Item VI (B) Ocoee Municipal Complex - Approve Substantial Completion Date T I "CENTER OF GOOD LIVING-PRIDE CSF WEST ORANGE" AGENDA 11-15-94 Ocoee ' f Item VI B of ° CITY OF OCOEE RUSTY o oN w ti v p 150 N.LAI�SHORE DRIVE PAUL W.FOSTER OCOEE FLORIDA 347611258VERN COMBS n�yj (V; ( 6 � JIM GLEASON ► C I Y MANAGER �� of G00� ELLIS SHAPIRO MEMORANDUM DATE: November 7, 1994 TO: The Honorable Mayor and Board of City Commissioners FROM: Montye E. Beamer, Director. Administrative Services SUBJECT: Ocoee Municipal Complex - Substantial Completion The accounting of the construction change orders is as follows: Change Order 17 (additional fire sprinkler heads) $1,945.00 Change Order 18 (steps instead of ramp, Commission Chambers) 587.00 Change Order 19 (additional receptacles, Police Department-P105) 1,019.00 Change Order 20 (carpet upgrades, City Hall) 7,192.00 Change Order 21 (fire control panel upgrade, City Hall) 890.00 Change Order 22 (remote annunciator panel for Police to monitor 2,070.00 City Hall fire alarm panel; various electric relocations, plumbing change to A/C unit) Change Order 23 (electrical work for new generator installation including 30,190.00 contractor's time extension as approved August 2, 1994) Change Order 24 (9-1-1 supplemental electrical; power to flag pole) 2,292.00 The Huber Design and Construction contract totals $1,925,080; original contract sum was $1,684,083. dL The Honorable Mayor and Board of City Commissioners November 7, 1994 Page Two To clarify, the date of Substantial Completion before Change Order Number 23 was May 20, 1994. Based upon the requirement to provide sufficient generator power, the City—as owner— installed the necessary equipment subsequent to the May date. The original estimate to complete the work including diagnostics on the first generator was 87 days or August 15, 1994. This was established in Change Order Number 23 as allowed in the emergency Commissioner agenda item on August 23, 1994. After discussions with the Architect and the Contractor, the dates for the construction to be sufficiently complete for the City's occupancy and for the commencement of warranties were agreed upon as follows: (1) Police Department, July 25, 1994; (2) City Hall including all site work, August 1, 1994. The appropriate certificates have been signed by the Architect and Contractor. They are the standard AIA document C704. Staff recommends that these certificates (Police Department and City Hall including all Site Work) be signed and that Change Order expenditures be confirmed. Action Requested The Mayor and Board of City Commissioners (1) confirmed Change Order Numbers 17 through 24; (2) approve the certification of Substantial Completion for the Police Department as July 25, 1994, and City Hall including all Site Work as August 1, 1994; and (3) authorize the Mayor and City Clerk to execute. MEB/jbw CERTIFICATE OF Distribution to: OWNER SUBSTANTIAL ARCHITECT 0 COMPLETION CONTRACTOR ONTRACTOR ELD 0 • AIA DOCUMENT C704 OTHER 0 PROJECT: OCOEE MUNICIPAL COMPLEX ARCHITECT: C. T. HSU + ASSOCIATES, P.A. (name, address) 150 N. LAKESHORE DRIVE OCOEE, FL 34761 ARCHITECT'S PROJECT NUMBER: 9213.00 TO (Owner): CONTRACTOR: HUBER DESIGN & CONSTRUCTTON CITY OF OCOEE CONTRACT FOR: CITY HALL BUILDING 150 N. LAKESHORE DRIVE OCOEE, FL 34761 L I CONTRACT DATE: 8/24/93 DATE OF ISSUANCE: 8/1/94 —1 PROJECT OR DESIGNATED PORTION SHALL INCLUDE: The Work performed under this Contract has been reviewed and found to be substantially complete. The Date of Substantial Completion of the Project or portion thereof designated above is hereby established as which is also the date of commencement of applicable warranties required by the Contract Documents, except as stated below. DEFINITION OF DATE OF SUBSTANTIAL COMPLETION The Date of Substantial Completion of the Work or designated portion thereof is the Date certified by the Architect when construction is sufficiently complete, in accordance with the Contract Documents, so the Owner can occupy or utilize the Work or designated portion thereof for the,use for which it is intended, as expressed in the Contract Documents. A list of items to be completed or corrected, prepared by the Contractor and verified and amended by the Architect, is attached hereto. The failure to include any items on such list does not alter the responsibility of the Contractor to complete all Work'in accordance with the Contract Documents. The date of commencement of warranties for items on the attached list will be NIX If1fXi 6 €IXO;YrKEKAKNEISXMItYcXICKW KKX(X X?tnt X 8/01/94. C. T. HSU + ASSOCIATES, P.A. b,`�/ 1a/Jq ? ARCHITECT B DATE The Contractor will complete or correct the Work on the list of items tac d her to within days • from the above Date of Substantial Completion. / HUBER DESIGN & CONSTRUCTION INC. l0 7 74, Y CONTRACTOR BY . ATE The Owner accepts the Work or designated portion thereof as substantially complete and will assume full possession thereof at (time) on (date). CITY OF OCOEE, FL OWNER BY DATE The responsibilities of the Owner and the Contractor for security, maintenance, heat, utilities, damage to the Work and insurance shall be as follows: (Note—Owner's and Contractor's legal and insurance counsel should determine and review insurance requirements and coverage; Contractor shall secure consent of surety company, ii any.) AIA DOCUMENT G704 • CERTIFICATE OF SUBSTANTIAL COMPLETION • APRIL 1978 EDITION • AIA* ©1978• THE AMERICAN INSTITUTE OF ARCHITECTS,173S NEW YORK AVE., N.W., WASHINGTON, D.C. 20006 G704—1978 OCOEE MUNICIPAL COMPLEX Revised Architectural Punchlist CITY HALL BUILDING 10-17-94 PUNCH LIST ITEM # DESCRIPTION SIGNED OFF 1 . Room #205 - City Manager's Office: Remove paint from door handles to Conference Room #206. 2. Room #206 - Conference Room: Seal holes at windows at bottom of sill, and window frame. 3. Room #221 - Door to Fire Sprinkler is incomplete - new hardware has been ordered. 4. Room #224 - Attach wall ceiling molding to wall and correct ceiling tile. 5. Room #118 - Correct loose door latching. 6. Room #102 - Seal vertical void at right side of the water fountain at wall and floor. Also, plug hole at left hand side of fountain at wall and floor. 7. Room #106 - Chamber: Center double doors from lobby; adjust vertical door latch to prevent door from dragging on tile floor. 8. West Porch - fixed door sills: Fill voids with cement and trowel finish to match porch finish. 9. First Floor: under eave on back porch, paint is powdery and flaking. Contractor to correct. 10. First Floor: Door 143A has been installed incorrectly. See Architect's plan sheet A-1 for correct swing of door for exit discharge. Exit sign is shown on corridor side. Contractor to remove door system and switch sides, refinish to match existing area finishes. Page 1 of 3 ITEM # DESCRIPTION SIGNED OFF 11 . Finance Manager's Office #218 -Correct the opening and closing of Door #218. 12. City Hall - GRGV A. 2.1 - Seal all incoming underground electrical conduit at main service. B. 2.21 - Provide insulation for exterior ductwork per Specification Section 15560-8. C. Test and Balance Report Correction: 1 . VVT #13 - Terminal box has not been balanced to deliver 230CFM as shown on plans. 2. Verification is required on the operation of the humidistat serving package unit PU-1 . 13. Attached are City of Ocoee's Revised Punch Lists; dated October 13 and October 17, 1994. 14. Attached is a punch list from Professional Engineering Consultants, dated Sept. 14, 1994. 15. GRGV Punchlist notes: Item #1 For all ductwork exterior of building, the Contractor shall provide Type D-3 and E-1 jackets, insulation type RR at 2" thick (Spec. Section 15560-8, 3.01). The lining shall be for three elbows from unit (PU-1). This requirement is greater than the external duct runs and shall be incorporated into the construction. Item #2 All undercuts are indicated on the mechanical sheets by an arrow and the abbreviations U.C. If the Contractor was unfamiliar with this notation he should have inquired about its meaning, rather than ignored its existence. Item #3 Sheet M-1, HVAC General note #6, indicates that there is a concrete pad for all mechanical equipment. Also note that condensate drain trap detail on Sheet M-4 indicates that the piping shall slope a minimum of 1/4" per foot. To attain this, the unit must be raised (4" pad will cover a 16' run of condensate piping). Not only does this apply to the Police Station, but the City Hall building also. Page 2 of 3 ITEM # DESCRIPTION SIGNED OFF 16. Room 222 partition between 222 and 218 separated from the main east wall by a 1/4" crack at that joint. 17. Water test for Building piping: Consult with Owner on providing water quality test as required in Specification Section 01650. 18. Contractor will comply with Section 01700 of Contract Documents for Close Out Requirements. I. Part 1 General 1.1 Section Includes: A. Closeout Procedures B. Final Cleaning C. Adjusting D. Project Records Documents E. Operation and Maintenance Data F. Warranties G. Spare Parts and Maintenance materials Refer to Section Items 1 .2 through 1 .9 for additional information. END OF REPORT bt ,e/A,,//9 Wilbur Peeler Construction Administrator WP/ed c: All Present File (CR)(PF) City Hall 10/17/94 LEAK IN ROOF ON SOUTH PORCH: Waiting for rain to see if corrected. WINDOWS : (a) JEAN GRAFTON' S AREA: Window sill 1/2" below other window sill . Screen needs to be installed. (b) Many windows throughout City Hall are not "finished" (Montye Beamer' s office as an example) . Cracks are appearing around edges . LOCK ON DOOR IN BUILDING/PERSONNEL DEPT. HALL: There is a conflict on plans regarding the correct installation of the lock. Building Code Violation. MILDEW IN CITY MANAGER' S OFFICE ON WALL BETWEEN FRENCH DOORS . HUMIDITY PROBLEM THROUGHOUT BUILDING CREATING MILDEW IN INNER OFFICES . STRESS FRACTURE/2ND FLOOR. KEYS : Grand Master Key still does not work on Door 131 (Abra Dow) DOWNSTAIRS WATER DRINKING FOUNTAIN: Continues to stay "on" OPEN HOLES THROUGHOUT BUILDING: Plates required to cover open outlet areas . CARPETING: (a) Paint smudged noticeably into carpeting in several areas . (b) Defect in Montye Beamer' s office - carpet is frayed behind door. (c) Glue has been noted coming through carpeting - one area is City Manager' s office . (d) Carpet seams very noticeably showing in Commission Chambers in one area of seating. (e) Carpet fraying - Manufacturer inspected and has stated that edges should have been beaded to protect and has not been done creating the fraying and will eventually unravel . PORCH: Paint is peeling off . DOORS : (A) Wanda Horton' s Door - will not stay open and will close slowly when people walk in/out . (B) Mayor Vandergrift' s door is warped. (C) Paint stains still prevalent on many door handles . (D) Doors have scrapes on them (Copy Room downstairs, City Manager Conference Room Door) that Huber was to go around and re- stain. (E) Double door (emergency exit) in Commission Chamber still shows space where you can see light from outside. (F) Double door to Commission Chamber from Lobby - right side scrapes as it closes . (G) There is an uneven finish under the exterior walls in the West Hallway. (H) Mayor' s office door looks warped. ( I) Thresholds to both City Manager French Doors and upstairs lobby doors are sloped at wrong angles and need to be replaced (creating mildew problem) (J) Downstairs Ladies restroom - handicapped door upper hinge is broken (K) Several doors throughout building are sticking (possibly due to humidity problem) DIAS : Section on bottom right side where stain is defective. CRACKS : Many "settling" cracks -- major crack in break room on exterior wall and several appearing all around windows throughout building. PHOTOCELLS TO FLAGPOLES : Photocells are not turning on (possibly due to lights in parking lot) STEM WALL: White patching did not appear to work. FIRE ALARM/SPRINKLER SYSTEM: Please contact Inspector Clement at Fire Department - there are outstanding issues . LIGHT FIXTURES/BULBS : Tim Libke faxed information on 9/16/94 regarding ordering of new fixtures and bulbs . Nothing has been received or installed to date . Light fixture in hallway in front of Personnel has fallen down. Items from September 9, 1994 letter to Buddy Peeler from Paul Gula: 4 . "There are some bad paved areas on the driveway entrance to the parking area to the City Hall. " Status unknown. 10 . "Adjacent to the City Hall building and in between the police building and City Hall, a swale should be constructed to direct the runoff to the stormwater pond. " PEC/C.T. HSU responsible for this . 12 . "New driveway into fire station has no expansion joints . The driveway is not acceptable. " PEC/HUBER responsible. 13 . "Contractor to submit as-built on the installed stormwater system and stormwater pond. As-builts on the pond should show the berm elevation, approximately every 20 feet around the pond. " HUBER responsible. Items frcm September 14, 1994 letter to Montye Beamer from Gary Beverly: Comments addressed from July 29, 1994 still not addressed are items 4, 12 , 13 , and 19 . New Comments that still need to be addressed are items 21, 23 , 24, 25 , 26, and 27 . 10/17/94 11:36 221 407 849 9401 PEC INC 0002/006 PEC PROFESSIONAL ENGINEERING CONSULTANTS, INC. September 14, 1994 0E-148 1-1.0 3-1.0 Ms. Montye Beamer Director of Administrative Services City of Ocoee 150 North Lakeshore Drive Ocoee, Florida 34761 RE: Ocoee Municipal Complex Dear Montye: Pursuant to the request of Mr. Buddy Peeler with C.T. Hsu and Associates, on September 12, 1994 we observed the constructed site with respect to our comments dated July 29, 1994 and have the following comments: Comments from July 29, 1994 that have not been addressed: 1. The June 23, 1994 report prepared by L.J. Nodarse stated "any areas needing repair have been pointed out to the contractor for repair before paving." However, the report does not indicate that the base was repaired and inspected before paving. This should be addressed by L.J. Nodarse. 2. The pavement and base should be cored to check for thickness. The pavement density should be tested. This should be addressed by L.J. Nodarg. 3. Comment deleted. (City Engineering Department has approved what we constructed.) 4. There are some bad paved areas on the driveway entrance to the parking area to the City Hall. The Contractor has stated in their September 9, 1994 letter to Buddy Peeler (herein referenced as the Contractor's letter) that the pavement that was not repaired was damaged by the City's landscaping operations. The • City needs to confirm who is responsible for the damage. If the City is responsible for the pavement damage, did the contractor agree to correct these 10/17/94 11:36 $1 407 849 9401 PEC INC 003/006 Ms. Montye Beamer September 14, 1994 Page 2 areas, for the City, while they were correcting their damage areas? This should addre sed the City. 5. Comments deleted. (City will include this work with the Lake Shore Drive improvements). 6. Comment deleted. 7. All concrete curb that is cracked shall be replaced. Attached is a sketch showing the curbed areas that are still cracked. Huber action required. 8. Comment deleted. 9. Comment deleted. 10. Comment deleted. 11. The north end of the retaining wall, east of the fire station, needs to be reworked. There is exposed rebar and the concrete block has been broken instead of saw cut. The Construction plans called for a header curb to be constructed from the end of the retaining va1l to the curb at the drive. Instead of the header curb construction, the contractor could place concrete blocks at the end of the retaining wall. This masonry work should maintain the existing height of the wall. Huber action reouired. 12. New driveway into the fire station site has no expansion joints. The driveway is not acceptable. The Contractor did not submit to the Engineer a Jointing plan for approval as required by the construction plans. Nor did the Contractor request PEC to review the formed driveway before the pour. We agree with the contractor that the driveway does not exhibit unusual stress cracking or other irregularaties now. Hoever, the driveway could develop stress cracking and irregularities at a later date. Huber action reouired. 13. Contractor shall submit as-built on the installed stormsewer system and stormwater pond. As-builts on the pond should show the berm elevation, approximately every 20 feet around the pond. 10/17/94 11:37 ' '1 407 849 9401 PEC INC 0004/006 Ms. Montye Beamer September 14, 1994 Page 3 The as-built elevations for the bottom of the pond should also be identified (approximately 8 shots). It appeals that the mitered end section is lower than the pond bottom. Huber action required. 14. Comment deleted. 15. Portions of the ditch needs to be sodded. This should be addressed by the City. 16. Comment deleted. 17. Comment deleted. d the immer has 18. The weir bottom�ofeen theconstructed skimmer isnotatkthe correct elevation.n supported. However, thee•ation. Huberr action required. • 19. We would recommend that roof drain gutters be installed on the police building and City Hall. The runoff should be piped to the stormwater pond. City needs to direct the Contractor to install roof drain piping. City action required. 20. Comment deleted. New Comments 21. Parking stall striping at the Tricor Shopping Center needs to be painted. Huber action required. 22. The temporary power poles need to be removed. Huber action required. 23. The new pavement areas have "bird baths". See attached sketch for location. Contractor shall rework pavement to eliminate the water ponding. Huber action required. 24. The plans did not call for the wheel stops to be removed. The wheel stops shall r be replaced. Tuber action required. • 25. The existing, curb along the north edge of the driveway, north of the Fire Station, was removed and was not replaced. Huber action reouired. 10/17/94 11:37 $1 407 849 9401 PEC INC 1005/008 Ms. Montye Beamer September 14, 1994 Page 4 26. The existing concrete sidewalk,de alk with asphalt. rd Not acceptable.cHuber not get fixed. The Contractor tried to patch action required. 27. The back of the curb adjacent to the steps in front of the police building needs to be reworked. The back of the curb is very rough. H er cti n r wired. 28. The edge of pavement correct the as � sketch ts ay should receive amaged. If the Contractor is not going to pavement edge, the C credit for the work. 29. The sidewalk adjacent to Lakeshore Drive damaged ng construction. if the Contractor is not going correct sidewalk, the should receive a credit for the work. Should you have any questions regarding the above, please contact our office. Sincerely, PROFESSIONAL ENGINEERING CONSULTANTS, INC. Gary N. Beverly Project Engineer GNBlss.L53 cc: Buddy Peeler Paul Gula Mike Preim 10/17/94 11:38 $1 407 849 9401 PEC INC Q008/006 • . // In tit43 ��� i — c-,— 7 C= — vv __ _ —� 1P If � ---4 • ../‘ 11 �.- _J PL it i4 I\J: . Fii - / -- --1 . - • " •7Y): f 1 T• I / a i x PI III 1 1 ! --_ • I .` IIi- - IekJiI 3 sisa I : ,-. > 1 r, i ill 1 N : f- b i,• -, -- Ise -tt �_ i , r , Y �a - . : I I i ., ,„ li=I I I 4,. . . • L i • ' I 4.1 { • 1. tttttttttt-.ttltit t p • e!= I I I I I I I I 1 • i` l I 1 1 1 I-f* 1 [ ) t ` it�`iirt L-- -'... )/) .:. 14 V / , , Iii_ f— 1 tat„as„�:+�rs L- 1 1 thl I Li I i J I 4 z ? I \ / i i < ' ZlaZt/ttt:ia$s�ay i I I i ¢ _ 1 ilk VI r%40tixtmt0 i $ I l or t ( at,tt ta►a[►t7yt9 = 1 L_ , ii illiiiini iii t LI —if- 1 ttato � t — — I ii • i.i. U , Ib _ — _I 't” . IL i ■%%%%%%?Mit ttaaitlL a2 , -c—._—— — — ,. — — ._ _ —— i ttltitttichtt01ti►tol anwma r r►tan..301,11 — - . MEMORANDUM TO: Ellis Shapiro, City Manager FROM: Fran Gosnell, Secretary to City Manager DATE: October 13 , 1994 RE : STATUS - OUTSTANDING ITEMS NOTE: THIS PUNCH LIST IS IN ADDITION TO ORIGINAL PUNCH LIST OF 7/1/94 SITE VISIT. . . Police Station LOCKS : The lock on the janitor closet is wrong side out . CABINET: New storage cabinet in Records Dept . was destroyed by a subcontractor who stepped on top of it and crushed it . Combination lock on west side door inoperable ® Need locks on shower doors • Cracked tiles in showers Door to ladies shower room does not close properly ;c5JAdo Records window inoperable - needs to be replaced ® Need gutters City Hall - LEAK IN ROOF ON SOUTH PORCH: Waiting for rain to see if corrected. WINDOWS : (a) JEAN GRAFTON' S AREA: Window sill 1/2" below other window sill . Screen needs to be installed. (b) Many windows throughout City Hall are not "finished" (Montye Beamer' s office as an example) . Cracks are appearing around edges . LOCK ON DOOR IN BUILDING/PERSONNEL DEPT. HALL: There is a conflict on plans regarding the correct installation of the lock. Building Code Violation - Don Flippen to handle. 0 MILDEW IN CITY MANAGER' S OFFICE ON WALL BETWEEN FRENCH DOORS : Don Flippen to locate areas in building with mildew problems and report back findings to Mr. Shapiro. HUMIDITY PROBLEM: Air Conditioning company to be called out to investigate dampness in building. STRESS FRACTURE ISSUE: To be discussed with Huber/C.T. Hsu KEYS : Grand Master Key still does not work on Door 131 (Abra Dow) DOWNSTAIRS WATER DRINKING FOUNTAIN: Continues to stay "on" OPEN HOLES THROUGHOUT BUILDING: These holes are for "growth" and "cameras" for the future. Jim Fredmund says they are the responsibility of CT Hsu. Has offered, however, 'to have Huber put plates over the holes . Approved for Huber to take care of. CARPETING: (a) Discussed w/Huber several times . Paint smudged into carpet in several areas . Huber is to take care of the problems . (b) Defect in Montye Beamer' s office - carpet is frayed behind door. (c) Glue has been noted coming through carpeting - one area is City Manager' s office . DOORS : (A) Wanda Horton' s Door - will not stay open and will close slowly when people walk in/out . (B) Paint stains still prevalent on many door handles . (C) Doors have scrapes on them (Copy Room downstairs, City Manager . Conference Room Door) that Huber was to go around and re- stain. (D) Double door (emergency exit) in Commission Chamber still shows space where you can see light from outside. (E) Double door to Commission Chamber from Lobby - right side scrapes as it closes . (F) There is an uneven finish under the exterior walls in the West Hallway. (G) Mayor' s office door looks warped. (H) Thresholds to both City Manager French Doors and upstairs lobby doors are sloped at wrong angles and need to be replaced correctly. 10/10 - CASTLEROCK CAULKED AROUND DOOR AND BLAMES ELECTRIC LIGHT FIXTURE LEAKING - AND TO HAVE SOMEONE CALL ELECTRICIAN TO CAULK AOUND BEHIND LIGHT. DIAS : Section on bottom right side where stain is defective . CRACKS : Many "settling" cracks -- major crack in break room on exterior wall and several appearing all around windows throughout building. • PHOTOCELLS TO FLAGPOLES : Breakers turned off to power supply at Withers Maguire and panel cover is gone and needs , to be replaced ASAP as panel is HOT. Other photocells are not turning on - it is believed to be because other lights in parking lot are shining on them. STEM WALL: White patching did not appear to work. FIRE ALARM/SPRINKLER SYSTEM: Still some concerns; Inspector Clement handling. Items from September 9, 1994 letter to Buddy Peeler from Paul Gula: • 4 . "There are some bad paved areas on the driveway entrance to the parking area to the City Hall. " Status unknown. 10 . "Adjacent to the City Hall building and in between the police building and City Hall, a swale should be constructed to direct the runoff to the stormwater pond. " PEC/C.T. HSU responsible for this . 12 . "New driveway into fire station has no expansion joints . The driveway is not acceptable. " PEC/HUBER responsible . 13 . "Contractor to submit as-built on the installed stormwater system and stormwater pond. As-builts on the pond should show the berm elevation, approximately every 20 feet around the • pond. " ' HUBER responsible . Everything else has either been done or City to do in the future. Items from September 14, 1994 letter to Montye Beamer from Gary Beverly: Comments addressed from July 29, 1994 still not addressed are items 4 , 12, 13 , and 19 . New Comments that still need to be addressed are items 21, 23 , 24, 25. 26 , and 27 . f CERTIFICATE OF Distribution to: OWNER 0 SUBSTANTIAL ARCHITECT 0 COMPLETION CONTRACTOR RACTOR 0 • AIA DOCUMENT 0704 OTHER 0 • PROJECT: OCOEE MUNICIPAL COMPLEX ARCHITECT: C. T. HSU + ASSOCIATES, P.A. (name, address) 150 N. LAKESHORE DRIVE OCOEE, FL 34761 ARCHITECT'S PROJECT NUMBER: 9213.00 TO (Owner): CONTRACTOR: HUBER DESIGN & CONSTRUCTION CITY OF OCOEE CONTRACT FOR: POLICE BUILDING 150 N. LAKESHORE DRIVE OCOEE, FL 34761 I I CONTRACT DATE: 8/24/93 DATE OF ISSUANCE: 7/25/94 —1 PROJECT OR DESIGNATED PORTION SHALL INCLUDE: The Work performed under this Contract has been reviewed and found to be substantially complete. The Date of Substantial Completion of the Project or portion thereof designated above is hereby established as which is also the date of commencement of applicable warranties required by the Contract Documents, except as stated below. DEFINITION OF DATE OF SUBSTANTIAL COMPLETION The Date of Substantial Completion of the Work or designated portion thereof is the Date certified by the Architect when construction is sufficiently complete, in accordance with the Contract Documents, so the Owner can occupy or utilize the Work or designated portion thereof for the .ase for which it is intended, as expressed in the Contract Documents. A list of items to be completed or corrected, prepared by the Contractor and verified and amended by the Architect, is attached hereto. The failure to include any items on such list does not alter the responsibility of the Contractor to complete all Work'in accordance with the Contract Documents. The date of commencement of warranties for items on the attached list will beXI d M Ii )1laltitOiMtXtIOIS +% rAxocs K X 7./25/94 C. T. HSU + ASSOCIATES, P.A. DA ARCHITECT B \ DAT The Contractor will complete or correct the Work on the list of ite• s tta --d h to vithin days from the above Date of Substantial Completion. HUBER DESIGN & CONSTRUCTION CO. INC. /0 2 7 c CONTRACTOR B • D TE The Owner accepts the Work or designated portion thereof as substantially complete and will assume full possession thereof at (time) on (date). • CITY OF OCOEE, FL OWNER BY DATE The responsibilities of the Owner and the Contractor for security, maintenance, heat, utilities, damage to the Work and insurance shall be as follows: (Note—Owner's and Contractor'; legal and insurance counsel should determine and review insurance requirements and coverage; Contractor shall secure consent of surety company, if any.) AIA DOCUMENT G704 • CERTIFICATE OF SUBSTANTIAL COMPLETION • APRIL 1978 EDITION • AIAe ©1978• THE AMERICAN INSTITUTE Or ARCHITECTS,1735 NEW YORK AVE., N.W., WASHINGTON, D.C. 20006 G704—1978 OCOEE MUNICIPAL COMPLEX ("HA Revised Architectural Punchlist POLICE BUILDING 10-17-94 PUNCH LIST ITEM # DESCRIPTION SIGNED OFF 1. Lobby P100 - Contractor to correct or replace the slide- window for the Records dept. 2. Patrol Commander P107 - Remove grease spot on carpet. 3. Men's Restroom P111 - Contractor to correct imperfection (located in center of door at lock height) in wood door. 4. Room P115 - Reports: Caulk counter backsplash at N.W. wall - between Door #113 and #115. 5. Rooms P123 and P124 - Training and briefing: Remove grease spot(s) from carpet. 6. P133 - Administration: Patch and finish around window frame. 7. Contractor to consult with Owner on water test requirements under Section 01650. 8. Contractor will comply with Section 01700 for close out requirements. END OF REPORT 1//G71G. 0 Atd Wilbur Peeler Construction Administrator WP/ed c: All Present File (CR)(PF) Police Station 10/17/94 LOCKS : The lock on the janitor closet is wrong side out . Combination lock on both East and West side door inoperable Need locks on doors leading to mens/womens shower areas Door to ladies shower room does not close properly. Shower rods never installed in either shower area. CABINET: New storage cabinet in Records Dept . was destroyed by a subcontractor who stepped on top of it and crushed it . Additionally, black scuff marks along wall where subcontractor climbed. Cracked tiles in shower stalls where screws were drilled. Records window inoperable/defective . Replace completely. Humidity problem throughout building, especially in Sergeant' s supply room. Building is very damp in the mornings . CEILING PANELS : Cracked panel in Sgt . Goclon' s Office Panel missing in Drug Locker Evidence Room: stains in several panels from leak in A/C ducts (leak repaired) Training Room: stains in several panels Weight Room: stains in panels Hallway: stains in panels Electrical plate cover missing in Evidence Room. Lengthwise crack in Records Room - above the shredder. Air Returns (2) have rust spots in Breakrocm. Cracked window tiles in Detective Tom' s office . Closure arm on hallway entrance door never installed. Need gutters .