Loading...
Item #03 Approval of Suntree Technologies Baffle Box - Flewelling Avenue Drainage System111k*c %/� 0C:0(? florida AGENDA ITEM COVER SHEET Meeting Date: February 4, 2014 Item # r Contact Name: Stephen C. Kru Contact Number: 6002 Reviewed By Department Director: City Manager: Subject: Suntree Technologies Baffle Box — Flewelling Ave. Drainage System. Commissioner Wilsen, District 2. Background Summary: The Spring Lake drainage basin collects storm water from a large upland area along Flewelling Avenue. Flewelling Avenue acts as the spine of the collector system bringing drainage east to Spring Lake. The existing drainage system piping between Ridgefield Drive and the lake has deteriorated over time requiring replacement to restore proper water flow and relieve flooding. The Stormwater Division performed a drainage study of the occasional flooding in this area and produced an in -house designed solution that has been approved by SJRWMD. Part of the design is providing a baffle box treatment system for the stormwater flowing from the upland area before it enters Spring Lake. The existing drainage does not provide any stormwater treatment as it discharges directly into the lake. The Stormwater Division reviewed baffle box designs from several vendors, each with a proprietary design that address a specific need in a specific situation. This review process also involved field inspections of existing baffle systems used by other municipalities and their level of product satisfaction. Following a thorough review, it was determined that Suntree Technologies' baffle box design met the project requirements to collect debris, separate nutrients and skim oils from the water. Suntree has a proven history of providing successful proprietary designs that are easily maintained and adhere to the NPDES requirements by the EPA. The City previously installed a similar baffle box by Suntree for the Prima Vista Neighborhood drainage improvements and has been very satisfied with the performance of the unit. Public Works is requesting the Commission approve the purchase of the baffle box system from Suntree in order to expedite the construction process. The installation and additional drainage improvements will be contracted out under a competitive bidding process. Public Works recommends awarding a purchase order to Suntree Technologies, Inc. for the proprietary 9.5' wide x 155 long x 9.5' deep baffle box as described in the attached proposal for a total delivered cost of $51,795.00. The purchase is adequately funded in the Stormwater budget. Issue: Request the City Commission to approve the purchase of a baffle box from Suntree Technologies, Inc. Recommendations: Recommend approval to issue a purchase order to Suntree Technologies, Inc., to provide a baffle box as described in the attached proposal for the Flewelling Avenue /Spring Lake drainage improvements project for a not to exceed amount of $51,795.00. Attachments: Suntree Technologies, Inc., Proposal. Financial Impact: The $51,795.00 is adequately funded in the Stormwater Division's CIP budget under the Wekiva Basin drainage improvements. Type of Item: (please mark with an `x') Public Hearing Ordinance First Reading Ordinance Second Reading Resolution X Commission Approval Discussion & Direction Original Document/Contract Attached for Execution by City Clerk X Original Document/Contract Held by Department for Execution For Clerk's Dept Use: X_ Consent Agenda Public Hearing Regular Agenda Reviewed by City Attorney Reviewed by Finance Dept. Reviewed by ( ) N/A N/A N/A 2 �,.z. z zzr Iz��titc � Izzc °. 798 Clearlake Rd., Suite 2, Cocoa, FL 32922 Ph: 321 - 637 -7552 Fax: 321 - 637 -7554 www.suntreetech.com Proposal 10186 1/9/2014 Order From Ship To City of Ocoee Project: 150 N. Lakeshore Dr. Flewelling Drive Ocoee, FL 34761 Phone 407 - 905 -3100 Fax Sales Rep FOB Ship Via Terms Ordered By PO No LWH Job Site Our Truck Net 30 Qty Description Unit Price Total 1 Nutrient Separating Baffle Box® 51,795.00 51,795.00 Model No: NSBB -8 -14- Flewelling Drive -1 Includes: Nutrient Separating Screen System w/ Lids Enhanced Turbulence Deflector System w/ Flow Spreader SkimBoss Floating Skimmer & Storm Boom System HydroSlide Service System Three 32" USF -120 Rings & Covers H -20 Load Rated Concrete Structure Slope Service Floors Signature P.O. # Date: By signing and returning this proposal to Suntree Technologies, Inc., the specifications and conditions of the proposal are agreed to and acknowledged by the person signing. If a purchase order is required by the buyer, please FAX the purchase order along with Subtotal the signed proposal. Proposal is void if not accepted within 90 days. In additon to its right or rights with respect to defaults $51 , 795.00 hereunder, seller shall have the right to interest on all balances not paid within agreed upon payment period at rate of interest computed by applying a periodic monthly rate of 1.5% to the past due balance. Seller has the right to all collection costs, reasonable 6 % Sales Tax attorneys' fees, whether suit brought or not, includind attorneys' fees on appeal. The venue shall be in Brevard County, Florida. $0.00 $51,795.00 Total vva.va, 1 L. 'O e- Ph: 321 - 637 -7552 www.suntreetech.com Nutrient Separating = affle = o tri x Descri Functional Captures foliage, D Ill g , If C M litter, sediment, phosphates, hydrocarbons... Everything! Turbulence deflectors prevent captured sediment from re- suspending. Hydrocarbons collect in front of skimmer and are absorbed by Storm Boom. Patented `t ►�� H a1ty Nutrient pollutant load is not lost to static water and flushed out at the next storm event. Separating organic matter from the static water prevents bacterial buildup. lI� Tue a ru Evict Hatch Hatch Hatch Vegetation and litter is above the static water and dries out between storm events. With the organic pollutant load separated from the water, the system does not go septic. • B Deflector Skimmer Sediment Sediment During servicing, the screen system hinges off to the side to give easy access to the sediment collected in the lower chambers. 4U F))j2CA&jz IRV Elm (Manm Far k R& dAd&I 4U Hatch Hatch Hatch • A - .� �A1Aili�.�PPPAiAO;♦ , � % � i fv'•, pr� ►i!�!��i�A�.:!i �P�P�� a'ai +�i � I • Deflector -. -. ime -. - Patented `t ►�� H a1ty Nutrient pollutant load is not lost to static water and flushed out at the next storm event. Separating organic matter from the static water prevents bacterial buildup. lI� Tue a ru Evict Hatch Hatch Hatch Vegetation and litter is above the static water and dries out between storm events. With the organic pollutant load separated from the water, the system does not go septic. • B Deflector Skimmer Sediment Sediment During servicing, the screen system hinges off to the side to give easy access to the sediment collected in the lower chambers. 4U F))j2CA&jz IRV Elm (Manm Far k R& dAd&I 4U Nutrient Separating = affle = ox Captured Debris To the right is a photo of the back page of a road atlas being held 10" underwater in a Nutrient Separating Baffle Box. moo yt" After a couple of months with no rain, the water still has no smell and is clear. The sediment can be clearly seen on the bottom, and small fish and critters have established a happy and healthy ecosystem within the structure. If you are reluctant to touch the water in your stormwater filtration system because it is septic, then you have a problem because the next storm event will flush out your system into the environment. To the left is a view of 5790 pounds of sediment collected in a Nutrient Separating Baffle Box just 30 days after installation. To the right is a view of foliage and litter collected within the screen system of a Nutrient Separating Baffle Box. Sizing The Nutrient Separating Baffle Box Because the entire flow is always treated and head loss is so minimal, determining the appropriate size of Nutrient Separating Baffle Box for a project is more often an element of pipe size than flow rate. Model # Inside Width Inside Length Standard Height * Recommended Pipe Sizes N S B B -2 -4 2' 4' 5' 4" to 12" NSBB -3 -6 3' 6' 7' 8" to 18" NSBB -4 -8 4' 8' 7' 12" to 18" NSBB -5 -10 5' 10' 7' 12" to 30" N S B B -6 -12 6' 12' 7' 18" to 36" N S B B -8 -14 8' 14' 8'4" 36" to 54" NSBB -10 -14 10' 14' 8'4" 42" to 60" NSBB -10 -16 10' 16' 10'5" 48" to 72" NSBB -12 -20 12' 20' 11' 54" to 72" Custom sizes are available. *Height can vary as needed 0 Because water flow is not ducted off line for treatment, head loss is minimal and comparable to a large square catchbasin. Because of this, existing stormwater systems can be retrofitted with a Nutrient Separating Baffle Box, without compromising the original design specifications of the existing stormwater system. 0 All structures are load rated for at least H -20. Standard wall construction of the structure is 6" thick steel re- enforced concrete. Concrete wall thickness can be more heavily reinforced and thicker upon request. 0 A wide variety of manhole lids and hatches, and dampers to block off water flow during servicing, can be incorporated into the structure. 0 Screen systems have stainless steel screens bolted into a heavy duty aluminum framework. The screen systems are hinged to give easy access to the lower chambers, and have a wide range of adjustments to accommodate unforeseen variables during installation. Pre - assembly Of The Nutrient Separating Baffle Box Turbulence deflectors are attached to the tops of the baffles with stainless steel bolts. Several bolts per deflector are required. Four brackets, held in place with 4 stainless steel bolts each, secure the screen system to the baffles. The screen system includes a wide range of positional adjustment. .0 Setting The Structure lmgdkdod� OfA MoOrd 9 2e -3affl BOX A Fenn F§OY -ddg hdi%d Gqo uam �ta o 0 0[.l; The hole was dug starting at 10:00am. By 3:00pm the same day, the entire structure was set in place with most of the backfilling done. [L [�IJVC `C0 000 TK&R er antema Because installation is so fast, the risk of washouts when retrofitting existing stormwater systems is dramatically reduced. V o o W Far QMWM BOO affgU 1WCm Step 1: Set lower half Step 3: Put sealant on joint r "v Notice the custom pipe fitting on the inflow end. It is designed to accommodate two 18" RCP side by side. To block off the water flow of submerged or partially submerged pipes during servicing, internal damper systems are available. A Suntree representative is always available to oversee installation to ensure a successful project. D� 798 Clearlake Road, Cocoa, FL 32922 Ph: 321 - 637 -7552 FAX: 321 - 637 -7554 www.suntreetech.com