTICLE VI 6-9 A RECREATIONAL AMENITIES FOR SUDIVISION WITH 10 - 50 LOTS 1 AMENITY 5' SIDEWALK TO CONNECT PROPERTY WITH ADJACENT PARK IN LIEU OF RECREATIONAL AMENITIES ACCESS WILL BE PROVIDED TO EXISTING ADJACENT RECREATIONAL FACILITIES 25 FT SIDE - SUBDIVISION STANDARDS FT REAR - I I I TAX PARCEL 013 I (Not Platted) j CHAIN LINK — FENCE � 1 IJ / ASPHALT II DRIVE ' CONCRETE DRIVE II I I I I LOT 62 R-1 lo) SINGLE FAMILY RESIDENTIAL ISI Izl I II OR J 1 - WOOD FENCE j E TAX PARCEL 071 (Not Platted) R-3 MULTIFAMILY SITE DATA PARCEL ID: 08-22-28-0000-00-042 PROPOSED ZONING: R-1 LANDUSE: RESIDENTIAL (SINGLE-FAMILY) MINIMUM LOT AREA: 7,000 FT MINIMUM LOT WIDTH: 70 FT MINIMUM LIVING AREA: 1,000 FT DENSITY: NO. OF UNITS - 11 GROSS AREA - 3.52 UNITS/ACRE - 3.13 AREA CALCULATIONS: TOTAL PARCEL AREA - 3.52 ACRES STREETS AREA - 0.05 ACRES NO WETLANDS OR 100 YEAR FLOOD PLAIN ON SITE 92111101001M.121109 • MAX IMPERVIOUS - 50 (coco MAX BUILDING COVERAGE: 40 ® LINEAR FEET STREET: 440 FT BUILDING SETBACKS: N FRONT - 25 FT SIDE - 7.5 FT REAR - 25 FT FROM ADAIR STREET - 35 FT MAX BUILDING HEIGHT: 35 FT EXISTING VEGETATION TREE/ COVER OAKS TREE ARE APPROXIMATELY 60% WC TREES ARE APPROXIMATELY 30% PINE TREES ARE APPROXIMATELY 10% 25' OF ROAD R/W PREVIOUSLY DEDICATED TO THE CITY OF OCOEE END f t NO FENCE 5' CONC S/W N 89ra3316» E ' 590.40 70.00' 70.00' 117.8$' 97.50' 70.00' 70.00' 70.00 10' WALL, LANDSCAPE & SIGN EASEMENT co 6' BRICK WALL i ! Iv N n41 cn 85.42' I_ _.....__.. .___. 4' CONC S/W 25' SIGHT TRIANGLE SITE BENCHMARK ;C2 ELEVATION 167,81 _ TDP Or 4" X C.M. (hlCr FRIJOE CORNER D.S'S. &c 0.35'F. v V 1 0) T CHAIN LINK FENCE 4 (TYPICAL) i 3� GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. QHANDICAP RAMPS ��• rn 70.00' 70.00' 70.00 21.92 8 1 — J 72.72' 70.00';777 ; I I /1 4 N 2' MIAMI I I 12+00 00 13+00 N di ' cuRe 9.1.16.09 10-00 I �o q o NORTHERN DURANGO AVENUE ASPHALT I .°- 10' WAIL, LANDSCAPE, STREET A `rLr 79.80' 0c) � PAVEMENT r AND SIGN EASEMENT c0 W ° N 0 2MIAMI CURB70.0o' cTO BE REMOVED cOO SITE BENCHMARK #1 � I �w N } v � � ELEV4TIC,�I 16.3a _/ I a ¢ ° ; / A POND 2 4' CONC S/W QQuI �� I o 1 .44 NORTH RIM OF SANITARY SEWER MANHOLE (0.19 ) (NOTE: S/W ALONG DRAINAGE � TRACT A ac TRACT TO BE CONSTRUCTED ' o 5' CONC S/W 1 I I 2' WIDE ou H ASPHALT ---r� BY DEVELOPER) 6' BRIC WALL o ID w �99.31' WOO�E,vcE R-1 3SHEON—LINE Z II yow Y 1 1 x02' 59;° NON AGRICULTURAL I� F.- 1 S 89033'16"W 202.10Q CSL"A"y ^I QG W I I i 0 ; 4' CONC S/W j I I 1 I III uHAIN LINK FENCE r I: (NOTE: S/W ALONG DRAINAGE ' I Ld 1 1 I ®� III (TYPICAL) LESS OUT ,{-- — _-_ .----._--- ....._.. , TRACT TO BE CONSTRUCTED i I } POND 1 BY DEVELOPER) 10 + I i I 40 1 II TAX PARCEL 023TRACT B (0.40 ac) o I O I ° C:1 I I IINot Platted) ^4 ( I II O I i I I i R-1 ORANGE COUNTY 1 - ---- --- -- - E SINGLE FAMILY RESIDENTIAL z ` 1 I I I I 7.&' 122.52' I I 1 9,3 , II FENCE TO BE RELOCATED S 89�n33'16"W 363.30' I i I TAX PARCEL 076 ALONG PROPERTY=' -'� R-1 ORANGE COUNTY 1 BOUNDARY II (Not Platted) —___ ;:-.- r VACANT RESIDENTIAL 1----- -- =7 =7 I I BOB SORENSON LANE TAX PARCEL 081 i ASPHALT PAVEMENT �1' FEAT CONCRETE CURB (TYP.) — — — — — 1 II I ( I I II II I I II i it m C.7 W (coco z ® M CID, O N MM B/ .N- p O aO � Q M W IcCJ � La..1 N Lj W U O 0 Ld G" ® W W 0 � U>� Lt..l W en O � 0) W F Q MEN V DRAWN: ET CHECKED: TT DATE: OCTOBER 2003 SCALE: 1"-s®' CAD NAME: SITE PLAN JOB #: 11004 SHEET #: EL OF 9 SHEETS N (coco z ® o00 N Z v W aO � Q io La..1 N Lj 1- Ld G" ® 0 0 � DRAWN: ET CHECKED: TT DATE: OCTOBER 2003 SCALE: 1"-s®' CAD NAME: SITE PLAN JOB #: 11004 SHEET #: EL OF 9 SHEETS N z ® o00 N Z v W aO O O y Q z La..1 Z 1- to c/ -)C5 ® vm ! z IcN U>� Lt..l ® O � 0) j w ®0 MEN V L4J Z L4JIC Q j r O .00 DRAWN: ET CHECKED: TT DATE: OCTOBER 2003 SCALE: 1"-s®' CAD NAME: SITE PLAN JOB #: 11004 SHEET #: EL OF 9 SHEETS .i' DRAWN: ET CHECKED: TT DATE: OCTOBER 2003 SCALE: 1"-s®' CAD NAME: SITE PLAN JOB #: 11004 SHEET #: EL OF 9 SHEETS PAVING & DRAINAGE NOTES 0 EROSION CONTROL GENERAL NOTES 1. ELEVATIONS AT CURB ARE EDGE OF PAVEMENT GRADES. 1. ALL EROSION/SEDIMENT CONTROL MEASURES SHALL COMPLY WITH STATE AND GENERAL CONSTRUCTION NOTES LOCAL SOIL EROSION CONTROL AND CONSERVATION STANDARDS. ADDITIONAL LEGEND 41\1 MEASURES TO PREVENT/CONTROL SOIL SEDIMENTATION OR EROSION MAY BE 1. PRIOR TO COMMENCEMENT, CONTRACTOR SHALL PROVIDE PECHT-EVANS ENGINEERING, INC. o, ti 0 2. THE MINIMUM ROADWAY GRADE SHALL BE 0.307. REQUIRED DUE TO SITE CONSIDERATIONS WITHIN THE BOUNDARY LIMITS AND WITH CONSTRUCTION SCHEDULE FOR VARIOUS SITE WORK ELEMENTS SO THAT PERIODIC TO yv _���% DOWNSTREAM. SITE VISITS MAY BE COORDINATED TO INSURE TIMELY CERTIFICATION OF CONSTRUCTION�Q 5 J17 3. MINIMUM GRADE OF SODDED DRAINAGE WAYS TO BE 1%. #'s'`�, �� 2. PRIOR TO DEVELOPMENT, PERIMETER SHALL BE CLEARLY MARKED AND ALL SOIL g 1 ?:: > Al ECTION ID ATES OF OCGJPAN CY. a DELAYS IN ISSUANCE OF ERTIFIC �. AGENCIES AND TO AVOID DEL ����� ti A ti T DISTURBANCE TO BE CON AINED WITHIN. OFF SITE 0 � '>:: ,� �'. •. W RK MAY BE NECESSARY i TOR TO ASSURE PONDS ARE SODDED � CONTRACTOR WITH LANDSCAPE 0 4. COORDINATION TH DUE TO ACTUAL SITE SLOPE OR DRAINAGE REQUIREMENTS. ALL CONTROL 4 � PREVENT SCOURING. - AS -BUILT o TO P U P WITH MARKED -UP S T OF PLANS ACCURATELY M --.� r �">'><';��`?>:>'��:�'�s��'<'�::�:: MEASURES MUST CONFORM TO SITE STANDARDS. SHEET REFERENCE 2. CONTRACTOR SHALL MAINTAIN A SE �` INFORMATION ON RIM AND INVERT ELEVATIONS. AS -BUILT INFORMATION PREPARED BY A REGISTERED ' DARD LAND SURVEYOR IN ACCORDANCE WITH THE CITY OF OCOEE LAND DEVELOPMENT REQUIREMENTS SHALL ¢ SISLOPE 4 ��� ��� y�` 5. F.D.O.T. INDEX NO. 102 AND 103 SHALL BE USED FOR EROSION AND SEDIMENT 3. ALL POINTS OF SITE INGRESS AND EGRESS TO BE CONSTRUCTED PRIOR TO ANY a CONTROL. BEST MANAGEMENT PRACTICES AS REQUIRED BY THE CITY OF OCOEE OTHER DEVELOPMENT. THEY MUST BE STABILIZED AND INCLUDE SOIL EROSION/ BE SUBMITTED TO THE ENGINEER PRIOR TO FINAL ACCEPTANCE OF THE WORK. Sri SygLE �+ SHALL BE OBSERVED. SEDIMENTATION CONTROL MEASURES IN ORDER TO PREVENT TRACKING AND S-1 STORM STRUCTURE NUMBER 3. REGULATORY SIGNS SHALL BE IN PLACE PRIOR TO FINAL INSPECTION OF PAVING AND DRAINAGE SILTING OF MUD INTO PUBLIC ROADWAYS OR DRAINAGE AREAS TO BE 6. SITE GRADING PAVING, AND DRAINAGE MATERIALS AND CONSTRUCTION SHALL IMMEDIATELY REMOVED. p IMPROVEMENTS. CONFORM TO THE CITY OF OCOEE AND F.D.O.T. DEVELOPMENT STANDARDS���� PROPOSED GRADE � 4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SURVEY MONUMENTATION. AND SPECIFICATIONS. 4. ALL STORM DRAIN AND. SANITARY SEWER TRENCHES NOT IN PAVED AREAS ARE TO BE MULCHED AND/OR SEEDED WITHIN 14 DAYS AFTER INITIAL BACKFILL. GRAPHIC SCALE DISTURBED MONUMENTATION SHALL BE RESTORED BY A FLORIDA -LICENSED LAND SURVEYOR 7. IT WILL BE THE RESPONSIBILITY OF THE CONTRACTOR(S) TO INSURE THAT ALL 5. DURING CONSTRUCTION, ALL SEDIMENT CONTROL STRUCTURES WILL BE INSPECTED PROPOSED FINISHED FLOOR ELEVATION SELECTED BY THE OWNER AT CONTRACTORS EXPENSE. REQUIRED PERMITS ARE OBTAINED AND ARE IN HAND PRIOR TO THE AFTER EACH RAINFALL AND REPAIRED IF NECESSARY. SEDIMENT TO BE REMOVED 3 1 0 0 15 30 60 TYPE '�i� LOT GRADING 5. CONTRACTOR IS RESPONSIBLE FOR GRADING ALL ROADWAYS TO DRAIN POSITIVELY. INTERSECTIONS COMMENCEMENT OF CONSTRUCTION. TO A SUITABLE DISPOSAL AREA AND STABILIZED WITH PERMANENT VEGETATIVE 171. A COVER. SHALL BE TRANSITIONED TO PROVIDE SMOOTH DRIVING SURFACE WHILE MAINTAINING POSITIVE DRAINAGE TO STREET PROPOSED LOT GRADING TYPE DRAINAGE. SHOULD AREAS OF POOR DRAINAGE RESULT FROM THE ADJUSTMENTS DESCRIBED, THE N.T.S. 8. THE STORM WATER RETENTION/DETENTION PONDS SHALL BE CONSTRUCTED 6. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL SEDIMENT AND EROSION CONTRACTOR SHALL NOTIFY THE SITE SUPERINTENDENT PRIOR TO PLACING BASE SO THAT DURING THE EARLY STAGES OF CONSTRUCTION. SODDED AND/OR SEEDED CONTROL MEASURES UNTIL DISTURBED AREAS ARE STABILIZED. ( IN FEET ) RECOMMENDATIONS FOR CORRECTION MAYBE MADE. AREAS SHOULD HAVE VEGETATION ADDED AS SOON AS FEASIBLE. �� DRAINAGE FLOW ARROW 1 inch = 30 ft. 7. AFTER FINE GRADING, ALL DISTURBED AREAS ARE TO BE PERMANENTLY MULCHED 6. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY DISCREPANCIES FOUND 9. SOILS INFORMATION WAS PROVIDED TO PECHT-EVANS ENGINEERING, INC. BY AND/OR SODDED. BETWEEN THESE PLANS AND THE FIELD CONDITIONS PRIOR TO CONSTRUCTION. YOVAISH ENGINEERING SCIENCES, INC. B. NO SLOPE SHALL BE GREATER THAN 2:1. 7. CHAPTER 17-153 OF THE FLORIDA STATUES REQUIRES THAT AN EXCAVATOR NOTIFY ALL GAS 10. ALL CONCRETE PIPE JOINTS SHALL BE WRAPPED WITH FILTER FABRIC PER 9. FOLLOWING INITIAL SOIL DISTURBANCE, PERMANENT OR TEMPORARY STABILIZATION SHALL BE COMPLETED WITHIN SEVEN CALENDAR DAYS AS TO THE SURFACE OF ALL UTILITIES A MINIMUM OF TWO WORKING DAYS PRIOR TO EXCAVATING. DRAWINGS SHOW ONLY THE CpPVC STORM MANHOLE FDOT INDEX #280. PERIMETER CONTROLS, DIKES, SWALES, DITCHES, PERIMETER SLOPES, AND ALL APPROXIMATE LOCATION OF GAS MAINS AND DO NOT SHOW SERVICE LINES. THE ONLY SAFE AND N. RIM=168.90 ( SLOPES GREATER THAN 3:1; AND FOURTEEN DAYS AS TO ALL OTHER DISTURBED PROPER WAY TO LOCATE EITHER MAINS OR SERVICE LINES IS BY ON-SITE INSPECTION BY GAS J� -"1!- Z52-CMP NV.=157.49 11. AS -BUILT INFORMATION- OR GRADED AREAS ON THE PROJECT SITE. THIS DOES NOT APPLY TO THOSE AREAS COMPANY PERSONNEL. THEREFORE, EXCAVATORS ARE INSTRUCTED TO TELEPHONE THE GAS SANITARY S_FVS�Et AS -BUILT DRAWINGS WILL BE REQUIRED WITH THE FOLLOWING INFORMATION: WHICH ARE SHOWN ON THE PLAN AND ARE CURRENTLY BEING PERFORMED. COMPANY TWO WORKING DAYS BEFORE ENTERING A NEW CONSTRUCTION AREA. MANHOLE t MAINTENANCE SHALL BE PERFORMED AS NECESSARY TO ENSURE THAT STABILIZED N. RIM=168.94 } A) STORM DRAINAGE AREAS CONTINUOUSLY MEET THE APPROPRIATE REQUIREMENTS OF GOVERNING 8. ALL PAVEMENT RETURN RADII SHALL BE MEASURED FROM THE EDGE OF PAVEMENT UNLESS 1��`E=�s7.49 _ 1. TOP ELEVATION OF EACH MANHOLE FRAME AND COVER/GRATE AS WELL AS AUTHORITIES. OTHERWISE NOTED. IR ALL OTHER STRUCTURES (HEADWALLS, CONTROL STRUCTURES, ETC.). 10. SILT FENCED TO BE PLACED AROUND PERIMETER OF PROPERTY AS SHOWN. I' -e,� 2. INVERT ELEVATION OF EACH LINE ENTERING AND LEAVING EACH STRUCTURE, / 11. EROSION CONTROL MEASURES WILL BE MAINTAINED AT ALL TIMES. ADDITIONAL 9. ALL DISTURBED AREAS SHALL BE RETURNED TO PRECONSTRUCTION CONDITIONS, OR BETTER. 4 INCLUDING UNDERDRAIN PIPES. III j � '•`"-76 3. INVERTS OF ALL MITERED END SECTIONS. EROSION AND SEDIMENTATION CONTROL MEASURES WILL BE INSTALLED IF DEEMED 10. ALL PAVEMENT MARKERS, STRIPING, SIGNAGE, AND OTHER TRAFFIC CONTROL DEVICES TO BE I jj p / `g 0 4. ACTUAL GRADE OF PIPE BETWEEN THE STRUCTURES. NECESSARY BY ON-SITE INSPECTION. INSTALLED BY CONTRACTOR PER F.D.O.T AND THE CITY OF OCOEE STANDARDS. 1 5,.•, INVERT ELEVATION AND TWO HORIZONTAL TIES FROM PERMANENT VISIBLE 12. THE INSTALLATION OF EROSION CONTROL MEASURES AND PRACTICES SHALL 1 II OBUES•TS TO ALL STORM STUB -OUTS. OCCUR PRIOR TO OR CONCURRENT WITH LAND -DISTURBING ACTIVITIES. 11. THE FOLLOWING AGENCIES AND COMPANIES SHALL BE NOTIFIED 48 HOURS PRIOR TO BEGINNING CONSTRUCTION: I 1 12 THE DENSITIES AT UTILITY AN9_.5TORM STRUCTURES (LOCATED WITHIN ROADWAY A. THE CITY OF OCOEE ENGINEERING DEPT. TAX PARCEL 013 l i TO 3 -FEET BEHIND THE CURB) SHAD -B� 98% WITHIN PAVEMENT AREAS, AND B. ORANGE COUNTY PUBLIC UTILITIES I 95% FOR STRUCTURES OUTSIDE PAVED ARtRS,--@UT ARE WITHIN THE RIGHT-OF-WAY, C. BELLSOUTH TELEPHONE (Not Platted) I ii el PER AASHTO T-180 MODIFIED. �`�?�0`! TAX PARCEL 071 R-3 D. TIME -WARNER COMMUNICATIONS, INC. J s - E. PROGRESS ENERGY I II 1 `%69 ~� M U LT1 _FA9 SITE BENCHMARK #20-d(Not Platted) 12. CONTRACTOR TO BE EXTREMELY CAUTIOUS WHEN WORKING NEAR TREES WHICH ARE TO I 1i J 114 LEVATf4 167,81BE SAVED. IF THERE IS A QUESTION AS TO WHETHER A PARTICULAR AREA SHOULD BE 1 �`` �^ s `� ` "f' or 4" x d" C.M.C.rs. CLEARED, THE CONTRACTOR SHALL CONTACT THE OWNER FOR FURTHER INSTRUCTIONS. �J as i "'� SILT FENCE (TYP),- -' --- -�` f �.�••... ,.-�'' � --"168.0 13. BOUNDARY AND TOPOGRAPHIC DATA WAS PROVIDED TO PECHT-EVANS ENGINEERING, INC. BYASP SWAGGERTY LAND SURVEYING, INC., DATED 12/11/02 DRIIVET (bO�° 14. THIS PROPERTY LIES IN FLOOD ZONE 'X' PER THE F.E.M.A. FLOOD INSURANCE l-- 1i 1 ( g� �• 'p Orb N 89sn3316 E 590.40 X00 ,�p�' ,- \(OA �-- ,-,� g`l• WOOD POWER -� � i �O � ��O '� .l01' RATE MAP COMMUNITY -PANEL NUMBER 12095C 0210E, DATED DECEMBER 6, 2000. POLE (TYP.)0 Ll 15. ALL MARKINGS TO COMPLY WITH F.D.O.T. ROADWAY AND TRAFFIC DESIGN STANDARDS, TELEPHONE RISER - �E-1 � '�) (1 I 169.0 - - - -- --- `` , --� � + MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES. lb 16. ALL TRAFFIC CONTROL SIGNS AND STRIPES SHALL CONFORM TO THE :M.U.T.C.D. AND I CONCRETE i t4 THE CITY OF OCOEE TRAFFIC STANDARDS. THE INTERSECTION WITH ADAIR STREET I DRIVE y( I a� " -�_---- ---- -- -, 1 SHALL HAVE A 30" HIGH-INTENSITY STOP SIGN AND A 24 THERMO-PLASTIC STOP BAR. I.__ I �� ��L I u') 5' CONS S/W ; �' E 17. FLORIDA POWER CORPORATION SHALL DEVELOP A LIGHTING PLAN DURING THE -I r z�i Ill I I ! ! 1 1 ,�� INFRASTRUCTURE CONSTRUCTION. WO I zN C.a. MAILBOX i o 18. SIDEWALKS SHALL BE BUILT TO BE FLORIDA ACCESSIBILITY CODE COMPLIANT, INCLUDING HANDICAPPED RAMPS. LOT 62 IJ i 1 I 2 3 5 R-1 1 i IN 11 O ° ; SINGLE FAMILY RESIDENTIAL w I 10 I ' ! ' � � � ` I� I 1 Ic L, 172.0 A , , 171.8 A 171.6 A 171.4 A 171.2 A 171. A ; �- `� __. _ ._-- •_-- _ 6�,�ti NATER o f 1 0 ` 1 I 1 I I I �'� IAEttR ! ; U ( ' ` I---- --- --- --- --- -- -._. -.. - .__. •- --- ---- .._ -. -- p. EIRE HYDwurr' - \ i SA 61 SEWER - - i I 1 ��,� 23 LF - 18" 44 4' CONC S/W E 1 HOLE 1 1 i it I '.." RCP 7.39%6 p S-7 ; MANHOLE C01C STREET � 1 N. RtM=148.95 L,crtt POLE I I i p� pg�\ bb I N.8,S.INV.=75c7.os y�f.177V.=la$.E6 --/ I I 41 :d^° d .d- °.d P (�✓• i 4) WATER VALVE/ I 1 O - _ _ _ ° V-169.0 ! O ... . '--_ 171.3 A 2' MIIAMI � I 1\ � ,�, 12+00 0.35% _ 13+00 0 O$�Op I i `� ` rn 0.35 9 6 .09� 10 00 �� �� 1 +00 - ,�h � + CONNECT TO EX TING I _ yPVh I__� - - ��. �6 �`- ��o°'' �g �p o e' ���o�`--��-, W a) MANHOLE ® PAVE ENT --� / Op0°� 68 LF 180 X00 ,� S_5 - ^ ,��4' b0 INV EL 163.0 RCP ® 0.29/ p p 00 '� °y o - ctS - --- i I o� (0 LO EXISTING GROUND _ 2' MIAMI �jI I52"CMP I CURB V\ 1 1 ° B -e e. �� +. r s' .. - I w 172 ` ' ° i O � 172 - -._` (. - - J ry I l p-- d' �t 168.5 S-6 168.5 Nro, p��+ ! 1 i Sfi� t�� fel iIA�I{ i ¢� r f' , in �4 c r # //'! � - - ) I VI � W � � 166.5 167.5 N �0�� 4 CONC S/W f E-- � O EL NATION 168.9-- �_ ✓ I NQ � 1 a OND #2 91 LF - 18 166.0 I 9 � F'' � O i { OND TOB = 168.5 NORTH RIM OF saNt'tkR; ¢ a { 1 / S_g 100Y/24 DHW = 167.58 RCP ®0.55% 165.5 78 LF - 24" 7 1-169.0- I QQ j I ; sEwER n-�NrreLE STORM MANHOLE I i N1011 166.0 - - O RCP ® 0.26% 4 168 --j t1" l I 168 N. RIM= 168.63] _._.. _- ... __.. _.. _._. A /� N.&S.WV.=158.98 I I I II I 167.5 �rOJ+_3 '��$� 171 .`t / I �" 169.20 -'-' W.INV.=157.99 WATER 1 Y 1 168. n I -Z- - - , t;4E EP. Q 1 I �0� O ( 1 4 S/W 25 MPH SPEED ( l ! 45 LF - 24" i I # I_ISAIF SIGN i W rz j ` ! RCP ® 0.36% 10' X 10' pg'� 1._ 164 - ---{ z 1164 I i i 11 \ wood ° ( = 1 Z a yon SHED N ' p 9 RUBBLE RIP d ° 169.10 R-1 1 0 I I oma? ¢ 0 1 "\D'� I °° -J--- f I U�II 1 I 9o33'1 6"W 02.10' RAP NON AGRICULTURAL POND BOTTOM= 166.0 170,3 A NOTE: ESHGWL = 160.5' I _, I 1 SIT FENCE (TYP) I =� 5' CONC S � � S-1 SECTION A2 (POND *2) / i I SCALE: 1" = 30' HORIZONTAL 1 1 I 0 111 ! � .,� LESS OUT -_ ...__..._..-_. __._ __...._....... i 1" = 3' VERTICAL POND #1 i Q 1 100V 24H DHW = 167.58 36 LF - 24" ® I 180 1 i 180 1 1 1 11 *X PARCEL 023 00 RCP ®0.23% ? 1 F I I i I 1 I 1' 1 11 0 5 BERM (TYP) 163.5 i POND GONST�UCTI N NO S (GOTH PONDS): � � I � 1 ( I I�1 �-- 170.0 ,,�(NOt Platted) � � ° -SLOE-1 SIDE _S _SODDED._S0 _ 11 LO 164.5 171.4 A 1 (- !� E TEND OVE BER ( W ' i I I , i� R-1 ORANGE COUNTY ,/ o 166.5 �o - - -- --' - -- - -- - ' lel SEEM AND MULL THE POND BO oM.RY I I I t SINGLE FAMILY RESIDENTIAL ��''' 176 >-- Et 176 I ( ,% Z 167.5 �) I ; I+ i i i $j6 1I -- �Oo I I I 1 ----169.5 -- °'� / 168.5 O , I ' _ ---- E i 172 1 1 I li) ,��4, S 89m3316 W 363.30 172 - - . , , I I I _ --- --fit -.�A EEL- 0 76 169° -- _ _ _ 5' B RM E ISTING GROUND # ( I I 11 - R-1 ORANGE COUNTY ��� IE 1 ( II Not Platted) 5' BERM (TYP) VA�dT-.RESIDENTIAL (-------------- - - ___�_ _______-- ii i _ _ -� PO D TOB! = 16$.5 f -jr-E- 168 i I iI-• - - - - _ - 168` �-._L_ - ____�= --------------------- `_-___1 s I I I I I, 1 I ---1s8.5----- --••168 -----____..--------------- __ _ __ ^�/--�■ _ _ /� _ �\ <S11 I_ I) I ���Q TAX PARCEL 081 r--_'^` �"'_ �. .__..ti_".. -Vi'µ. -. - __..._....__.: -" ASPHALT PAVEMENT -------...__. _._.._._.--1' FLAT CONCRETE CURB (TYP.) __-._......__. --^- BO'�--SO-RENVVN LAAE- ""'^16�,t1 -- ^-•' i _ I \ ii QII `STORM MANHOLE ----�Q-Plalte� - STORM STRUCTURE DATA I I i I I I N. RIM=168.21 164 �-----•-•{� I--- I 1 -B=A3.5"�__-._! I - ` j-� 164 I I i `, i INV.=160.13 Is OTE: ESHG = 160.5 4' S/W �� 11 ( I S-1 S-3 S-5 S-7 MITERED END SECTION MITERED END SECTION STORM MANHOLE CURB INLET, TYPE 2 I I I 1 SECTION Al (POND #1) 1 1 I 13+40.40, 98'R 13+05.63, 54.13'R 11+82.52, 18'R 13+77.30, 14.00'L TOP EL 168.68 I INV EL 163.50 INV EL 163.5 RIM EL 168.90 INV EL 163.80 (S) SCALE: 1" = 30' HORIZONTAL ( I 1 1 INV EL 164.3 (E) 1" = 3' VERTICAL I I I 1 S-2 S-4 INV EL 164.3 (W) 1 I i CURB INLET, TYPE 2 STORM MANHOLE S-8 (� L / ' 13+72.00, 61.75'R 12+76.26, 19.30'R S-6 GRATE INLET, TYPE D TOP EL 168.88 RIM EL 168.80 MITERED END SECTION GRATE 14, 44.74'R 8.05 INV EL 163.60 (N) INV EL 163.80 (S) 11 +81.07, 42.87'R GRATE 1 .20 INV EL 163.60 (S) INV EL 163.80 (W) INV EL 166.00 INV EL 163.20 m W � Z O o00 0000 0 N n NO to co 0 M W 0 0 0 W 00 Z 0 1 N C:, 0 � 0 � u h 9W W Ic � � a t4i _Z ® W O N � cc C2 UW o E= U W � W Z °' O LJ w W a U 0 o 'tea -1 Q O 1_ Z az W fs ® Q � Q U N Z O o00 0000 A N n NO to ■ W [� 0 0 W 00 M I u rn t4i _Z ® a� to a cc C2 UW z O °' O LJ � MEN 'tea -1 Q O 1_ Z u Z U N Z O o00 0000 A N n NO CD Z ■ W [� 0 0 W M ¢z u LLj to _Z ® a� to LZ J cc N UW O O ti O u- � MEN u Z V L4J aJ Lu cc 0CLM`- r� r u r� u u DRAWN: ET CHECKED: TT DATE: OCTOBER 2003 SCALE: 1" -SO' CAD NAME: GRADING PLAN 11004 SHEET #: OF 9 SHEETS I U f CONCRETE } oo - - '-- --- {} I DRIVE } I 1 _- - _ -- - -- _ _ _ _ r - - -- -- - - -- _i 4 .. �'1 66 -7 4` "a :: 110' X 26' OPEN CUT ADgIR TREET I TO CONSTRUCT WATER MANN TO SHALL RESTORE PAVEMENT & PLANTER LOT 62 R_1 SINGLE FAMILY RESIDENTIAL } I} d 2 - 6" 45' BENDS I i ! j j } ' DEFLECT YVATER MAINWATER METER lo} } ) { AROUND INLET I g" PVC -' FIRE HYDRANT ! FIRE HYDRANT SANITARY t ASSEMBLY Ak a ' SANITARY SEWER $" PVC MANHOLE CONC. STREET .:az. 'rr WATERMAIN N. RIM=168.95 LIGHT POLE N.&S.INV.=157.03 v } !j W.INV.=158.86a.d a am d. ! TER VALVE / 1 I �} , .• ,• � .:.- •. .. .. � '. � �`'��;r E 6�,","` ^••..,..,,., a. d +d CONNECT TO EXISTING 2' MIAMI cuRB 1 +00 12+00 j"7 6 ',� VC 10" WATER MAIN 9 6}2.0 1 10 00 13+0 + -_ o - RECL M -E-0 WATTR- LO STREET A ASPHALT } li REDUCED PRESSURE PAVEMENT ZONED BACKFLOW PREVENT 3.; 2' MIAMI �/ \ } }5::... d'° ;d- -. -d '�.. CURB ag .e' 4'.. .�• '.' t .•: o• w. IN +Fin i �-•-, i 4. SITE BENCHMARK 1 \T11, ELEV,�TI(3tJ 1o8.9S1fRECLAIMED WATER LINE �ifio.7 �? ii -�'t ? T-�' - , �.' `' `- \ '..i NORM RIM OF SANITARY � �� _ -.- I � ! � i � � L _ _. � ti `i I ,� I SE44tEfi PIAN TOLE STORM,' MF1 ! ih _E ___ _ - - - - - -- - ; \ 8 PVC r•' R F i } J � � i 66.D } } E -i-- i } ? t t '� _ �- ~1 , `� \ t` s N. . kited="r68.63 'J } } } } J t� DEFLECT RECLAIMED WATER ; < <', 1 11} r } ','� - 1 SANITARY AROUND STORM SEWER } 1 i \ ' �'• �' ^ W.l' 57 } _ _ .�.. '-•--'-c, ,��1T.3>�_._"`--__ Lys ? •V. i .99 WATER METER w . i 25 MPH LIMIT SIGNSPEED o }� WOOD z } r SHE' 0 { fj } } I W\I }} a 1,6 ii } `-, I ; I E t 1 �.` ,'.3 s=f♦yam `� _, �, i i } } }��� e FIRE HYDRANT ASSEMBLY OUT DLECELIMEDATER ; 10 INLET PARCEL 023 ;T(Not Platted) ':..__..._170.0- R- 1 70.0-R-1 ORANGE COUNTY } } } SINGLE FAMILY RESIDENTIAL _ , i NOTE: ALL UTILITES TO BE PLACED WITHIN THE 10' } } ,, } _ _ ----169.5----- EASEMENT ALONG THE FRONT OF EACH LOT SHALL BE PLACED } I AROUND EXISTING TREES TO BETITED PRESERVED.�.,�--�.� .� ..__.-169 0-�---._� R-1 ORANGE COUNTY ._.•---�- ,-'._.-•---..•.�_. __� ---41 .�A.LEL 0'76 16 0 � - --. _ _ } } ( (Not Platted) VAC -A4! -T U31DENTIAL } `SIL---.....�._- }- } ---�-- ---168.5---- _- 168.5 TAX PARCEL 081 169.0--- --- } Il ASPHALT PAVEMENT 1' FLAT CONCRETE CURB (TYP.) - } } } U}ITSTORNI MAINHOL --( 0 N. SIM=r6a.z1 - - - �- N INV.=160.15 174 EX 171 168 CONNECT PROPO EXISTING 10" WN SLEAVE AND VAL 165 E 162 159 ,i ry Tp,� fir} 15gy6 15 5 00 SCALE: HORIZONTAL: 1 " = 30' VERTICAL: 1 "= 3' 9+00 9+50 NOTE: SEE SHEET #4 FOR STORM SEWER INFORMATION. 10+00 10+50 11+00 11+50 12+00 • • 12+50 13+00 13+50 171 168 165 162 159 `tfl rn 10 14+00 14+29.22 UTILITY LEGEND ® SANITARY FLOW DIRECTION ® MANHOLE U SANITARY SERVICE (DOUBLE) T SANITARY SERVICE (SINGLE) _I 90° BEND DA AIR RELEASE VALVE RECLAIMED WATER SERVICE FIRE HYDRANT GATE VALVE I I TEE 0 BLOW -OFF D REDUCER tj WATER SERVICE (DOUBLE) 1 WATER SERVICE (SINGLE) GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. UTILITY NOTES. 1. CONTRACTOR IS TO VERIFY THE LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION IN THEIR VICINITY. 2. WATER MAINS AND SANITARY SEWER GRAVITY MAINS ARE TO HAVE A 10' (MIN.) HORIZONTAL SEPARATION DISTANCE MEASURED FROM EDGE TO EDGE. IF THE HORIZONTAL SEPARATION DISTANCE IS LESS THAN 10', THE SANITARY SEWER MAIN SHALL BE UPGRADED TO AWWA C900 DR 18 PVC AND PRESSURE TESTED. 3. AT WATER MAIN/SANITARY SEWER GRAVITY MAIN CROSSINGS, PROVIDE A (MIN.) VERTICAL SEPARATION DISTANCE OF 18" BETWEEN THE BOTTOM OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE. IF THE VERTICAL SEPARATION IS LESS THAN 18", THE SANITARY SEWER MAIN SHALL BE 20 LF, CENTERED ON THE POINT OF CROSSING, OF AWWA C900 DR 18 PVC AND PRESSURE TESTED. MECHANICAL JOINTS ARE REQUIRED FOR THE SEWER PIPE IF THE SEPARATION IS LESS THAN 18". 4. ALL POTABLE WATER AND SEWER LINES TO MEET CITY OF OCOEE SPECIFICATIONS. 5. MINIMUM SLOPE ON ALL SANITARY SEWER GRAVITY MAINS TO BE 0.407o. 6. RESTORE ALL DISTURBED RIGHT-OF-WAY AREAS TO PREVIOUS CONDITION. 7. UTILITIES: ELECTRIC: PROGRESS ENERGY 407 646-8501 POTABLE WATER: CITY OF OCOEE 407 905-3100 TELEPHONE: SPRINT 407 814-5334 SEWER: CITY OF OCOEE 407 905-3100 CABLE TV: TIME -WARNER COMMUNICATIONS, INC. 407 532-8511 RECLAIMED WATER: CITY OF OCOEE 407) 905-3100 8. FOR THE CITY OF OCOEE WATER AND SANITARY SEWER DETAILS, SEE SHEET 8.. 9. ALL WORK ON UTILITIES SHALL BE OPEN TO AND SUBJECT TO INSPECTION BY AUTHORIZED PERSONNEL OF THE UTILITY COMPANIES, OWNER, AND PROJECT ENGINEER. 10. SANITARY SEWER LATERALS MUST BE AT A DEPTH OF 3 FEET (MINIMUM) NOT EXCEED 6 FEET AT THE CURB FOR ALL LOTS. 11. HYDROSTATIC TESTING SHALL BE PERFORMED IN ACCORDANCE WITH AWWA C600 OR M23 AS APPLICABLE. 12. DISINFECTION OF THE WATER DISTRIBUTION SYSTEM SHALL BE PERFORMED IN ACCORDANCE WITH AWWA C651. 13. AT WATER MAIN/STORM SEWER CROSSINGS, PROVIDE A (MIN.) VERTICAL SEPARATION DISTANCE OF 18" BETWEEN BOTTOM OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE. IF SEPARATION IS LESS THAN 18", THE WATER MAIN SHALL BE 20 LF OF DUCTILE IRON PIPE CENTERED ON THE POINT OF CROSSING. 14, WATER MAINS AND STORM SEWER MAINS ARE TO HAVE A 10' (MIN.) HORIZONTAL SEPARATION DISTANCE. IF THE HORIZONTAL SEPARATION IS LESS THAN 10', THE WATER MAIN SHALL BE AWWA C150/C151 DUCTILE IRON IN THOSE LOCATIONS. THE CONTRACTOR IS TO DEFLECT WATER MAINS AROUND DRAINAGE STRUCTURES TO AVOID CONFLICTS. 15. P.V.C. WATER MAINS SHALL BE C-900, DR 18 AS SPECIFIED IN THE ORANGE COUNTY STANDARDS FOR WATER MAIN CONSTRUCTION. 16. CONTRACTOR SHALL MAINTAIN MINIMUM 3' COVER OVER WATER MAINS, SANITARY SEWER GRAVITY MAINS, FORCE MAIN AND RECLAIMED WATER MAINS. 17. SANITARY SEWER GRAVITY MAINS SHALL BE SDR 35 PVC. 18. P.V.C. WATER PIPES MUST BEAR THE NSF LOGO FOR POTABLE WATER USE. 19. ALL DUCTILE IRON PIPES MUST BE IN ACCORDANCE WITH AWWA C160/C151. 20. AT SANITARY/STORM SEWER CROSSINGS, PROVIDE A (MIN.) VERTICAL SEPARATION DISTANCE OF 18" BETWEEN BOTTOM OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE. IF SEPARATION IS LESS THAN 18", UPGRADE THE SANITARY GRAVITY PIPE TO SDR 26 PVC. FOR FORCE MAINS, UPGRADE THE FORCE MAIN TO C900 DR -18 PVC. A MINIMUM OF 12" CLEARANCE IS REQUIRED AT THE CROSSINGS. 21. ALL UTILITIES CONSTRUCTION CONNECTING TO THE OCPU SYSTEM SHALL CONFORM TO ORANGE COUNTY MANUAL OF STANDARDS AND SPECIFICATIONS FOR WASTEWATER AND WATER MAIN CONSTRUCTION. 22. THE CONTRACTOR SHALL NOTIFY THE CITY OF OCOEE UTILITIES CONSTRUCTION DEPARTMENT 48 HOURS PRIOR TO ANY UTILITIES CONSTRUCTION. 23. AT WATER MAIN/RECLAIMED WATER MAIN CROSSINGS, PROVIDE A (MIN.) VERTICAL SEPARATION DISTANCE OF 18" BETWEEN THE BOTTOM OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE. IF THE VERTICAL SEPARATION IS LESS THAN 18", THE RECLAIMED WATER MAIN SHALL BE 20 LF, CENTERED ON THE POINT OF CROSSING, OF AWWA C900 DR 18 PVC AND PRESSURE TESTED. 24. WATER AND RECLAIMED WATER MAINS ARE TO HAVE A 5' (MIN.) HORIZONTAL SEPARATION DISTANCE MEASURED FROM CENTER TO CENTER (OR 3' INSIDE EDGE OF PIPE TO INSIDE EDGE OF PIPE). IF THE MINIMUM HORIZONTAL SEPARATION DISTANCE CANNOT BE MAINTAINED, THE RECLAIMED WATER MAIN SHALL BE UPGRADED TO AWWA C900 DR 18 PVC AND PRESSURE TESTED. 25. AT SANITARY SEWER GRAVITY MAIN/RECLAIMED WATER MAIN CROSSINGS, PROVIDE A (MIN.) VERTICAL SEPARATION DISTANCE OF 18" BETWEEN THE BOTTOM OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE. IF SEPARATION IS LESS THAN 18", THE RECLAIMED WATER MAIN SHALL BE 20 LF, CENTERED ON THE POINT OF CROSSING, OF AWWA C900 DR 18 PVC AND PRESSURE TESTED. 26. SANITARY SEWER GRAVITY MAINS AND RECLAIMED WATER MAINS ARE TO HAVE A 5' (MIN.) HORIZONTAL SEPARATION DISTANCE MEASURED FROM CENTER TO CENTER (OR 3' INSIDE EDGE OF PIPE TO INSIDE EDGE OF PIPE). IF THE MINIMUM HORIZONTAL SEPARATION DISTANCE CANNOT BE MAINTAINED, THE RECLAIMED WATER MAIN SHALL UPGRADED TO AWWA C900 DR 18 PVC AND PRESSURE TESTED. 27. THE CONTRACTOR SHALL MAINTAIN A 3' MINIMUM DISTANCE FROM THE RIGHT-OF-WAY LINE TO THE WATER MAIN / RECLAIMED WATER. AT STORM STRUCTURES, THE CONTRACTOR SHALL DEFLECT THE WATER MAIN / RECLAIMED WATER AROUND THE STORM STRUCTURES TO MAINTAIN A 1' MINIMUM CLEARANCE WITH THE STORM STRUCTURES. Q28. ALL ON-SITE UTILITIES INCLUDING ELECTRICAL, CABLE TV, AND TELEPHONE A SHALL BE PLACED BELOW GROUND. 29. EACH FIRE HYDRANT SHALL BE OSHA YELLOW IN COLOR AND A BLUE REFLECTIVE MARKER SHALL BE AFFIXED TO THE STREET IN THE CENTER OF THE LANE CLOSEST EACH HYDRANT. 30. THE CONTRACTOR SHALL REFER TO SHEET #6 FOR FDEP WATER AND SANITARY SEWER NOTES. � m w 00 I Z -1 O-_--- II ---______. O ®cc OC w anO ? i r� N -- -O N I O) I i_.. _ __ �._ +06 00 + { �° 4 I } of W O } ( i o: I C!7 C9 III ►s' to j Lt' I ?TING GROUND ' WI m�ff ® LJJ No w a W IL w (n } w rl ONE W Ick aF ~ I } I 5�� - - I -' EXISTING 1 GROUND } I 2� �- - -- I- - -- .35% ' ---- - -'-2 O% '24"I DED 8" WM TO (} } I RCP i WITH A TAPPING } } I ! E. 1 (ISTING 10" WM } EXISTING SANITARY MA Ni RIM EL 168.95 OLE } } INV EL 157.03 (N- &S! ' } ! I I r_____..._-__.___. - f i r } 324 LF -8"P 0.45% 4 � I I N N # CONNECT TO EXISTIN SANITARY U-iJ I I Z o _ W I N W� s r C:) ) N i ¢ "' m 6'• � 1 I 1 ` 06 _: _: I Cq `v} } } ! }! } } MANHOLE ® EL 159.7 (DROP CONNECTION) ? } I r •- ; W W W ``, ``, } ' � cn v- I I ILO f I --------- j !} m 00 pp C147 co co ?rn1.1(7)i rn � M } laa a; .0 � 0cp �ao }oo aNi001 E0o �coco co, co Ico� ? 9+00 9+50 NOTE: SEE SHEET #4 FOR STORM SEWER INFORMATION. 10+00 10+50 11+00 11+50 12+00 • • 12+50 13+00 13+50 171 168 165 162 159 `tfl rn 10 14+00 14+29.22 UTILITY LEGEND ® SANITARY FLOW DIRECTION ® MANHOLE U SANITARY SERVICE (DOUBLE) T SANITARY SERVICE (SINGLE) _I 90° BEND DA AIR RELEASE VALVE RECLAIMED WATER SERVICE FIRE HYDRANT GATE VALVE I I TEE 0 BLOW -OFF D REDUCER tj WATER SERVICE (DOUBLE) 1 WATER SERVICE (SINGLE) GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. UTILITY NOTES. 1. CONTRACTOR IS TO VERIFY THE LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION IN THEIR VICINITY. 2. WATER MAINS AND SANITARY SEWER GRAVITY MAINS ARE TO HAVE A 10' (MIN.) HORIZONTAL SEPARATION DISTANCE MEASURED FROM EDGE TO EDGE. IF THE HORIZONTAL SEPARATION DISTANCE IS LESS THAN 10', THE SANITARY SEWER MAIN SHALL BE UPGRADED TO AWWA C900 DR 18 PVC AND PRESSURE TESTED. 3. AT WATER MAIN/SANITARY SEWER GRAVITY MAIN CROSSINGS, PROVIDE A (MIN.) VERTICAL SEPARATION DISTANCE OF 18" BETWEEN THE BOTTOM OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE. IF THE VERTICAL SEPARATION IS LESS THAN 18", THE SANITARY SEWER MAIN SHALL BE 20 LF, CENTERED ON THE POINT OF CROSSING, OF AWWA C900 DR 18 PVC AND PRESSURE TESTED. MECHANICAL JOINTS ARE REQUIRED FOR THE SEWER PIPE IF THE SEPARATION IS LESS THAN 18". 4. ALL POTABLE WATER AND SEWER LINES TO MEET CITY OF OCOEE SPECIFICATIONS. 5. MINIMUM SLOPE ON ALL SANITARY SEWER GRAVITY MAINS TO BE 0.407o. 6. RESTORE ALL DISTURBED RIGHT-OF-WAY AREAS TO PREVIOUS CONDITION. 7. UTILITIES: ELECTRIC: PROGRESS ENERGY 407 646-8501 POTABLE WATER: CITY OF OCOEE 407 905-3100 TELEPHONE: SPRINT 407 814-5334 SEWER: CITY OF OCOEE 407 905-3100 CABLE TV: TIME -WARNER COMMUNICATIONS, INC. 407 532-8511 RECLAIMED WATER: CITY OF OCOEE 407) 905-3100 8. FOR THE CITY OF OCOEE WATER AND SANITARY SEWER DETAILS, SEE SHEET 8.. 9. ALL WORK ON UTILITIES SHALL BE OPEN TO AND SUBJECT TO INSPECTION BY AUTHORIZED PERSONNEL OF THE UTILITY COMPANIES, OWNER, AND PROJECT ENGINEER. 10. SANITARY SEWER LATERALS MUST BE AT A DEPTH OF 3 FEET (MINIMUM) NOT EXCEED 6 FEET AT THE CURB FOR ALL LOTS. 11. HYDROSTATIC TESTING SHALL BE PERFORMED IN ACCORDANCE WITH AWWA C600 OR M23 AS APPLICABLE. 12. DISINFECTION OF THE WATER DISTRIBUTION SYSTEM SHALL BE PERFORMED IN ACCORDANCE WITH AWWA C651. 13. AT WATER MAIN/STORM SEWER CROSSINGS, PROVIDE A (MIN.) VERTICAL SEPARATION DISTANCE OF 18" BETWEEN BOTTOM OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE. IF SEPARATION IS LESS THAN 18", THE WATER MAIN SHALL BE 20 LF OF DUCTILE IRON PIPE CENTERED ON THE POINT OF CROSSING. 14, WATER MAINS AND STORM SEWER MAINS ARE TO HAVE A 10' (MIN.) HORIZONTAL SEPARATION DISTANCE. IF THE HORIZONTAL SEPARATION IS LESS THAN 10', THE WATER MAIN SHALL BE AWWA C150/C151 DUCTILE IRON IN THOSE LOCATIONS. THE CONTRACTOR IS TO DEFLECT WATER MAINS AROUND DRAINAGE STRUCTURES TO AVOID CONFLICTS. 15. P.V.C. WATER MAINS SHALL BE C-900, DR 18 AS SPECIFIED IN THE ORANGE COUNTY STANDARDS FOR WATER MAIN CONSTRUCTION. 16. CONTRACTOR SHALL MAINTAIN MINIMUM 3' COVER OVER WATER MAINS, SANITARY SEWER GRAVITY MAINS, FORCE MAIN AND RECLAIMED WATER MAINS. 17. SANITARY SEWER GRAVITY MAINS SHALL BE SDR 35 PVC. 18. P.V.C. WATER PIPES MUST BEAR THE NSF LOGO FOR POTABLE WATER USE. 19. ALL DUCTILE IRON PIPES MUST BE IN ACCORDANCE WITH AWWA C160/C151. 20. AT SANITARY/STORM SEWER CROSSINGS, PROVIDE A (MIN.) VERTICAL SEPARATION DISTANCE OF 18" BETWEEN BOTTOM OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE. IF SEPARATION IS LESS THAN 18", UPGRADE THE SANITARY GRAVITY PIPE TO SDR 26 PVC. FOR FORCE MAINS, UPGRADE THE FORCE MAIN TO C900 DR -18 PVC. A MINIMUM OF 12" CLEARANCE IS REQUIRED AT THE CROSSINGS. 21. ALL UTILITIES CONSTRUCTION CONNECTING TO THE OCPU SYSTEM SHALL CONFORM TO ORANGE COUNTY MANUAL OF STANDARDS AND SPECIFICATIONS FOR WASTEWATER AND WATER MAIN CONSTRUCTION. 22. THE CONTRACTOR SHALL NOTIFY THE CITY OF OCOEE UTILITIES CONSTRUCTION DEPARTMENT 48 HOURS PRIOR TO ANY UTILITIES CONSTRUCTION. 23. AT WATER MAIN/RECLAIMED WATER MAIN CROSSINGS, PROVIDE A (MIN.) VERTICAL SEPARATION DISTANCE OF 18" BETWEEN THE BOTTOM OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE. IF THE VERTICAL SEPARATION IS LESS THAN 18", THE RECLAIMED WATER MAIN SHALL BE 20 LF, CENTERED ON THE POINT OF CROSSING, OF AWWA C900 DR 18 PVC AND PRESSURE TESTED. 24. WATER AND RECLAIMED WATER MAINS ARE TO HAVE A 5' (MIN.) HORIZONTAL SEPARATION DISTANCE MEASURED FROM CENTER TO CENTER (OR 3' INSIDE EDGE OF PIPE TO INSIDE EDGE OF PIPE). IF THE MINIMUM HORIZONTAL SEPARATION DISTANCE CANNOT BE MAINTAINED, THE RECLAIMED WATER MAIN SHALL BE UPGRADED TO AWWA C900 DR 18 PVC AND PRESSURE TESTED. 25. AT SANITARY SEWER GRAVITY MAIN/RECLAIMED WATER MAIN CROSSINGS, PROVIDE A (MIN.) VERTICAL SEPARATION DISTANCE OF 18" BETWEEN THE BOTTOM OF THE UPPER PIPE AND THE CROWN OF THE LOWER PIPE. IF SEPARATION IS LESS THAN 18", THE RECLAIMED WATER MAIN SHALL BE 20 LF, CENTERED ON THE POINT OF CROSSING, OF AWWA C900 DR 18 PVC AND PRESSURE TESTED. 26. SANITARY SEWER GRAVITY MAINS AND RECLAIMED WATER MAINS ARE TO HAVE A 5' (MIN.) HORIZONTAL SEPARATION DISTANCE MEASURED FROM CENTER TO CENTER (OR 3' INSIDE EDGE OF PIPE TO INSIDE EDGE OF PIPE). IF THE MINIMUM HORIZONTAL SEPARATION DISTANCE CANNOT BE MAINTAINED, THE RECLAIMED WATER MAIN SHALL UPGRADED TO AWWA C900 DR 18 PVC AND PRESSURE TESTED. 27. THE CONTRACTOR SHALL MAINTAIN A 3' MINIMUM DISTANCE FROM THE RIGHT-OF-WAY LINE TO THE WATER MAIN / RECLAIMED WATER. AT STORM STRUCTURES, THE CONTRACTOR SHALL DEFLECT THE WATER MAIN / RECLAIMED WATER AROUND THE STORM STRUCTURES TO MAINTAIN A 1' MINIMUM CLEARANCE WITH THE STORM STRUCTURES. Q28. ALL ON-SITE UTILITIES INCLUDING ELECTRICAL, CABLE TV, AND TELEPHONE A SHALL BE PLACED BELOW GROUND. 29. EACH FIRE HYDRANT SHALL BE OSHA YELLOW IN COLOR AND A BLUE REFLECTIVE MARKER SHALL BE AFFIXED TO THE STREET IN THE CENTER OF THE LANE CLOSEST EACH HYDRANT. 30. THE CONTRACTOR SHALL REFER TO SHEET #6 FOR FDEP WATER AND SANITARY SEWER NOTES. � m w 00 O Z 0 00 0 O ®cc OC w anO Cb ZW O 4 n = O W O C L,.; z o: to C!7 C9 w 0 U O O ►s' to Z Lt' U W t= - !. cd ® LJJ No w a W IL � rl ONE W Ick aF ~ U N 00 O Z o00 O ®cc OC w anO Cb 7 � n = O W O N W L,.; z o: to C!7 C9 ui ►s' to Z Lt' X11 !. cd ® LJJ No WE IL � rl ONE � 5 ~ F Z U N Z O Z o00 O ®cc OC w anO NO 7 • = O W O N W qz z Ic cc to C!7 C9 O ® to L -I --I X11 _> L.✓GJ ® ® LJJ No WE IL � rl ONE F Z .. LL1 j cc V. • A tic ..i IL Z N O ®cc OC w anO A. ;a cr. m IL w111C bd W Ic cc V O v° O V • • ' DRAWN: ET CHECKED: TT DATE: OCTOBER 2003 SCALE: 1"-S0' CAD NAME: PLAN & PROFILE JOB #: 11004 SHEET #: OF 9 SHEETS Ci. 0 I -d- 0 N 0 O e n i s^ c t� d- 0 �.t U s 0 CONDITIONS OF APPROVAL 1. THE CITY OF OCOEE IS SUBJECT TO THE TERMS, PROVISIONS AND RESTRICTIONS OF FLORIDA STATUES CHAPTER 163 CONCERNING MORATORIA ON THE ISSUANCE OF BUILDING PERMITS UNDER CERTAIN CIRCUMSTANCES. THE CITY HAS NO LAWFUL AUTHORITY TO EXEMPT ANY PRIVATE ENTITY, OR ITSELF, FROM THE APPLICATION OF SUCH STATE LEGISLATION AND NOTHING HEREIN SHOULD BE CONSIDERED AS SUCH AN EXEMPTION. 2. STORMWATER MANAGEMENT SHALL BE PROVIDED CONSISTENT WITH THE REQUIREMENTS OF THE OCOEE LAND DEVELOPMENT CODE AND THE ST. JOHNS RIVER WATER MANAGEMENT DISTRICT. 3. ALL FINISHED FLOOR ELEVATIONS SHALL EXCEED THE 100 YEAR FLOOD ELEVATION BY A MINIMUM OF ONE FOOT. 4. ALL ONSITE UTILITIES INCLUDING ELECTRICAL, CABLE TV AND TELEPHONE SHALL BE PLACED BELOW GROUND. 5. UNLESS OTHERWISE NOTED, A 5' UTILITY AND DRAINAGE EASEMENT WILL BE PLATTED ALONG ALL SIDE LOT LINES, AND A 10' UTILITY, DRAINAGE AND SIDEWALK EASEMENT ADJACENT TO THE STREET RIGHT-OF-WAY. SIDEWALKS WILL ONLY BE PLACED IN THIS EASEMENT IF NECESSARY TO RUN THEM AROUND EXISTING PROTECTED TREES TO BE PRESERVED. 6. ALL UTILITY AND DRAINAGE EASEMENTS UPON INDIVIDUAL LOTS SHALL BE MAINTAINED BY THE LOT OWNER.THE LAND BURDENED BY SUCH EASEMENTS SHALL Q BE OWNED BY THE INDIVIDUAL LOT OWNERS. SUCH : EASEMENTS SHALL BE DEDICATED TO THE CITY AT THE TIME OF PLATTING FOR PERPETUAL USE OF THE PUBLIC. 7. THE 10' WALL, LANDSCAPE. AND SIGNAGE EASEMENT SHALL BE FOR THE BENEFIT OF, AND SHALL BE MAINTAINED BY THE HOMEOWNERS ASSOCIATION, EXCEPT THAT ALL GRASS AND LANDSCAPING ON THE 0 HOUSE SIDE OF THE WALL WITHIN LOT 1 SHALL BE MAINTAINED BY THE OWNER OF LOT 1. THE LAND BURDENED BY THE EASEMENTS OVER LOT 1 SHALL BE PART OF AND OWNED BY THE OWNER OF LOT 1 AND THE LAND BURDENED BY THE EASEMENT OVER RETENTION POND TRACT "A" SHALL BE A PART OF TRACT "A" AND OWNED BY THE HOMEOWNERS ASSOCIATION. 8. ALL TRACTS WHICH ARE TO BE OWNED AND MAINTAINED BY THE HOMEOWNERS ASSOCIATION SHALL BE CONVEYED TO THE HOMEOWNERS ASSOCIATION BY WARRANTY DEED AT THE TIME OF PLATTING. 9. EACH FIRE HYDRANT SHALL BE OSHA YELLOW IN COLOR AND BLUE REFLECTIVE MARKER SHALL BE AFFIXED TO THE STREET IN THE CENTER OF THE LANE CLOSEST TO EACH HYDRANT. 10. THE DEVELOPER SHALL CONSTRUCT APPROPRIATE CURB CUTS TO ENABLE CONSTRUCTION OF RAMPS AT ALL RIGHT-OF-WAY INTERSECTIONS (AND OTHER AREAS AS REASONABLY REQUIRED) IN ORDER TO ACCOMMODATE ACCESS TO SIDEWALKS AND STREETS FOR PERSONS WHO ARE IN WHEELCHAIRS AND OTHER PERSONS WHO ARE PHYSICALLY CHALLENGED. SIDEWALKS ABUTTING EACH PLATTED LOT SHALL BE CONSTRUCTED AT THE TIME A HOUSE IS CONSTRUCTED ON THE LOT. WHEN SIDEWALKS ARE CONSTRUCTED ON CORNER LOTS AT CERTAIN LOCATIONS, THE SIDEWALKS WILL BE EXTENDED TO THE CURB AND THE APPROPRIATE RAMPS WILL THEN BE CONSTRUCTED. 11. ALL UNDERGROUND UTILITIES SHALL COMPLY WITH ORDINANCE NO. 95-17, WHICH REQUIRES PEDESTAL - MOUNTED UTILITY BOXES TO BE PLACED BACK OFF THE STREET, NO MORE THAN 5 FEET FORWARD OF THE FRONT BUILDING SETBACK LINE,ON ALL RESIDENTIAL LOTS WHICH ARE LESS THAN 70 FEET IN WIDTH WHERE THE LOT ABUTS THE STREET RIGHT-OF-WAY LINE. 12. NO PERSON SHALL UNDERTAKE LAND CLEARING OR THE REMOVAL OF ANY PROTECTED TREE WITHOUT FIRST OBTAINING A PERMIT FROM THE BUILDING DEPARTMENT. THE REMOVAL OF PROTECTED TREES SHALL BE MINIMIZE TO THE MAXIMUM EXTENT POSSIBLE AND NO AUTHORIZATION SHALL BE GRANTED TO REMOVE A TREE IF THE DEVELOPER HAS FAILED TO TAKE REASONABLE MEASURES TO PRESERVE SPECIMEN AND HISTORIC TREES. 13. EXISTING TREES 8" OR LARGER (OTHER THAN CITRUS TREES OR "TRASH" TREES) LOCATED ALONG PROPOSED LOCATIONS OF BUFFER WALLS OR ROAD RIGHT-OF-WAY LINES WILL BE PRESERVES IF AT ALL POSSIBLE. THE BUFFER WALLS AND ROADS WILL BE DESIGNED AROUND THOSE TREES TO INCORPORATE THEM INTO REQUIRED LANDSCAPE BUFFERS AND AS STREET TREES. 14. THE EXISTING GRADES ON INDIVIDUAL LOTS CONTAINING PROTECTED TREES WILL BE MAINTAINED AS MUCH AS POSSIBLE TO PRESERVE EXISTING PROTECTED TREES. FOR LOTS CONTAINING PROTECTED TREES, THERE. WILL BE NO GRADING OR OTHER CONSTRUCTION ON INDIVIDUAL LOTS, EXCEPT AS SPECIFIED IN THE FINAL SUBDIVISION PLAN, UNTIL BUILDING PERMITS ARE ISSUED FOR THOSE LOTS. 15. IN ORDER TO ENSURE THAT AS MANY EXISTING TREES AS POSSIBLE WILL BE PRESERVED, ALL ROAD RIGHT-OF-WAYS AND RETENTION AREAS WILL: BE FLAGGED FOR REVIEW BY THE CITY AND THE ENGINEER PRIOR TO ANY TREE REMOVAL. NO CLEARING PERMITS WILL BE ISSUED FOR SITE WORK OR BUILDING CONSTRUCTION UNTIL ALL TREES TO BE PRESERVED HAVE BEEN CLEARLY MARKED WITH TREE PROTECTION BARRIERS. 16. REMOVAL OF EXISTING PROTECTED TREES WILL BE LIMITED TO CLEARING RIGHT-OF-WAY AND RETENTION AREAS AS DETAILED IN FINAL SUBDIVISION PLAN. ALL EXISTING PROTECTED TREES ON INDIVIDUAL LOTS WILL BE EVALUATED AT THE TIME A BUILDING PERMIT IS ISSUED FOR THAT LOT, TO DETERMINE WHETHER OR NOT EACH TREE NEEDS TO BE REMOVED. 17. RETENTION POND TRACTS "A" & "B" TO BE OWNED AND MAINTAINED BY THE HOMEOWNERS ASSOCIATION WITH AN EASEMENT DEDICATED TO THE CITY OF OCOEE. 18. THE FOUNDATION FOR EACH SINGLE-FAMILY RESIDENTIAL DWELLING UNIT TO BE CONSTRUCTED ON THE PROPERTY SHALL HAVE AN ELEVATION WHICH EXCEEDS THE APPLICABLE 100 -YEAR FLOOD ELEVATION BY A MINIMUM OF ONE (1) FOOT. 19. ALL ACCESS RIGHTS TO ADAIR STREET SHALL BE DEDICATED TO THE CITY, EXCEPT AT THE APPROVED LOCATION SHOWN ON THIS PLAN. 20. ALL EXISTING STRUCTURES (INCLUDING PAVEMENT, POWER LINES, FENCES, ETC.), AS WELL AS EXISTING UTILITY EASEMENTS, WILL BE REMOVED AND/OR TERMINATED PRIOR TO OR DURING CONSTRUCTION OF THE DEVELOPMENT REPLACING THOSE USES. 21. ALL LEGAL INSTRUMENTS, INCLUDING BUT NOT LIMITED TO THE DECLARATION OF EASEMENTS, COVENANTS AND RESTRICTIONS, ASSOCIATION DOCUMENTS, AND DEEDS CONVEYING PROPERTY TO THE HOMEOWNERS ASSOCIATION, SHALL BE APPROVED BY THE CITY PRIOR TO PLAT APPROVAL. 22. ANY DAMAGE CAUSED TO ADAIR STREET AS A RESULT OF THE CONSTRUCTION ACTIVITIES RELATED TO THE PROJECT, SHALL BE PROMPTLY REPAIRED BY THE DEVELOPER TO THE APPLICABLE GOVERNMENT STANDARDS AT THE DEVELOPER'S SOLE COST AND EXPENSE. 23. THERE SHALL BE NO ACCESS FROM THE PROPERTY TO ADAIR STREET EXCEPT AT THE APPROVED LOCATION SHOWN ON THE PLAN. 24. STREETLIGHTS WILL BE INSTALLED BY THE DEVELOPER PRIOR TO CERTIFICATE OF COMPLETION AT HIS EXPENSE, AND THE COST OF OPERATIONS WILL BE ASSUMED BY THE DEVELOPER A 0 H R ACE -N0. 9 -17 25. NOTHING HEREIN SHALL BE CONSTRUCTED TO WAIVE ANY PROVISIONS OF THE LAND DEVELOPMENT CODE EXCEPT TO THE EXTENT EXPRESSLY SET FORTH ON THE WAIVER TABLE OR EXPLICITLY 0 SET OUT ON THE FINAL SUBDIVISION PLAN. 26. ALL RETENTION PONDS WILL BE UNFENCED WITH SLOPES LEADING INTO THE POND WHICH ARE NO GREATER THAN 5 -TO -1 AND BACKSLOPES NO GREATER THAN 3 -TO -1. 27. A MINIMUM OF 20 FEET UNOBSTRUCTED CLEARANCE IS REQUIRED AT ALL ENTRANCE ROADS. 28. ASIDE FROM ROAD, RETENTION AREAS AND PARK AREAS, THE ONLY LAND USE WILL BE DETACHED SINGLE-FAMILY RESIDENTIAL. 29. PURSUANT TO ORDINANCE #2001-18, ALL SUBDIVISION SIGNAGE MUST BE CONSISTENT WITH THE LEGALLY ASSIGNED NAME OF THE SUBDIVISION. THE LEGALLY; ASSIGNED NAME OF THE SUBDIVISION IS "ADAIR POINTE." ANY SUBSEQUENT CHANGE TO THE NAME OF THE SUBDIVISION. MUST BE APPROVED BY THE CITY COMMISSION. 30. A.) NOTWITHSTANDING THE CONVEYANCE OF THE STORMWATER RETENTION PONDS TO THE PROPERTY OWNERS ASSOCIATION ("THE ASSOCIATION") OR ANY PROVISIONS TO THE CONTRARY CONTAINED IN THESE CONDITIONS OF APPROVAL, THE DEVELOPER SHALL REMAIN RESPONSIBLE FOR THE MAINTENANCE OF THE PROJECT'S STORMWATER MANAGEMENT SYSTEM (SWMS), INCLUDING ALL STORMWATER RETENTION PONDS, UNTIL SUCH TIME AS :(I) THE ENTIRE SWMS FOR THE PROJECT IS CONSTRUCTED AND APPROPRIATE CERTIFICATES OF COMPLETION ISSUED BY BOTH THE CITY AND THE SJRWMD, (II) THE STORMWATER RETENTION PONDS INTENDED TO BE CONVEYED TO THE ASSOCIATION HAVE IN FACT BEEN CONVEYED TO THE ASSOCIATION, (III) THE ASSOCIATION IS DESIGNATED AS THE MAINTENANCE ENTITY ON THE RECORDS OF THE SJRWMD AND ALL TRANSFER RECORDS REQUIRED BY SJRWMD HAVE BEEN EXECUTED AND ACCEPTED BY SJRWMD, (IV) THE CITY HAS BEEN PROVIDED WITH A COPY OF THE DEVELOPER'S PROPOSED MAINTENANCE PLAN WITH RESPECT TO THE SWMS, AND (V) THE CITY HAS BEEN PROVIDED WITH A WRITTEN STATEMENT FROM THE ASSOCIATION ACKNOWLEDGING RECEIPT OF THE DEVELOPER'S PROPOSED MAINTENANCE PLAN WITH RESPECT TO THE SWMS AND THAT THE ASSOCIATION IS RESPONSIBLE FOR THE MAINTENANCE OF THE SWMS. B.) ALL DECLARATION OF COVENANTS AND RESTRICTIONS AFFECTING THE PROPERTY SHALL INCLUDE THE FOLLOWING PROVISIONS: I. PROVISIONS ALLOWING THE CITY TO LEVY, COLLECT, ENFORCE ASSESSMENTS FOR MAINTENANCE OF COMMON AREAS IF ASSOCIATION FAILS TO DO SO OR FAILS TO MAINTAIN ASSESSMENTS AT A LEVEL ALLOWING FOR ADEQUATE MAINTENANCE. II. PROVISIONS GRANTING THE CITY THE RIGHT, BUT NOT THE OBLIGATION, TO MAINTAIN/REPAIR THE SWMS AND OBTAIN REIMBURSEMENT FROM THE ASSOCIATION, OR FROM THE DEVELOPER IF (1) TURNOVER OF CONTROL TO THE MEMBERS HAS NOT OCCURRED, OR (II) IF THE DEVELOPER IS STILL RESPONSIBLE FOR MAINTENANCE OF THE SWMS. III. PROVISIONS PROVIDING THAT THE SWMS WILL BE TRANSFERRED TO A RESPONSIBLE OPERATION/MAINTENANCE ENTITY ACCEPTABLE TO THE CITY IN THE EVENT OF DISSOLUTION AND THAT IF DISSOLUTION OCCURS WITHOUT SUCH APPROVAL THEN THE CITY MAY CONTINUE TO LEVY AND COLLECT ASSESSMENTS AND IMPOSE LIENS WITH RESPECT THERETO NOTWITHSTANDING THE DISSOLUTION OF THE ASSOCIATION. IV. PROVISIONS THAT THE ASSOCIATION SHALL AT ALL TIMES BE IN GOOD STANDINGS WITH THE FLORIDA SECRETARY OF STATE. V. PROVISIONS THAT AT THE TIME OF TURNOVER OF CONTROL OF THE ASSOCIATION TO THE MEMBERS, THE DECLARANT SHALL (DELIVER TO THE NEW BOARD OF DIRECTORS THE MAINTENANCE PLAN FOR THE SWMS ACCOMPANIED BY THE ENGINEER'S CERTIFICATION THAT THE SWMS IS FUNCTIONING IN ACCORDANCE WITH ALL APPROVED PLANS AND PERMITS. TO THE EXTENT THAT ANY SUCH ENGINEER'S REPORT INDICATES ANY CORRECTIVE ACTION IS REQUIRED THE DECLARANT'S SHALL BE REQUIRED TO DILIGENTLY UNDERTAKE SUCH CORRECTIVE ACTION AT THE DECLARANT'S EXPENSE AND TO POST A CASH BOND WITH THE ASSOCIATION FOR THE ESTIMATED COSTS OF SUCH CORRECTIVE ACTION. VI. PROVISIONS THAT NO PROPERTY OWNED BY THE CITY OR ANY OTHER GOVERNMENTAL ENTITY SHALL BE SUBJECT TO ASSESSMENTS LEVIED BY THE ASSOCIATION. VII. PROVISIONS THAT ANY AMENDMENT TO ANY PROVISION AFFECTING THE CITY REQUIRES THE CONSENT OF THE CITY IN AN INSTRUMENT RECORDED WITH THE AMENDMENT. Vill. THE ARTICLES OF INCORPORATION AND BYLAWS OF THE ASSOCIATION SHALL BE CONSISTENT WITH THE FOREGOING PROVISIONS. 31. THE LANDSCAPE BUFFER/EASEMENT ALONG ADAIR STREET SHALL HAVE SHADE TREES PLANTED EVERY 30 FEET AND SHRUBS PLANTED ALONG AT LEAST 25 % OF THE LENGTH OF THE WALL. THE WALL SHALL BE CONSTRUCTED AT' LEAST 5 FEET BACK FROM THE ROAD RIGHT-OF-WAY LINE. 32. ALL SCREEN WALLS, LANDSCAPE BUFFERS, ENTRY AND CORNER LANDSCAPE IMPROVEMENTS, AND SIDEWALKS ALONG ADAIR STREET AND ADJACENT TO COMMON AREAS ALONG THE ENTRANCE ROAD SHALL BE COMPLETED PRIOR TO ISSUANCE OF THE CERTIFICATE OF COMPLETION FOR THE SUBDIVISION IMPROVEMENTS. 33. A STREET TREE SHALL BE PROVIDED BY THE HOME BUILDER AT THE FRONT OF EACH LOT PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR THE HOUSE CONSTRUCTED ON THAT LOT. EACH TREE SHALL BE A SHADE TREE AND SHALL BE A MINIMUM OF 2" DBH AND 10' TALL AT THE TIME OF PLANTING. 34. THE PLAN SHOWS AVAILABLE PAD SIZE FOR REFERENCE ONLY. FOR EACH INDIVIDUAL LOT, THE BUILDINGS SHALL NOT EXCEED 40% LOT COVERAGE AND THE TOTAL OF ALL IMPERVIOUS SURFACES SHALL NOT EXCEED 50 % LOT COVERAGE. 35. ALL UTILITIES TO BE PLACED WITHIN THE 10' EASEMENT ALONG THE FRONT OF EACH LOT WILL BE PLACED AROUND EXISTING PROTECTED TREES TO BE PRESERVED. Q36. AT SUCH TIME AS THE CITY OR DEVELOPER ACQUIRES FEE TITLE OR AN EASEMENT TO THE ADJACENT LAND IMMEDIATELY SOUTH OF THE 0 SUBDIVISION, THE DEVELOPER SHALL EXTEND THE 4' SIDEWALK ALONG THE EASTERN EDGE OF TRACT "B" ACROSS THE ACQUIRED PROPERTY TO CITY 3 PROPERTY TO ALLOW PEDESTRIAN ACCESS FROM THE SUBDIVISION TO THE ADJACENT CITY PARK, EAST OF THE SUBDIVISION. IN THE EVENT ACQUISITION OF THE PROPERTY OCCURS FOLLOWING TURNOVER OF CONTROL OF THE ASSOCIATION TO THE MEMBERS, THE ASSOCIATION SHALL BE RESPONSIBLE FOR EXTENDING THE SIDEWALK. THE DECLARATION OF COVENANTS, CONDITIONS AND RESTRICTIONS SHALL INCLUDE A PROVISION SETTING FORTH THIS OBLIGATION. Q37. AT THE TIME OF APPROVAL OF THIS FINAL SUBDIVISION PLAN, THE DEVELOPER SHALL CONTRIBUTE $6,000.00 TO THE CITY FOR RECREATIONAL EQUIPMENT FOR USE OFF-SITE ON CITY PROPERTY TO BE DETERMINED BY THE CITY OF OCOEE PARKS AND RECREATION DEPARTMENT. 1. ALL PIPE, PIPE FITTINGS, PIPE JOINT PACKING AND JOINTING MATERIALS, VALVES, FIRE HYDRANTS, AND METERS INSTALLED UNDER THIS PROJECT WILL CONFORM TO APPLICABLE AMERICAN WATER WORKS ASSOCIATION (AWWA) STANDARDS.- (FAC 62-555.320)(21)(8), RSWW 8.0, AND AWWA STANDARDS AS INCORPORATED INTO FAC 62-555.330; EXCEPTIONS ALLOWED UNDER FAC 62-555.320(21)(C)) 2. ALL PUBLIC WATER SYSTEM COMPONENTS, EXCLUDING FIRE HYDRANTS, THAT WILL BE INSTALLED UNDER THIS PROJECT AND THAT WILL COME INTO CONTACT WITH DRINKING WATER WILL CONFORM TO NSF INTERNATIONAL STANDARD 61 AS ADOPTED IN RULE 62-555.320.(3)(8), F.A.C., OR OTHER APPLICABLE STANDARD, REGULATIONS, OR REQUIREMENTS REFERENCED IN PARAGRAPH 62-555.320(3)(B), F.A.C., (FAC 62-555.320(3)(B); EXCEPTIONS ALLOWED UNDER FAC 62-555.320(3)(D)) 3. ALL PIPE AND PIPE FITTINGS INSTALLED UNDER THIS PROJECT WILL CONTAIN NO MORE THAN 8.0% LEAD, AND ANY SOLDER A FLUX USED IN THIS PROJECT WILL CONTAIN NO MORE THAT 2.0% LEAD. (FAC 62-555.322) 4. ALL PIPE AND PIPE FITTINGS INSTALLED UNDER THIS PROJECT WILL BE CODED OR MARKED IN ACCORDANCE WITH SUBPARAGRAPHS 62-555.320 (21)(8)3, F.A.C., USING BLUE AS A PREDOMINANT COLOR. (UNDERGROUND PLASTIC PIPE WILL BE SOLID -WALL BLUE PIPE, WILL HAVE A CO -EXTRUDED BLUE EXTERNAL SKIN, OR WILL BE WHITE OR BLACK PIPE WITH BLUE STRIPES INCORPORATED INTO, OR APPLIED TO, THE PIPE WALL; AND UNDERGROUND METAL OR CONCRETE PIPE WILL HAVE BLUE STRIPES APPLIED TO THE PIPE WALL. PIPE STRIPED DURING MANUFACTURING OF THE PIPE WILL HAVE CONTINUOUS STRIPES THAT RUN PARALLEL TO THE AXIS OF THE PIPE, THAT ARE LOCATED AT NO GREATER THAN 90 -DEGREE INTERVALS AROUND THE PIPE, AND THAT WILL REMAIN INTACT DURING AND AFTER INSTALLATION OF THE PIPE. IF TAPE OR PAINT IS USED TO STRIP PIPE DURING INSTALLATION OF THE PIPE, THE TAPE OR PAINT WILL. BE APPLIED IN A CONTINUOUS LINE THAT RUNS PARALLEL TO THE AXIS OF THE PIPE AND THAT IS LOCATED ALONG THE TOP OF THE PIPE; FOR PIPE WITH AN INTERNAL DIAMETER OF 24 INCHES OR GREATER, TAPE OR PAINT WILL BE APPLIED IN CONTINUOUS LINES ALONG EACH SIDE OF THE PIPE AS WELL AS ALONG THE TOP OF THE PIPE. ABOVEGROUNG PIPE WILL BE PAINTED BLUE OR WILL BE COLORED CODED OR MARKED LIKE UNDERGROUND PIPE.) (FAC 62-555.320 (21)(8)3) 5. NEW OR ALTERED WATER MAINS INCLUDED IN THIS PROJECT WILL BE INSTALLED IN ACCORDANCE WITH APPLICABLE AWWA STANDARDS OR IN ACCORDANCE WITH MANUFACTURES' RECOMMENDED PROCEDURES. (FAC 62-555.320(20)(B), RSWW 8.5.1, AND AWWA STANDARDS AS INCORPORATED INTO FAC 62-555.330) 6. A CONTINUOUS AND UNIFORM BEDDING WILL BE PROVIDED IN TRENCHES FOR UNDERGROUND PIPE INSTALLED UNDER THIS PROJECT; BACKFILL MATERIAL WILL BE TAMPED IN LAYERS AROUND UNDERGROUND PIPE INSTALLED UNDER THIS PROJECT AND TO A SUFFICIENT HEIGHT ABOVE THE PIPE TO ADEQUATELY SUPPORT AND PROTECT THE PIPE; AND UNSUITABLY SIZED STONES (AS DESCRIBED IN APPLICABLE AWWA STANDARDS OR MANUFACTURES' RECOMMENDED INSULATION PROCEDURES) FOUND IN TRENCHES WILL BE REMOVED FOR A DEPTH OF AT LEAST SIX INCHES BELOW THE BOTTOM OF UNDERGROUND PIPE INSTALLED UNDER THIS PROJECT. (FAC 62-555.320(21)(B), RSWW 8.5.2) 7. ALL WATER MAIN TEES, BENDS, PLUGS, AND HYDRANTS INSTALLED UNDER THIS PROJECT WILL BE PROVIDED WITH THRUST BLOCKS OR RESTRAINED JOINTS TO PREVENT MOVEMENT. (FAC 62-555.320 (21)(B) AND RSWW 8.5.4) 8. NEW OR ALTERED WATER MAINS, THAT ARE INCLUDE IN THIS PROJECT AND THAT WILL BE CONSTRUCTED OF ASBESTOS -CEMENT OR POLYVINYL CHLORIDE PIPE WILL BE PRESSURE AND LEAKAGE TESTED IN ACCORDANCE WITH AWWA STANDARDS C603 OR C605, RESPECTIVELY, AS INCORPORATED INTO RULE 62-555.330, FAC., AND ALL OTHER NEW OR ALTERED WATER MAINS INCLUDED IN THIS PROJECT WILL BE PRESSURE AND LEAKAGE TESTED IN ACCORDANCE WITH AWWA STANDARD C600 AS INCORPORATED INTO RULE 62-555.330. (FAC 62-555.320 (21)(B) 1 AND AWWA STANDARDS AS INCORPORATED INTO FAC 62-555.330) 9.. NEW OR ALTERED WATER MAINS, INCLUDING FIRE HYDRANT LEADS AND INCLUDING SERVICE LINES THAT WILL BE UNDER THE CONTROL OF A PUBLIC WATER SYSTEM AND THAT HAVE AN INSIDE DIAMETER OF THREE INCHES OR GREATER, WILL BE DISINFECTED AND BACTERIOLOGICALLY EVALUATED IN ACCORDANCE WITH RULE 62-555.340, FAC (FAC 62-555.320(21)(B) 2 AND FAC 62-555.340) 10. NEW OR RELOCATED, UNDERGROUND WATER MAINS INCLUDED IN THIS PROJECT WILL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST 3 FEET BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED VACUUM -TYPE SANITARY SEWER, STORM SEWER, STORMWATER FORCE MAIN, OR PIPELINE COVERING RECLAIMED WATER REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C.; A HORIZONTAL DISTANCE OF AT LEAST 6 FEET BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED GRAVITY -TYPE SANITARY SEWER (OR A HORIZONTAL DISTANCE OF AT LEAST 3 FEET BETWEEN THE OUTSIDE THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED GRAVITY -TYPE SANITARY SEWER IF THE BOTTOM OF THE WATER MAIN WILL BE LAID AT LEAST SIX INCHES ABOVE THE TOP OF THE SEWER); A HORIZONTAL DISTANCE OF AT LEAST SIX FEET BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED PRESSURE-TYPE SANITARY SEWER, WASTEWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER NOT REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C.; AND A HORIZONTAL DISTANCE OF AT LEAST 10 FEET BETWEEN THE OUTSIDE OF THE WATER MAIN AND ALL PARTS OF ANY EXISTING OR PROPOSED "ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEM." (FAC 62-555.314(1); EXCEPTIONS ALLOWED UNDER FAC 62-555.314(5)) 11. NEW OR RELOCATED, UNDERGROUND WATER MAINS THAT ARE INCLUDED IN THIS PROJECT AND THAT WILL CROSS ANY EXISTING OR PROPOSED GRAVITY- OR VACUUM -TYPE SANITARY SEWER WILL BE LAID SO THE OUTSIDE OF THE WATER MAIN IS AT LEAST SIX INCHES ABOVE THE OTHER PIPELINE; AND NEW OR RELOCATED, UNDERGROUND WATER MAINS THAT ARE INCLUDED IN THIS PROJECT AND THAT WILL CROSS ANY EXISTING OR PROPOSED PRESSURE-TYPE SANITARY SEWER, WASTEWATER OR STORMWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER WILL BE LAID SO THE OUTSIDE OF THE WATER MAIN IS AT LEAST 12 INCHES ABOVE OR BELOW THE OTHER PIPELINE. (FAC 62-555.314(2); EXCEPTIONS ALLOWED UNDER FAC 62-555.314(5)) 12. AT THE UTILITY CROSSING DESCRIBED IN PART II.C.W ABOVE, ONE FULL LENGTH OF WATER MAIN PIPE WILL BE CENTERED ABOVE OR BELOW THE OTHER PIPELINE SO THE WATER MAIN JOINTS WILL BE AS FAR AS POSSIBLE FROM THE OTHER PIPELINE OR THE PIPES WILL BE ARRANGES SO THAT ALL WATER MAIN JOINTS ARE AT LEAST THREE FEET FROM ALL JOINTS IN VACUUM -TYPE SANITARY SEWERS, STORMSEWERS, STORMWATER FORCE MAINS, OR PIPELINES CONVEYING RECLAIMED WATER UNDER PART III OF CHAPTER 62-610, F.A.C., AND AT LEAST SIX FEET FROM ALL JOINTS IN GRAVITY- OR PRESSURE-TYPE SANITARY SEWERS, WASTEWATER FORCE MAINS, OR PIPELINES CONVEYING RECLAIMED WATER NOT REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C. (FAC 62-555.314(2); EXCEPTIONS ALLOWED UNDER FAC 62-555.314(5)) 13. WHERE THE FDEP WATER NOTES AND UTILITY NOTES (ON SHEET#5) CONFLICT THE MOST RESTRICTIVE CRITERIA SHALL APPLY. FDEP SANITARY SEWER NOTESi 1. TESTING IS REQUIRED AFTER THE FINAL BACKFILL HAS BEEN IN PACE AT LEAST 30 DAYS TO PERMIT STABILIZATION OF THE SOIL -PIPE SYSTEM. TESTING REQUIREMENTS SPECIFY: 1) NO PIPE SHALL EXCEED A DEFLECTION OF 5%; 2) USING A RIGID BALL OR MANDREL FOR THE DEFLECTION TEST WITH A DIAMETER NO LESS THAN 95% OF THE BASE INSIDE DIAMETER OR AVERAGE INSIDE DIAMETER OF THE PIPE, DEPENDING ON WHICH IS SPECIFIED IN THE ASTM SPECIFICATIONS, INCLUDING THE APPENDIX, TO WHICH THE PIPE MANUFACTURED; AND 3) PERFORMING THE TEST WITHOUT MECHANICAL PULLING DEVICES. [RSWF 33.85] 2. LEAKAGE TESTS ARE SPECIFIED REQUIRING THAT: 1) THE LEAKAGE EXFILTRATION OR INFILTRATION DOES NOT EXCEED 200 GALLONS PER INCH OF PIPE DIAMETER PER MILE PER DAY FOR ANY SECTION OF THE SYSTEM; 2) EXFILTRATION OR INFILTRATION TESTS BE PERFORMED WITH A MINIMUM POSITIVE HEAD OF 2 FEET; AND 3) AIR TESTS, AS A MINIMUM, CONFORM TO THE TEST PROCEDURE IN ASTM C-828 FOR CLAY PIPE, ASTM C 924 FOR CONCRETE PIPE, ASTM F-1417 FOR PLASTIC PIPE, AND FOR OTHER MATERIALS APPROPRIATE TEST PROCEDURES. [RSWF 33.93, 33.94, AND 33.95] 3. A BENCH SHALL BE PROVIDED ON EACH SIDE OF ANY MANHOLE CHANNEL WHEN THE PIPE DIAMETER(S) ARE LESS THAN THE MANHOLE DIAMETER AND THAT NO LATERAL SEWER, SERVICE CONNECTION, OR DROP MAHOLE PIPE DISCHARGES ONTO THE SURFACE OF THE BENCH. 50' R/W TOOLED EDGES 1/8" RADIUS -�� 1/8" 4: d 4 d e e.• • • • G • •- o v �• e , e CONTRACTION JOINT N.T.S. ° °• 'e• tie PREMOULDED JOINT MATERIAL EXPANSION JOINT N.T.Y. 4'OR5'WIDE 4" THICK r-1 1 1-111-" CONCRETE WALK AT 3,000 P.S.I.; WOOD FLOAT FINISH, SAW CUT CONTRACTION JOINTS AT 5' O.C. MIN. EXPANSION JOINTS COMPACTED SUBGRADE AT 20' O.C. MIN. CONCRETE SIDEWALK N.T.S. 4' 7' 2' 1 24' PAVEMENT 2' 7' MIAMI CURB (TYP) 1-1/2" FDOT TYPE S-1 24" ASPH CONC (TYP) 12" 12" 12" 12" 2%, 2.08% 2.08%_� 1/2" R �I ��� \� . r�\i\\ �\\r\\.1\\� �_1\ STABILIZED • SUBGRADE: - 310 MLAMI CURB - N.T.S. 12" (TYP) CONC SIDEWALK (TYP) 12" (TYP) .13 I Z6" THICK STABILIZED SUBGRADE (TYP) 6" LIMEROCK BASE COMPACTED TO MIN. DENSITY OF 98% OF MAX. DENSITY PER AASHTO T-180 (TYP) 12" SUBBASE COMPACTED TO 95% MAX DENSITY THE TOP 6" STABILIZED TO FBV 50 (TYP) TYPICAL. RY ROADWAY SECTION N.T.S. V N to .�.-- O ro C. 0 0 NCV 0 0 0 0 T CD Z O � o W 8 o a/ Wuj cc U 0 Q 0 L a , [1�'j 00 0 U 0 � 0 v F W w_ nW. C., W a W Z 3 e =>� N 0 N W 0 ® W ®® M a Z so O V N to .�.-- O ro I N T CD Z LjNO � ru') a/ Q� !fl) L 4-J a , [1�'j �; Z Ew � � F z v e =>� 0 0 ® ®® 0 4c Z so O 0 V N oc .�.-- O Z O � N T Z LjNO � 0o a/ Q� ¢ z L 4-J U. F v N =>� 0 0 ® ®® 0 4c Z so O ® ® V v 14c Z mi 0 W CCj P go J DRAWN: ET CHECKED: TT DATE: OCTOBER 2005 SCALE: NONE CAD NAME: DETAILS & NOTES JOB #: 11004 SHEET #: 6 OF 9 SHEETS E t 0 0 R fn 2 0 z .5 0 p v 4.1 �n 0 U. esa B �r to t 0 0 O m oc MID OC IL Z M ® ® W !� E.. �o m°� cc q W ui luv U. F v DRAWN: ET CHECKED: TT DATE: OCTOBER 2005 SCALE: NONE CAD NAME: DETAILS & NOTES JOB #: 11004 SHEET #: 6 OF 9 SHEETS E t 0 0 R fn 2 0 z .5 0 p v 4.1 �n 0 U. esa B �r to t 0 0 O m IL Z 14c cc mi 0 DRAWN: ET CHECKED: TT DATE: OCTOBER 2005 SCALE: NONE CAD NAME: DETAILS & NOTES JOB #: 11004 SHEET #: 6 OF 9 SHEETS E t 0 0 R fn 2 0 z .5 0 p v 4.1 �n 0 U. esa B �r to t 0 0 O m �- Inlet Type 2 Symmetrical About € t .6 0•a�°• f-- A 2' Did. Cover See Slab Reinforcing + € Inlet Detail This Sheet. B s" B `zo 5' 0 Concrete TP I i Support Post 3'-0" L...A PLAN (INLET TYPE 2 SYMMETRICAL ABOUT 0 To Be Paid Limits Of Inlet Construction To Be Paid For As C. & G. For As C. & G. F.L. Of Gutter Ia to %T W I DIMENSIONAL SECTION INLETS TYPES I AND 2 #6 Bars Unless Inlet Type 4 Symmetrical About € �,. A 0 2' Dia. Cover See Slab Reinforcing Detall This Sheet. + s;p 6a € Inlet ` B �" B L5" 0 Concrete Z01 J Support Post 9'-0" L..A PLAN (INLET TYPE 4 SYMMETRICAL ABOUT 0 To Be Paid Limits Of Inlet Construction To Be Paid For As C. & G. For As C & G. F.L. Of Gutter to T I31-L 6'-0" 3'-O" { 3'-0' r Gutter Gutter ° Trans. Trans. SECTION BB (INLET TYPE 4 SYMMETRICAL ABOUT 0 4'- !'-6" b -T Ir7( ~� See Note :c. 5" 0 Concrete �D No. 4 Support Post 6" Concrete Or 8" Brick. DIMENSIONAL SECTION INLETS TYPES 3 AND 4 Otherwise Shown #6 Bars Unless #6 Bars o #6 Bars oOtherwise Shown 9" Ctrs.Ae 9" Ctrs. 9" 6"' 74"7�i1�3io 9" Ctrs. #6 Bars o 9" Ctrs. #6 Bars 00 #6 Bars#4 Bars 0 8" Ctrs. o B" Ctrs. #4 Bars #7 Bors l -5 {Both Ways Both Ways trs. #4 Bars o 8" Ctrs. 3'-6' Diameter _I r 4'-0" Diameter 1 REINFORCING SECTION REINFORCING SECTION 3'-6" DIA. STRUCTURE BOTTOM (SECTION AA) 4'-O" DIA. STICTURE BOTTOM (SECTION AAI TRANSVERSE SECTIONS FOR INLETS TYPES 1, 2, 3 & 4 K21 o CURB INLET TOPS TYPES 1, 2, 3 & 4 - N.T.S. rA m� #6 Bars o 9" e #6 Bars Q Back Of Curb--_ Face Of Curb Back Of . 1 pport Post INLETS TYPES I AND 3 INLETS TYPES 2 AND 4 SLAB REINFORCING GENERAL NOTES 1. The finished grade and slope of the inlet tops are to conform with the finished cross slope and grade of the proposed sidewalk and/or border. 2. When inlets are to be constructed on a curve, refer to the plans to determine the radius and, where necessary, modify the inlet details ac ordingly. Bend steel when necessary. J. All steel In inlet top shall have 14' minimum cover unless otherwise shown. Inlet tops shall be either cast -In-place or precast concrete. 4. The rear wall portion of Inlet tops Types 1, 2, 3 & 4 may be constructed with brick. Dowels to top slab required. 6. For supplemental details see Index No. 201. 5. Only round concrete support post will be acceptable. 7. These Inlets are to be used with Curb and Gutter Types E and F. Locate outside of pedestratn crosswalk where practical. 8. For sturature bottoms see Index No. 200. 9. Inlet to be paid for under the contract unit price for Inlets (Curb) (Type_), Each. 9" b"' 7r 10' #6 Top Bars P- 10j 7" J J' #6 Bottom Bars 2/g For 3'-6" Structure Bottom #7 Bottom Bars 3"3" 181'For 4'-0" Structure Bottom FF#6 Bars o 9"' Ctrs. , III I � ti i I zO I. P-6' #4 Bars o 8" Ctrs. r� DIMENSION & REINFORCING HALF SECTION TYPES A & E CURB (HALF SECTION AA) (TYPE E GUTTER SHOWN) 3'-0" I 12'MIN. EXAMPLE 70'-0" R/W '-0" 3'-0" 00 Gutter DRIVEWAY Gutter & Trans. r CI Trans. �-�- 12' MIN. -+� g' SECTION BB (INLET TYPE 2 SYMMETRICAL ABOUT 0 NO c� 4'-0" /'-6" X A B C E F G Single Pipe a Quad Pipe N � ti CONCRETE Single Double Pipe Pipe (Cu. Yds.) Triple Quad Pipe Pipe to Quad Pipe /9- SeeNote v 2.27' 5" 0 Concrete 6.36' 4.03' No. 4 1.22' Support Post I _? 9.79' 12.37' 1.19' OC4 0.76 6' Concrete Or 8" Brick. I,.jI.. 15„I 194 8 /D DIMENSIONAL SECTION INLETS TYPES I AND 2 #6 Bars Unless Inlet Type 4 Symmetrical About € �,. A 0 2' Dia. Cover See Slab Reinforcing Detall This Sheet. + s;p 6a € Inlet ` B �" B L5" 0 Concrete Z01 J Support Post 9'-0" L..A PLAN (INLET TYPE 4 SYMMETRICAL ABOUT 0 To Be Paid Limits Of Inlet Construction To Be Paid For As C. & G. For As C & G. F.L. Of Gutter to T I31-L 6'-0" 3'-O" { 3'-0' r Gutter Gutter ° Trans. Trans. SECTION BB (INLET TYPE 4 SYMMETRICAL ABOUT 0 4'- !'-6" b -T Ir7( ~� See Note :c. 5" 0 Concrete �D No. 4 Support Post 6" Concrete Or 8" Brick. DIMENSIONAL SECTION INLETS TYPES 3 AND 4 Otherwise Shown #6 Bars Unless #6 Bars o #6 Bars oOtherwise Shown 9" Ctrs.Ae 9" Ctrs. 9" 6"' 74"7�i1�3io 9" Ctrs. #6 Bars o 9" Ctrs. #6 Bars 00 #6 Bars#4 Bars 0 8" Ctrs. o B" Ctrs. #4 Bars #7 Bors l -5 {Both Ways Both Ways trs. #4 Bars o 8" Ctrs. 3'-6' Diameter _I r 4'-0" Diameter 1 REINFORCING SECTION REINFORCING SECTION 3'-6" DIA. STRUCTURE BOTTOM (SECTION AA) 4'-O" DIA. STICTURE BOTTOM (SECTION AAI TRANSVERSE SECTIONS FOR INLETS TYPES 1, 2, 3 & 4 K21 o CURB INLET TOPS TYPES 1, 2, 3 & 4 - N.T.S. rA m� #6 Bars o 9" e #6 Bars Q Back Of Curb--_ Face Of Curb Back Of . 1 pport Post INLETS TYPES I AND 3 INLETS TYPES 2 AND 4 SLAB REINFORCING GENERAL NOTES 1. The finished grade and slope of the inlet tops are to conform with the finished cross slope and grade of the proposed sidewalk and/or border. 2. When inlets are to be constructed on a curve, refer to the plans to determine the radius and, where necessary, modify the inlet details ac ordingly. Bend steel when necessary. J. All steel In inlet top shall have 14' minimum cover unless otherwise shown. Inlet tops shall be either cast -In-place or precast concrete. 4. The rear wall portion of Inlet tops Types 1, 2, 3 & 4 may be constructed with brick. Dowels to top slab required. 6. For supplemental details see Index No. 201. 5. Only round concrete support post will be acceptable. 7. These Inlets are to be used with Curb and Gutter Types E and F. Locate outside of pedestratn crosswalk where practical. 8. For sturature bottoms see Index No. 200. 9. Inlet to be paid for under the contract unit price for Inlets (Curb) (Type_), Each. 9" b"' 7r 10' #6 Top Bars P- 10j 7" J J' #6 Bottom Bars 2/g For 3'-6" Structure Bottom #7 Bottom Bars 3"3" 181'For 4'-0" Structure Bottom FF#6 Bars o 9"' Ctrs. , III I � ti i I zO I. P-6' #4 Bars o 8" Ctrs. r� DIMENSION & REINFORCING HALF SECTION TYPES A & E CURB (HALF SECTION AA) (TYPE E GUTTER SHOWN) Ta -I I 06.42' 0 6.25' Dimensions permitted to allow use of 8' stanaard pipe lengths. 010.40' O 10.10' Dimensions permitted to allow use of 72' standard pipe lengths. 0 O Concrete slab shall be deepened to form bridge across crown of pipe. See section below. Sod Beveled Or Round Comers N Cid Constriction Joints Permitted ' Grate FF1 �\ Fastener : Concrete Slab, 3' Thick, Reinforced With WWF 6x6-W1.4xW14 TOP VIEW -SINGLE PIPE n,� rzT%s o O-��i--- Gomes SAx�°ai Saddle 2' -1 i Not Less Than D No Pipe Joint Permitted Unless Approved By The Engineer E Paid For As Pipe Culvert F (Pipe To Be Included Under Unit Price For Mitered I SECTION W tu rxI )K Construction Joints Permitted Ditch Grade 3' 2' Sod I' Beveled Or Round Corners I I -T =1 I Grate 1 Joints Permitted - Fastener -LI Concrete Slab, 3' Th1ak, Reinforced With Sod WWF 6x6-W14xW14 Z�``' TOP VIEW -MULTIPLE PIPE Note: See Sheets 5 and 6 for details and general notes. *Slope: To € Pipe For Pipes /8" And Smaller 21 For Pipes 24' And Larger. 273 MITERED END SECTION ON CAST IRON GRATE NOT PERMITTED ON INLET TYPE D (-+-- VARIES 25' I 12'MIN. EXAMPLE (VARIES) R/W 25'R. .; Ilk 00 o CO CO DRIVEWAY DIMENSIONS & QUANTITiES r CI - �-�- 12' MIN. -+� g' (VARIES) MIN. vaaraaaaa�aa�a� Irrrrrrrrrr.. iaaaaaaaa.'aRa� rrrurrrrq.rr.. �.aaaaaaaaaa� NO c� Cu D X A B C E F G Single Pipe M Double Triple Pipe Pipe Quad Pipe N GRATE SIZES Standard Extra Weight Pipe Strong Pfpe CONCRETE Single Double Pipe Pipe (Cu. Yds.) Triple Quad Pipe Pipe SODDING (Sq. Y(fs.) Single Double Triple Pipe Pipe Pipe Quad Pipe /9- 2'- 2.27' 4.09 6.36' 4.03' 8' 1.22' 4.63 72/' 9.79' 12.37' 1.19' OC4 0.76 1.16 154 194 8 /D 11 !2 18' 24' 2'-10" 3'-5' 2.36' 2.53' 5.12 7./B'& 7.48' 9.71' 5.03' 7.03' o 9' R' 147' 1.73' 4.92' 5.50' T.75' 8.92' 10.58' 12.33' 73.42' 15.75' 121' 1.25' 0.85 102 1.28 158 171 215 2.I/ 2 75 9 /0 /0 12 12 13 13 /5 30" 4'-3' 2.70' 9.25' 1195' 9.03' 13' 2.00' 6.08' 10.33' 14.58' 18.83' 1.29 2 3' 123 1.98 2.74 3.50 I /2 14 15 O 36' 5'-P 2.87' 1131'0 14.18' 1103'0 /5' 2.24` 6.67' 1175' 16.83' 2J 92' 1.33 2 3' 1.40 2.38 3.33 4.24 /3 15 17 20 42' 6'- 3.05' 13.37' 16.42' 13.03' 1/' 2.45' 7.25' 13.25' 19.25' 25.25' 1.38 2 3 160 1 2.83 4.04 5.26 14 n 19 22 6'-9' 3.22' 15.43 18.65' 15.03' /9` 265' 7.83` 14.58` N. 2B.08' 142 2 3 1.81 3.26 4.70 6.14 15 18 21 24 7' -Lr r 3.39 f7.49 , r 20.88 /7.03 r 21 , 2.83 r r 8.42 16.08 r 23.75 r 3142 196 r 3w 4" 203 3.78 5.54 7.28 O 20 23 27 60" 8'-6' T 3.56' 1 19.55' 2YA 19.03' 23 TO 9.00' I7.5W 26.00' 1 34.50' 150 3' 4" 1 4.36 1 6.43 8.50 18 22 25 29 Ta -I I 06.42' 0 6.25' Dimensions permitted to allow use of 8' stanaard pipe lengths. 010.40' O 10.10' Dimensions permitted to allow use of 72' standard pipe lengths. 0 O Concrete slab shall be deepened to form bridge across crown of pipe. See section below. Sod Beveled Or Round Comers N Cid Constriction Joints Permitted ' Grate FF1 �\ Fastener : Concrete Slab, 3' Thick, Reinforced With WWF 6x6-W1.4xW14 TOP VIEW -SINGLE PIPE n,� rzT%s o O-��i--- Gomes SAx�°ai Saddle 2' -1 i Not Less Than D No Pipe Joint Permitted Unless Approved By The Engineer E Paid For As Pipe Culvert F (Pipe To Be Included Under Unit Price For Mitered I SECTION W tu rxI )K Construction Joints Permitted Ditch Grade 3' 2' Sod I' Beveled Or Round Corners I I -T =1 I Grate 1 Joints Permitted - Fastener -LI Concrete Slab, 3' Th1ak, Reinforced With Sod WWF 6x6-W14xW14 Z�``' TOP VIEW -MULTIPLE PIPE Note: See Sheets 5 and 6 for details and general notes. *Slope: To € Pipe For Pipes /8" And Smaller 21 For Pipes 24' And Larger. 273 MITERED END SECTION ON CAST IRON GRATE NOT PERMITTED ON INLET TYPE D STEEL GRATE i n 6'-0" 8" v, 8„ 3'-610 Inless Otherwise °p Unless Otherm >hown On Plans ¢ Shown On Pla NOTE: Alt. B Structure Bottom Only. See Detail No. 200 STRUCTURE BOTTOM FOR INLET TYPE D u I PLAN 5' (-+-- VARIES 25' I 12'MIN. EXAMPLE (VARIES) R/W 25'R. .; Ilk 00 o CO CO DRIVEWAY P Grote r r. r..... r... a r. r..., o r CI - �-�- 12' MIN. -+� g' (VARIES) MIN. vaaraaaaa�aa�a� Irrrrrrrrrr.. iaaaaaaaa.'aRa� rrrurrrrq.rr.. �.aaaaaaaaaa� NO c� Cu woo TYPE D 4'MIN. 4' MIN. NOTES: FLARE CURB & GUTTER Straight Bars ex PERPENDICULAR TO STREET CA CITY OF OCOEE UTILITIES DEPARTMENT OR PERPENDICULAR TO A TANGENT IF CURVILINEAR. TYPICAL LOCATIONS 2. DRIVE APPROACH AND SIDEWALK SINGLE FAMILY THROUGH DRIVE SHALL BE 6"THICK SECTION Bonds lJ'x4" OCT.,91 KOVACS I FIG 600 TYPE D APProx. Weight :,, STEEL GRATE i n 6'-0" 8" v, 8„ 3'-610 Inless Otherwise °p Unless Otherm >hown On Plans ¢ Shown On Pla NOTE: Alt. B Structure Bottom Only. See Detail No. 200 STRUCTURE BOTTOM FOR INLET TYPE D u I PLAN 5' (-+-- VARIES 25' I 12'MIN. EXAMPLE (VARIES) R/W 25'R. MAX 00 o CO CO DRIVEWAY P Grote APRON o r CI Eye Bolt �-�- 12' MIN. -+� g' (VARIES) MIN. See Index 201 NO c� #4 Bars woo (D /2' Ctrs. 4'MIN. 4' MIN. NOTES: FLARE CURB & GUTTER 1. PROPERTY LINE IS PROJECTED PERPENDICULAR TO STREET CA CITY OF OCOEE UTILITIES DEPARTMENT OR PERPENDICULAR TO A TANGENT IF CURVILINEAR. TYPICAL LOCATIONS 2. DRIVE APPROACH AND SIDEWALK SINGLE FAMILY THROUGH DRIVE SHALL BE 6"THICK SECTION DATE: DWG. FIG. OCT.,91 KOVACS I FIG 600 TYPE D Z Recommended Maxlmum Pipe Size: 3'-l" Wall -24" Pipe C/) C.5_ 4'-I' Wall -36" Pipe I v GENERAL NOTES 1. These inlets are suitable for bicycle and pedestrian areas and are to be used in ditches, medians and other areas subject to infrequent traffic loadings but are not to be placed in areas subject to any heavy wheel loads. 2. Inlets subject to minimal debris should be constructed without slots. Where debris Is a problem inlets should be constructed with slots. Slotted Inlets located within roadway clear zones and In areas accessible to pedestrians shall have traversable slots. The traversable slot modification /s not adaptable to inlet Type H. Slots may be constructed at either or both ends as shown on plans. I J. Steel grates are to be used on all inlets where bicycle traffic /s anticipated. Steel grates are to be used on al/ Inlets with traversable slots. Either cast Iron or steel grates may be used on inlets without slots where bicycle traffic is not anticipated. Either cast Iron or steel grates coy be used on all inlets with non -traversable slots. Subject to the selection described above, when Alternate G grate Is specified in the plans, either the steel grate, hot dipped galvanized after fabrication, or the cast iron grate may be used, unless the plans stipulate the particular type. 4. Recommended maximum pipe sizes shown are for concrete pipe. Pipe sizes larger than 8" those recommended must be checked for fit. 5. All exposed corners and edges of concrete are to be chamfered 10 . 6. Pavement to be used on inlets without slots and inlets with non -traversable slots only when called for In the plans: but required on all traversable slot inlets. Cost to be included in contract unit price for inlets. Quantities shown are for information only. 7. Traversable slots constructed in existing inlets shall be paid for as inlets partial, and shall Include the cost for slot openings, paving and any required replacement grates. 8. Sodding to be used on all Inlets not located in paved areas and paid for under contract unit price for Sodding SY. 9. For supplementary details see Detail No. 201. 232® E® .O®T® TYPE D INLET - N.T.S. Anchor Bales With 2 - 2' x 2' x 4' IIIIIIII Illu�l Sidewalk Stakes Per Bale. op - Ditch FE -1 Apron Ditch Curb & Gutter-//����I���III��IIIIIIIIIIUIIII�I�II�i��\­00g\ Curb & Gutter _ _ -- �(�118111�nlilill I�IIIIII�@IIIII[\ PARTIAL INLET COMPLETED INLET DITCH BOTTOM INLET PROTECTION AROUND INLETS OR SIMILAR STRUCTURES Post lOptionsr 2"x4" Or I Optional Post Position Principle Post Position 2]' Min. Dia. Wood• Steel _ (Canted 20° Toward Flow) 1.33 Lbs/Ft. Min.)6' Max. Filter Fabric (In 8 Conformance With C Sec. 985 FDOT Spec.) o � Filter Fabric o •c �llt Flow 16 ELEVATION SECTION Note: Silt Fence to be paid for under the contract unit price for Staked Silt Fence (LF). TYPE .Iii SILT FENCE v Type III" Silt Fence Protection Around Ditch Bottom Inlets. Do not deploy in a manner that silt fences will act as a dam across permanent flowing watercourses. Silt fences are to be used at upland locations and turbidity barriers used at permanent bodies of water. SILT FENCE APPLICATIONS Slit Flow Note: Spacing for Type .III Fence to be in accordance with Chart Z Sheet l of 3 and ditch installations at drainage structures Sheet 2 of J. Type .III Silt Fence BALED HAY OR STRAW BARRIERS AND SILT FENCES .T.S. PROPERTY LINE - (-+-- VARIES 25' I 12'MIN. EXAMPLE (VARIES) R/W 25'R. MAX 00 o CO CO DRIVEWAY APRON H n CURB & GUTTER �-�- 12' MIN. -+� g' (VARIES) MIN. VARIES NO 90? Z woo 4'MIN. 4' MIN. NOTES: FLARE CURB & GUTTER 1. PROPERTY LINE IS PROJECTED PERPENDICULAR TO STREET CA CITY OF OCOEE UTILITIES DEPARTMENT OR PERPENDICULAR TO A TANGENT IF CURVILINEAR. TYPICAL LOCATIONS 2. DRIVE APPROACH AND SIDEWALK SINGLE FAMILY THROUGH DRIVE SHALL BE 6"THICK WITH 6"x 6"x 10 WIRE MESH RESIDENTIAL DRIVES DATE: DWG. FIG. OCT.,91 KOVACS I FIG 600 STREET CURB & GUTTER -� NOTES: (D- CONCRETE TO BE 2500 PSI 0-- APPROACH & SIDEWALK IN DRIVE TO BE 6" THICK W/ WIRE MESH OR FIBER MESH. 3- 1 x 4 USED AT EXPANSION JOINTS TO BE PRESSURE TREATED. 4- ALL WOOD STAKES USED IN FORM WORK TO HAVE 2" OR MORE MORE OF CONCRETE COVER. (!j)- SIDEWALK TO BE JOINTED AT INCREMENTS TO EQUAL SIDEWALK WIDTH. NOT REQUIRED IN DRIVE. C-3 cm Z O 00 o CO CO � H n a T NO Z woo M 40 a Q Z K cf W � Z � C/) C.5_ N I v 90 1" rz-- C-3 cm Z O o CO CO � H n a T NO Z woo 40 Qui Q Z Z � C/) C.5_ N ® 90 1" _>L4J OC4 LL J 0- L4J � a 40 J 4C W I 0� Z 40 4-1 ® e� m W r' wIL Q INC 4C Z c IL0 U -r-a 000 e) 0 C) DRAWN: ET CHECKED: TT DATE: OCTOBER 2005 SCALE: NONE CAD NAME: DRAINAGE DETAILS JOB #: 11004 SHEET #: OF 9 SHEETS M 7) 24" x 24" x 6" TROWEL -FINISHED CORPORATION CURB STOP CORPORATION U -BRANCH THICK CONC. PAD CONCRETE BENCHING STOP (1" MIN.) (SEE NOTE 3) STOP (1" MIN.) FITTING RAISED 1-1/2" LETTERS RAISED 1-1/2" LETTERS TYP. EACH VALVE BOX. (1 x /4" SET TOP OF VALVE BOX FLUSH WITH TOP OF COVER CONCRETE BASE SEE MANHOLE MARK WITH ( x 3/4' FLUSH WITH TOP OF COVER 3" DIA. BRONZE DISC WOOD PAINTED ANCHORED IN CONC. PAD #4 BARS ALL so o CONNECTION BLUE & WITH CURB STOP TO FINISHED GRADE STAMP AS R Q D AAROUND 3 DIA. BRONZE A ;v LOT NUMBERS 2 EA. (SEE NOTE 1) DISC ANCHORED IN z z 6" REINFORCED CONCRETE CONC. PAD STAMP COLLAR IN UNPAVED AREA SIZE OF VALVE AS REQ D. FINISHED GRADE �\ OF 0 OF TYPE OF VALVELj •d SERVICE �' ®' •• ,•" � � a a �// �/�� '�:: . •'e� � �// � �, F WATER ' •. : •, � ?i- /,\�\r�///� � /% /�/\/, //�\�\ L-zD !' •'//.���%�/�: SANITARY SANITARY DIRECTION & NO. f, i �~'' N POLYETHYLENE POLYETHYLENE \//,\ /.\� OF TURNS TO 4' '' • _ MANHOLE FRAME &COVER ADJUSTABLE CAST IRON OPEN WATER (SEE STANDARD DETAIL) TUBING (1" MIN.) TUBING (1" MIN.) VALVE BOX •� SEE NOTE 1 • : ' { , SET COVERS FLUSH IN FRAMES BEDDED IN MORTAR SINGLE METER BOX DOUBLE METER BOX • � . ' • - - - • - '� - • ' � � PAVED AREAS & AT VALVE BOX f �, ELEVATOONS SHOWN IN AND WATER METER AND WATER METER BOX SHALL REST ON FCORVD 10RIDP AND COVER • e• ., . +.''. ,,, �= �'' UNPAVED AREAS. 2 - NON PENETRATING (TYP.) • •• - - ��/ i 2 COURSES OF BRICK MIN. (BY CITY) (BY CITY) BEDDING ROCK NOT 2 - NON PENETRATING 4 COURSES MAX.) SINGLE SERVICE DOUBLE SERVICE M.J. PLUG VALVE ON VALVE OR PIPE PICK HOLES :• : i•` »' • ..• PICK HOLES 2500 P.S.I. 1'-6" MIN. w CONCRETE MIN. 1 ANCHORS- 3-0 MAX. 5" 2'-0" ¢ WASTEWATER AND SHALL BE > INSIDE WALL OUTSIDE WALL CORPORATION STOP FORCE MAIN CENTERED ON PLAN PRE -PRIMED ° OPERATING NUT PLAN EPDXY COAL TAR COATINGS cn o JOINT SURFACES & FITTING UNIMPROVED CONDITION PER SPECIFICATIONS 4'-0" 5" MIN. ¢ (NORMALLY OPEN) °.°° PRE -PRIMED PRE -MOLDED ° • o `° • o opo ^o•o.o•° PLASTIC JOINT o•o°o•o°O• JOINT SURFACES SEALER WITH AWWA TYPE �o ° • o • o TOP FLUSH WITH PROTECTIVE ° o • o • o GD WRAPPER CC THREADS o ° • ° • °'° • ° o W (WRAPPER TO TO METER BOX I°"°o.°°o•°° °° MACHINED FINISHED GRADE BENCHING PER SPECIFICATIONS "1„ D x BEREMOVED) ,., o•° o,°°°•°°o,°°°.° °.° 23-3/4' MACHINED a ~ASSEMBLY ,°°„° °°°.° °° °° °° ° „° MATING MATING 9" ASPHALT SURFACE 6 > ° ° REINFORCEMENT AND JOINT---,,souE¢E-our SADDLE '�e"o'oo"o "ooO�0000 o"'o�00000,o'o.o'oe°' SURFACES DETAIL TO BE DESIGNED BY N. COMPLETED POLYETHYLENE ° °°o.°°o.o o. SURFACES 7 JOINT WITH - i•e°o°o o.o°o•o°o •o o•o°a.o o-o'o.o'o.o° IN, souE¢E-our - 45 DEG TUBING �BY THE LJ722-�1/4- BASE 1 4"THE ENGINEER AND j $ M o.°o•o °•o °•° ooAPPROVED „ 9" � 3QCITY � 'i� 6" BEDDING ROCK ° /9�9 BEDDING ROCK 2" MIN. WATER MAIN CAST -IN-PLACE PRECAST MONOLITHIC CONCRETE BASE BASE 2-7/8" 4-3 4" MIN. 4" x 4" x 18" LONG NOTES: VALVE BOX (MIN.) PRECAST POST 1. ALL FITTINGS SHALL BE BRASS WITH COMPRESSION/PACK JOINT AND COVER WITH 3 DIAMETER . TYPE CONNECTIONS. ELEVATION ELEVATION BRONZE DISC SET IN (TYP.) GROUT AS SHOWN 1. M� HOLE SHOWN IS FOR SEWER SIZE 8" THRU 24', SEE SECTION 20.4.3 OF THE 2. NO SERVICE LINE SHALL TERMINATE UNDER A DRIVEWAY. NOTES: IMPROVED CONDTITION ABOVE. MANUAL FOR MANHOLE DIAMETER FOR SEWERS LARGER THAN 24". 3. EACH SERVICE SHALL TERMINATE AT A CURB STOP(S) WHICH 1. PVC EXTENSIONS SHALL NOT BE USED ON VALVE BOX INSTALLATION. 2. DROP CONNECTIONS ARE REQUIRED WHENEVER INVERT OF INFLUENT SEWER IS SHALL BE EXPOSED APPROXIMATELY 3' ABOVE FINAL GRADE AND THE ACTUATING NUT FOR DEEPER VALVES SHALL BE EXTENDED TO NOTES: 24" OR MORE ABOVE THE INVERT OF THE MANHOLE. SEE MANHOLE TIED TO A 2" x 4" x 4" STAKE WITH (ITHE TOP PAINTED BLUE AND COME UP TO 4 FOOT DEPTH BELOW FINISHED GRADE. 1. BRONZE IDENTIFICATION DISC SHALL BE REQUIRED FOR ALL VALVES 16" AND CONNECTION DETAILS. MARKED WITH THE NUMBER OF THE LOTS TO BE SERVED. LARGER, OR AS REQUIRED BY THE CITY FOR CRITICAL OFFSITE VALVES. 3. APPROVED CONCENTRIC CONE DESIGN MAY BE USED AS AN ALTERNATIVE. LOT(S) 2. VALVE COLLAR DIMENSIONS MAY BE REDUCED TO 18" x 18" x 6" WHEN CITY OF OCOEE UlIU71ES DEPARTMENT CITY OF OCOEE UMUMES DEPARTMENT CITY OF OCOEE UTIUMES DEPARTMENT CITY OF OCOEE UTILITIES DEPARTMENT CITY OF OCOEE U1IU7IES DEPARTMENT CITY OF OCOEE U1IUTIES DEPARTMENT THE BRONZE IDENTIFICATION DISC IS NOT REQUIRED. PRECAST CONCRETE MANHOLE WATER SERVICE CONNECTION DETAILS OPTIONAL MANHOLE OPTIONAL MANHOLE VALVE COLLAR DETAIL PLAN AND SECTION PLUG VALVE AND BOX DETAIL FRAME AND COVER FRAME AND COVER REVISEDI AUG„1995 (USF 420 TYP.) (USF 420 TYP.) DATE, DWG, FIG, DATE, AUG. 1990 DWG, MHPS FIG, 200 DATE, AUG. 1990 DWG` SERVCONN FIG, 405 DATE, JAN. 1990 DWG' PVBOX FIG, 203 DATE, JAN. 1990 DWG' MHFRAME FIG, 202 DATE, DWG, FIG, 3/17/99 VALCOL 107 JAN. 1990 MHFRAME 202A TRENCH WIDTH VARIES W/ SIZE OF PIPE CROWN TRENCH IN VARIES VARIES TEE CROWN TRENCH IN �- UNIMPROVED AREAS w TRENCH PRECAST ; UNIMPROVED AREAS TRENCH WIDTH VARIES z SET TOP OF VALVE BOX MANHOLE 3' MIN.) LOT LINE WYE WITH _, \j\�\j\\ LIMITS /\/\/\\j /� /� / / /� i� TO FINISHED GRADE WALL / / INFLUENT SEWER (3 MIN. ((SEE TYPE B W SIZE OF PIPE \ \� BEDDING)AND TRENCHING � FINISHED GRADE - - . - ' - SEE NOTE 8) N 6' BRANCH SEWER MAIN � �� `\/ /\\/ DETAIL FOR OTHER w LU ° SIZE VARIES \ CLEAN-OUT \\/\ \/� CONCRETE COLLAR (SEE NOTE 3) RESTORATIQN.) FINISHED GRADE N o BEND (IYP.) 4 BARS ALL AROUND I UNPAVED AREAS /\\ '. •: ' . ::: FINISHED GRADE SEE DETAILS) CONCRETE ENCASEMENT WYE WITH SEE NOTE 1 MIN. 2" CLEARANCE 6" BRANCH CO AROUND PIPE. ' 6 OF VERTICAL PIPE ° ) DROP PIPE CLEAN-OUT REMOVABLE 6" 45 WYE WITH s" MIN. (TYP.) SEE NOTE 1 PLUG BEND 6 BRANCH A INLET CONNECTION (SEE NOTE 1) w N / /� v w w LOT TIE RODS INCLUDING AS REQUIRED 90° BEND W j\\ /\ m o z NUTS AND WASHERS -ADJUSTABLE CAST IRON F`- 2 m o ///� = z x LINE (SEE SCHEDULE BELOW) VALVE BOX -.a.' .. z 6/1\ \ A/1" \� v w Q DOUBLE 4" x 4" x 1/2" SEE NOTE 2 SEE NOTE 4 , /�//r cn w N /�` / SEE NOTE 4LANE BEARING PLATE MECHANICAL // /\ :: \ //. cn (TYP.) -•-I ( C (6" MIN.) JOINTS \/ -- COMMON FILL\ PIPE O.D.- * /\ COMMON FILL. �/ - / / . PLAN BOX SHALL REST ON PRECAST PIPE o:D. // / /\\ \\/\ _ #4 BARS RESILIENT SEAT BEDDING ROCK NOT STANDARD DROP DETAIL MANHOLE \//\ FINISHED GRADE _ M. J. GATE VALVE ANDVSHALL BEPIPE TRANSITS COLLAR ENCASED WALL \ \ - CENTERED ON IN NON -SHRINK GROUT 12" TYP. %\ ' : /\ c� r WATER 12" (11 P.) /\/ ' /�� SELECT ( ) SELECT z SLOPE TO i,�\/\\j\\/\' MAIN OPERATING NUT FLUSH WITH MANHOLE WALL PVC OR DIP o w UNDISTURBED / /. ( ) \ /�� COMMON z \ \\ COMMON o I- TERMINAL I: \/\\/�\/ - \ \ \ \ \ \ ° o • ° °o SEE NOTE 2 o w / / i w o t_ \ DEPTH AT \ :. EARTH :\i / :/i�i�/ ° , \ /// FILL Luo // //\ FILL m z MIN. D 4'-0" MIN. ° ..,o ° °D SELECT COMMON z \ 1.0% °°°.°°°•°° 0 0 0 o UNDISTURBED \ w w ENCASE TIE RODS ( ) SEE TRENCH DETAILS ° ° ° FILL \//OoOo Ooh �� w W / CL 'll (TYP.) IN 1-1 2" PVC SLEEVE FOR PIPE BEDDING _ °o• °°.°°°. BEDDING ROCK :/\ $ o0 opQpo° /� w EARTH 3) /\ \ `� 3" COVER O U Onn , cn \ \ REQUIREMENTS °° .0.PRECAST PIPE BEDDING 0 00 \ (SEE NOTE 8 & 9) �/\//�y//UNDISTURBED EARTH ��� \ \\ \ �\ \ \ \ \ \ %/�//�//�//�//�//�//�//�� ROTATE TERMINAL DEPTH 30° (71 P.) SPRING LINE SIZE (INCHES) A B C D DIA. NOTES: AS REQUIRED FOR (SEE NOTE 3) SEWER MAIN Ln TOP OF THE PIPE. 1. PIPE BEDDING: SELECT COMMON FILL COMPACTED TO 95% OF THE 'HOUSE" SERVICE n NOTES: MAXIMUM DENSITY AS PER AASHTO T-180.( 3 MIN.)( TYP.) NOTES: 1. PIPE BEDDING: SELECT COMMON FILL COMPACTED TO 95% OF THE 2. TRENCH BACKFILL: COMMON FILL COMPACTED TO 95% OF THE SINGLE DOUBLE NOTES: MAXIMUM DENSITY AS PER AASHTO T-180. MAXIMUM DENSITY AS PER AASHTO T-180. ='°°°'°°°'°°°'°°°' °'°�°'° "°°°'°'°'°°°'°°°'°°°'°°°'°'o,., °°°°'°°°°°o�°°as"°a�°' 1. ADDITIONAL REINFORCEMENTS SHALL 2. TRENCH BACKFILL: COMMON FILL COMPACTED TO 95% OF THE 3. PIPE BEDDING UTILIZING SELECT COMMON FILL OR BEDDING ROCK IN LATERAL LATERAL BE AS SPECIFIED BY THE ENGINEER. MAXIMUM DENSITY AS PER AASHTO T-180. 3. USE TYPE A BEDDING TO BE DETERMINED IN THE FIELD AS DIRECTED ACCORDANCE WITH TYPE A BEDDING AND TRENCHING DETAIL MAY BE ( 2. MINIMUM COMPRESSIVE STRENGTH BY THE CITY. REQUIRED AS DIRECTED BY THE CITY. 4. (*): 15" MAX. FOR PIPE DIAMETER LESS THAN 24", AND 24" MAX. PROFILE FOR CONCRETE SHALL BE PSI. 4. (*): 15" MAX. FOR PIPE DIAMETER LESS THAN 24", AND 24" MAX. FOR PIPE DIAMETER 24" AND LARGER. PVC 3. BEDDING, BACKFILL, AND COMPACTION FOR PIPE DIAMETER 24" AND LARGER. 5. WATER SHALL NOT BE PERMITTED IN THE TRENCH DURING CONSTRUCTION. w SHALL BE AS SPECIFIED ELSEWHERE 5. WATER SHALL NOT BE PERMITTED IN THE TRENCH DURING CONSTRUCTION. 6. ALL PIPE TO BE INSTALLED WITH BELL FACING UPSTREAM TO THE NOTES: IN THE STANDARD DRAWINGS. 6. ALL PIPE TO BE INSTALLED WITH BELL FACING UPSTREAM TO THE DIRECTION OF THE FLOW. 1. CLEAN-OUT (SHOWN SHADED) SHALL BE INSTALLED BY THE BUILDER 4. ALL FORM BOARDS SHALL BE REMOVED DIRECTION OF THE FLOW. 7. REFER TO SECTION 32.5 OF THE MANUAL FOR SHEETING AND BRACING IN ACCORDANCE WITH STANDARD PLUMBING CODE. PRIOR TO BACKFILL. 7. REFER TO SECTION 32.5 OF THE MANUAL FOR SHEET LNG AND BRACING IN EXCAVATIONS. 2. LOCATE SINGLE LATERAL AS CLOSE TO 'LOT LINE AS POSSIBLE, 5. NO ALLOWANCE SHALL BE MADE FOR IN EXCAVATIONS. 8. GRAVITY SEWERS SHALL UTILIZE TYPE A BEDDING, IF REQUIRED BY THE 8. FINAL RESTORATION IN IMPROVED AREAS SHALL BE IN COMPLIANCE WITH 25' MAXIMUM. i FRICTION BETWEEN THE PIPE WALL ALL APPLICABLE REGULATIONS OF GOVERNING AGENCIES. SURFACE 3. INVERT OF SERVICE LATERAL SHALL NOT ENTER SEWER MAIN AND THE THRUST COLLAR. CITY. BEDDING DEPTH SHALL BE 4" RESTORATION WITHIN CITY OF OCOEE RIGHT-OF-WAY SHALL COMPLY WITH PING LINE P P S I SCHEDULE OF DIMENSIONS AND MATERIALS * PIPE DIMENSIONS TIE RODS REO'D SIZE (INCHES) A B C D DIA. O PARENTHESES OR INCREASE THE GIVEN VALUE BY A FACTOR°° Ln TOP OF THE PIPE. a°o°°o•o°°, Oa BOTTOM OF BOLTS AND TOP OF SHEAR PAD n OF 1.5. • 4. EARLY WARNING TAPE IS REQUIRED IN ADDITION TO LOCATING NOTES: " >°°•°°°•°°-•°°°•° SHALL BE 6 MINIMUM. * TO BE COMPLETED BY THE ENGINEER. o Q z WIRE AT DIRECTION OF CITY. 1. ANCHORING TYPE 90° BEND SHALL ONLY BE USED WHERE RIGHT-OF-WAY ='°°°'°°°'°°°'°°°' °'°�°'° "°°°'°'°'°°°'°°°'°°°'°°°'°'o,., °°°°'°°°°°o�°°as"°a�°' E-R..',T BLOCK AREAS TO BE COMPUTED ON BASIS OF PER SQ. FT. SOIL RESTRAINT COMPLETED BY ENGINEER. (1,500 MIN)NG. SEE NOTE5BE MANHOLE 'o'.°°°. °°.°°°.,°°. °°• ^o. °°.°°°.°°°• WALL SPECIAL DETAIL FOR 24" DIAMETER PIPE AND LARGER 6" BEDDING ROCK STAINLESS STEEL PVC OR BAND DIP STAINLESS STEEL PIPE CLAMP i RESILIENT CONNECTOR STANDARD PRECAST MANHOLE NOTES: PIPE CONNECTION 1. PVC EXTENSIONS SHALL NOT BE USED ON VALVE BOX INSTALLATION. NOTES: 2. THE ACTUATING NUT FOR DEEPER VALVES SHALL BE EXTENDED TO 1. DROP PIPE AND FITTINGS SHALL BE OF EQUAL SIZE AND MATERIAL AS COME UP TO 2 FOOT DEPTH BELOW FINISHED GRADE. THE INFLUENT SEWER. 2. THE CITY MAY APPROVE ALTERNATE WATER TIGHT CONNECTION DETAILS MINIMUM FOR PIPE DIAMETER LESS THAN REQUIREMENT OF RIGHT-OF-WAY BELOW S R 6. DESIGN RESSURE._ FOR CONNECTION OF 24" DIAMETER PIPES AND LARGER. 15", AND 6" MINIMUM FOR PIPE P 3. AN OUTSIDE DROP CONNECTION SHALL DIAMETER 16" AND LARGER. CITY OF OCOEE UTILITIES DEPARTMENT UTILIZATION REGULATIONS AND CITY OF OCOEE UTILITIES DEPARTMENT CITY OF OCOEE UTiUTIES DEPARTMENT CITY OF OCOEE UTILITIES DEPARTMENT CITY OF OCOEE UTiUTIES DEPARTMENT BE REQUIRED FOR ALL INFLUENT CITY OF OCOEE UTIUTiES DEPARTMENT 9. DEPTH FOR REMOVAL OF UNSUITABLE ROAD CONSTRUCTION SPECIFICATIONS. LINES WHICH HAVE AN INVERT 2' OR MATERIAL SHALL GOVERN DEPTH OF TYPE A BEDDING TYPE B BEDDING WATER MAIN MORE ABOVE THE MANHOLE INVERT. BEDDING ROCK BELOW THE PIPE. AND TRENCHING DETAIL SERVICE LATERAL DETAIL THRUST COLLAR DETAIL GATE VALVE AND BOX DETAIL MANHOLE CONNECTION DETAILS CITY SHALL DETERMINE IN THE AND TRENCHING DETAIL FIELD REQUIRED REMOVAL OF UNSUITABLE MATERIAL TO REACH DATE, DWG, BBEDD FIG, 100 DATE, AUG. 1990 DWG, WW FIG, 204 DATE, DWG, COLLAR FIG, 105 DATE, AUG. 1990 DWG' GVBOX FIG' 400 DATE+ DWG, MHCON FIG, 201 MINIMUM LENGTH (FT) TO BE RESTRAINED ON EACH SIDE OF FITTING(S). * DOUBLE SINGLE HYDRANT OPERATING NUT HOSE NOZZLE LOTS (TYP.) SERVICE (TYP.) SERVICE (TYP.) AS REQ'D. UNDISTURBED PLS FOR 24" SQUARE QR SOIL (TYP.) ��� TEE EA FOR PIPE SIZE METALLIC LOCATING WIRE EARLY WARNING TAPE - - - ROUND AND 6 THICKPUMPERNOZZLE 6" 8" 10" 12" FINISHED GRADE PROPERTY REINFORCED CONCRETE ACINGSTREET WOOD BACKFLOW PREVENTER LINE (TYP.) - EDGE OF BLOCKING - VALVE COLLAR ° IN ACCORDANCE WITH //\//\//�\//\ /\//�//�\; NOTE 1 TRENCH (TYP.) 90 BEND 25 32 39' 45 PLANS APPROVED BY �j \\/' 2 - 4 AT 9" z (TYP.) THE CITY \ //� (SEE DETAIL) AREA FOR ° GATE VALVE//\ //\�� I AROUND PLUG 45 BEND 10 13 16' 19 / \; 1 MAX. i ao cRoss w/PLuc CROSS w 22-1/2° BEND 5' 6' 8' 9° TEST COCK (T)P.) \ /. / I I •: , x GATE VALVE �\ ® TWO PLUGS � TEE TEE W PLUG THREADED UNION j WATER MAIN NIPPLE TYP. 2 REQUIRED % \� PVC WATER MAIN 6" MINIMUM BACKFILL W M J HYDRANT BELL SHALL NOT INTERFERE 11-1 4° BEND 2' 3' 4' 4' (TYP.) ( ) \ COMPACTED / WOOD FORM BOARDS BEHIND WITH JOINT (TYP.)AREA FOR AREA FOR PLUG OR BRANC (2 °REQUIRED) j\\ \ \ \ \ \ OR FORCE MAIN _ _ SEE NOTE 2 A Q VARIES ANCHORING TE coNCRErE THRUST T '/ B �j `� BEND TEE OF TEE ¢ %\/\/\/\/\/\/. > BLOCK (TYP.) B/2 JA FINAL GRADE METALLIC LOCATING WIRE AREA FOR NOTES: I 4�� I �1" MAX.11LEDGE OF 1. FITTINGS SHALL BE RESTRAINED JOINTS UNLESS OTHERWISE TRENCH PLUG 18" DIAMETER BY 6" , T \ °o.oV°.o• o.° °.° o.o °• ° °° ° °.° ! f?�l () TEE W/ INDICATED. ` .° °.° °A°°o.° o.o o.°°°* o. °°.° ;°°o 2. INSTALL FULL LENGTH JOINTS WITH TOTAL LENGTH EQUAL TO - ( ° °°°.° °• ° • °°• ' OR 18" x 18 x 6 \, WYE END PLUG CONCRETE COLLAR REDUCER OR GREATER THAN SHOWN IN THE TABLE. FROM WITH 4 BAR ALL TO 4" WATER 6" BEDDING ROCK BENDS 3. WHERE TWO OR MORE FITTINGS ARE TOGETHER, USE FITTING MAIN AROU D (2 REQ'D.) SERVICE MAIN (MIN.) 6" FIRE HYDRANT WHICH YIELDS GREATEST LENGTH OF RESTRAINED PIPE. \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ RESILIENT SEAT GATE 4. IN LINE VALVES AND THROUGH RUN OF TEES OUTSIDE LIMITS ���/�/��/��/�/��/�/i�/�/i�/�/�/�/'���' FITTINGS AS OFFSET (As REo'D) ASSEMBLY VALVE AND BOX OF RESTRAINED JOINTS FROM OTHER FITTINGS NEED NOT BE REQUIRED (TYP.) (SEE NOTE 1 STANDARD INSTALLATION EDGE OF CROSSCUT (SEE DETAIL) UNDISTURBEDo( RESTRAINED UNLESS OTHERWISE INDICATED. 5. LENGTHS SHOWN IN THE TABLE HAVE BEEN CALCULATED IN RIGHT OF WAY LINE TRENCH WIDTH _ ACCORDANCE WITH THE PROCEDURE OUTLINED IN "THRUST NOTES: THRUST = RESTRAINT DESIGN FOR DUCTILE IRON PIPE" AS PUBLISHED NOTES: NOTES: CURB 1.THE DEVELOPER MAY THRu BLOCK BY DIPRA, WITH THE FOLLOWING ASSUMPTIONS: 1 �' PIPE FT>T� 1. PVC PIPE SHALL REQUIRE INSULATED METALLIC LOCATING WIRE WATER MAIN FITTING MIN. AREA SQ. FT.) NOTES: THRODED 9CNEDINF 40 G&,VMM STEM OR BRASS, INSTALL THE SHEAR PAD CONCRETE 1. THRUST BLOCK BEARING AREAS SHALL BE POURED AGAINST (14 GAUGE COPPER) CAPABLE OF DETECTION BY A CABLE LOCATOR 2' (TYP.) RECESSED UP TO 4" THRUST BLOCK UNDISTURBED MATERIAL. WHERE TRENCH WALL HAS BEEN WORKING PRESSURE: ___-----___ P.S.I.* 2. AND SHALL BE BURIED DIRECTLY ABOVE THE CENTERLINE OF THE PIPE. DISTURBED, EXCAVATE ALL LOOSE MATERIAL AND EXTEND SOIL DESIGNATION: --____ LOCATING WIRE SHALL TERMINATE AT THE TOP OF EACH VALVE BOX BELOW FINISHED GRADE TO UNDISTURBED MATERIAL. __--__--__ * °° • ° o0 00 "o . o ° „° • ° � ° _ ° • TYPICAL SECTION 2. EXTEND THRUST BLOCK FULL LENGTH OF FITTINGS. LAYING CONDITIONS: ______ * 3. AND BE CAPABLE OF EXTENDING 12" ABOVE TOP OF BOX IN SUCH A SIDEWALK (TYP.) • ° °° • °' ° ° • ° °° • o °° • ° ° AND SOD THE RECESSED JOINTS SHALL NOT BE COVERED BY THRUST BLOCKS. °' °"°° SECTION. � • o °oe°° ° • ° e° °O i ° °O • ° °' FITTINGS SHALL BE PROTECTED BY POLYETHYLENE FILM 6. FOR PIPE ENCASED IN POLYETHYLENE, USE VALUES GIVEN IN MANNER SO AS NOT TO INTERFERE WITH VALVE OPERATION. USE DUCT TAPE AS NECESSARY TO HOLD WIRE DIRECTLY ON THE RIGHT OF WAY LINE ��° ` "� :o 0 0 0 0' o � 2.CLEARANCE BETWEEN • ° °°°°•°°°� O PARENTHESES OR INCREASE THE GIVEN VALUE BY A FACTOR°° Ln TOP OF THE PIPE. a°o°°o•o°°, Oa BOTTOM OF BOLTS AND TOP OF SHEAR PAD n OF 1.5. • 4. EARLY WARNING TAPE IS REQUIRED IN ADDITION TO LOCATING NOTES: " >°°•°°°•°°-•°°°•° SHALL BE 6 MINIMUM. * TO BE COMPLETED BY THE ENGINEER. o Q z WIRE AT DIRECTION OF CITY. 1. ANCHORING TYPE 90° BEND SHALL ONLY BE USED WHERE RIGHT-OF-WAY ='°°°'°°°'°°°'°°°' °'°�°'° "°°°'°'°'°°°'°°°'°°°'°°°'°'o,., °°°°'°°°°°o�°°as"°a�°' CONSTRICTIONS WILL NOT ALLOW INSTALLATION OF A STRAIGHT ASSEMBLY. L4 -J p CITY OF OCOEE UlIU71ES DEPARTMENT CITY OF OCOEE UTiUTiES DEPARTMENT CITY OF OCOEE UTiUTIES DEPARTMENT CITY OF OCOEE UTWTIES DEPARTMENT CITY OF OCOEE UTILITIES DEPARTMENT RESTRAINED PIPE TABLE. PVC SECTION A_A w REDUCED PRESSURE' LOCATINGPE WIRE WATER SERVICE LOCATION DETAIL FIRE HYDRANT ASSEMBLY DETAIL -W v L4mJIII,mm BACKFLOW PREVENTER DETAIL PIPE 90 45 22-1/2 17-I/4 TEE & DESIGN SIZE BEND EItAO BEND BEND PLUG PRESS (RICHES) (SQ FT) (SO FT) (SO F,7 (SO FT) (50 Fh (PSI) 6 10 12 iFRJST flDIX MEAS TO BE taIriRED W 8.145 Oi sa rt, we aLslRuvr �'SONDi� • TO BE COMPLETED BY ENGINEER. (8 MIL) PRIOR TO PLACING CONCRETE THRUST BLOCK. 3. ROUGH BLOCKING FORMS SHALL BE USED ALONG SIDES OF THRUST BLOCKS, AS REQUIRED. 4. THRUST BLOCKS SHALL BE USED IN COMBINATION, AS REQUIRED, TO SUITE THE SPECIFIC FITTING ARRANGEMENT. 5. ALTERNATE DESIGNED RESTRAINING SYSTEMS SHALL BE PROVIDED WHERE STANDARD THRUST BLOCKING IS NOT SUITABLE AND/OR SOIL RESISTANCE BEARING IS LESS THAN 1500 PSF. 6. ALL WOOD BLOCKING SHALL BE PRESSURE TREATED WITH PRESERVATIVE. CITY OF OCOEE UTILITIES DEPARTMENT THRUST BLOCK DETAIL DATE'AUG. 1990 DWG PIPETAB FIG, 104 DATE, AUG. 1990 DWG, BPSS FIG, 501 DATE, 3/17/99 DWG INSTALL FIG, 108 DATE, AUG. 1990 DWG' SERVDEAD FIG` 404 DATE13/17/99 DW�t FH FIGt 402 FIG 103 i O 210 OD W L0 m t� F Z P I Z ® CC 0 IL �► CJ ® c� CC ® IL I ®� W INC Z o < O 0 V' O 0 0 V � 4... e.✓ Z 0 .0 T� tl,IL0 J ®.1 Y) Z � F DRAWN: ET CHECKED: TT DATE: OCTOBER 2005 SCALE: MTS CAD NAME: UTILITY DETAILS JOB #: 11004 SHEET #: OF 9 SHEETS Ito co O Ln a 1P n ^ v z • 0 do Roo 00 t� N o Q z L4 -J p �L L4 LIJ a t1 ■ w 7 0 -W v L4mJIII,mm k s � CC 9- 0 0 0 F= O 210 OD W L0 m t� F Z P I Z ® CC 0 IL �► CJ ® c� CC ® IL I ®� W INC Z o < O 0 V' O 0 0 V � 4... e.✓ Z 0 .0 T� tl,IL0 J ®.1 Y) Z � F DRAWN: ET CHECKED: TT DATE: OCTOBER 2005 SCALE: MTS CAD NAME: UTILITY DETAILS JOB #: 11004 SHEET #: OF 9 SHEETS O o� a 1P n ^ v z • 0 do Roo 00 t� N o Q z L4 -J p �L LIJ t1 ■ 7 0 -W v L4mJIII,mm LLI � CC 9- 0 10 O 210 OD W L0 m t� F Z P I Z ® CC 0 IL �► CJ ® c� CC ® IL I ®� W INC Z o < O 0 V' O 0 0 V � 4... e.✓ Z 0 .0 T� tl,IL0 J ®.1 Y) Z � F DRAWN: ET CHECKED: TT DATE: OCTOBER 2005 SCALE: MTS CAD NAME: UTILITY DETAILS JOB #: 11004 SHEET #: OF 9 SHEETS 19111111 . 1. IN ORDER TO ENSURE THAT AS MANY EXISTING TREES AS POSSIBLE WILL BE PRESERVED, ALL ROAD RIGHT—OF—WAYS AND RETENTION AREAS WILL BE FLAGGED FOR REVIEW BY THE CITY AND THE ENGINEER PRIOR TO ANY TREE REMOVAL. NO CLEARING PERMITS WILL BE ISSUED FOR SITE WORK OR BUILDING CONSTRUCTION UNTIL ALL TREES TO BE PRESERVED HAVE BEEN CLEARLY MARKED WITH TREE PROTECTION BARRIERS. 2. ALL TREES TO BE PRESERVED SHALL BE CLEARLY MARKED WITH TREE PROTECTION BARRIERS PRIOR TO ANY CLEARING OR CONSTRUCTION. SEE TREE PROTECTION DETAIL SHOWN ON SHEET 6 ng, a B„PVC STORM MANHOLE _N. RIM-- 168.90 / INV.=157.49 I SAN(?ARY SEWER MANHOLE 52"CMP N. RIM=168.90 11IV.=157.49 III �� / � � --�•...f6� 0�``-� TAX PARCEL 013 I I I (Not Platted) . 9.0,� ASPHALT DRIVE 5CONC S/W 1VOOD, POWER POLE (TYP.) TELEPHONE RISER —_ _ _I L— %I II I a�C� 0�� _ ----• ___ 1 6 _ 10' WALL, LANDSCAPE CONCRETE "_ AND SIGN EASEMENT ' I i� ..' DRIVE ( 2 ► i I gO 6' BRICK WALL a 04 C.? F.:AiL90K ✓I✓I I t PLANTER I i LOT 62 R-1 o II 00 I I I p SINGLE FAMILY RESIDENTIAL WATER Iv o) mEIFER TAX PARCEL 071 (Not Platted) N 89033'16"E 590.40' o• 90• �o• 1� GRAPHIC SCALE 30 0 15 30 60 ( IN FEET ) 9 inch = 30 ft. TREE ABBREVIATIONS CA. DENOTES CAMPHOR 0. DENOTES OAK WC. DENOTES WILD CHERRY. TREE SIZES ARE SHOWN IN INCHES. R-3 � MU / ASPHALT 1 $?Vf j{ M Y1�1L{Ly` Ldik�CAPI:y lF I PAVEMENT ra AF�I'� it3N ASE tIEIit 2' MIAMI 152 -CMP ��r�a�Ji . , ' r.�/ ,i• CURB % �� ... r r j i „ r y” �.rF, ( ur-�.* f . . f ..:.v �✓ zz ®SITE BENCHMARK #9 � --LEVATION 168.-L5 NORTH RIM OF SANITARY SBVER MANHOLE STORM MANHOLE N. RIM=168.63 3 ( I • . ^ 1� yr e� s N. RIM=.1=15158.98 Iw/ Inl,/ ...1lr7Aw..w �w.-1.v.. _. I _4 ,.,..' ...,• .,., r .,;, .... >`-., . r , -; ... _ .._ .. .O ; ; CC) I �J Ptd II ro k ° f� O 1 % I � I 1 ; e 4 1 I S!r`BENCHMARK 2 LEVATION 167,81 X 4" C.M. (Ni a 00 1 lb Z 0 1 4 0 i N o00 di MM Z o Q) �.0 irri r r lu cc W uUui z i� 0 �% O �' O W O. Q .O ; ; CC) I �J Ptd II ro k ° f� O 1 % I � I 1 ; e 4 1 I S!r`BENCHMARK 2 LEVATION 167,81 X 4" C.M. (Ni a 00 � LL v j B1( DEVELOPER) d I LESS OUT POND 1 " i I Q it '.� ti 10 X, ( X PARCEL 0230 TRACT a �a:40 aG) xn 9 i 1 6 II Platted I 170.0 - ,,)(Not ) G -- R-1 ORANGE COUNTY L ,o I SINGLE FAMILY RESIDENTIAL f z i�, I I -- -- --- ----169.5_ _ _ ___ .-•'' ,�° °.� ._._...____<..._<__.<,<._._ .fib«<_<._.__ ,� ;° P N10•� ° IIS �� S 89033'16"W 363.30' 0°- �o III I I`•. _._- _ AQP _ ---169.0 - __QPM ,`� �� N - I -PCF 076 ____.169.0---... .Y --o 3� — - -__ �R-1 ORANGE COUNTY II (Not Platted) ��� VA&41T..R.ESIDENTIAL _--------------------------- --_—=__---=__—__—= —=_____________------- --- — ' '--" ---166.5---•-• TAX PARCEL 081 -ROBS®RERs0N-�- 169.0—_ — -� '� /> ASPHALT PAVEMENT V FLAT CONCRETE CURB (TYP.) � STORM MANHOLE Not --Pka t -e d------------ _________________________________ ` w i INV.=' 160.13 I I I II I I I I I I I I I I i I i I I I I I i i I I rt- 1 _1C Z ® 4 0 i N o00 di MM Z o Q) �.0 ,. ■■ w lu cc W uUui z 0 �% O �' O W O. Q CM Q4 O Z I� _ -..-169.0--- ---- o 0 c� � LL v j B1( DEVELOPER) d I LESS OUT POND 1 " i I Q it '.� ti 10 X, ( X PARCEL 0230 TRACT a �a:40 aG) xn 9 i 1 6 II Platted I 170.0 - ,,)(Not ) G -- R-1 ORANGE COUNTY L ,o I SINGLE FAMILY RESIDENTIAL f z i�, I I -- -- --- ----169.5_ _ _ ___ .-•'' ,�° °.� ._._...____<..._<__.<,<._._ .fib«<_<._.__ ,� ;° P N10•� ° IIS �� S 89033'16"W 363.30' 0°- �o III I I`•. _._- _ AQP _ ---169.0 - __QPM ,`� �� N - I -PCF 076 ____.169.0---... .Y --o 3� — - -__ �R-1 ORANGE COUNTY II (Not Platted) ��� VA&41T..R.ESIDENTIAL _--------------------------- --_—=__---=__—__—= —=_____________------- --- — ' '--" ---166.5---•-• TAX PARCEL 081 -ROBS®RERs0N-�- 169.0—_ — -� '� /> ASPHALT PAVEMENT V FLAT CONCRETE CURB (TYP.) � STORM MANHOLE Not --Pka t -e d------------ _________________________________ ` w i INV.=' 160.13 I I I II I I I I I I I I I I i I i I I I I I i i I I rt- � Z ® 4 0 i N o00 w MM Z o I M p ,. ■■ w lu cc W uUui z 0 �% O W O. Q CM Q4 =Q z Z F® � o 0 0 Z a r _>L4 -J p ® W a oa � LCLL1- ® MY u - U N Z ® o00 w �- o: ,. ■■ w O0 z 0 �% W Q CM Q4 =Q z Z F® � o 0 0 r U N Z ® o00 �- a8 N ,. ■■ O0 z 0 �% L� CM Q4 =Q z Z F® � r _>L4 -J p ® N LCLL1- ® MY u - M■ ®�- L4J v 0.4 -4 " C LID Lm4J ui LID O V. t�A I �s- p Z Ic 1116 < C2 MM SIO ;w 0 Z �„ ► ® ® 2 CC ® E' IL ®go R cc IL A S z 0 A06(� z z O m � IL 01 p t IL W W It 0 r It DRAWN: ET CHECKED: TT DATE: OCTOBER 2003 SCALE: 1"=$0' CAD NAME: TREE PROTECTION JOB #.- 11004 :11004 SHEET #: OF 9 SHEETS 1-11 z O v W th z O i•u tu POLE (TYP.) TrLEPHONE RISER J IL W F_ND OF FENCE L Y A—II\Li.—It r.,I :I �w i./ GOMMUN I TY ENTRY 51 ONAOE SCALE: nts NOTE WALL TO BE 6MINIMUM HEIGHT "Ar—ASURED FROM FINISH GRADE ON WHICHEVER SIDE OF THE WALL 15 HIGHER, RFON ' �R BACK. y°. �Y m'qv Poor WILL_ cOW,Wl m M.4anm ll u" w rRevmr 9etnim4ma . X31°. "•GCS,', Lo Or ' j1 fes`. S 89033'16"W 363.30''' it �s}.y�+i+rts ,`6 ��, l:�rj- .,,• � 1` a_`, 4r d� •�.. ............_ I FL",;' l':ONCRETE CURB (T -O'.) IW. 60.1 L BOB SORENSON LANE ''o. 30 0 10 30 1 inch = 30 ft. GRAPHIC SCALE PLANT LIST QTY. SYM. BOTANICAL NAME COMMON NAME SIZE TREES 6 QV QUERCUS VIR&INIANA LIVE OAK 10'-12'; 5' SPREAD; 3"" DBH 4 LJ LIGUSTr'�UM JAPONICUM TREE FORM LIGU5TRUM 8'-10'f6' 5PREAD; 2"-2.5"D514 SHRUBS RI RAPHIOLEPIS INDICA INDIAN HAWTHORN 15"X1511; 2.5' OG GROUNDCOVER 200 LV LIRIOF'E VARIEGATA AZTEC GRASS FULL GLS.; 24" OG AMFORM re IUZM'rAI%M SHRUB PLANTING DETAIL TREE STAKING DETAIL >MOmmas tb meavtw mWAY l %mv "nwo Tmw R1 aM/! ,weKm ammAism om "m "r ,1/YI'0W rTimXe TI ULM "Tit"a ouTm wa "Aa lomf m= suck somal Hage MWALM A-WAN=MM" 1lft! ARVQ! TM�!lCIIRiY 1Y1l/Qm Y dYICe! A�Pl'IOIN RllRi>ml TldJsl'! —11: -11.11 i i�i�i�i i iii � i'� i 1 �"�1•=.II j 'II -11-11 �� •ii�i�i�i���i0ii ll�� , il.11.!I C ENERAL LANDSCAPE NOTES I. ALL PLANTS TO BE FLORIDA NO. I, OR BETTER AS OUTLINED UNDER '&RAVES AND STANDARDS FOR NURSERY PLANTS, PART I, 1963 AND PART 11, STATE OF FLORIDA DEPARTMENT OF ASRICULTURE, TALLAHASSEE, FLORIDA, AND ANY AMENDMENTS THERETO. 2. ALL TREES AND PLANT MATERIAL SHALL BE PLANTED IN AGGORDANCE WITH THE SPECIFICATIONS DESCRIBED IN THEN STATE DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES, DIVISION OF FORESTRY, "TREE PROTECTION MANUAL FOR BUILDERS AND DEVELOPERS", OCTOBER, 1980. 3. THE LANDSCAPE CONTRACTOR (CONTRACTED BY OWNER, N.I.G) SHALL BE RESPONSIBLE FOR ALL MATERIALS AND ALL WORK AS GALLED FOR ON THE LANDSCAPE PLANS. THE LIST OF PLANT QUANTITIES ACCOMPANYINS THE PLANS SHALL BE USED AS A GUIDE ONLY. IF A VARIATION OCCURS BETWEEN THE PLANS AND THE PLANT LIST, THE PLANS SHALL CONTROL. 4. ALL TREES, SHRUBS AND &ROUND COVERS SHALL BE PLANTED USING A SOIL MIXTURE PREPARED ACCORDINGLY (2/3 EXISTINS SOIL, 1/5 PEAT). 5. THE LANDSCAPE CONTRACTOR SHALL INSURE ADEQUATE VERTICAL DRAINA&E IN ALL PLANT BEDS AND PLANTERS. VERTICAL DRILLING THROUGH ANY COMPACTED FILL TO NATIVE SOIL SHALL BE AGGOMIOLISHW TO AID DRAINASE. 6. ALL PLANT BEDS AND TREE WATERING BASINS SHALL BE TOP DRESSED WITH THREE INCHES (3") OF SHREDDED CYPRESS MULCH. 1. NO TREES SHALL BE PLANTED CLOSER THAN 5 FEET (39 FROM THE EDGE OP PAVEMENT TO ALLOW ADEQUATE TREE TRUNK PROTECTION . 6. LANDSCAPE CONTRACTOR SHALL BE WHOLLY RESPONSIBLE FOR STABILITY AND PLUMB CONDITION OP ALL TREES AND SHALL BE LESALLY LIABLE POR ANY DAMA&E CAUSED BY THE INSTABILITY OF ANY PLANT MATERIAL. 9. ALL LAWN AREAS TO RECEIVE SOD SHALL BE DISKED FOUR(4) TO SIX(6) INCHES AND DRA66E0 TO ESTABLISH A LEVEL FINISH GRADE. ALL DEBRIS TO BE REMOVED FROM THE SITE. 10. SOD SHALL BE FREE OF WEEDS AND PESTS. IT SHALL BE LAID EVENLY AND ROLLED, WITH TIGHT FITTING JOINTS. THE SOD SHALL CONTAIN MOIST SOIL WHICH DOES NOT FALL APART OR TEAR WHEN LIFTED. ALL AREAS NOT PAVED OR OTHERWISE LANDSCAPED SHALL BE SODDED. SOD SHALL BE ARGENTINE BAHIA OR EQUAL. II. ALL LANDSCAPE AREAS TO BE IRRIGATED WITH AN AUTOMATIC UNDERGROUND SYSTEM, WITH 100% COVERASE,BACKFLOW PREVENTOR, 4 RAIN SENSOR DEVICE. DIRECT SPRAY HEADS AWAY FROM ANY NATURAL AREAS AND PAVED SURFACES. 12. THE TREE CALIPER OF ALL TREES SPECIFIED ON THE PLANT LIST SHALL BE AT LEAST TWO (2) INCHES IN DIAMETER WHEN MEASURED AT FIFTY POUR (64) INCHES ABOVE &RADE. } J > M2 w r J co '' uj ��eWs1 9L ii o cc ® 4 in � ++ CC eu o cos U. �� be o o a ti c � V } r J co '' uj :v ++ • U. �� Ca a ti f