Loading...
Item #09 Approval of License Agreement between Florida Central Railroad Company, Inc., (FCEN) and the City of Ocoee for Use of FCEN’s Right-of-Way in Conjunction with the Construction of the Downtown West Sanitary Transmission Project`` za ocoee florldo AGENDA ITEM COVER SHEET Meeting Date: February 7, 2017 Item # 9 Contact Name: Charles K. Smith, P.E. Contact Number: 407-905-3159 Reviewed By: Department Director: Ch City Manager: Robert F Subject: License Agreement between Florida Central Railroad Company, Inc. (FCEN), and the City of Ocoee for use of FCEN's right of way in conjunction with the construction of the Downtown West Sanitary Transmission Proiect (North of Silver Star Phase) Background Summary: As part of the new Downtown by the Lakeshore Project the Utilities piece of the project requires access to a portion of the Florida Central Railroad Company, Inc.'s (FCEN) right of way to complete the Downtown West Sanitary Transmission Project. The proposed license agreement will allow the City of Ocoee the authority to enter upon, construct and maintain an underground Forcemain Pipe under FCEN's right of way in the vicinity of Bluford Avenue, Ocoee, Florida sixty feet northeast of Milepost MP-ST 832.9, FDOT Crossing Number 621878V. The City of Ocoee is to install a 20" Forcemain along Bluford Avenue which will require a jack and bore underneath the railroad near the Intersection of Bluford Ave and Rewis St. The License Agreement has been reviewed and approved by the City's Attorney, Dana Crosby -Collier and by the City's Risk Manager. Issue: Should the Mayor and City Commission approve License Agreement between Florida Central Railroad Company, Inc. and the City of Ocoee for access to FCEN's' right of way for installation of forcemain? Recommendations: Motion for Mayor and City Commission to approve License Agreement with an application fee of $720 and an annual licensing agreement of $844.48 increasing annually with CPI. Attachments: 1) License Agreement between Florida Central Railroad Company, Inc. (FCEN) and the City of Ocoee with Exhibit "A" Application for Facility Installation Financial Impact: FCEN requires an initial application fee of Seven Hundred Twenty Dollars $720. The City of Ocoee will pay an annual license fee of Eight Hundred Forty -Four Dollars and 48/100 ($844.48). The license fee will be payable in advance in annual payments on the anniversary date of the proposed License agreement. The fee will increase annually in proportion to the Consumer Price Index. Type of Item: (please mark with an `x') Public Hearing For Clerk's Dept Use: Ordinance First Reading Consent Agenda Ordinance Second Reading Public Hearing Resolution Regular Agenda _ Commission Approval Discussion & Direction X Original Document/Contract Attached for Execution by City Clerk Original Document/Contract Held by Department for Execution Reviewed by City Attorney N/A Reviewed by Finance Dept. N/A Reviewed by O N/A 2 OCOE-61-186 LICENSE AGREEMENT THIS LICENSE AGREEMENT is made and entered into as of this day of , 2017 (the "Effective Date") by and between FLORIDA CENTRAL RAILROAD COMPANY, INC., a Florida corporation with an address of 3001 W. Orange Avenue, Apopka, FL 32703 ("FCEN") and THE CITY OF OCOEE, a municipality of the State of Florida with an address of 150 N. Lakeshore Drive, Ocoee, FL 34761 (the "Licensee"). Preliminary Statement A. Licensee, for the economical and convenient conduct of Licensee's business, desires to obtain from FCEN a license to use a portion of FCEN's right of way leased to FCEN pursuant to a lease agreement between FCEN and CSX Transportation, Inc. (the "CSX Lease"), without establishing, claiming, or possessing any estate or interest therein (the "License"), for the benefit of Licensee. B. FCEN has the right, power and authority to enter into this License Agreement, pursuant to the CSX Lease. C. Licensee desires to construct and maintain an underground force main (the "Pipe") within the License Area, defined below. NOW THEREFORE, in consideration of the mutual promises contained herein the parties agree as follows: GRANT OF LICENSE FCEN hereby grants unto Licensee, its successors and assigns a License, with authority to enter upon, construct and maintain, pursuant to this License, the Pipe under FCEN's right of way in the vicinity of Bluford Avenue, Ocoee, Florida, sixty (60) feet northeast of Milepost MP-ST 832.9, FDOT Crossing Number 621878V, described on Exhibit A, which is attached hereto and incorporated herein (the "License Area"). 2. SUBJECT TO MASTER LEASE AGREEMENT This License shall be subject to the terms and conditions of the CSX Lease, a memorandum of which is recorded at Official Records Book 5098, Page 4983, Public Records of Orange County, Florida. STATUS OF SUBCONTRACTORS For purposes of this Agreement, all references to Licensee shall include Licensee, its contractors, subcontractors, agents, officers, employees and others acting under its or their authority. 4. USE Licensee shall use the License Area for the construction, maintenance and operation of the Pipe that is the subject of this Agreement only for the transmission of water, and any other purpose or use is prohibited. Notwithstanding any contrary provisions herein, Licensee 625238.1 OCOE-61-186 agrees that this License shall not be used in any way that will inhibit the use of the License Area by FCEN, its successors or assigns. The Pipe shall be constructed, maintained and operated by Licensee in accordance with Exhibit A. CONDUCT OF WORK All work connected with the construction, maintenance, repair, renewal, modification, relocation, reconstruction or removal of the said Pipe shall be undertaken within the License Area. However, no such work shall be performed without prior written notice to, and approval of, FCEN's General Manager. Any and all work shall be performed in a manner satisfactory to the FCEN. All work shall be performed at times and in a manner which shall not disturb the reasonable operation of the business of FCEN. At the sole discretion of FCEN's General Manager a flagman may be required during construction and periods of maintenance. Licensee, in accordance with Paragraph 14 below, shall be responsible for all costs and expenses of any flagging service. 6. FEES Licensee shall pay to FCEN for this License, an annual license fee of Eight Hundred Forty -Four Dollars and 48/100 ($844.48), plus sales tax if applicable. The license fee shall be payable in advance in annual payments on the anniversary date of this License for as long as this License remains in force and effect. Such annual license fee shall increase annually on each anniversary date of this License Agreement in proportion to the increase in the Consumer Price Index, series CWUROOOOAAO annual data, as published by the United States Department of Labor, Bureau of Labor Statistics, over such index from the prior year; provided, however, that in no event shall the annual fee be less than Eight Hundred Forty -Four and 48/100 ($844.48) Dollars. In the event Licensee fails to make the aforesaid annual payment, Licensee shall be considered to be in default, and this License shall cease, be null and void and of no further force or effect, and the Pipe and facilities installed shall become the property of FCEN but only after written notice from FCEN of Licensee's default and the passage of a thirty (30) day opportunity to cure such default. In the event that FCEN has failed to invoice its pricing correctly for any year, FCEN shall have the power to retroactively adjust its price for any past year to conform to that past year's proper pricing schedule. Any retroactive price increase shall be paid for by Licensee together with the annual license fee. 7. TERM The term of the License and of this Agreement shall run for a period of one (1) year from the above date. Thereafter, this Agreement shall automatically renew for successive one- year periods unless or until it is terminated as provided below. In no event shall the Term of the License or this Agreement extend beyond the term of the CSX Lease. 8. TERMINATION Notwithstanding any contrary provisions contained herein, this Agreement may be terminated at any time by either FCEN or Licensee by giving to the other party thirty (30) days advance written notice of its intention to so terminate. In the event of termination, Licensee shall remove the Pipe and restore the License Area as nearly as possible to as good 2 625238.1 OCOE-61-186 order and condition as when original entry was made thereon by said Licensee, at its sole expense, cost and liability. 9. GOVERNMENT REQUIREMENTS Installation of the Pipe pursuant to this License Agreement shall be performed in accordance with all appropriate governmental and administrative requirements for the use(s) for which such Pipe is to be maintained. 10. FCEN REGULATIONS Licensee agrees that it shall observe and obey all regulations of FCEN respecting the use of the License and the License Area. 11. NON -PERMANENT LOCATION Licensee recognizes that it may be in the best interest of FCEN to move the Pipe to other Area within FCEN's property, and therefore, Licensee agrees, at Licensee's cost and expense, to move or relocate the said Pipe at the reasonable request of FCEN. Licensee hereby agrees to effectuate and perform such move expeditiously and within reasonable constraints of time. 12. RISK, LIABILITY, INDEMNITY 12.1 To the extent permitted by law, Licensee shall defend, indemnify and save FCEN and its officers, shareholders, directors, affiliates, employees and agents harmless, from and against, any and all liability, loss, claim, suit, damage, charge, or expense (including reasonable attorney's fees and experts) which any such party may suffer, sustain, incur or in any way be subjected to, on account of death of, or injury to, any person and damage to or loss of or destruction of any property, arising out of, or resulting from, or in any way connected with, the construction, presence, existence, repair, maintenance, replacement, operation, use, or removal of Licensee's Pipe, the use of the License Area pursuant hereto or any structure in connection therewith, or restoration of the License Area to good order or condition. 12.2. Use of FCEN's right of way involves certain risks of loss or damage as a result of FCEN's operations. To the extent permitted by law, Licensee expressly assumes all risk of loss and damage to persons or Licensee's property or Pipe, in, on, over or under the License Area, including loss of or any interference with use thereof, regardless of cause, including derailment, arising out of FCEN's operations. For purposes of this section, Licensee's property shall include the contents of the Pipe as well as property of third parties situated or placed upon FCEN's right of way by Licensee or by such third parties at the request of or for the benefit of Licensee. 12.3 Without limiting the generality of other provisions herein, to the extent permitted by law, Licensee also expressly assumes all risk of loss which may result from Licensee's failure to maintain either the Pipe or the required depth and support for the Pipe. 12.4 Without limiting the generality of other provisions contained herein, to the extent permitted by law, Licensee assumes all responsibility for, and agrees to defend, 625238.1 OCOE-61-186 indemnify and hold FCEN and its officers, shareholders, directors, affiliates, and agents harmless from (a) all claims, costs and expenses, including reasonable attorneys' fees as a consequence of any pollution of air, water, land and/or ground water on or off the License Area, arising from, or in connection with, the use of this License Area or resulting from the leaking, bursting, spilling, or escape of the material transmitted in or through Licensee's Pipe; (b) any claim or liability arising under federal or state law dealing with pollution of air, water, land, and/or ground water arising therefrom or the remedy thereof, and (c) any subsidence or failure of lateral or subjacent support of FCEN's tracks. 12.5 Obligations of Licensee hereunder to defend, indemnify and hold FCEN harmless shall also extend to companies or other legal entities that control or are under common control with FCEN and its/their respective officers, agents and employees. 12.6 Licensee's duty to indemnify shall survive the expiration and/or termination of this License Agreement. 12.7 Nothing herein shall be construed as a waiver of Licensee's sovereign immunity. 13. NOTICES All notices on the part of Licensee to FCEN shall be given in writing to the General Manager, FLORIDA CENTRAL RAILROAD COMPANY, INC., of 3001 W. Orange Avenue, Apopka, FL 32703. All notices on the part of FCEN to Licensee shall be given in writing to the Attn: Charles K. Smith, Utilities Director, THE CITY OF OCOEE, 150 N. Lakeshore Drive, Ocoee, FL 34761. All notices shall be sent in person, or via overnight courier, facsimile or email. 14. FCEN COSTS AND EXPENSES Licensee agrees to pay to FCEN all costs and expenses incurred by FCEN due to FCEN's granting of this License or due to the use, maintenance or existence of said License by Licensee. Such costs and expenses shall include, but are not limited to, FCEN's cost of providing flag protection services pursuant to Paragraph 5 above. Licensee's cost for such flag protection services shall be the then -current rate per day for the particular flag protection services that FCEN determines, in its sole discretion, are required after reviewing the needs of the work site. 15. COSTS AND ATTORNEYS FEES In the event FCEN retains the services of attorneys, other professionals or persons in order to collect fees or other obligations from Licensee hereunder, FCEN shall be entitled to collect from Licensee all such attorney's fees, professional fees and costs so incurred, including but not limited to, said attorney's fees and costs for litigation and appeals thereof. 4 625238.1 OCOE-61-186 16. NO WARRANTIES This License is herein granted without any warranty, express or implied, and Licensee hereby agrees that no damages shall be recoverable from FCEN because of any dispossession of Licensee or because of any failure of, defect in, cancellation of, or termination of, FCEN's property interest in the License Area. 17. ASSIGNMENT No assignment of rights or privileges hereunder by Licensee shall be valid unless the written consent of FCEN is first obtained. 18. FUTURE PARTIES This License shall inure to the benefit of, and be binding upon, the Parties hereto and their respective, heirs, legal representatives, successors and assigns. 19. REMEDIES The remedies under this Agreement are cumulative and shall not exclude any other remedies to which any party may be lawfully entitled. The failure or delay of any party to insist upon the strict or timely performance of a covenant hereunder or any obligation hereunder, shall not be a waiver of such party's right to demand strict compliance therewith in the future. 20. CAPTIONS All titles or captions are inserted for convenience only and they in no way shall be construed to define, limit or describe the scope of this Agreement or any provision thereof. 21. SEVERABILITY If any clause or provision of this Agreement shall be deemed to be invalid or unenforceable under present or future laws, then, in that event it is the intention of the Parties that the remainder of this Agreement shall not be affected thereby. 22. CHOICE OF LAW This instrument is being delivered and is intended to be performed in the state of Florida and shall be construed and enforced in accordance with the laws of that state. Any aggrieved party may proceed to enforce its rights in the appropriate action at law or in equity. Venue for all suits arising out of this instrument shall lie exclusively in the Courts of Orange County, Florida. By execution or adoption of this agreement, each party hereby submits itself to the in personam jurisdiction of the Courts of Orange County, Florida. 23. INSURANCE 23.1 Licensee shall maintain insurance in the following amounts: (a) General liability insurance in the amount of Two Million dollars ($2,000,000); (b) Contractual liability in the amount of Two Million dollars ($2,000,000); (c) Worker's compensation, statutory limits or greater; (d) Automobile liability, One Million dollars ($1,000,000); and (e) Railroad Protective Liability with bodily injury protection of Two Million dollars ($2,000,000) and property damage of Two Million dollars ($2,000,000). 5 625238.1 OCOE-61-186 All such insurance shall name FCEN as an additional insured. The original of the railroad protective liability policy shall be provided to FCEN and certificates of insurance evidencing Licensee's compliance with subparagraphs (a), (b), (c), (d) and (e) above shall be forwarded to FCEN prior to any work commencing on or within the License Area. Notwithstanding anything to the contrary, the insurance required under subparagraph (e) shall only be required during installation of the Pipe and whenever the Pipe will be reconstructed, updated, maintained or otherwise improved. 23.2 Licensee shall cause each of its subcontractors to maintain the insurance as set forth in Paragraph 23.1, above. 24. MODIFICATION All modifications or waivers to this License Agreement must be in writing and executed by both parties. 25. MERGER This Agreement represents the final, complete and exclusive understanding of the Parties of the subject matter hereto. 26. LICENSEE'S AUTHORITY TO EXECUTE THIS AGREEMENT Licensee represents and warrants that it has taken all necessary actions required in order to enter into this License Agreement and cause it to be fully enforceable against Licensee, and that its agent below is authorized to execute this License Agreement. [END OF DOCUMENT EXCEPT FOR SIGNATURE PAGE AND EXHIBIT] 0 625238.1 OCOE-61-186 IN WITNESS WHEREOF, the parties have executed this Agreement as a sealed instrument on the day, month and year first written above. Signed and delivered in the presence of. Witness Print Name: FLORIDA CENTRAL RAILROAD COMPANY, INC. By: Thomas C. Owen President CITY OF OCOEE, a Florida municipal corporation Print Name: Witness Print Name: Witness FOR USE AND RELIANCE ONLY BY THE CITY OF OCOEE, FLORIDA; APPROVED AS TO FORM AND LEGALITY this _ day of , 2017. SHUFFIELD LOWMAN & WILSON, P.A. By: City Attorney APPROVED BY THE OCOEE CITY COMMISSION AT A MEETING HELD ON , 2017 UNDER AGENDA ITEM NO. 7 RUSTY JOHNSON Mayor Attest: MELANIE SIBBITT City Clerk 625238.1 OCOE-61-186 EXHIBIT A LICENSEE'S JULY 28, 2016 APPLICATION FOR PIPE CROSSING (6 pages below) 625238.1 Application for Facility Installation Plans for proposed installation shall be submitted to and meet the approval and requirements of the Railroad Company before construction is begun. Material and installation are to be in strict accordance with specifications of the National Electrical Safety Code (NESC) or the American Railway Engineering Association (AREMA) which ever applies. An original Plan, Section and Elevation views from field survey showing location in respect to Mile Post, width of Railroad Right of Way, location of adjacent structures affecting crossing must accompany application. If open cutting or tunneling is necessary, details of sheeting and method of supporting tracks or driving tunnel shall also be shown. Flagging as defined by Railroad is required during installation and costs are responsibility of Agreement Holder. Date Application RR Agreement Received by Road: 7/29/ 16 Application Fee: $720 No: OCOE-61-186 Railroad Approval: Licensing Type: Annual Licensing $844.48 and c i Amount: P FIELDS BELOW TO BE FILLED IN UAPWCANT x h Narrative to provde a bsc�ticope of oik to begird ilue�p rme oleo f i :>eas� , m�C City of Ocoee to install a 20" force main along Bluford Ave, owned and maintained by the City of Ocoee, FL. This project will require a jack and bore underneath the railroad near the intersection of Bluford Ave and Rewis St. Itsta�lation Loc�ofinforiration k 'Mt t'k ...x N .. 'Rx =.0 i # S.. R•'14 '•:#:3bw r '4= n*, .. ;rF SK. «L:5' -Y,f i ri Y: t^2 .+ ✓ City: Ocoee State: FL County: Orange Railroad GPS Latitude GPS Longitude Florida Central Railroad Location: 28D 34'33" N Entering ROW: 81 D 32'39" W Entering ROW: Select a direction from Feet: 60 NE Mile Post No: MP-ST 832.9 nearest railroad mile post: Angle between center line of Total length within No of RR Tracks right of way and occupancy will 47 NE 1 RR right of way 82A to be crossed: be (degrees): measured in feet: Will facility be located within public road rightYes of way: 621878V Bluford Ave Legal Information Owner's Complete Legal Company Name: City of Ocoee Legal Address Line 1: 150 N. Lakeshore Drive Legal Address Line 2: City: Ocoee State: FL Zip: 34761 Business Type: Municipality State of Business Registration: FL The following must be provided for the Name: Charles K. Smith, P.E. Title: Utilities Director person who will sign off on agreement: Page 1 of 4 Billing Information If same as legal address X above, check here: Billing City: Ocoee Billing State: FL Billing Zip: 34761 Billing Address Line 1: 150 N. Lakeshore Drive Billing Address 2: Owner Contact Information Contact Name: Charles K. Smith, P.E. Title: Utilities Director E-mail: csmith@ocoee.org Office Phone: 407-905-3159 Extension: Mobile Phone: 407-509-2723 Emergency Phone: r �� � P _jet i CIO s tai t�A�eht jr formatlo �' �� N ; x z , ti ��. If same as legal address above, check here: Engineer/Consultant/ Agent Company Name: BFA Environmental, Inc. ContactName: Willie Thomas, P.E. Address Line 1: 1230 Hilicrest Street Address Line 2: City: Orlando State: FL Zip: 32803 Office Phone: 407-896-8608 Mobile Phone: 407-399-0075 E-mail thomas@bfaenvironmental.com Is this covered by existing Railroad permit/ No agreement or master agreement? Is this project related to another No transaction/project with railroad? Is this a new New Installation Request installation? Will proposed installation connect to an No existing facility within railroad corridor? Plans of any sub -grade z30" diameter are subject to of Installation: Pipe Method: Sub -grade review by Engineers of Railroad choice at cost & expense of facility owner. this installation be parallel to railroad company anywhere in excess of 150 feet? yes indicate length in feet. Page 2 of 4 Sub grade installation Irlforrrsation f If sub -grade, select the proposed Jack & Bore method of installation: Bury: Base of rail to top of 5.5 feet minimum casing: Bury: Not beneath tracks: 5.5 feet minimum Bury: Roadway ditches: N/A Temporary track support or riprapping required: No Wires, pole obstructions to be relocated: No _ Paps Inst�l�lr� S § j f w Pipe Type: Water — Force Main Flammable: No Max working 100 pressure (PSI): Test Pressure Hydrostatic Type: Pipe Specifications Carrier Pipe Casing Pipe Materials Specs & Grade 20" PVC AWWA C905, DR18 24" HOPE DIPS PE4710, DR17 Minimum Yield Strength of Material PSI Mill Test Pressure PSI 150 150 Inside Diameter 19.06" Wall Thickness 1.2" 0.375" Outside Diameter 21.6" 36" Type of Seam N/A Straight Laying Lengths 20 ft 20 ft Kind of Joints Bell and spigot push on Airtight weld Number of Vents: N/A Size of Vents: N/A Height Above Ground: N/A Seals: Both Ends Cathodic Protection: No Protective Coating: Yes Type, size and spacing of insulators or supports: N/A Page 3 of 4 If application is approved, applicant agrees to reimburse the Railroad for any cost incurred by the railroad incident to installation, maintenance, and/or supervision necessitated by this installation and further agrees to assume all liability for accidents or injuries which arise as a result of this Installation. IF THE APPLICATION IS APPROVED, THE APPLICANT SHALL EXECUTE THE RAILROAD'S STANDARD FORM OF LICENSE AGREEMENT. IN THE EVENTTHE RAILROAD INCURS LEGAL FEES IN EXCESS OF $500 IN CONNECTION WITH THE COMPLETION OF THE LICENSE AGREEMENT THE APPLICANT SHALL PAY FOR ALL SUCH LEGAL FEES OF THE RAILROAD IN EXCESS OF $500. WHETHER APPROVED OR DENIED, IN THE EVENT LITIGATION ARISES OUT OF OR IN CONNECTION WITH THIS APPLICATION OR THE UNDERLYING SUBJECT MATTER OF THIS APPLICATION, THE APPLICANT SHALL BE RESPONSIBLE FOR, AND AGREES TO PAY, ALL ATTORNEY'S FEES AND COSTS INCURRED BY THE RAILROAD. THE APPLICANT AGREES THATTHERE IS VALID CONSIDERATION EXCHANGED BY ALL PARTIES HERETO TO SUPPORT ALL OBLIGATIONS CREATED BY THIS APPLICATION. Title of Officer Utilities Director, City of Ocoee Printed Name of Officer Charles K Smith, P.E. Signing Application: Signing Application: Page 4 of 4 CONSTRUCTION DRAWINGS FOR CITY OF OCOEE DOWNTOWN & WEST SANITARY TRANSMISSION PROJECT (NORTH OF SILVER STAR PHASE) INDEX OF DRAWINGS SHT No DWG No DRAWING TITLE 1 G-1 COVER SHEET 2 G-2 ABBREVIATIONS AND LEGEND 3 G-3 GENERAL NOTES 4 G-4 KEY MAP 5 SUR-1 SURVEY CONTROL 6 SUR-2 ISURVEY CONTROL 7 SUR-3 SURVEY CONTROL 8 SUR-4 SURVEY CONTROL 9 C-1 BLUFORD AVE PLAN AND PROFILE STA 39+40 TO STA 45+40 10 C-2 REWIS ST PLAN AND PROFILE STA 45+40 TO STA 50+60 11 C-3 REWIS ST PLAN AND PROFILE STA 50+60 TO STA 56+60 12 C-4 LAKEWOOD AVE PLAN AND PROFILE STA 56+60 TO STA 62+60 13 1 C-5 ILAKEWOOD AVE PLAN AND PROFILE STA 62+60 TO STA 68+60 14 C-6 LAKEWOOD AVE PLAN AND PROFILE STA 68+60 TO STA 74+60 15 C-7 LAKEWOOD AVE PLAN AND PROFILE STA 74+60 TO STA 80+60 16 C-8 LAKEWOOD AVE PLAN AND PROFILE STA 80+60 TO STA 86+60 17 C-9 LAKEWOOD AVE PLAN AND PROFILE STA 86+60 TO STA 92+60 18 C-10 LAKEWOOD AVE PLAN AND PROFILE STA 92+60 TO STA 95+16 19 C-11 WURST RD PLAN AND PROFILE STA 200+00 TO STA 205+20 20 1 C-12 IWURST RD PLAN AND PROFILE STA 205+20 TO STA 211+20 21 C-13 WURST RD PLAN AND PROFILE STA 211+20 TO STA 217+20 22 C-14 WURST RD PLAN AND PROFILE STA 217+20 TO STA 213+20 23 C-15 WURST RD PLAN AND PROFILE STA 223+20 TO STA 229+20 24 C-16 WURST RD PLAN AND PROFILE STA 229+20 TO STA 235+20 25 C-17 WURST RD PLAN AND PROFILE STA 235+20 TO STA 240+80 26 C-18 WURST RD PLAN AND PROFILE STA 240+80 TO STA 246+80 27 1 C-19 IWURST RD PLAN AND PROFILE STA 247+80 TO STA 253+80 28 C-20 WURST RD PLAN AND PROFILE STA 252+80 TO STA 258+80 29 C-21 WURST RD PLAN AND PROFILE STA 258+80 TO STA 262+00 30 D-1 CONSTRUCTION DETAILS 31 D-2 CONSTRUCTION DETAILS 32 D-3 CONSTRUCTION DETAILS 33 D-4 CONSTRUCTION DETAILS 34 1 D-5 CONSTRUCTION DETAILS 35 D-6 CONSTRUCTION DETAILS 36 LS-1 LIFT STATION PLAN 37 LS-2 LIFT STATION GEOMETRY 38 LS-3 LIFT STATION GRADING 39 LS-4 LIFT STATION GENERAL NOTES 40 LS-5 LIFT STATION GENERAL NOTES 41 1 LS-6 ILIFT STATION GENERAL NOTES 42 LS-7 LIFT STATION DETAILS 43 LS-8 LIFT STATION DETAILS 44 LS-9 LIFT STATION DETAILS 45 LS-10 LIFT STATION DETAILS 46 LS-11 LIFT STATION DETAILS 47 LS-12 LIFT STATION DETAILS 48 1 LS-13 11LIFT STATION DETAILS 49 1 LS-14 ILIFT STATION DETAILS JUNE 2016 VICINITY MAP Weet Rd/ Y - e ,ha, c4,cma oco••� Latin N.T.S f� 6 d = z Wt.1N Hd pa y`t 51 _ C 4T O PROJkCT"Aj'tEA. j Crntt St o ^o U t I+i:; Orucc Eae..rar,.Ra - tr. 3 < O a E E rc a t Olando A•. k % '. ram: b Nmr � A 51cry Rd PaA 7 oaoai gab s' Y = g �d IA.ine St t � an W.,ta ra 4' ay PREPARED BY: .l..F� Environmental Consultants Barnes, Ferland and Associates, Inc. 1230 E. Hillcrest Street, Orlando, FL, 32803 PH: (407) 896-8" FAX.- (4M896-1&22 ENGINEERING BUSINESS No. 6899 CITY MAYOR RUSTY JOHNSON CITY COMMISSIONERS DISTRICT 1: JOHN GROGAN DISTRICT 2: COMMISSIONER ROSEMARY WILSEN DISTRICT 3: COMMISSIONER RICHARD FIRSTNER DISTRICT 4: COMMISSIONER JOEL KELLER CITY MANAGER: ROBERT D. FRANK UTILITIES DIRECTOR: CHARLES SMITH, P.E. CITY ENGINEER: DAVID A. WHEELER, P.E. CITY OF OCOEE UTILITIES DEPARTMENT 1800 A.D. MIMMS ROAD OCOEE, FLORIDA 34761 ENGINEER OF RECORD WILL IE E. THOMAS. P.E. FLORIDA REGISTRATION N. 57612 CONC SIDEWALK CONST 20" PVC FM BORE & JACK FOUND 1-1/4" IP D) \ \ + REPLACEMENT EXIST 2" WM t ' & DRIVEWAY I I LAUNCHING PITNRIW (TYP) TO BE REMOVED I ORE HOLE 01 R/R CROSS ARM SIGNALS CONTROL POINT 7 SET NAIL & D/S FOUND 5/8' IRC CB 7774 I GRUENMEYER" N.• 7542 "�.875' BORE & JACK RECEIVING PIT g 9+32.40 34.20' L FOUND 1 " /P EA B79 30FT SPT" FOUND N&D TELEPHONE / (NO ID) APPAR£N: 12 £.• 4 59.09j' J75.2T =4 I INSTALL: 1-20" 45° BEND =9J'---� t}� — + 8.0' (TYP) 6 6615" PEDESTAL��TYP.J + p 5' NC SIOE)VA o $ ti' t ti FIB OP77C MARKER 20' MIAM/ CURB SIGN ¢ EDGE OF PAVEMENT EDGE OF PAVEMENT C 20" PVC FM /\ F. 2.0' M/AASI CURB I 4 SLUFORD AVE \ + 46*00 47fi00 B BORE HOLE W Z t 105' OF 36" STEEL \ O + it EA B20 SOFT SPT" 124.97' EDGE Of PAVEMENT CASING (0.469" MIN THICK) EDGE OF PAVEMENT NOTE 1) \ EL: = U 20' MlAM/ CURB 1 2.0' MIA Ml CURB (SEE \ �15- RCP w w w --- - ----- ----- ----- - -- - --- --- -- ----- --- - -- ---------_w---- w w INV 12113 ¢ CHU--- 0�-----oFiu-----CHU-f---OHU- -- ,,. -- - - -- - --a16 +T-7 + ---= u-- -- - -- — — — 7--_'—O'N0lf2' /PC 6.42' L � FOUND 1-1 4" IP APPARENT R/W U----- 0H0-- / FOUND 7/2" IP + - —ant— (NO IN �77777 2864' NSTA.6 5*6.B 1-20" 5.625° BEND EXIST 6" WM (NO ID) +L / CA £STAL FOUND 5/8- IRC METAL SIGN (TYP.) '- \� 28 66J5' �LASPC FENCE RAILROAD CROSS/NC APPARENT R VY / 13.0' (TYP) FOUND 5/8" IRC 15 2498" U77L TY POLE (7YP.1 GUARD ARM (TYP.) \\ / �o CURB & GUTTER STA 48+09.0 22.0' L STA 49+02.0 34.0' L REPLACEMENT (TYP) INSTALL EXIST 6" WM INSTALL + o r� 2 - 20" 45° BENDS '� BRICK 2 - 20" 45° BENDS � 1 - 20" PV 2" ARV ASSEMBLY 1 - 20" PV �\ ` +5 2" ARV ASSEMBLY + + Y6° RCt�, N INO-,122. g3' NOTES: �� RESTORATION LEGEND RAILROAD k6p 1. CONTRACTOR HAS THE OPTION OF HDD INSTAL TION AT THE RIR CROSSING IN LIEU OF JACK & BORE INSTALLATION AT NO TRACKS ADDITIONAL COST TO THE CITY. CONTRACTOR ILL BE REQUIRED TO DEVELOP AND SUBMIT AN ALTERNATE HDD INSTALLATION / DESIGN PLAN IN ACCORDANCE WITH CITY STAN ARDS AND THE PINSLEY R/R STANDARDS. THE ALTERNATE HDD INSTALLATION / MILI AND RESURFACE Cj / DESIGN PLAN MUST BE SIGNED AND SEALED BY PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA AND SUBMITTED TO THE CITY AND ENGINEER OF RECORD FOR AF PROVAL. ANY ADDITIONAL PERMITTING AND MOT REQUIREMENTS AND ASSOCIATED ASP iALT OPEN CUT AND REPAIR �P COSTS SHALL BE THE CONTRACTORS RESPONSI 31LITY. RE OVE AND REPLACE CONC SEWALK AND DRIVEWAY 124 - 124 EXIST GRADE n Sr / I I v 120 4•AW 120 - - — -- CONST 20" PVC FM 116 � � 116 CONST 20" PVC FM If CONST CASING CONST 20" PVC FM --- _ - END CAPS (TYP) +/-105 LF OF 36" STEEL CASING (0.469" MIN THICK) 112 (SEE NOTE 1) 112 SCALE: HORZ 1" = 40' VERT 1" = 4" 108 1 108 45+40 46+00 47+00 48+00 49+00 50+00 50+60 No. REVISIONS BY DATE LININ EISI CH CITY OF OCOEE UTILITIES DEPARTMENT ` ,/ 1800 A.D. MIMMS ROAD OCOEE, FLORIDA 34761 �'�\ /�A JE FINjCOI meal COR501�ntS g��, Ferland and Associates, Inc. 1230 E h41/aWtSCeCz Odando, F4328a3 PH(407)896BSCS FAX-NOV8K78a ENGRVEERWG BUSQVESS No. 6899 DOWNTOWN & WEST SANITARY TRANSMISSION PROJECT (NORTH OF SILVER STAR PHASE) DESIGN ENGINEER VYILLIE E. THOMAS, P.E. � PROJECT No.: 2015-03 DRAWNG No. C-2 PROJECTDATE: JUN2016 AT FULLSIZE (IF NOT SCALE ACCORDINGLY) SCALE AS NOTED REWIS ST PLAN AND PROFILE STA 4+0 TO STA + 5 5060 DESIGNED BY: WET DRAWN BY: JAB FLORIDAGISTRA71ONNo. 57612 CHECKED BY: GJH4 SHEET 10 OF 49 DRAWING FILE SEE MARGIN rho day,J"Iy7,20161:1P.25PM F:ICMLIPROJECTSVOI512015.MOmeeWestSan ryTransMmonPro)ec .UUmwMs12gI51rJO ,,MIC .o g JUNE 2016 - FINAL SUBMITTAL